Total Access® 1000 DSLAM Dual T1/E1 LIU
T1/E1 LIU
1179010L1
LOOP 1
LOOP 2
Installation and Maintenance
CONTENTS
1. GENERAL .................................................................... 1
2. INSTALLATION .......................................................... 2
3. TESTING ...................................................................... 3
4. MAINTENANCE ......................................................... 3
5. SPECIFICATIONS ....................................................... 3
6. WARRANTY AND CUSTOMER SERVICE ............... 4
FIGURES
Figure 1. Total Access 1000 DSLAM DUAL
T1/E1 LIU ......................................................... 1
Figure 2. Total Access 1000 DSLAM DUAL T1/E1
LIU Menu Tree .................................................. 3
TABLES
Table 1. Compliance Codes ............................................. 2
Table 2. Front Panel Indicators........................................ 3
Table 3. Specifications .................................................... 3
Section 61179010L1-5A
Issue 1, November 2002
CLEI Code: VACJC90C_ _
1. GENERAL
This section provides installation and maintenance
information for the ADTRAN Total Access 1000
DSLAM Dual T1/E1 LIU. Figure 1 is an illustration
of the unit.
Revision History
This is the initial release of this document. Future
revisions to this document will be explained in this
subsection.
Features
The basic features of the Total Access 1000 DSLAM
Dual
T1/E1 LIU, List 1, P/N 1179010L1 include the
following:
• Terminates up to two T1/E1 lines providing an
interface to the network.
• SF and ESF data framing formats. (T1)
• B8ZS line code format. (T1)
• Local, payload and network loopbacks.
• Front panel indicators showing the status of the
unit.
• FAS and FAS+CRC framing. (E1)
• HDB3 line code. (E1)
Figure 1. Total Access 1000 DSLAM
Dual T1/E1 LIU
General Description
The ADTRAN Total Access 1000 DSLAM Dual T1/
E1 LIU is a common card plug-in for the ADTRAN
Total Access 1000 DSLAM. It connects the Data
Access Terminal to a T1/E1 line. All data formatting
and line encoding as well as backplane timing and
control are performed by the Total Access 1000
DSLAM Dual T1/E1 LIU.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by
ADTRAN could void the user’s authority to operate
this equipment.
61179010L1-5A
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
1
2. INSTALLATION
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
After unpacking the unit, inspect it for damage. If
damage is noted, file a claim with the carrier, and then
contact ADTRAN. Refer to Warranty and Customer
Service.
The Total Access 1000 DSLAM Dual T1/E1 LIU, List
1, plugs directly into the ADTRAN Total Access 1000
Data Access Terminal. No installation wiring is
required.
The Total Access 1000 DSLAM Dual T1/E1 LIU
should be installed in the Total Access 1000 Data
Access Terminal channel bank in the slot labeled LIU.
When installing the T1/E1 LIU in the Total Access
1000, grasp the unit by the front panel and push the
unit into the connector until the unit is fully seated.
Lock the unit into position.
Compliance Codes
This product is intended to be installed in a Total
Access 1000 Chassis providing a Type “B” or “E”
enclosure, with Restricted Access. Table 1 shows the
Compliance Codes for the Total Access 1000 LIU.
Electronic Provisioning
The craft interfaces on the Total Access 1000 ATM
BCU are used to change default options and obtain
access module status through menu screens. To access
the menu screens, connect a VT100 terminal or
computer running a terminal emulation program to the
front panel craft interface ADMIN port using a
standard male-to-male RS-232 DB-9 cable. Craft port
settings are as follows:
• 9600 Baud (default) (changeable to 19200 or
38400 in menus)
• No parity
• 8 Data bits
• 1 Stop bit
Windows HyperTerminal
Windows HyperTerminal can be used as a VT100
terminal emulation program. Open HyperTerminal by
selecting PROGRAMS/ACCESSORIES/
HYPERTERMINAL. Refer to the Help section of
HyperTerminal for additional questions.
NOTE
To ensure proper display background, select
VT100 terminal emulation under SETTINGS.
Table 1. Compliance Codes
Code Input Output
Power Code (PC) C C
Telecommunication Code (TC) X –
Installation Code (IC) A –
Provisioning Options
All options on the T1/E1 LIU are provisionable
electronically using the craft interface on the ATM
BCU (Bank Controller Unit). See Figure 2.
Password
The ATM BCU will display the log on screen, and a
valid user ID and password are required to access
menus. The factory default is ADMIN for the account
administrator, and PASSWORD for the password.
Menu Navigation
To traverse through the menus, select the desired entry
and press ENTER. To work backward in the menu
press the ESC (escape) key.
2
61179010L1-5A