QUICK REFERENCE GUIDE
Programming of the ADS Enigma
The ADS Enigma® is a state-of-the-art digital correlation logging system for determining the
location of leaks in buried water pipes. Enigma combines noise logging and noise correlation
into one operation to provide improved operational eciency.
1
2
From the PC, run the Enigma
software by clicking on the
desktop icon or programs menu.
These two buttons are the
logger Programming and
Readback buttons.
(The Enigma case lid must be
closed when programming or
reading back loggers via the
software.)
ADS Enigma Pod -
Installation on Water Meter.
The screen should indicate
that it has found all the
loggers in the case and give
any relevant warnings.
3
4
5
Ensure the USB communications
cable is connected. Click on the
Program button which will
produce the following progress
box.
The Programming wizard will
appear and is usually set for the
default use of Timed Logging
(overnight) as shown.
The settings shown are those
recommended by Primayer and
used by many users.
Click on Program.
Continued on reverse side.
© 2009 ADS LLC. All Rights Reserved. QR 775022 A0
![](/html/a4/a4ea/a4ea0e93be54657381f595cd06fe875c051e37c40f71bc7fec37c2f5c5425523/bg2.png)
6
QUICK REFERENCE GUIDE
The Programming wizard indicates the loggers it
has found and successfully programmed.
The status screen indicates that the loggers are
waiting to record leak noise data.
The loggers have been
7
The ADS Enigma Operating Manual can
be Downloaded Online at
www.adsenv.com/manuals.
successfully programmed and
are ready for deployment.
4940 Research Drive - Huntsville, AL 35805 - 800.633.7246 www.adsenv.com