TOTAL ACCESS®1000 239 HRE
JOBAID
239 HRE
CLEI: VAR1FC0B_ _
239 HRE
1179513L1
LP1
LP2
LP1
LP2
LL
(Y)RL(G)
N
E
T
C
U
S
T
LED STATUS
NETWORK
LP1 / LP2
●● OFF No synchronization with the ICOT.
● GREEN Synchronized with good signal quality on NET Loop 1/Loop 2
(> 2 dB margin).
● YELLOW Synchronized with marginal signal quality on NET Loop 1/Loop 2
(1 to 2 dB margin).
● RED Synchronized with poor signal quality on NET Loop 1/Loop 2
(0 dB margin).
CUSTOMER
LP1 / LP2
●● OFF No synchronization with the RT.
● GREEN Synchronized with good signal quality on CUST Loop 1/Loop 2
(> 2 dB margin).
● YELLOW Synchronized with marginal signal quality on CUST Loop 1/Loop 2
(1 to 2 dB margin).
● RED Synchronized with poor signal quality on CUST Loop 1/Loop 2
(0 dB margin).
LL / RL
●● OFF No active arming or loopback is detected at the HRE.
● YELLOW Indicates LB from HRE toward the network is active.
● GREEN Indicates LB from HRE toward the customer is active.
HDSL LOOP SPECIFICATIONS FOR OPTIMUM OPERATION
■ Cable pairs must be nonloaded
■ No single Bridged Tap > 2 kft
■ Maximum loop resistance is 800 Ω
■ Pulse attenuation (LOSS on HDSL Current System Status screen) <
30 dB
■ Impulse noise <
50 dBrn as measured using a 50 kb filter
■ Total Bridged Tap < 2.5 kft
■ 196 KHz insertion loss < 35 dB
■ Signal quality of 6 dB or higher, with no fluctuation and equal on both loops
■ Wideband Noise < 31 dBrn as measured using a 50 kb filter
■ Internal Clock Accuracy +25 ppm (exceeds Stratum 4)
61179513L1-22A
0212
LOOPBACK AND CONTROL CODES
FUNCTION CODE RESPONSE
ARM (in-band) 11000 (binary) ICOT and HRE(s) will arm and the HLIU will loop up toward the network.
ARM (ESF Data Link) FF48 (hex) or 1111 1111
0100 1000 (binary) sent ICOT and HRE(s) will arm and the HLIU will loop up toward the network.
in the Facility Data Link
Disarm (in-band) 11100 (binary) All units are removed from the armed state and loopbacks will be released.
Disarm (ESF Data Link) FF24 (hex) or 1111 1111
0010 0100 (binary) sent in All units are removed from the armed state and loopbacks will be released.
the Facility Data Link
Activation ICOT
1
D3D3 (hex) or If received while in an armed state, the ICOT will loop toward the network.
1101 0011 1101 0011
(binary)
Loop down w/out 9393 (hex) or Automatically releases without disarming any ICOT and HRE that may be in
disarming
2
1001 0011 1001 0011 (binary) loopback toward the network.
HRE Network Loop up
1
C741 If an HRE is present and units armed, the HRE will loop up toward network..
(1100 0111 0100 0001)
HLIU Loop up
1
C742 If received while in an armed state, the HLIU will loop toward the network..
(1100 0111 0100 0010)
1
Units must be armed with 11000b or FF48h before this code will work.
2
In order to behave like an NIU, the HLIU will not loop down from the network side with 9393h.
NOTE: All codes listed above must be sent for a minimum of 5 seconds in order for them to be detected and acted upon.
■ For a complete Installation and Maintenance Practice (P/N 61179513L1-5): (877) 457-5007, Faxback Document 900. Please have your fax number ready. ■
#61179513L1-22A#
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Card Edge Pin Assignment
Pin Designation Description
1 GND Ground
2 NC No Connect
3 T1 Customer Loop 1 Tip
4 R1 Customer Loop 1 Ring
5 T1 Network Loop 1 Tip
6 R1 Network Loop 1 Ring
7 NC No Connect
8 T Network Loop 2 Tip
9 R Network Loop 2 Ring
10 GND Ground
11 T Customer Loop 2 Tip
12 R Customer Loop 2 Ring
HOUSING DIAGRAMS
ADTRAN 8-slot AT&T/Keptel/ABACON
Above Ground Above Ground Below Ground
SPC 6-slot SPC 8-slot AT&T/Keptel
Above Ground Above Ground Above Ground
POWERING OPTIONS
The ICOT will power the entire Total Access
1000 System. When an HRE is used to extend
the range of the POTS circuits, a second ICOT
is used to provide auxiliary span power to the
system through additional copper pairs. (See
Figure 1). The Total Access 1000 system
continues to receive span power through the
HDSL loops. The second ICOT is only needed
for its span powering capacity. No circuit
information can be accessed from it. No
DSX-1 connections are necessary. The loop
will not train, and it will always show an alarm
condition. Applications using only U-BR1Tes
do not require an additional ICOT.
WARRANTY
ADTRAN will replace or repair this product
within the warranty period if it does not meet
its published specifications or fails while in
service. Warranty information can be found at
www.adtran.com/warranty. USA and
Canadian customer Faxback: (877) 457-5007,
Document 414.
