For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide
NETVANTA 5305 CONTROLLER P/N 1200831L1
SPECIFICATIONS
Interfaces: Console: EIA-232 (DB-9 female) for access to command line
interface and monitoring
Ethernet: Two 10/100BaseT interfaces (RJ-48C) for
connection to the local area network
Compliance: FCC Part 15, Class A, UL 60950/CSA-C22.2 No. 60950,
EN 60950, IEC 60950, AS/NZS 60950, EN 55022, EN 55024
Environmental: Operating Temperature: 0°C to 50°C
Storage Temperature: 20°C to 70°C
Relative Humidity: 95% non-condensing
INSTALLATION INSTRUCTIONS
1. Remove the existing controller from the controller slot in the NetVanta 5305
Base Unit.
2. Slide the System Controller into the controller slot until the module is firmly
positioned in the chassis.
ETHERNET PINOUT
Pin Name Description
1 TX1 Transmit Positive
2 TX2 Transmit Negative
3 RX1 Receive Positive
4, 5 — Unused
6 RX2 Receive Negative
7, 8 — Unused
CONSOLE PINOUT
Pin Name Description
1 DCD Data Carrier Detect (output)
2 RD Receive Data (output)
3 TD Transmit Data (input)
3. Secure the screws at both edges of the module. Tighten with a screwdriver.
4. Connect the cables to the associated device(s).
5. Complete the system installation as specified in the Hardware Installation
Guide (P/N 61200990L1-34).
Quick Start Guide, 61200831L1-13B, July 2004 Technical Support 1-888-4ADTRAN (1-888-423-8726) © 2004 ADTRAN, All Rights Reserved
4 DTR Data Terminal Ready (input)
5 SG Signal Ground
6 DSR Data Set Ready (output)
7 RTS Request to Send (input)
8 CTS Clear to Send (output)
9 RI Ring Indicate (output)
NETVANTA 5305 CONTROLLER P/N 1200831L1
Quick Start Guide
CONNECT THE CONSOLE INTERFACE
Before connecting to the NetVanta 5305 CONSOLE interface you will need
the following items: VT100 terminal or PC (with VT100 terminal emulation
software) and a straight through serial cable with a DB-9 (male) connector
on one end and the appropriate interface for your terminal (or PC) on the
other.
1. Connect the DB-9 (male) connector of your serial cable to the
CONSOLE port on the rear panel of the unit.
2. Connect the loose end of the serial cable to the VT100 terminal or PC
(with terminal emulation software).
3. Open a VT100 terminal session to the NetVanta 5305 using the
following settings: 9600 baud, 8 data bits, no parity bits, and 1 stop bit.
Press <Enter> to activate the ADTRAN Command Line Interface (CLI).
For more detailed documentation, visit us online at www.adtran.com
Commands
Refer to the ADTRAN Operating System (OS) Command Reference Guide
(provided on the system documentation CD) for details on configuring the
system using the CLI.
Quick Start Guide, 61200831L1-13B, July 2004 Technical Support 1-888-4ADTRAN (1-888-423-8726) © 2004 ADTRAN, All Rights Reserved