HDSL4 239 H4R Repeater
61223445L2-22A
0610
HDSL4
239 H4R
P/N: 1223445L2
CLEI: T1R6U89D_ _
*61223445L2-22A*
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
©2006 ADTRAN, Inc.
All Rights Reserved.
LED STATUS INDICATORS
Label Indication Description
LP1/LP2
NET
LP1/LP2
CUST
!
LL/RL
{ Off
z Solid Green
4 Fast Flashing Green
4 Slow Flashing Green
z Solid Yellow
4 Flashing Yellow
z Solid Red
4 Flashing Red
{ Off
z Solid Green
4 Fast Flashing Green
4 Slow Flashing Green
z Solid Yellow
4 Flashing Yellow
z Solid Red
4 Flashing Red
z Solid Green
z Solid Yellow
4 Flashing Yellow
No span power is present
Synchronized with an Signal-to-Noise Ratio (SNR)
margin greater than the SNR Margin Alarm Threshold
Flashing three times per second indicates attempt to
synchronize with the H4TU-C
Flashing once per second indicates synchronization
with a SNR margin greater than the SNR Margin
Alarm Threshold; attenuation is greater than the user
recommended Loop Attenuation Alarm Threshold
Synchronized with a SNR margin greater than 0 dB,
but less than the SNR Margin Alarm Threshold
Synchronized with a SNR margin greater than 0 dB,
but less than the SNR Margin Alarm Threshold;
attenuation is greater than the Loop Attenuation
Alarm Threshold
Synchronized with a SNR margin of 0 dB
Flashing once per second indicates synchronization
with a SNR margin of 0 dB; attenuation is greater than
the Loop Attenuation Alarm Threshold
No span power is present
Synchronized with an Signal-to-Noise Ratio (SNR)
margin greater than the SNR Margin Alarm Threshold
Flashing three times per second indicates attempt to
synchronize with the H4TU-R
Flashing once per second indicates synchronization
with a SNR margin greater than the SNR Margin
Alarm Threshold; attenuation is greater than the Loop
Attenuation Alarm Threshold
Synchronized with a SNR margin greater than 0 dB,
but less than the SNR Margin Alarm Threshold
Synchronized with a SNR margin greater than 0 dB,
but less than the SNR Margin Alarm Threshold;
attenuation is greater than the Loop Attenuation
Alarm Threshold
Synchronized with a SNR margin of 0 dB
Flashing once per second indicates synchronization
with a SNR margin of 0 dB; attenuation is greater than
the Loop Attenuation Alarm Threshold
A loopback is active at the H4R towards the H4TU-R
A loopback is active at the H4R towards the H4TU-C
H4R is armed but not in loopback
H4R CARD EDGE PIN ASSIGNMENTS
Pin Designation Description Pin Designation Description
1 GND Ground 7 NC No Connect
2 NC No Connect 8 T Network Loop 2 Tip
3 T1 Customer Loop 1 Tip 9 R Network Loop 2 Ring
4 R1 Customer Loop 1 Ring 10 GND Ground
5 T1 Network Loop 1 Tip 11 T Customer Loop 2 Tip
6 R1 Network Loop 1 Ring 12 R Customer Loop 2 Ring
239 H4R RESISTANCE
Tip-to-Ring resistance is approximately 6 Ω for each pair (with no power applied).
LOOPBACK AND CONTROL CODES
Refer to the Installation and Maintenance Practice of the H4TU-C or H4TU-R used in the
circuit for a list of loopback codes.
HDSL4 LOOP SPECIFICATIONS FOR OPTIMUM OPERATION
NOTE: The H4TU-Cs (P/N 1221401L6, 1221403L6, 1221404L6) support only one
Refer to the H4TU-C or H4TU-R Installation and Maintenance Practice for loop
parameters, including Attenuation and Resistance Budgets for span powering.
repeater in the HDSL4 circuit.
H4TU-C H4R1 H4R2 H4TU-R
1st Segment
2nd Segment
3rd Segment
COMPLIANCE
The 239 H4R complies with UL 60950, Third Edition. The 239 H4R is intended for
installation in restricted access locations only. Ensure chassis ground is properly
connected.
Code Input Output
Power Code (PC) C C
Telecommunication Code (TC) X X
Installation Code (IC) A –
For more information, refer to the Installation and Maintenance Practice (P/N 61223445L2-5) available online at www.adtran.com.
