Adj PAR Z100 3k User Manual [ru]

User Instructions
A.D.J. Supply Europe B.V.
Junostraat 2
The Netherlands
www.adj.eu
A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 3K Instruction Manual Page 2
©2018 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies.
ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.
Date
Document
Version
Software
Version
DMX
Channel
Mode
Notes
09/26/17
1
1.0
1/2/3
Initial Release
01/02/18
2
1.2
1/2/3/4
Added: RDM Protocol Support, 4 CH
DMX Mode, Stage 2 Dimmer Curve,
& Default Settings System Menu
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 3K Instruction Manual Page 3
Contents
GENERAL INFORMATION ........................................................................................................................................................ 4
GENERAL INSTRUCTIONS ........................................................................................................................................................ 4
FEATURES ................................................................................................................................................................................ 4
HANDLING PRECAUTIONS ....................................................................................................................................................... 4
SAFETY PRECAUTIONS ............................................................................................................................................................ 5
DMX SET UP ............................................................................................................................................................................ 5
SYSTEM MENU ........................................................................................................................................................................ 6
DMX OPERATION .................................................................................................................................................................. 10
BEAM ANGLE ADJUSTMENT ................................................................................................................................................. 10
1 CHANNEL MODE ................................................................................................................................................................ 10
2 CHANNEL MODE ................................................................................................................................................................ 10
3 CHANNEL MODE ................................................................................................................................................................ 11
4 CHANNEL MODE ................................................................................................................................................................ 11
DIMENSIONAL DRAWINGS .................................................................................................................................................... 11
DIMMER CURVE CHART ........................................................................................................................................................ 12
DIMENSIONAL DRAWINGS .................................................................................................................................................... 12
INSTALLATION ....................................................................................................................................................................... 13
MULTIPLE UNIT POWER LINKING ......................................................................................................................................... 13
FUSE REPLACEMENT ............................................................................................................................................................. 13
CLEANING.............................................................................................................................................................................. 13
TROUBLE SHOOTING ............................................................................................................................................................. 13
SPECIFICATIONS .................................................................................................................................................................... 14
ROHS - A great Contribution to the Conservation of Environment ..................................................................................... 15
WEEE – Waste of Electrical and Electronic Equipment ........................................................................................................ 15
NOTES ................................................................................................................................................................................... 16
A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 3K Instruction Manual Page 4
INOZIONE GENERAL INFORMATION
Unpacking: Thank you for purchasing the Par Z100 3K by ADJ Products, LLC. Every Par Z100 3K has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are missing, please contact our toll-free customer support number for further instructions. Please do not return this unit to your dealer without contacting customer support first. Introduction: The Par Z100 3K is a DMX intelligent, zooming, LED par fixture. The Par Z100 3K also operates as a standalone fixture. This fixture is suitable for theaters, studios, retail stores, and other similar locations.
For best results use fog or special effects smoke to enhance the beams projections. Customer Support: If you encounter any problems, please contact your trusted American Audio shop. We
also offer the possibility, to contact us directly: You can contact us via our website www.adj.eu or via email:
support@adj.eu
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. Warning! This may cause severe eye damage. Avoid looking directly into the light source at all times!
GENERAL INSTRUCTIONS
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
FEATURES
• DMX-512 Protocol Compatible (4 DMX Channel Modes: 1 Channel, 2 Channels, 3 Channels, & 4 Channels)
• 5-Pin XLR In/Out Connections
PowerCON In/Out Connections
6 Dimmer Curve Modes
• Digital Display for Address and Function Setting
• Gamma Correction Adjustment
• Dimming Frequency Adjustment
• Multiple Unit Power Linking (See page 14)
HANDLING PRECAUTIONS
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
During operation the housing may become extremely hot. Avoid touching the unit with bare hands while in use. ADJ Products, LLC will not accept any liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to this unit.
A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 3K Instruction Manual Page 5
SAFETY PRECAUTIONS
For Your Own Personal Safety, Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit!
• To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required voltage for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce
the risk of electrical shock and fire in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between
this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product outdoors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed
upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 14 for cleaning details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits a marked change in performance.
DMX SET UP
Power Supply: The ADJ Par Z100 3K contains a automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX controller sends
DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture
to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To
ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Loading...
+ 11 hidden pages