ADTRAN MX2820 M13 MUX User Manual

61186002L1-22E
0501
MX2820
M13 MUX
P/N 1186002L1
CLEI: M3C3RG0A_ _
M13 MUX
1186002
ACT
ALM
STAT
DS3
TEST
STAT
DS1
TEST
*61186002L1-22E*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
LED STATUS FOR ACTIVE MUX
ACT
ALM
DS3 STAT
DS3 TEST
DS1 STAT
DS1 TEST
! Green Normal (All OK)
!/! Green/Amber (Alternating) Normal and console open
! Red Self-test failed
! Amber Software update in progress
!/! Red/Amber (Alternating) Self-test failed and console open
4 Red (Flashing) Module has failed
! Green No critical, major, or minor alarms
! Red Major or minor alarm in progress
4 Red (Flashing) Critical alarm in progress
! Green Normal (DS3 OK)
! Red AIS, OOF, RAI, Idle alarms
4 Red (Flashing) DS3 LOS or DS3 Failure (critical) 4 Red (Flashing once per event) Single/Burst DS3 code violations
!/! Red/Green (Alternating) DS3 XCV threshold exceeded
" Off No DS3 tests in progress
! Amber In test (locally originated)
4 Amber (Flashing) In test (remotely originated)
" Off All DS1s are disabled
! Green Enabled DS1s normal (All OK)
! Red Non-critical DS1 alarm (CAIS, LAIS)
4 Red (Flashing) LOS on an enabled line (critical DS1
4 Red (Flashing once per event) Single/Burst RX DS1 code violation
!/! Red/Green (Alternating) DS1 XCV threshold exceeded
" Off No DS1 tests in progress
! Amber In test (locally originated)
4 Amber (Flashing) In test (remotely originated)
LED STATUS FOR STANDBY MUX
ACT
ALM DS3 STAT
DS3 TEST DS1 STAT
DS1 TEST
4 Green (Flashing) Normal (All OK)
! Amber Software update in progress
4 Red Failure
" Off Permanent state during standby " Off Normal (DS3 OK)
4 Red (Flashing) In test (remotely originated)
" Off Permanent state during standby " Off Normal (DS1s OK)
4 Red (Flashing) DS1 Failure
" Off Permanent state during standby
alarm; non-critical system alarm)
DESCRIPTION
The MX2820 M13 MUX is a plug-in unit for the MX2820 chassis that provides an M13 multiplexer function to the MX2820 system. Two MX2820 M13 MUX cards are used together to provide a redundant M13 multiplexer circuit. The MX2820 M13 MUX:
Provides 1:1 redundancyMeets the requirements for NEBS Level 3.
INSTALLATION AND TURNUP
After unpacking the unit, inspect it for damage. If damage is found, file a claim with the carrier and then contact ADTRAN Customer Service. Refer to the Warranty Statement on this Job Aid.
This module occupies a MUX slot in the MX2820 chassis. To install the M13 MUX in the chassis, perform the following steps:
1. Pull the ejector tab into the down position and gently but firmly push the MUX into the selected MUX slot. Simultaneous thumb pressure at the top and at the bottom of the unit will ensure a good seat of the MUX into the backplane connector.
2. Push the ejector tab up and closed against the front panel. Upon installation, the MUX will begin a self-test. This is followed with the LEDs reflecting
the true state of the hardware.
OPERATIONAL SPECIFICATIONS
Operates from A or B input voltage power feeds.
–48 VDC Systems: –42 VDC to –56 VDC–24 VDC Systems: –22 VDC to –27 VDC+24 VDC Systems: +22 VDC to +27 VDC
Operates over extended temperature range of –40ºC to +50ºC without fans or –40ºC to +65ºC
with fans.
Storage –40ºC to +85ºC. Relative humidity to 95 percent, noncondensing.
COMPLIANCE
The MX2820 M13 MUX complies with UL 60950, NEBS Level 3, and GR-1089-CORE.The MX2820 M13 MUX is intended for installation in restricted access areas only.The MX2820 M13 MUX is intended for installation in a Type “B” or “E” enclosure.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this equipment.
Code Input Output
Power Code C C Telecommunication Code (TC) – Installation Code (IC) A
PROVISIONING
All provisioning of the MX2820 M13 MUX will be handled through the SCU. The menu tree on the reverse of this Job Aid provides the options and default settings for the MX2820 M13 MUX.