COMPLIANCE
The 239 HRE complies with the requirements
covered under UL 60950 and is intended to be
installed in an enclosure with an Installation
Code (IC) of “B” or “E.” Ensure chassis ground
is properly connected.
TURNUP GUIDE
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61179513L1-22A
ADTRAN 239 REPEATER HOUSINGS
PART # Description HRE Capacity CLEI Code* Material
1150027L1 4-slot Air Stub 4 DDMOABA1MA Stainless Steel
1150027L2 4-slot Gel Stub 4 DDMOBBA1MA Stainless Steel
1152010L3 2-slot Gel Stub 2 DDMOBAE1RA Valox Plastic
1152010L4 2-slot Air Stub 2 DDMOAAE1RA Valox Plastic
1150057L1 4-slot Air Stub 4 DDMODA01RA Stainless Steel
1150057L2 4-slot Gel Stub 4 DDMOCA01RA Stainless Steel
1150058L1 8-slot Air Stub 6 DDMOEE01RA Stainless Steel
1150058L2 8-slot Gel Stub 6 DDMOFE01RA Stainless Steel
1190816L1 16-slot Air Stub 16 DDMOES01RA Stainless Steel
1190816L2 16-slot Gel Stub 16 DDMOFS01RA Stainless Steel
HRE 239 DEPLOYMENT IN OTHER HOUSINGS
Company Description HRE Capacity Material
Above Ground Below Ground
AT&T, Keptel, ABACON 25-slot 12 16** Polymer
SPC 6-slot Air Stub 5 6 Stainless Steel
SPC 6-slot Gel Stub 5 6 Stainless Steel
SPC
†
8-slot Air Stub 7 8 Stainless Steel
SPC
≠
8-slot Gel Stub 7 8 Stainless Steel
Keptel 8-slot Air Stub 8 8 Valox Plastic
AT&T, Keptel 12-slot Air Stub 6 N/A Polymer
Lucent 100-slot 42 N/A Steel
1, 4, 7, 8, 11, 14, 15,
17, 19, 20, 23, 25
1, 3, 5, 7, 8,10, 12, 14, 15,
16, 18, 19, 20, 22, 24, 25
Lucent 100 Slot
Above Ground
Filled:
Shelf 1: 1, 3, 5, 7, 9, 11
Shelf 2: 1, 3, 5, 7, 9, 11, 14, 16, 18, 20, 22, 24
Shelf 3: 1, 3, 5, 7, 9, 11, 14, 16, 18, 20, 22, 24
Shelf 4: 1, 3, 5, 7, 9, 11, 14, 16, 18, 20, 22, 24
* TIRKS function code for all cases is HTURENN
** 16 units can be loaded inside the 819 housing for all below ground mounting orientations.
if the 819 housing is mounted specifically in the vertical, stub down direction, 18 units
can be loaded in slots 1, 3, 5, 7, 8, 10, 12, 13, 14, 15, 17, 18, 19, 20, 21, 22, 24, 25.
† Vented ≠ Pressurized
1, 3, 5, 7, 9, 11
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
750
S
S
S
S
S
P
S
U
1
1
7
9
0
0
8
L
1
P
O
W
E
R
A
T
M
B
C
U
1
1
7
9
1
1
2
L
1
N
E
T
W
O
R
K
T
E
S
T
A
D
M
I
N
A
D
S
L
1
1
7
9
4
1
3
L
1
L
O
O
P
1
2
3
4
A
D
S
L
1
1
7
9
4
1
3
L
1
L
O
O
P
1
2
3
4
A
D
S
L
1
1
7
9
4
1
3
L
1
L
O
O
P
1
2
3
4
1
1
7
9
1
0
9
L
1
H
L
I
U
L
O
O
P
1
2
3
4
Switch
N
O
S
X
S
Y
N
C
C
R
C
Q
M
D
I
S
C
R
E
M
N
O
D
S
U
L
B
K
R
X
(
O
U
T
)
T
X
(
I
N
)
T
R
D
D
B
1
2
9
1
0
0
4
D
D
S
T
o
t
a
l
R
e
a
c
h
O
N
1
9
.
2
5
6
6
4
S
C
9
.
6
4
.
8
2
.
4
Q
M
L
L
B
678954321
A
P
CUSTOM
TELECOM
E190349
N
O
S
X
S
Y
N
C
C
R
C
Q
M
D
I
S
C
R
E
M
N
O
D
S
U
L
B
K
R
X
(
O
U
T
)
T
X
(
I
N
)
T
R
D
D
B
1
2
9
1
0
0
4
D
D
S
T
o
t
a
l
R
e
a
c
h
O
N
1
9
.
2
5
6
6
4
S
C
9
.
6
4
.
8
2
.
4
Q
M
L
L
B
678954321
A
P
CUSTOM
TELECOM
E190349
239HRE
1221045L1
DSL NET
DSL CUST
LL
(Y)
RL
(G)
ICOT
Modules
Total Access 1000 RT
System
HRE
Auxiliary
Power
Pairs
Phone
T1
TR-08
SF
or
ESF
Central Office
Customer Premises
Code Input Output
Power Code (PC) C C
Telecommunication Code (TC) X X
Installation Code (IC) A –
Figure 1