ADTRAN HTU-C - 3192 User Manual

HTU-C / 3192
CLEI: T1L4SNSC_ _
JOBAID
61245004L6-22B
0104
CIRCUIT BOARD ROTARY SWITCH - SW2
Selects the DSX-1 Line Build Out
0..........0 - sets LBO to 0-133 feet
Note: Positions 5,6 & 7 are not used.
CIRCUIT BOARD JUMPER - P1
Selects the span powering voltage
LV (–140 Vdc)
Used to span power circuit with 0 or 1 HRE
HV (–190 Vdc)
Used to span power circuit with multiple HREs
CIRCUIT BOARD JUMPER - P3
Selects the framing of the HDSL circuit
UNF
HTU-C operates in unframed mode
AUTO
HTU-C auto detects framing
DSX EQ BANTAM JACKS
Provides an intrusive test access point to the data stream
TX
Accesses the data stream being received from the local loop
RX
Accesses the data stream being transmitted to the local loop
RS-232 DB-9 CONNECTOR
Used to access performance monitoring data, perform loopbacks and provision units
via VT100 emulation software such as Hyper Terminal – Private Edition and ProComm Plus.
Provision terminal port as follows:
Data Rate — 19.2 kbps Asynchronous Data Format — eight data bits, no parity (none), one stop bit
When using a PC with terminal software, be sure to disable any power saving
programs.
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN’s U.S. Carrier Networks Equipment Warranty: (877) 457-5007, Document #414.
HTU-C / 3192
STATUS LEDs
LP1 / LP2 OFF No synchronization between the HTU-C and the next
HDSL unit (HRE or HTU-R) on loop1 / loop2
RED Poor signal quality on loop1 / loop2
YELLOW Marginal signal quality loop on loop1 / loop2
GREEN Good signal quality on loop1 / loop2
FLASHING Error detected at HTU-C or HTU-R
DSX OFF DSX-1 signal not detected
FLASHING BPV, Frame Error (SF), CRC Error (ESF) is detected
GREEN DSX-1 signal is present and synchronized
ALM OFF No alarm condition detected
RED Local alarm condition detected (HTU-C), or local and
remote alarm condition detected (HTU-C and HTU-R)
YELLOW Remote alarm condition detected (HTU-R)
LBK OFF No active loopback
FLASHING Armed but not in loopback
YELLOW Local loopback is active
FACEPLATE SWITCH - SW1
Selects response of HTU-R upon Customer Loss of Signal
AIS
HTU-R generates unframed all 1s toward network upon loss of customer signal
LBK
HTU-R generates loopback towards network upon loss of customer signal
CDI
HTU-R generates framed all 1s toward network upon loss of customer signal
FACEPLATE SWITCH - SW3
Loopback Timeout
Enabled
Loopback timeout is enabled
Disabled
Loopback timeout is disabled
Manual Line Code Select
AMI
AMI line code is selected
B8ZS
B8ZS line code is selected
Latching Loopback
T1
Allows only standard T1 testing
FT1
Allows for fractional T1 testing
External Alarm
Enabled
External alarm is enabled
Disabled
External alarm is disabled
COMPLIANCE CODES
This product complies with UL 1459, third edition. It is intended to be installed in an enclosure with an Installation Code (IC) of “B” or “E” and in Restricted Access Locations only. Input current at maximum load is 1 A, and maximum output at overcurrent condi­tion is 160 mA at -188 Vdc.
Code Input Output
Installation Code (IC) A – Telecommunication Code (TC) X Power Code (PC) F C
For complete Installation and Maintenance: (877) 457-5007, Document #300. Please have your fax number available.
C A U T I O N
HTU-C
1245004L6
H
LP1
D S
LP2
L
DSX
ALM
LBK
C
AIS
L
LBK
O
CDI
S
LBK
TM OUT
DIS
T1
DIS
EN AMI FT1 EN
EXT ALM
TX
RX
BZS
R S 2 3 2
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
!
INSERTION LOSS MEASUREMENTS
10000 15.00
50000 25.50 100000 30.00 150000 32.75 196000 35.00 200000 35.25
NOTE: If your TIMs is unable to transmit 200 kHz tone, set the TIMs to one of the frequencies shown above and compare the received signal to the maximum loss at that frequency.
Turn-up Guide
1. Set option switches according to circuit design and local practice.
2. Install HTU-C and HTU-R.
3. See reverse side of this job aid to ensure all LEDs are correct and synchronization has occurred. a) HTU-C will have red ALM LED if not connected to network. LP1 and LP2 should be solid
green.
b) HTU-R will have red ALM LED if no customer connected. LP1, LP2, line coding and framing
(if not UNFR) LEDs should be illuminated.
