Manual Rev.: 2.00
Revision Date: August 7, 2013
Part No: 50-1Z124-1000
Advance Technologies; Automate the World.
Page 2
Revision History
RevisionRelease DateDescription of Change(s)
2.002013/08/07Initial release
iiRevision History
Page 3
XMC-E540
Preface
Copyright 2013 ADLINK Technology, Inc.
This document contains proprietary infor mation protected by cop yright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form
without prior written permission of the manufacturer.
Disclaimer
The information in this document is subject to change without prior
notice in order to improve reliability, design, and function and does
not represent a commitment on the part of the manufact ur er.
In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or
inability to use the product or documentation, even if advised of
the possibility of such damages.
Environmental Responsibility
ADLINK is committed to fulfill its social responsibility to global
environmental preservation through compliance with the European Union's Restriction of Hazardous Substances (RoHS) directive and Waste Electrical and Electronic Equipment (WEEE)
directive. Environmental protection is a top priority for ADLINK.
We have enforced measures to ensure th at our products, manufacturing processes, components, and raw materials have as little
impact on the environment as possible. When produ ct s ar e at th eir
end of life, our customers are encouraged to dispose of them in
accordance with the product disposal and/or recovery programs
prescribed by their nation or company.
Trademarks
Product names mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks
of their respective companies.
Preface iii
Page 4
Using this Manual
Audience and Scope
The XMC-E540 User’s Manual is intended for hardware
technicians and systems operators with knowledge of installing,
configuring and operating industrial grade computer systems.
Manual Organization
This manual is organized as follows:
Chapter 1, Introduction: Introduces the XMC-E540, its features,
The XMC-E540 is a dual-port 10GBASE-T Ethernet XMC module
with equipped with an Inte® Ethernet Controller X540. Featured
are dual RJ-45 copper ports supporting 10G/1000/100BASE-T
with auto-negotiation, jumbo frames up to 15.5KB, TCP/UDP segmentation, IPv6 IP/TCP, IP/UDP receive checksum offload, FCoE
Tx/Rx CRC offload, and 256KB FCoE transmit segmentation. The
XMC-E540 is compliant with the VITA 42.3-2006 XMC PCI
Express Protocol Layer Standard.
1.2Features
X Compliant with VITA 42.3 XMC standard with XMC.3 con-
nector
X Dual-port Intel® 10Gigabit Ethernet Controller X540-AT2
X 10G/1G/100Mbps copper PHYs integrated on-chip
X Jumbo frames up to 15.5KB
X TCP/UDP segmentation, IPv6 IP/TCP, IP/UDP receive
checksum offload
X FCoE Tx/Rx CRC offload, 256KB FCoE transmit segmenta-
tion
X Compliant with PCI Express Base Specification Rev. 2.1
(5GT/s)
X Compatible with PCIe x1, x2, x4, x8 lanes
X Dual RJ-45 copper ports
X Backward compatible with 1000BASE-T by auto-negotiation
X Preboot Execution Environment (PXE) support
XMC-E540
Introduction 1
Page 14
1.3Block Diagram
MDI0
MDI1
Intel X540
PCIe x1 / x2 / x4 / x8
Figure 1-1: XMC-E540 Functional Block Diagram
2Introduction
Page 15
XMC-E540
1.4Package Contents
The XMC-E540 is packaged with the following components. If any
of the items on the contents list are missing or damaged, retain the
shipping carton and packing material and contact the dealer for
inspection. Please obtain authorization before returning any product to ADLINK. The packing contents of the XMC-E540 are
non-standard configurations and may vary depending on customer
requests.
X XMC-E540 module
X ADLINK All-in-One DVD
X User’s manual
This product must be protected from static discharge and
physical shock. Never remove any of the components
CAUTION:
except at a static-free workstation. Use the anti-static bag
shipped with the product when putting the board on a surface. Wear an anti-static wrist strap properly grounded on
one of the system's ESD ground jacks when installing or
servicing system components.
Introduction 3
Page 16
This page intentionally left blank.
4Introduction
Page 17
XMC-E540
2Specifications
2.1XMC-E540 Module
StandardsVITA 42.3-2006 XMC PCI Express Protocol Layer Standard
Form Factor• IEEE P1386, Standard XMC.3
• 74 mm x 149 mm x 8.2 mm (single width)
ControllerIntel® Ethernet Controller X540-AT2
• Dual port 100Mb/1000Mb/10Gb data rate
• Intel® Virtualization Technology for Connectivity (VMDq,
SR-IOV)
• Fiber Channel over Ethernet
• MACsec IEEE 802.1 AE
• IEEE 1588
• Intel® Data Direct I/O Technology
• Intelligent Offloads
• Storage Over Ethernet (iSCSI, FCoE, NFS)
Interface• PCI Express base specification 2.1 (2.5GT/s or 5GT/s)
• Supports PCI Express x1, x4, x8 lanes
• 64-bit address support for systems using more than 4 GB
of physical memory
I/O• Two RJ-45 10G/1000/100BASE-T ports
• Auto-negotiation of 10 Gb/s, 1 Gb/s, 100Mb/s mode
OS
Compatibility
Environmental • Operating Temperature: 0°C to 60°C (with forced air flow)
EMI• CE EN55022
• Microsoft Windows 7 64-bit
• Microsoft® Windows® Server 2003 R2 (32-bit x86)
• Microsoft® Windows® Server 2008 64-bit
• Red Hat Enterprise Linux 6 x86
• Other OS support upon request
• Storage Temperature: -40°C to 85°C
• Humidity: 95%@60°C non-condensing
• Vibration: Operating 2Grms, 5-500Hz
• FCC Class A
Specifications are subject to change without prior notice.
