ADJ Par Z100 5K Users Manual

Page 1
PAR Z100 5K
©2017 ADJ Products, LLC all rights reserved. Information,
specications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis­claim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent as­sembly, installation, rigging, and operation of this product.
9/17
User Instructions
DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.
Date
09/27/17
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Document
Version
1 1.0
Software
Version
DMX
Channel
>
Mode
1/2/3 Initial Release
Notes
Page 2
Par Z100 5K General Instructions Par Z100 5K General Information
Unpacking: Thank you for purchasing the Par Z100 5K by ADJ Prod-
ucts, LLC. Every Par Z100 5K has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the ship­ping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are miss­ing, please contact our toll free customer support number for further instructions. Please do not return this unit to your dealer without con­tacting customer support rst.
Introduction: The Par Z100 5K is a DMX intelligent, zooming, LED
par fixture. The Par Z100 5K operates as a stand alone fixture. This fixture is suitable for theaters, studios, retail stores, and other similar
locations. For best results use fog or special effects smoke to enhance the beams projections.
Customer Support: ADJ Products, LLC provides a toll free cus-
tomer support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2941 E-mail: support@americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Par Z100 5K Features
• DMX-512 Protocol Compatible (3 DMX Channel Modes: 1 Channels, 2 Channels, & 3 Channels)
• 5-Pin XLR In/Out Connections
• powerCON In/Out Connections
• 5 Dimmer Curves (Standard, Stage, TV, Architectural, & Theatre)
• Digital Display for Address and Function Setting
• Gamma Correction Adjustment
• Dimming Frequency Adjustment
• Multiple Unit Power Linking (See page 18)
Par Z100 5K Warranty Registration
The Par Z100 5K carries a 2 year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase and war-
ranty. You may also register your product online at www. adjproducts. com. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) num­ber. If the unit is under warranty you must provide a copy of your proof of purchase invoice. Please contact ADJ Products, LLC cus­tomer support for a R.A. number.
Par Z100 5K Handling Precautions
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
During operation the housing may become extremely hot. Avoid touching the unit with bare hands while in use.
ADJ Products, LLC will not accept any liability for any resulting dam­ages caused by the non-observance of this manual or any unauthor-
ized modication to this unit.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 3ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 2
Page 3
Par Z100 5K Safety Precautions
Par Z100 5K DMX Set Up
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt­ age for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out­ doors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep­ tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 19 for cleaning details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits a marked change in performance.
Power Supply: The ADJ Par Z100 5K contains a automatic voltage
switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the cor­rect power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix­ture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): The Par Z100 5K can be controlled via DMX-512 proto-
col. The Par Z100 5K three DMX channel modes; 1 channel mode, 2 channel mode, & 3 channel mode. The DMX address is set electronically using the controls on the rear panel of the unit. Your unit and your DMX controller require a approved DMX-512 110 Ohm Data cable for data input and data output (Figure
1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use stan­dard 110-120 Ohm shielded cable (This cable may be purchased at almost all professional sound and
Figure 1
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 5ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 4
Page 4
Par Z100 5K DMX Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
Par Z100 5K DMX Set Up
lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
XLR Male Socket
1 Ground
Figure 3
DMX512 OT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
DMX +
DMX -
1 Ground
3 Hot
5-Pin XLR DMX Connectors.
This unit use 5-pin DMX-512 data
cables for DATA transmission. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are read­ily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Pin 4 - Do Not Use
Pin 5 - Do Not Use
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
When longer runs of cable are
nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 6 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 7
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
Figure 4
Page 5
Par Z100 5K System Menu
Par Z100 5K System Menu
System Menu: When making adjustments press ENTER to
conrm your setup then press and hold the MENU button
for at least 3 seconds. To exit without making any adjust-
ments press the MENU button. The display will lock after 30 seconds, press the MENU button for 3 seconds to unlock.
- DMX Address Setting.
1. Press the either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
2. The current address will now be displayed and ashing. Press the UP or DOWN buttons to nd your desired address. Press ENTER to set your desired DMX address.
- This will let select your desired DMX channel
mode.
1. Press the either the MENU button until is displayed, press ENTER. The current DMX channel mode will be displayed.
2. Press the UP or DOWN buttons to nd your desired DMX channel mode and press ENTER to conm and exit.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 9ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 8
Page 6
Par Z100 5K System Menu
Par Z100 5K System Menu
- This mode can be used as a precaution mode,
that in case the DMX signal is lost, interrupted, or power is lost, the operating mode chosen in the setup is the running
mode the xture will go into when the DMX signal is lost. You
can also set this as the operating mode you would like the unit to return to when power is applied.
