Adtran NetVanta 900 Quick Start Guide

NetVanta 900 Series Breakout Panel
Quick Configuration Guide
61200799L48-42A November 2004
Install Breakout Panel 1200799L48 (Rack Mounted)
The NetVanta 900 Series system is intended to be installed, maintained, and serviced by qualified personnel only.
1. Hold the Breakout Panel front panel in place on the front right corner of the chassis and install the two screws (see Figure 1, step a) making sure that the front panel is firmly attached to the corner of the chassis.
2. Attach the backplane circuit board assembly to the front panel and secure it with the remaining four screws (see Figure 1, step b). See Figure 2 for the breakout panel rack mounting solution.
3. Remove the plastic cap from the two amphenol connectors. Attach the amphenol cables to the
VOICE ports on the side of the chassis and then to the respective Breakout Panel ports.
Make sure that the the correct receptacles.
VOICE ports for slots 2 through 4 and slots 5 through 7 are connected to
SLOTS 5-7
Step a.
Step b.
SLOTS 2-4
Figure 1. Attaching the Breakout Panel
The two RJ-48C connectors marked CTRLR are reserved for future use.
Technical Support 1-888-4ADTRAN (1-888-423-8726)
The figure below illustrates the front view of the chassis and Breakout Panel in an equipment rack.
Figure 2. Breakout Panel Rack Mounting Solution
Refer to page 3 for instructions on installing the Breakout Panel (1200799L50).
2 Technical Support 1-888-4ADTRAN (1-888-423-8726) 61200799L48-42A