NOTE:
NOTE:
Specifications 5
Page 18
2.2Intel® Ethernet Controller X540-AT2
The following section describes the features and functions of
Intel® Ethernet Controller X540-AT2
X 10 GbE/1 GbE/100 Mb/s copper PHYs integrated on-chip
X Support for jumbo frames of up to 15.5 KB
X Flow control support: send/receive pause frames and
receive
X FIFO thresholds
X Statistics for management and RMON
X 802.1q VLAN support
X TCP segmentation offload: up to 256 KB
X IPv6 support for IP/TCP and IP/UDP receive checksum
offload
X Fragmented UDP checksum offload for packet reassembly
X Message Signaled Interrupts (MSI)
X Message Signaled Interrupts (MSI-X)
X Interrupt throttling control to limit maximum interrupt rate
and improve CPU usage
X Flow Director (16 x 8 and 32 x 4)
X 128 transmit queues
X Receive packet split header
X Receive header replication
X Dynamic interrupt moderation
X DCA support
X TCP timer interrupts
X No snoop
X Relaxed ordering
X Support for 64 virtual machines per port (64 VMs x 2
queues)
X Support for Data Center Bridging (DCB);(802.1Qaz,
X 802.1Qbb, 802.1p)
X PCIe base specification 2.1 (2.5GT/s or 5GT/s)
X Bus width - x1, x2, x4, x8
6Specifications
Page 19
XMC-E540
2.3Power Consumption
The power consumption data of the XMC-E540 was measured
installed in an ADLINK cPCI-6510 carrier blade using a Spirent
SmartBits network performance analysis system.
Power Consumption
Engine ClockCurrent @ 5VPower (W)
Idle Load0.44 A2.2 W
Max. Load1.50 A7.5 W
Table 2-1: XMC-E540 Power Consumption
Specifications 7
Page 20
This page intentionally left blank.
8Specifications
Page 21
3Board Interfaces
This chapter illustrates the board layout, connector pin
assignments, and switch settings to familiarize users with the
XMC-E540.
1. Remove the XMC slot filler faceplate from the front panel
of the host board.
2. Insert the faceplate of the XMC module into the XMC slot
in the front panel of the host board.
3. Carefully align the male connectors of the XMC module
(component-side down) to the female connectors of the
host board and firmly press down.
4. Secure the XMC module with the four screws provided
from the bottom side of the host board.
XMC-E540
Getting Started 13
Page 26
4.2Driver Installation
The XMC-E540 drivers can be found on the ADLINK All-In-One
DVD at X:\XMC\XMC-E540\LAN, or at the ADLINK website (http://www.adlinktech.com). Driver installation procedures for Windows 7 are described below.
1. Install the Windows operating system before installing any
driver. Most standard I/O device drivers are installed during
Windows installation.
2.
Install the LAN drivers by extracting and running the executable file in
We recommend using the drivers provided on the ADLINK
All-in-One DVD or downloaded from the ADLINK website to
ensure compatibility.
...\LAN\Intel_Network_Adapter_AllOS_v16.6.zip
14Getting Started
Page 27
XMC-E540
Important Safety Instructions
For user safety, please read and follow all instructions,
WARNINGS, CAUTIONS, and NOTES marked in this manual
and on the associated equipment before handling/operating the
equipment.
X Read these safety instructions carefully.
X Keep this user’s manual for future reference.
X Read the specifications section of this manual for detailed
information on the operating environment of this equipment.
X When installing/mounting or uninstalling/removing
equipment:
Z Turn off power and u nplug any power cords/cables.
X To avoid electrical shock and/or damage to equipment:
Z Keep equipment away from water or liquid sources;
Z Keep equipment away from high heat or high humidity;
Z Keep equipment properly ventilated (do not block or
cover ventilation openings);
Z Make sure to use recommended voltage and powe r
source settings;
Z Always install and operate equipment near an easily
accessible electrical socket-outlet;
Z Secure the power cord (do not place any obje ct on /ove r
the power cord);
Z Only install/attach and operate equipment on stable
surfaces and/or recommended mountings; and,
Z If the equipment will not be used for long periods of time,
turn off and unplug the equipment from its power source.
Important Safety Instructions 15
Page 28
X Never attempt to fix the equipment. Equipmen t sho u ld on ly
be serviced by qualified personnel.
A Lithium-type battery may be provided for uninterrupted, backup
or emergency power.
Risk of explosion if battery is replaced with one of an incorrect
WARNING:
type. Dispose of used batteries appropriately.
X Equipment must be serviced by authorized technicians
when:
Z The power cord or plug is damaged;
Z Liquid has penetrated the equipment;
Z It has been exposed to high humidity/moisture;
Z It is not functioning or does not function according to the
user’s manual;
Z It has been dropped and/or damaged; and/or,
Z It has an obvious sign of breakage.
16Important Safety Instructions
Page 29
Getting Service
Contact us should you require any service or assistance.
ADLINK Technology, Inc.
Address: 9F, No.166 Jian Yi Road, Zhonghe District
New Taipei City 235, Taiwan