PrimeLog® is a family of advanced submersible data loggers, designed
specifically for applications in the water industry. Common applications
include the following:
Open channel flow monitoring
Reservoir and borehole depth measurement
The different loggers offer one, two, or four data input channels. This manual
describes the operation of the PrimeLog in general terms. Therefore, some
material may not be applicable to all loggers.
1
ADS PrimeLog User Manual
System Features
Logging Range Features
Standard (non-modem) Logger 1F 1A 1P 2i 2 4 4i
Total number of channels 1 1 1 2 2 4 4
Total number of bi-directional flow
channels
Number of analog channels (for
transducer, voltage, or current input)
Number of internal pressure channels 1 1 2
Pressure / analog channel accuracy (%) ±0.1 ±0.5 or
1 1 1 2 2
1 1 2
±0.1 ±0.1 ±0.1 ±0.1
±0.1
Main Features
1-, 2-, or 4-channel models
Submersible to IP68
5-year battery life (see note below)
Extremely robust
Small size (fits in small locations)
Serviceable/maintainable
Note: The battery packs used for PrimeLog data loggers are designed
to last for five years, based on a standard configuration. However, the
data logger configuration and usage deemed appropriate for the current
application will affect the actual battery life. Therefore, ADS does not
guarantee that all batteries will maintain a five-year battery life in all
situations.
Logging Features
Wide range of measurement intervals
1 second to 24 hours
Setting different intervals for each individual channel
2
Variety of measurement modes
Cyclical
Designated time period
Memory limited (stops logging when memory is full)
Multiple data collection options
All data
Since last collection
Defined date range
Substantial data storage
Standard: 128K RAM (approximately 1 year at 15-minute interval)
Optional: 256K, 512K, and 1M
Flow and Pressure Logging
ADS PrimeLog User Manual
Logs data from all flow meters (e.g., Kent, Meinecke (Socam),
Schlumberger, ABB Kent-Taylor, and Quadrina)
Logs bi-directional flow
Logs directly from combination meters
Supports internal or external transducer
Supports pressure accuracy options to +0.1% (meets the Water
Research Center code of practice for network analysis)
Special Features
Supports multiple analog inputs: pressure and depth sensors 4-20mA
voltage (various ranges)
Powers Kent HRP/PU100 pulse units directly
Stores Quadrina calibration data internally: 10-point calibration
velocity profile and blockage factor
3
Logger Types
The following table includes the types of loggers available:
ADS PrimeLog User Manual
1F 1P 2i 2 4
Flow Pressure Flow +
Pressure
2-channel4-channel
Digital input
Analog input
Internal pressure transducer
4
ADS PrimeLog User Manual
ADS No-Hassle Warranty and Return Policy
The following sections detail the hassle-free warranty and return policy for the
ADS PrimeLog.
New Product Warranty
ADS will repair or replace any PrimeLog equipment (supplied by ADS) that is
defective in materials and/or workmanship for up to two (2) years following
the date of shipment from ADS. To make a warranty claim, the customer
should simply call ADS at (256) 430-3366 or contact the ADS Support Center
toll-free at (877) 237-9585. The ADS Client Services Agent will assign a
Return Materials Authorization (RMA) to the customer’s claim immediately.
The customer shall return a defective unit or part to ADS for troubleshooting
and repair or replacement within 10 days with the RMA.
Replacement or Loaner Equipment
For a defective part, ADS will ship a replacement part immediately once the
customer makes an initial claim. However, if ADS does not receive the
defective part within 30 days or testing concludes that the part experienced
excessive wear and tear or abuse for the period of use, ADS will bill the
customer for the replacement part.
For a defective unit, at the customer’s request, ADS will ship a temporary
(loaner) unit to the customer at the time of the initial claim. However, if ADS
does not receive the temporary unit from the customer within 15 days of
receiving the repaired or replacement unit or testing concludes that the unit
experienced excessive wear and tear or abuse for the period of use, ADS will
bill the customer for the temporary unit.
Shipping
The customer must pay to ship defective equipment to ADS for repair or
replacement. However, ADS will incur the costs for shipping the repaired or
replacement equipment back to the customer using the same priority shipment
procured by the customer upon returning the defective equipment to ADS.
5
Product Returns
If the customer is not satisfied with the performance of the PrimeLog, the
customer may return the equipment within 30 days for a full refund, provided
the condition of the equipment is in the same condition as sold, except for
expected or normal wear and tear for the period of use.
ADS PrimeLog User Manual
6
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.