specications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis­claim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indi­rect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
1/15
User Instructions
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Mega Flat Pak Plus Introduction
Mega Flat Pak Plus Features
Unpacking: Thank you for purchasing the Mega Flat Pak Plus by ADJ Products, LLC. Every Mega Flat Pak Plus has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during ship­ping. If the carton appears to be damaged, carefully inspect your x­ture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact our toll free customer support number for further instructions. Do not return this unit to your dealer without rst contacting customer support.
Introduction: The ADJ Mega Flat Pak Plus includes four of the poplu- lar ADJ Mega Par Profile Plus LED wash fixtures, three DMX connec­tor cables, and a soft carrying case to protect your Mega Par Profile Plus unit’s during transport and dust-free while storing. The Mega Par Profile Plus is a DMX intelligent, high powered LED par fixture. This xture can be used in a stand alone mode or connected in a Master/ Slave conguration. This wash has five operating modes: Sound Active mode, Auto mode, RGB + UV Dimmer mode, Static Color mode, and DMX control mode.
Customer Support: ADJ Products, LLC provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or sugges­tions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time. Voice: (323) 582-3322 Fax: (323) 582-3108 E-mail: support@americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - Mega Flat Pak Plus User Manual Page 2
• System Includes: 4 x Mega Par Profile Pluss, 3 x DMX Cables, and 1 x ADJ Carry Bag
• Five Operating Modes
• Electronic Dimming 0-100%
• 5 Selectable Dimming Curves
• 64 Color Macros
• Built in Microphone
• DMX-512 protocol
• 3-Pin DMX Connection
• 5 DMX Modes: 4 Channel Mode, 5 Channel Mode, 6 Channel Mode, 9 Channel Mode, & 10 Channel Mode.
• ADJ LED RC2 compatiable (Not Included)
• Power Cord Daisy Chain (See page 26)
Mega Flat Pak Plus Warranty Registration
The Mega Flat Pak Plus carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All pack­ages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
Mega Flat Pak Plus Installation
The unit’s should be mounted using a mounting clamp (not provided), axing it to the mounting bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration and slip­ping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable that can hold 12 times the weight of the unit when installing the xture. The equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
ADJ Products, LLC - www.adj.com - Mega Flat Pak Plus User Manual Page 3
Mega Flat Pak Plus Safety Precautions
Mega Flat Pak Plus Set Up
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out` doors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by t he manufacturer. See page 26 for cleaning details.
• Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (inclu­ d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the appliance. C. The appliance has been exposed to rain or water. D. The appliance does not appear to operate normally or exhibits a marked change in performance.
Power Supply: The ADJ Mega Par Prole Plus contains a automatic
voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that trav­els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter­minals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compli­ant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The Mega Par Prole Plus can be controlled via DMX-512 protocol. The Mega Par Prole Plus has 5 DMX modes, please see pages 9-10 for the dierent modes. The DMX address is set on the back panel of the Mega Par Prole Plus. Your unit and your DMX controller require a standard 3-pin XLR connec­tor for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Figure 1
ADJ Products, LLC - www.adj.com - Mega Flat Pak Plus User Manual Page 4
ADJ Products, LLC - www.adj.com - Mega Flat Pak Plus User Manual Page 5
Mega Flat Pak Plus Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
Mega Flat Pak Plus Operating Instructions
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
1 Ground
3 Hot
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
XLR Male Socket
1 Ground
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
1
3
2
DMX +
DMX -
XLR Female Socket
2 Cold
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
5-Pin XLR DMX Connectors.
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting stan­dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
ADJ Products, LLC - www.adj.com - Mega Flat Pak Plus User Manual Page 6
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
Some manufactures use 5-pin DMX-
3-Pin XLR to 5-Pin XLR Conversion
Pin 1
Pin 2
Pin 3
System Menu: The display will lock after 30 seconds, press the MODE button for 3 seconds to unlock.
LED Display On/Off:
To set the LED display to turn off after 10 seconds, press the MODE button until “don” is displayed, press the UP button to display “doff”. Now the display will disappear after 10s. Press any button to turn the display on again. Be advised though that the display will turn off automatically after 10 seconds.
To set the display press the MODE button until “dXX” is displayed. Use the UP or DOWN buttons to select either: “don” = LED display on at all times. “doFF” = LED display shuts off after 10 seconds.
LED Display Inversion:
Follow these instructions to flip the display 180° so that the display can be read upside down.
1. Plug the fixture in and press the MODE button until “dXX” is dis- played. “XX” represents either “on” or “oFF”.
2. Press the SET UP button until “Stnd” is displayed.
3. Press the UP or DOWN buttons to reverse the display 180°.
Operating Modes:
The Mega Par Profile Plus has five operating modes:
• Sound-Active mode - The unit will react to sound, chasing through the built in programs. There are 16 sound active modes.