1. Press the MENU button until is displayed, and either “BLND” or “HOLD” will be displayed beneath.
2. Press ENTER and the bottom choice will begin to ash. Use the UP or DOWN buttons to choose an operating mode you would like the unit to start up in when power is applied or the DMX signal is lost.
BLND (Blackout) - If the DMX signal is lost or interrupted, the unit will automatically go into stand by mode.
HOLD - If the DMX signal is lost the xture will stay in the last DMX setting. If power is applied and this mode is set, the unit will automatically go into the last DMX set up.
3. Press ENTER to conrm your desired set up.
- With this function you can adjust the dimming
frequency.
1. Press the MENU button until is displayed, press ENTER.
2. Use the UP or DOWN buttons to adjust the dimming frequency between 900hz, 1000hz, 1100hz, 1200hz, 1300hz, 1400hz, 1500hz, 2500hz, 4000hz, 5000hz, 10000hz, 15000hz, 20000hz, or 250000hz.
3. Once you have found your desired dimming frequency press ENTER to conrm.
- In this menu you are able to make gamma
corrections.
1. Press the MENU button until is displayed, press ENTER.
2. Use the UP or DOWN buttons to nd your desired gamma
correction.
- This will let select your desired dimmer curve.
1. Press the MENU button until is displayed, and press ENTER. 1 of 5 dimmer curves will be displayed. “ ” (standard), “ ” (stage), “ ” (TV), “ ” (Architectural), or “ ” (Theatre). See the dimmer curve chart on page 17 for
more info.
2. Press the UP or DOWN buttons to nd your desired dimmer curve and press ENTER to conm and exit.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 10
3. Once you have found your desired dimming frequency press ENTER to conrm.
- This function will reverse the display 180º.
1. Press the either the MENU button until is displayed, press ENTER.
2. Press the UP button to select “DSIP” to “ip” the display, or “DISP” to revert the display to normal.
3. Press ENTER to conrm.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 11
Page 7
Par Z100 5K System Menu
Par Z100 5K System Menu
- This function will allow you to manually adjust
each brightness, ne dimming, and strobing. Fine dimming
and strobing are only used with 3 channel mode.
1. Press the MENU button until is displayed, press ENTER.
2. Use the UP and DOWN buttons to scroll through the settings. Once you have found your desired function you would like to adjust press ENTER.
3. After you have pressed ENTER, use the UP and DOWN buttons to adjust the values. Once you have made your adjustments press ENTER to set them. Press the MENU button to exit.
- This function will run a self test program.
1. Press the MENU button until is displayed, press ENTER.
2. The xture will now run a self test. Press the MENU button to exit and quit the self test.
- With this function you can display the running
time of the unit.
1. Press the MENU button until is displayed, press ENTER.
2. The running time of the xture will now be displayed. Press MENU to exit.
- Use this function to display the Software version
of the unit.
1. Press the either the MENU button until is displayed, press ENTER.
2. The display will show the software version.
- With this function you can check the temperature
of the xture.
1. Press the MENU button until is displayed, press ENTER.
2. The xture temperature will now be displayed. Press MENU to exit.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 12 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 13
Page 8
Par Z100 5K DMX Operation Par Z100 5K Beam Angle Adjustment
Universal DMX Control: This function allows you to use a uni-
versal DMX-512 controller to control the dimmer, fine dimmer and strobe. A DMX controller allows you to create unique programs tai­lored to your individual needs.
1. The Par Z100 5K has 3 DMX channel modes; 1 channel mode, 2 channel mode, and 3 channel mode. See page 16 for a detailed description of the DMX values and traits.
2. To control your fixture in DMX mode, follow the set-up procedures on pages 5-7 as well as the set-up specifications that are included with your DMX controller.
3. Use the controller’s faders to control the various DMX fixture traits.
4. This will allow you to create your own programs.
5. Follow the instructions on page 9 to select your DMX channel mode and set your desired DMX address.
6. For longer cable runs (more than a 100 feet) use a terminator on the last fixture.
7. For help operating in DMX mode consult the manual included with your DMX controller.
To adjust the beam angle slide the beam angle adjuster located inside/in front of the lens. See diagram below.
