We would recommend to make use of our website contents (www.ads-tec.de) in
order to use current data and to be quickly and comprehensively informed of any
technical modification.
DANGER
Indicates an imminent danger. If not avoided,
death or severe injury will result.
WARNING
Indicates a possible danger. If not avoided, death
or severe injury could result.
CAUTION
Indicates a possible danger. If not avoided, light
or minor injuries could result.
ATTENTION
Indicates a possibly damaging situation. If not
avoided, the system or something in its
surroundings could be damaged.
Information:
The symbol "Information" indicates notes, terms and/or conditions that strictly
need to be observed to ensure optimised and/or zero-defect operation. Tips
and suggestions for the efficient use of the device and software optimisation
are also provided.
1 Notes
1.1 Relevant device documentation
The following documents are decisive to unit setup and operation:
User manual (this documentation):
Contains information for installation, commissioning and operation of the device along with technical
data of the device hardware.
Website
You can download drivers, software, user manuals, leaflets and flyers from the Download section of our
All data, text and figures were prepared to the best of our knowledge. They do not represent any
assurance for the properties themselves. Despite taking utmost care, no liability can be assumed for
accuracy, completeness and actuality of the information. Subject to changes.
1.4 Trademarks
It is noted that any software and/or hardware trademarks and any company brand names mentioned in
this documentation are all subject to the general trademark protection rights.
StoraXe® and Big-LinX® are registered trademarks of ads-tec.
All other third-party trademarks used are hereby acknowledged.
In the case of infringement of trademark rights, ads-tec reserves the right to exercise all rights.
1.5 Copyright
This instruction manual is protected by copyright. For the authorised user, simple usage rights are
granted within the scope of the intent of the contract. Any modified use or exploitation of the provided
content, particularly duplication, modification or publishing in whatever form is permitted only with the
prior consent of ads-tec.
In the case of copyright infringement, ads-tec reserves the right to exercise all rights.
in operation* -20 ... 55°C
for storage -30 ... 60°C
Temperature for devices including a heater
in operation* -30 ... 55°C
for storage -30 ... 60°C
Humidity
In operation 10 … 85% without condensate
For storage 10 … 85% without condensate
This unit is compliant to the DIN EN 60068-2-29 (shock and bump) testing
specification
Vibration and shock resistance
EN 60721-3-5 (06.1998), class 5M2 for HDD version, class 5M3 (terrestrial
vehicles) for SSD version, 5 hours of noise-type vibrations; 3.6 g rms and 30 g
peak value
The device can be put into operation and used under the following conditions. Failure to observe any
one of these conditions will invalidate the warranty. ads-tec cannot be held liable for any damages
arising from improper use and handling.
For verification and compliance with these guidelines, the following
harmonized standards have been applied:
EN 55022
EN 55024
EN 61000-6-2
EN 61000-6-4
EN 60950-1
For verification against environmental influences, the following standards are
complied:
EN 60068-2-6 (vibration test, sinusoidal)
EN 60068-2-27 (shock test)
Information:
For full compliance with the EMC legislation, the connected components and
the cable connections must also meet these requirements. Therefore
shielded data cables with shielded plugs have to be used and installed
according to the instructions in the operating manual.
Information:
By using the EC conformity declaration in this document, you can find
detailed information about the standards applicable to this device.
All users must read this manual and have access to it at all times.
Assembly, commissioning and operation may only be performed by qualified
and trained personnel.
The safety notices and the manual itself must be observed by all persons who
work with this device.
At the installation site the valid guidelines and regulations for accident
prevention must be observed.
The manual contains the most important instructions on how to use this device
in a safe way.
Appropriate storage, proper transport, installation and commissioning, as well as
careful operation are prerequisites for ensuring safe and proper operation of the
device.
The device can be cleaned by using a soft cloth and a commercially available
glass cleaning agent (e.g. Sidolin) with low alcohol content.
ATTENTION
To prevent damage to the device, all cable lines
(power supply, interface cables) must be only be
connected while the device is switched off.
ATTENTION
The device may only be switched on after
acclimatising to the ambient temperature in order
to avoid condensate accumulation.
To avoid overheating in operation: The device
must not be exposed to direct radiation by
sunlight or any other heat source.
2 Operating and safety instructions
The device operates under electrical voltage and contains highly sensitive components. Intervention by
the user is required only for connecting the power supply lines. Should any further modifications be
required, it is necessary to consult either with the manufacturer directly or with service personnel
authorised by the manufacturer. The device must be de-energised during work. Appropriate measures
must be taken to prevent electrostatic discharges on components. If the device is opened up by an
unauthorised person, the user may be subject to hazards and the warranty is invalidated.
2.1 Operating location
The VMT control system is designed for use on support arm systems, wall and table mounting or on
moving transport equipment (commissioning trolleys, forklifts or similar). You have to take care that the
environmental conditions specified in the technical data are met. Use in non-specified environments,
i.e., on board ships, in explosive atmospheres or at extreme elevations, is prohibited.
The more the battery is exposed to higher temperatures, the faster it ages.
ATTENTION
Danger of explosion if using incorrect battery
types.
ATTENTION
Danger of explosion if using incorrect battery
types.
ATTENTION
Lithium batteries should not be exposed to fire,
soldered, recharged, opened, short-circuited,
reversed or heated above 100 °C and they should
be disposed of properly as well as protected
against sunlight, moisture and condensation.
2.2 Damage due to improper use
Should the control system have evident signs of damages caused, e.g., by improper operation or
storage conditions or due to improper use or handling, the device must be shut down immediately.
Ensure that it is secured against being started up accidentally.
2.3 Warranty / repairs
During the device warranty period, any repairs must only be performed by the manufacturer or by
service personnel that has been authorised by the manufacturer.
2.4 Treatment and disposal of lithium batteries
This device contains a lithium battery for supplying the system clock with power as long as the supply
voltage is not connected. The battery has a life cycle of 3 - 5 years depending on which load is applied.
Lithium batteries may only be replaced by the same type, or by a type recommended by the
manufacturer.
The used lithium battery should be disposed of in accordance with local legal regulations.
All installation work performed on the device must
be performed only under safe, secure and deenergised conditions. The provisions of DIN VDE
0105 apply
Information:
Always adhere to the safety measures applicable when handling components at
risk of being damaged by electrostatic discharges.
The provisions of DIN EN 61340-5-1 / DIN EN 61340-5-2 apply