1.8 Scope of delivery ............................................................................................................................... 6
1.9 Device features .................................................................................................................................. 7
2Operating and safety instructions ................................................................................... 9
5.4 Status displays ................................................................................................................................ 26
8.1.5 USB lock ...................................................................................................................................... 36
Indicates an imminent danger. If not avoided,
death or severe injury will result.
WARNING
Indicates a possible danger. If not avoided, death
or severe injury could result.
CAUTION
Indicates a possible danger. If not avoided, light
or minor injuries could result.
ATTENTION
Indicates a possibly damaging situation. If not
avoided, the system or something in its
surroundings could be damaged.
Information:
The symbol "Information" indicates notes, terms and/or conditions that strictly
need to be observed to ensure optimised and/or zero-defect operation. Tips
and suggestions for the efficient use of the device and software optimisation
are also provided.
1 Notes
1.1 Relevant device documentation
The following documents are decisive to unit setup and operation:
User manual (this documentation):
Contains information for installation, commissioning and operation of the device along with technical
data of the device hardware.
Website
You can download drivers, software, user manuals, leaflets and flyers from the Download section of our
website www.ads-tec.de.
1.2 Explanation of the warning notices
1.3 Data, figures and modifications
All texts, data and figures are non-binding. We reserve the right to make changes that serve technical
development. At the point in time that the products leave our premises, they comply with all currently
applicable legal requirements and regulations. The operator/operating company is independently
responsible for compliance with and observance of any subsequently introduced technical innovations
or new legal requirements, as well as for all usual obligations of the operator/operating company.
It is noted that any software and/or hardware trademarks and any company brand names as mentioned
in this documentation are all subject to the general trademark, brand name and patent protection rights.
Windows®, Windows® CE are registered trademarks of Microsoft Corp.
Intel®, Pentium®, Atom™, Core™2 are registered trademarks of Intel Corp.
RITTAL® is a registered trademark of the Rittal Werk Rudolf Loh GmbH & Co. KG.
Any other additional trademarks and/or brand names herein, be they domestic or international, are
hereby duly acknowledged.
1.5 Copyright
This manual including all images contained herein is subject to copyright. Third-party use of this manual
that infringes on the copyright terms is forbidden. Reproduction, translation, or electronic and
photographic archiving or alteration requires the express written consent of ads-tec GmbH.
Infringements or violations shall result in an obligation to provide compensation for damages.
in operation -20 to +55°C*
(*only with Flash SSD)
for storage -30 to +75°C
Temperature for OPC8013/8015 devices
in operation +5 to +45°C
in operation -20 to +60°C*
(*only with Flash SSD, automotive hard disk or 2.5" Industrial SSD)
for storage -30 to +65°C
for storage -30 to +75°C*
(*only with Flash SSD, automotive hard disk or 2.5" Industrial SSD)
Temperature for OPC8022 device
in operation +5 to +45°C
for storage -20 to +60°C
Humidity
in operation 10 to 85% without condensate
for storage 10 to 85% without condensate
Vibration
in operation 1 G, 10 to 500 Hz
(DIN EN 60068-2-6)
Shock resistance
in operation 5 G, with a 30 ms half-cycle
(DIN EN 60068-2-27)
1.6 Environmental conditions
The device can be put into operation and used under the following conditions. Failure to observe any
one of these conditions will invalidate the warranty. ads-tec cannot be held liable for any damages
arising from improper use and handling.
This device is compliant with the CE mark test requirements as defined in the
European test standards EN 55022 and EN 50082-2
This device is compliant with the DIN EN 60950 (VDE0805, IEC950) testing
specifications on “Information technology equipment – Safety"
This device is compliant with the DIN EN 60068-2-6 testing specifications
(sinusoidal vibration)
The device is compliant with the DIN EN 60068-2-27 testing specifications
(shock resistance test)
Information:
A corresponding declaration of conformity is available for competent
authorities at the manufacturer and can be viewed upon request.
For full compliance with the EMC legislation, all components and cables
used for device connection must also be compliant with these requirements.
It is therefore necessary to employ BUS and LAN cables with shielded
connectors and these must be installed as per the instructions contained in
the user manual.
