For more detailed documentation, visit us online at www.adtran.com
IQ 310 T1 NETWORK INTERFACE MODULE (NIM) P/N 1202802L1
SPECIFICATIONS (CONTINUED)
Environmental
Operating Temperature:
Storage Temperature:
Relative Humidity:
0 to 50 C
-40 to 85 C
Up to 95% non-condensing
SPECIFICATIONS
Network Interface
Framing: SF / ESF with auto detection
Line Coding: AMI / B8ZS
Input signal: to -36 dB
Clock Source: network or internal
Line Build Out: 0, -7.5dB, -15 dB, -22.5dB
Data Rate: 56k or 64k
Connector: RJ-48
Compliance
FCC Part 15, Class A
FCC Part 68
Industry Canada CS03
UL and CUL
INSTALLATION INSTRUCTIONS
1. Remove the power from the unit.
2. Slide the option module into the option slot until the module is firmly
seated against the front of the chassis.
3. Secure the pins at both edges of the module.
4. Connect the cables to the associated device(s).
5. Complete installation of the Base Unit.
6. Restore power to the unit.
Quick Start Guide, 61202802L1-13A, March 2004 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2004 ADTRAN, All Rights Reserved
IQ 310 T1 NETWORK INTERFACE MODULE (NIM) P/N 1202802L1
T1 NETWORK (RJ-48C) CONNECTION PINOUT
Pin Name Description
1 R1 Receive data from the network
2 T1 Receive data from the network
3 — UNUSED
4 R Transmit data toward the network
5 T Transmit data toward the network
6-8 — UNUSED
For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide, 61202802L1-13A, March 2004 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2004 ADTRAN, All Rights Reserved