The beam angle can be adjusted manually, between 9°/ 15°/ 20°/25°/ 30°.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 15ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 14
Page 9
Par Z100 5K 1 Channel Mode
DIMMER
Channel Value Function
Par Z100 5K Dimmer Curve Chart
1 DIMMER
0 - 255 0% - 100%
Par Z100 5K 2 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100% 2 SHUTTER/STROBE 0 - 31 LED OFF 32 - 63 LED ON 64 - 95 STROBING SLOW - FAST 96 - 127 LED ON 128 - 159 PULSE EFFECT 160 - 191 LED ON 192 - 223 RANDOM STROBE SLOW - FAST 224 - 255 LED ON
Par Z100 5K 3 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100% 2 0 - 255 DIMMING FINENESS 3 SHUTTER/STROBE 0 - 31 LED OFF 32 - 63 LED ON 64 - 95 STROBING SLOW - FAST 96 - 127 LED ON 128 - 159 PULSE EFFECT 160 - 191 LED ON 192 - 223 RANDOM STROBE SLOW - FAST 224 - 255 LED ON
100%
50%
10%
0%
Rise Time Down Time
0 Sec
0 sec Fade Time 1 sec Fade Time
Dimming Curve
Ramp Effect
0 0
Rise Time (ms) Down Time (ms) Rise Time (ms) Down Time (ms)
Standard (default) 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280
255 255
Time (ms)
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 16 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 17
Page 10
Par Z100 5K Dimensional Drawings
Par Z100 5K Fuse Replacement
10.82”/275mm
8.8”/224mm
9.75”/248mm
4.44”/113mm
19.33”/491mm
Par Z100 5K Installation
The unit should be mounted using a mounting clamp (not provided), axing it to the mounting bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration and slip­ping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable that can hold 12 times the weight of the unit when installing the xture. The equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
Par Z100 5K Multiple Unit Power Linking
With this feature you can connect the xtures to one another
using the powerCON input and output sockets. The quantity that
can be connected is 15 xtures maximum @ 120V and 25 xtures maximum @ 230V. After maximum xtures is met you will need to
use a new power outlet. NOTE: USE CAUTION WHEN POWER LINKING OTHER
FIXTURES TO THE PAR Z100 5K AS THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
Unplug the unit from any power source it may be connected to. Once the power has be disconnected, use a phillips head screw driver to unscrew the fuse holder located above the powerCON input. Remove the bad fuse and replace with a new one, and screw the fuse holder back in.
Par Z100 5K Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter­nal optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environ­ment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics with glass cleaner and a soft cloth every 20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every 30-60 days.
5. Always be sure to dry all parts completely before plugging the unit back in.
Par Z100 5K Trouble Shooting
Trouble Shooting: Listed below are a few common problems that you may encounter, with solutions.
No light output from the unit;
1. Be sure the external fuse has not blown. The fuse is located on the rear panel of the unit.
2. Be sure the fuse holder is completely and properly seated.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 18 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 19
Page 11
Par Z100 5K Notes Par Z100 5K Notes
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 20 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 21
Page 12
Par Z100 5K Warranty
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#) before sending back the product–please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
•LightingProducts=1-year(365days)LimitedWarranty(Such as: Special Effect Lighting, Intelligent
Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
•LaserProducts=1Year(365Days)LimitedWarranty(excluding laser diodes which have a 6 month
limited warranty)
•L.E.D.Products=2-year(730days)LimitedWarranty(excluding motors, PCB boards, and power supplies, which have a 1-year (365 day Limited Warranty) batteries which have a 180 day limited war-
ranty). Only the L.E.D.s carry a 2-year warranty (excludingStarTecSerieswhichacarriesa1Year
LimitedWarranty)
•ADJDMXControllers=2Year(730Days)LimitedWarranty(excluding faders and tact switches)
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 22
Par Z100 5K Specifications
Model: Par Z100 5K
Voltage: 100 - 240V, 50/60Hz
LED: 1 x 98W COB LED Power Consumption: 115W Power Linking: 15 Fixtures Max. @ 120V
25 Fixtures Max. @ 230V Dimensions: 19.33”(L) x 10.82”(W) x 8.75”(H) 491 x 275 x 224mm (with Bracket)
Weight: 8 Lbs. / 3.6 kgs. Beam Angle: 9/15/20/25/30 Degrees Fuse: 3.15 Amp Duty Cycle: None DMX: 3 DMX Channel Modes: 1/2/3 Color Temperature: 5700K Working Position: Any Safe, Secure Position Warranty: 2 Year (730 days)
Please Note: Specications and improvements in the design
of this unit and this manual are subject to change without any prior written notice.
Auto Sensing Voltage: This xture contains a automatic volt-
age switch, which will auto sense the voltage when it is plugged into the power source.
ADJ Products, LLC
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-2650 / Fax: 323-725-6100
Web: www.adj.com / E-mail: info@americandj.com
A.D.J. Supply Europe B.V.
Junostraat 2
6468 EW Kerkrade
Netherlands
service@adjgroup.eu / www.adj.eu
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99
Loading...