1 x device
1 x 3-pole lead-through connector from Phoenix Contact; 3-pole screwable 3.81
OPC7 (already plugged into device socket)
QuickStartGuide
Optional scope of delivery:
Operating system
1.7 Standards
This device is compliant with the provisions and safety objectives of the following EU directives:
1.8 Scope of delivery
Please check that all of the following components are contained in the packaging:
Proven many times over in rough environments, Panel PCs from ads-tec create clarity and precision in
a new form. Optimised in every detail - with multi-touch operation and rear service access for simple
and safe replacement of all components. In wide-screen format in four different sizes, reduced to the
essential without compromise, powerful and with long-term availability.
All users must read this manual and have access to it at all times.
Installation, commissioning and operation may only be performed by qualified
and trained personnel.
The safety notices and the manual itself must be observed by all persons who
work with this device.
At the installation site the valid guidelines and regulations for accident
prevention must be observed.
The manual contains the most important instructions on how to use this device
in a safe way.
Appropriate storage, proper transport, installation and commissioning, as well as
careful operation are prerequisites for ensuring safe and proper operation of the
device.
The device can be cleaned by using a soft cloth and a commercially available
glass cleaning agent (e.g. Sidolin) with low alcohol content.
ATTENTION
To prevent damage to the device, all cable lines
(power supply, interface cables) must be only be
connected while the device is switched off.
ATTENTION
The device may only be switched on after
acclimatising to the ambient temperature in order
to avoid condensate accumulation. This also
applies if the device is exposed to extreme
temperature fluctuations.
To avoid overheating in operation: The device
must not be exposed to direct radiation by
sunlight or any other light source.
ATTENTION
If the device is installed in a panel, casing or
similar, it must be ensured that no heat
accumulation occurs. The maximum permissible
ambient temperature must not be exceeded.
2 Operating and safety instructions
The device operates under electrical voltage and contains highly sensitive components. Intervention by
the user is required only for connecting the power supply lines. Should any further modifications be
required, it is necessary to consult either with the manufacturer directly or with service personnel
authorised by the manufacturer. The device must be de-energised during work. Appropriate measures
must be taken to prevent electrostatic discharges on components. If the device is opened up by an
unauthorised person, the user may be subject to hazards and the warranty is invalidated.
2.1 Operating location
The control system is designed for use inside a switching cabinet. Make certain that the specified
environmental conditions are maintained at all times. Use in non-specified environments, i.e., on board
ships, in explosive atmospheres or at extreme elevations, is prohibited.
The more the battery is exposed to higher
temperatures, the faster it ages.
WARNING
Danger of explosion if using incorrect battery
types.
WARNING
Lithium batteries should not be exposed to fire,
soldered, recharged, opened, short-circuited,
reversed or heated above 100 °C and they should
be disposed of properly as well as protected
against sunlight, moisture and condensation.
2.2 Damage due to improper use
Should the control system have evident signs of damages caused, e.g., by improper operation or
storage conditions or due to improper use or handling, the device must be shut down immediately.
Ensure that it is secured against being started up accidentally.
2.3 Warranty / repairs
During the device warranty period, any repairs must only be performed by the manufacturer or by
service personnel that has been authorised by the manufacturer.
2.4 Treatment and disposal of lithium batteries
This device contains a lithium battery for supplying the system clock with power as long as the supply
voltage is not connected. The battery has a life cycle of 3 - 5 years depending on which load is applied.
Lithium batteries may only be replaced by the same type, or by a type recommended by the
manufacturer.
The used lithium battery should be disposed of in accordance with local legal regulations.
To avoid overheating in operation: The device
must not be exposed to direct radiation by
sunlight or any other light source.
If the device is installed in a panel, casing or
similar, it must be ensured that no heat
accumulation occurs. The maximum permissible
ambient temperature must not be exceeded.
Devices with data drives must only be installed
vertically. Any deviation must be arranged with
ads-tec GmbH.
IP 65 on the front is only achieved with proper
installation.
ATTENTION
When selecting the enclosure for integration, the
total power dissipation of the system including
installed PCBs must be taken into account. The
housing must be dimensioned so that the max.
permissible ambient temperature is not
exceeded.
3 Installation
3.1 Installation option
This device is designed for integration. For installation and operation reasons (connector access), the
installation location must be accessible from the rear. The wall thickness of the installation location must
be between 2 and 13 mm. We recommend at least 3 mm for proper installation with IP65 on the front.
Installation can be performed with a 2mm Allen key.