4. If all LEDs are correct: a) Verify that the signal quality is the same on each loop. Ensure signal quality indicators do
not fluctuate.
b) Verify that the loop loss is within design limits. If there is a difference of more than 1 dB
between the two loops, a problem exists with the cable pairs.
c) If errors occur, use the Current System Status and Performance History screens to determine
where they are occurring. See Troubleshooting Guide section.
5. If everything checks out, proceed with BERT testing.
Troubleshooting Guide
The HTU-C DSX LED is Flashing, but no Errors are Indicated by the HTU-R
A BPV, Frame Error (SF) or CRC Error (ESF) has been detected at the DSX-1 interface. Possible network
or wiring problem between the HTU-C and the DSX. This is not an indication of problems on the HDSL loops.
The HTU-R DS1 LED is Flashing, but no Errors are Indicated by the HTU-C
A BPV, Frame Error (SF) or CRC Error (ESF) has been detected at the DS1 interface. This indicates a
wiring problem or a B8ZS/AMI mismatch between the HTU-R and the customer equipment. This is not an indication of problems on the HDSL loops.
Frequency Maximum
(kHz) Loss Data (dB)
The HTU-R has Power, but LP1 and LP2 LEDs are Dark. The Unit cannot Sync with the HTU-C
Simplex power for powering the HTU-R can be passed over cable pairs that contain load coils or
that are too long for HDSL synchronization. Using a TIMs, verify the circuit is within design limits.
The HTU-R will power up as long as there is at least one good conductor on each loop. To test,
remove the protector plug at the MDF and measure t-r resistance to the HTU-R on both loops. The HTU-R will place a 3 ohm short between t-r on both loops. An extremely high impedance indicates an open conductor. An extremely low reading on one loop may indicate a t-r short in the field. In the field, measure t-t and t-r voltage with the HTU-C installed and compare to the chart above. If these voltages are not present, open pairs or mis-wiring is indicated. As with other circuits, standard resistance measurements between each conductor and ground should also be used to test for a grounded conductor.
If the HTU-C is optioned for LV and there are two HREs in the circuit, the HTU-R could fail to
power up normally. The LEDs on the HREs or HTU-R will flash at a rate of 3 times/second. Make sure the voltage option on the HTU-C is set to HV.
A high resistance open which degrades to the point that it causes the circuit to lose sync can
be “resealed” by reseating the HTU-C. Test the cable pairs before reseating the HTU-C.
Running Excessive Errors on the Loop
Measure t-r resistance as described above. If the pairs are unbalanced by more than 4 ohms, or
a measurement varies a great deal, this could indicate a high resistance open or an intermittent fault on the loop with the higher measurement. A TDR is typically required to locate this splice for repair.
Excessively long bridged taps can also cause errors. Check the records and/or use a TDR to verify the
location and length of bridged taps.
Using ADTRAN’s “Performance History” screen, it is often possible to see that many more errors
are being received on a particular loop or at a particular unit. The fault will typically be very close to the unit receiving the most errors.
No Power at the HTU-R
This could be caused by a loop with two open conductors. Measure t-r resistance from the MDF
to the HTU-R or use the voltage chart to see which pair is open.
Check the HV/LV option on the HTU-C and re-option if necessary.
HTU-C VMDF HRE 1 HRE2 HTU-R
AB CD EF
t-t Voltage t-t Voltage t-t Voltage t-t Voltage t-t Voltage t-t Voltage Open at Frame HV 185 - 190 N/A N/A N/A N/A N/A Open at Frame LV 145 - 150 N/A N/A N/A N/A N/A HTU-C LV / HTU-R 145 - 150 145 - 150 130 - 145 N/A N/A 125 - 130 HTU-C LV / HRE1 / HTU-R 130 - 135 110 - 135 110 - 135 N/A N/A 100 - 135 HTU-C HV / HRE 2 / HTU-R 185 - 190 160 - 185 160 - 185 140 - 185 140 - 185 130 - 185
NOTE: All measurements taken with HTU-C installed.With the HTU-C unseated or with protector removed at VMDF, t-r resistance will be cable resistance plus 3 ohms (for either HRE or HTU-R).
TURN-UP & TROUBLESHOOTING GUIDE
Pricing and Availability 800.827.0807
Tech Support 800.726.8663
Return for Repair 256.963.8722
www.adtran.com