ADTRAN FT1 DP User Manual

HDSL Quick Installation Guide
for ADTRAN FT1 DP and FNID
PRACTICES
Three eight-position switch packs (SW1, 2, 4) and two four-position switch packs (SW3, 5) are used to configure FT1 DP mode of operation as listed in the table below. Refer to ADTRAN Installation/Maintenance practices for more information.
Option Settings
(arrows indicate default settings)
Switch Function
SW1-1 ............. Channel Select
Closed ............. Alternate
Open ............... Contiguous
Description
SW1-2 ............. Auto Code Detect
Closed ............. Auto
Open ............... Manual
SW1-3 ............. Manual Code Select
Closed ............. AMI
Open ............... B8ZS
SW1-4 ............. Auto Frame Detect
Closed ............. Auto
Open ............... Manual
SW1-5 ............. Framing
Closed ............. Superframe Format (SF)
Open ............... Extended Superframe Format (ESF)
SW1-6 ............. Latching Loopback
Closed ............. Enabled
Open ............... Disabled
SW1-7 ............. Loopback Timeout
Closed ............. 20 Minutes
Open ............... None
SW1-8 ............. Loopback Keep Alive
Closed ............. AIS
Open ............... All 1s, framed
SW2-8, 2-7...... DS1 Transmit Level
Open, Open .... 0 dB
Open, Closed.. -7.5 dB Closed, Open.. -15 dB Closed, Closed -22.5 dB
SW3-1 ............. Idle Code Detect
Closed............. Auto
Open ............... Manual
SW 3-2 ............ Idle Code
Closed............. FF
Open ............... 7F
SW4-1-SW4-8 Channels 1-8 A/B Signaling
Closed............. Enabled
Open ............... Disabled
SW5-1-SW5-5 Channels 9-12 A/B Signaling
Closed............. Enabled
Open ............... Disabled
When this switch is closed, the unit automatically detects the line code as B8ZS or AMI.
When SW1-2 is open, SW1-3 open selects B8ZS line code, while SW1-3 closed selects AMI.
When this switch is closed, Auto Frame Mode detection is enabled and the unit selects between SF and ESF modes automatically. When open, SW1-5 manually selects the framing mode.
When SW1-4 is open, SW1-5 closed selects SF. SW1-5 open selects ESF.
This switch is used to enable or disable latching loopbacks.
SW1-7 is used to enable or disable automatic loopback timeout.
Sets the data pattern sent to the customer upon FNID network loopback.
The DS1 signal level delivered to the customer through the FNID may be selected as one of four values: 0, -7.5, -15, or -22.5 dB.
When SW3-1 is closed, auto idle code detection is enabled and the unit selects between 7F (Hex) and FF (Hex).
When SW3-1 is open and SW3-2 is closed, selects FF (Hex). When SW3-2 is open, selects 7F (Hex).
This switch enables or disables A/B signaling for Channel 1-8 of the selected FT1 channels.
This switch enables or disables A/B signaling for Channels 9-12 of the selected FT1 channels.
FNID SW1, SW2 20 mA, 60 mA Off, On
Indicates default setting
POWER
LOCAL SPAN
Powered
by -48
VDC
Powered
by span
current
SW1
DS1 SEALING CURRENT
20MA 60MA
20 mA sealing current select
OFF ON
SW2
Sealing current disabled Sealing current enabled
1Section 61242.047L2-13, Issue 161242.047L2-13A
FT1-DP FT1-Repeater
FNID
Channel Bank
Backplane
12 11 10
9 8 7 6
Loop 1 Loop 15
Central Office Customer Premises
2B1Q
12 kft 24-AWG
9 kft 26-AWG
(max.)
6
3 4
2B1Q
12 kft 24-AWG
9 kft 26-AWG
(max.)
7
13
Loop Insertion Loss Data
INVALID HDSL CABLE LENGTHS
Frequency (Hz) Maximum Loss (dB)
3,000 12.0 10,000 15.0 50,000 25.5
100,000 30.0 150,000 32.75 200,000 35.25
2.5
2.0
TOTAL
BRIDGED
1.5
1.0
TAP
0.5
LENGTH
(KFT)
0.0
5 15
DS1
55 49
5 4 3 2
WORKING LENGTH OF 24 GAUGE (OR COARSER) CABLE (KFT)
VALID HDSL CABLE LENGTHS
1 0
0
1234
WORKING LENGTH OF 26 GAUGE CABLE (KFT)
56789
HDSL Loss Values
(200 kHz cable loss in dB/kft at 135Ω)
Cable Cable Temperature: Gauge Type 68° 90° 120°
26 PIC 3.902 4.051 4.253 26 Pulp 4.030 4.179 4.381 24 PIC 2.863 2.957 3.083 24 Pulp 3.159 3.257 3.391 22 PIC 2.198 2.255 2.333 22 Pulp 2.483 2.45 2.629 19 PIC 1.551 1.587 1.634 19 Pulp 1.817 1.856 1.909
These approximations are to be used as guidelines only and may vary slightly on different loops. Adhering to these guidelines should produce performance in excess of 10
-7
BER.
ADTRAN Customer Service:
ADTRAN Telco Technical Support............... (800) 726-8663
Standard support hours ................................ Monday-Friday
7 a.m. - 7 p.m. CST
Emergency support ................... 7 days/week, 24 hours/day
Sales .............................................................(800) 827-0807
RMA (repair service).................................... (205) 963-8722
Repair and Return Address:
ADTRAN, Inc. Customer Service Department 901 Explorer Boulevard Huntsville, Alabama 35806-2807
2 Section 61242.047L2-13, Issue 1 61242.047L2-13A