ADS Environmental Services QR 775015 A0 User Manual

ADS® PrimeLog® User Manual
ADS LLC
4940 Research Drive
Huntsville, Alabama 35805
Telephone: 1-800-430-3366 / Fax: 1-800-430-6633
www.adsenv.com
i
ADS PrimeLog User Manual
Copyright © 2009 ADS® LLC. All rights reserved.
ADS® is a registered trademark of ADS LLC. PrimeWorks® and PrimeLog® are registered trademarks of Primayer Limited. Microsoft® and Windows® are registered trademarks of Microsoft Corporation.
All other brand and product names are trademarks or registered trademarks of their respective holders.
Notice of Proprietary Information
The information contained herein represents the latest information available at the time of publication. ADS reserves the right to make any changes or modifications to the content of this document, without notice, to reflect the latest changes to the equipment. No part of this document may be reproduced in any form without the written consent of ADS.
CAUTION: This product contains Lithium batteries. Please refer to Appendix 3: Important Notice - Air- Freighting This Product on page 27 before Air­Freighting Loggers.
ii
ADS PrimeLog User Manual
Table of Contents
Chapter 1 Introduction................................................................................................ 1
System Features.......................................................................................... 2
Logging Range Features........................................................................ 2
Main Features........................................................................................ 2
Logging Features................................................................................... 2
Flow and Pressure Logging................................................................... 3
Special Features.................................................................................... 3
Logger Types......................................................................................... 4
ADS No-Hassle Warranty and Return Policy............................................. 5
New Product Warranty.......................................................................... 5
Replacement or Loaner Equipment....................................................... 5
Shipping................................................................................................ 5
Product Returns..................................................................................... 6
Chapter 2 System Overview........................................................................................7
PrimeLog..................................................................................................... 8
Auxiliary Battery Unit........................................................................... 9
Auxiliary Battery/Communications Adaptor........................................ 9
Chapter 3 Hardware Connections.............................................................................10
Sealing....................................................................................................... 11
Polarization............................................................................................... 12
PrimeLog Input Connections .................................................................... 13
Digital Inputs....................................................................................... 13
Internal Pressure Transducer............................................................... 13
Analog Inputs...................................................................................... 14
Communication Link.......................................................................... 14
Chapter 4 Installation and Use..................................................................................15
Logger Setup............................................................................................. 16
Logger Use................................................................................................ 17
Chapter 5 Interfacing .................................................................................................18
Quadrina Insertion Meters......................................................................... 19
The Quadrina Range........................................................................... 19
Volumetric Flow Measurement .......................................................... 19
Probe Calibration................................................................................ 19
Logger Configuration.......................................................................... 20
Other Flow Meters.................................................................................... 21
iii
ADS PrimeLog User Manual
Chapter 6 Appendices................................................................................................22
Appendix 1: Meter Scaling Tables........................................................... 23
Elster/Kent Helix & Domestic Meters................................................ 23
Schlumberger/Actaris/Stream Domestic & Helix Meters................... 23
Sensus (Socam/Meinecke).................................................................. 24
Appendix 2: Specifications...................................................................... 25
Appendix 3: Important Notice - Air-Freighting This Product.................. 27
Chapter 7 Index………… ............................................................................................28
iv
C H A P T E R 1

Introduction

PrimeLog® is a family of advanced submersible data loggers, designed specifically for applications in the water industry. Common applications include the following:
District, residential, and leakage flow monitoring Network analysis Pressure monitoring PRV (pressure reducing valve) monitoring
ADS PrimeLog User Manual
Open channel flow monitoring Reservoir and borehole depth measurement
The different loggers offer one, two, or four data input channels. This manual describes the operation of the PrimeLog in general terms. Therefore, some material may not be applicable to all loggers.
1
ADS PrimeLog User Manual