PRICING AND AVAILABILITY 800.827.0807
HDSL4 239 H4R Repeater
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61223445L2-22A
HOUSINGS AND CAPACITIES
H4R Capacity
Part Number Description CLEI Code Slots Stub
1150027L1 239/439 Housing DDMOABA1MA 4 Air 4 4 All All Stainless/Polymer
1150027L2 239/439 Housing DDMOBBA1MA 4 Gel 4 4 All All Stainless/Polymer
1150057L1 Universal Housing DDMODA01RA 4 Air 4 4 All All Stainless Steel
1150057L1 Universal Housing DDMODA01RA 4 Gel 4 4 All All Stainless Steel
1150058L1 Universal Housing DDMOEE01RA 8 Air 8 8 All All Stainless Steel
1150058L2 Universal Housing DDMOFE01RA 8 Gel 8 8 All All Stainless Steel
Manufacturer Description Manufacturer’s Part Number Slots
®
ADC
ADC Radiator SPX-HRXC-30-B1 8 8 8 All All Stainless Steel
Circa Telecom
Circa Telecom HDSL-12B 760006 12 12 12 All All Stainless Steel
Arris®/Lucent®/AT&T
Arris/Lucent/AT&T Keptel Inter Link 818/819 RF819A1 or RF819A2
Arris/Lucent/AT&T Keptel Inter Link 820 Family RF820AX or RF820BX 2 to 8 Full Full All All Polymer
Charles Industries G21 Series 6212050002xx 25 12 N/A 1,2,4,6,7,8,9,11,13,15,18,24 N/A Stainless Steel
Charles Industries G21 Series 6212040002xx 12 6 N/A 1,3,4,6,8,11 N/A Stainless Steel
* For 16 slot use, the ambient air temperature measured 1 foot away and parallel to the housing should not exceed 115°F (46.1°C).
®
®
Arris Keptel Inter Link 819 Family AT819B1U or AT819A1U 12 8 8 2, 3, 5, 6, 8, 9, 11, 12 2, 3, 5, 6, 8, 9, 11, 12 Polymer
Radiator II SPX-HRXC-30-AG-016GT 16 16 16 All All Stainless Steel
HDSL-12A 760005 12 12 12 All All Stainless Steel
Keptel® Inter Link™ 809
RF809A3-XXX or RF809B3-XXX 12 8 N/A 1, 3, 4, 6
RF819B1 or RF819B2
25 12 16 * Chamber 1:
Above
Ground
Above
Ground
H4R Capacity Recommended Slot Assignments
Below
Ground
Below
Ground
Above Ground Below Ground
7, 9, 10, 12
1, 4, 7, 8, 11, 14
Chamber 2:
15, 17, 19, 20, 23, 25
Recommended Slot
Assignments
Above
Ground
Ground
15, 16, 18, 19, 20, 22, 24, 25
Below
N/A Polymer
Chamber 1:
1, 3, 5, 7, 8, 10, 12, 14
Chamber 2:
Material
Material
Polymer
FEATURES
TScan
The 239 H4R incorporates the TScan™ feature, which allows for remote retrieval of circuit diagnostics
and performance of advanced fault location. For more information, refer to the Installation and
Maintenance practice.
Fast Retrain
Fast Retrain is an ADTRAN-proprietary feature that minimizes downtime due to an intermittent
impairment (bad splice, noise burst, etc.).
When such impairments occur after achieving HDSL synchronization, Fast Retrain is invoked to
restore service within 5 to 7 seconds. This short retrain time allows for reduced downtime compared to
the traditional 25 to 30 second retrain duration.
NOTE: For proper functionality, install Fast Retrain capable units on both ends of the circuit. Failure
of a Fast Retrain attempt initiates the traditional (25-30 second) retrain.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty
Fault Bridging
The Fault Bridging feature minimizes downtime due to intermittent impairments that appear on the
cable pair, for example, from a Ground Fault Interrupt (GFI), short, micro-interruption, bad splice, or
noise burst. This feature allows the DSL transceivers to maintain synchronization during an
interruption, thus avoiding a 25 to 30-second retrain. Depending on the type of impairment,
interruptions up to 200 ms can be bridged.
Bad Splice Detection
The Runtime TScan bad splice detection feature is an ADTRAN-proprietary non-intrusive method for
detection of anomalies (bad splices) in the copper plant. This feature non-intrusively monitors the cable
pair during runtime for the presence of bad splices that can potentially impact service.
Poor cable splices are often undetected by normal testing methods. Often, these splices present no
problem for the data transmission equipment until oxidation with the splice itself causes a rapid
impedance change, which can cause errors, signal margin fluctuation, and retrain of the DSL
transceivers. The splice detection feature is accessed from the Troubleshooting Screen through the craft
access port.
.