• Color Macro Mode - There are 64 colors to choose from.
• Auto Mode - There are 3 Auto Modes to choose from.
• RGB+UV Dimmer Mode - Choose one of the four colors to remain static or adjust the intensity of each color to make your desired
color.
• DMX control mode - This function will allow you to control each individual fixtures traits with a standard DMX 512 controller.
Sound Active Mode:
In this mode the Mega Par Profile Plus will react to sound, and chase through the different colors.
1. Plug the fixture in and press the MODE button until “SoXX” is dis-
ADJ Products, LLC - www.adj.com - Mega Flat Pak Plus User Manual Page 7
Mega Flat Pak Plus Operating Instructions
Mega Flat Pak Plus Operating Instructions
played. “XX” represents the sound active mode (1-16) currently
displayed.
2. The fixture will now change via sound.
3. Press the SET UP button to adjust the sound sensitivity. “SJ-X” should be displayed. Use the UP or DOWN buttons to adjust the sensitivity. “SJ-1” is the lowest sensitivity, “SJ-8” is the highest.
Static Color Mode:
1. Plug the fixture in and press the MODE button until “CLXX” is dis-
played.
2. There are 64 colors to choose from. Select your desired color by pressing the UP and DOWN buttons. After you have selected your desired color you can activate strobing by pressing the SET UP button to enter the Flash (strobe) mode.
3. “FS.XX” will be displayed, this is Flash mode. The Flash can be adjusted between “FS.00” (flash off) to “FS.15” (fastest flash).
Auto Run Mode:
There are 3 types of Auto Run Modes to choose from; Color Color Change, and both modes running together.
The running
is adjustable in all 3 modes.
1. Plug the fixture in and press the MODE button until either “AFXX”, “AJXX”, or “A-JF” is displayed.
• AFXX = Color Fade mode, there are 16 Color Fade modes to choose from. Use the UP or DOWN buttons to scroll through the different Auto Fade modes.
• AJXX = Color Change mode, there are 16 Color Change modes to choose from. Use the UP or DOWN buttons to scroll through the different Auto Change modes.
• A-JF = Both Color Fade and Color Change modes running.
2. After you have chosen your desired running mode press the SET UP button until “SP.XX” is displayed. When this is displayed you can adjust the running speed of your desired program. Use the UP or DOWN button to adjust the speed between “SP.01” (slow­ est) and “SP.16” (fastest). Once you have set your desired running speed, press the SET UP button to return to your desired Auto Run Mode.
Fade,
speed
RGB+UV Dimmer Mode:
1. Plug the fixture in and press the MODE button until:
2. When “r.XXX” is displayed you are in Red dimming mode. Press the UP and DOWN buttons to adjust intensity.
3. When “G.XXX” is displayed you are in Green dimming mode. Press the UP and DOWN buttons to adjust intensity.
4. When “b.XXX” is displayed you are in Blue dimming mode. Press the UP and DOWN buttons to adjust intensity.
5. When “u.XXX” is displayed you are in UV dimming mode. Press the UP and DOWN buttons to adjust intensity.
6. After you have adjusted the RGB & UV colors to make your desired color you can then activate strobing by pressing the SET UP button to enter the Flash (strobe) mode.
7. “FS.XX” will be displayed, this is Flash mode. The Flash can be adjusted between “FS.00” (flash off) to “FS.15” (fastest flash).
DMX Mode:
Operating through a DMX controller gives the user the freedom to create their own programs tailored to their own individual needs. This function also allows you to use your fixtures as spot lights. The Mega
Par Profile Plus has 5 DMX modes: 4 channel mode, 5 channel mode, 6 channel mode, 9 channel mode, and a 10 channel mode. See page’s 16-23 for each mode’s DMX traits.
1. This function will allow you to control each individual fixture’s traits with a standard DMX 512 controller.
2. To run your fixture in DMX mode press the MODE button until “d.XXX” is displayed. “XXX” represents the current displayed DMX address. Use the UP or DOWN buttons to select your desired DMX address, then press the SETUP button to select your DMX Channel mode.
3. Use the UP or DOWN buttons to scroll through the DMX Channel modes. The Channel modes are listed below:
• To run the 4 Channel Mode, press the MODE button until “Ch04” is displayed. This is the 4 Channel DMX Mode.
• To run the 5 Channel Mode, press the MODE button until “Ch05” is displayed. This is the 5 Channel DMX Mode.
• To run the 6 Channel Mode, press the MODE button until “Ch06” is displayed. This is the 6 Channel DMX Mode.
ADJ Products, LLC - www.adj.com - Mega Flat Pak Plus User Manual Page 8