System Features

Logging Range Features

Standard (non-modem) Logger 1F 1A 1P 2i 2 4 4i
Total number of channels 1 1 1 2 2 4 4 Total number of bi-directional flow
channels Number of analog channels (for
transducer, voltage, or current input) Number of internal pressure channels 1 1 2 Pressure / analog channel accuracy (%) ±0.1 ±0.5 or
1 1 1 2 2
1 1 2
±0.1 ±0.1 ±0.1 ±0.1
±0.1

Main Features

1-, 2-, or 4-channel models Submersible to IP68 5-year battery life (see note below) Extremely robust Small size (fits in small locations) Serviceable/maintainable
Note: The battery packs used for PrimeLog data loggers are designed to last for five years, based on a standard configuration. However, the data logger configuration and usage deemed appropriate for the current application will affect the actual battery life. Therefore, ADS does not guarantee that all batteries will maintain a five-year battery life in all situations.

Logging Features

Wide range of measurement intervals
1 second to 24 hours
Setting different intervals for each individual channel
2
Variety of measurement modes
Cyclical
Designated time period
Memory limited (stops logging when memory is full)
Multiple data collection options
All data
Since last collection
Defined date range
Substantial data storage
Standard: 128K RAM (approximately 1 year at 15-minute interval)
Optional: 256K, 512K, and 1M

Flow and Pressure Logging

ADS PrimeLog User Manual
Logs data from all flow meters (e.g., Kent, Meinecke (Socam),
Schlumberger, ABB Kent-Taylor, and Quadrina)
Logs bi-directional flow Logs directly from combination meters Supports internal or external transducer Supports pressure accuracy options to +0.1% (meets the Water
Research Center code of practice for network analysis)

Special Features

Supports multiple analog inputs: pressure and depth sensors 4-20mA
voltage (various ranges)
Powers Kent HRP/PU100 pulse units directly Stores Quadrina calibration data internally: 10-point calibration
velocity profile and blockage factor
3

Logger Types

The following table includes the types of loggers available:
ADS PrimeLog User Manual
1F 1P 2i 2 4
Flow Pressure Flow +
Pressure
2-channel 4-channel
Digital input Analog input
Internal pressure transducer
4
ADS PrimeLog User Manual

ADS No-Hassle Warranty and Return Policy

The following sections detail the hassle-free warranty and return policy for the ADS PrimeLog.

New Product Warranty

ADS will repair or replace any PrimeLog equipment (supplied by ADS) that is defective in materials and/or workmanship for up to two (2) years following the date of shipment from ADS. To make a warranty claim, the customer should simply call ADS at (256) 430-3366 or contact the ADS Support Center toll-free at (877) 237-9585. The ADS Client Services Agent will assign a Return Materials Authorization (RMA) to the customers claim immediately.
The customer shall return a defective unit or part to ADS for troubleshooting and repair or replacement within 10 days with the RMA.

Replacement or Loaner Equipment

For a defective part, ADS will ship a replacement part immediately once the customer makes an initial claim. However, if ADS does not receive the defective part within 30 days or testing concludes that the part experienced excessive wear and tear or abuse for the period of use, ADS will bill the customer for the replacement part.
For a defective unit, at the customers request, ADS will ship a temporary (loaner) unit to the customer at the time of the initial claim. However, if ADS does not receive the temporary unit from the customer within 15 days of receiving the repaired or replacement unit or testing concludes that the unit experienced excessive wear and tear or abuse for the period of use, ADS will bill the customer for the temporary unit.

Shipping

The customer must pay to ship defective equipment to ADS for repair or replacement. However, ADS will incur the costs for shipping the repaired or replacement equipment back to the customer using the same priority shipment procured by the customer upon returning the defective equipment to ADS.
5

Product Returns

If the customer is not satisfied with the performance of the PrimeLog, the customer may return the equipment within 30 days for a full refund, provided the condition of the equipment is in the same condition as sold, except for expected or normal wear and tear for the period of use.
ADS PrimeLog User Manual