1. Disabled
2. Enabled
3. Auto Enable*
1. 2 seconds*
3. 2 hours
2. 1 hour
4. 12 hours
5. 1 day
6. 2 days
7. 7 days
1. AMI
1. Disabled*
2. CSU (T1 Only)
3. NIU (T1 Only)
1. 0-133 ft*
3. 266-399 ft
2. 133-266 ft
2. B8ZS/HBD3*
5. 533-655 ft
1. 0-6dB Loss
4. 399-533 ft
1. Disabled
2. Enabled*
1. Disabled*
3. 1E-4
2. 1E-3
5. 1E-6
4. 1E-5
1. Data Mode*
3. Analog Network
2. Tributary
4. Digital Line/Net
5. CODEC Line/Net
6. Remote Loopback
7. LS CSU Loopback
8. LS CSU LB w/BERT
9. LS NIU Loopback
10. LS NIU LB w/BERT
12. HS CSU Loopback
14. HS NIU Loopback
15. HS NIU LB w/BERT
11. LS Line BERT
16. HS Line BERT
13. HS CSU LB w/BERT
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61186002L1-22E
8. HS Line BERT
1. Data Mode*
3. Digital Loopback
2. Line Loopback
5. Remote ALL T1/E1
1. Data Mode*
3. Analog Network
2. Tributary
4. Digital Line/Net
5. CODEC Line/Net
6. Remote Loopback
7. LS Line BERT
4. Remote Loopback
1. QRSS*
1. Data Mode*
2. Network Loopback
3. ALL ZEROES
2. ALL ONES
5. 1 in 8 (1:7)
4. 2 in 8 (2:6)
6. 2 ^15-1 INV
1. C-BIT
2. M13*
1. Loop
2. Local*
1. DS3 Framing
2. DS3 Timing
1. Disabled*
3. 1E-4
2. 1E-3
1. Disabled
3. FEAC
2. FEAC/C-BIT*
4. C-BIT
3. DS3 Remote Loopbacks
4. 1E-5
4. DS3 XCV Threshold
1. ADTRAN*
2. PPP
1. 260 (PREFERRED)*
5. 1E-6
5. IP Forwarding Protocol
1. M12 (4xT1)*
2. G.747 (3xE1)
2. 1500
6. IP Forwarding MTU
14. DS3 Equipment Identification
7-13. DS2 Mode (DS2 #1-7)
29. Set Multiple
30. Auto Enable Delay
(T1/E1 #1-28)
1. T1/E1 State
T1:
(T1/E1 #1-28)
(T1/E1 #1-28)
3. T1/E1 Line Length
2. T1/E1 Line Coding
E1:
(T1/E1 #1-28)
4. T1/E1 Loopback Detection
30. Protection Threshold (1-28): 1*
(T1/E1 #1-28)
29. Set Multiple
(T1/E1 #1-28)
5. T1/E1 Circuit Protection
(T1/E1 #1-28)
6. T1/E1 Line Identification
7. T1/E1 XCV Threshold
1. IS*
2. OOS
T1/E1 #1-28
29. DS3
1. Card nA
2. Card nB
3. Facility Service States
30. Set Multiple
2. Enabled*
1. Perform Manual Switch
1. Disabled
2. Minimum Switching Period (sec.) (10*)
3. Maximum Switch Threshold (3*)
4. Clear Number of Switches
1. Disabled
3. 5 Minutes*
2. 1 Minute
4. 10 Minutes
5. 15 Minutes
T1:
E1:
T1/E1 Loopbacks (T1/E1 #1-28)
6. 30 Minutes
7. 45 Minutes
8. 60 Minutes
29. DS3 Loopbacks
1. Near End Daily
3. Far End Daily
2. Near End Quarter Hourly
5. Near End Daily Thresholds
4. Far End Quarter Hourly
6. Near End Quarter Hourly Thresholds
7. Near End Daily Thresholds
30-36. DS2 #1-7 Loopbacks
37. Reset ALL Tests
38. Pattern
8. Near End Quarter Hourly Thresholds
9. Clear DS3 Statistics
1. Near End Daily
3. Near End Daily Thresholds
2. Near End Quarter Hourly
4. Near End Quarter Hourly Thresholds
5. Clear T1/E1 Statistics
CLEI Code
Serial Number
Part Number
Code Version
1. Configuration
Code Checksum
Boot Version
Boot Checksum
Self Test
1. Network Interface
2. Provisioning
2. T1/E1 Interfaces
3. Service States
4. Protection
7. Card Reset
6. Restore Factory Defaults
8. Auto Save
5. Save Provisioning
9 . Loopback Timeout
10 . Card Pair ID
3. Status
4. Test
1. DS3 Statistics
5. Performance Monitoring
2. T1/E1 Statistics
3. Clear ALL Statistics
Note: An asterisk (*) indicates default setting