FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation.
This device uses and can radiate radio frequency energy and, if not installed and used in accordance with
the included instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the device off and on, the
user is encouraged to try to correct the interference by one or more of the following methods:
· Reorient or relocate the device.
· Increase the separation between the device and the receiver.
· Connect the device to an electrical outlet on a circuit different from which the radio receiver is
connected.
· Consult the dealer or an experienced radio/TV technician for help.
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying
product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection
claimed includes all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this document may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of
their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as
a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document
may be available online.
Please check www.adj.com for the latest revision/update of this manual before beginning
installation and/or programming.
Date
07/03/19
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when
they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power
when not in use. Thank you!
Document
Version
1
Software
Version >
1.1
DMX Channel
Mode
4/6/7/8/11Initial Version
Notes
Page 3
Encore Burst RGBW IPTable of Contents
Introduction
Features I Warranty Registration
Safety Guidelines
IP65 Notice
Overview
Installation
Connections
DMX Set Up
DMX Addressing
DMX Modes
System Menu
3
4
5
6
7
8
9
10
11
12
15
Multiple Unit Power Linking I Dimmer Mode Chart
Dimensional Drawing I Trouble Shooting I Cleaning
Limited Warranty (USA Only)
Specications
19
20
21
22
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 2
Page 4
Encore Burst RGBW IPIntroduction
Unpacking: Thank you for purchasing the Encore Burst RGBW IP by ADJ Products, LLC. Every Encore
Burst RGBW IP has been thoroughly tested and has been shipped in perfect operating condition. Carefully
check the shipping carton for damage that may have occurred during shipping. If the carton appears
to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary
to operate the unit has arrived intact. In the case damage has been found or parts are missing, please
contact our toll free customer support number for further instructions. Do not return this unit to your
dealer without rst contacting customer support.
Introduction: The ADJ Encore Burst RGBW IP is a DMX intelligent, high powered LED fixture. To optimize
the performance of this product, please read these operating instructions carefully to familiarize yourself
with the basic operations of this unit. These instructions contain important safety information regarding
the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit
https://forums.adj.com/ with questions, comments or suggestions.
Parts:To purchase parts online visit http://parts.americandj.com
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
Voice: 800-322-6337 | Fax: 323-582-2941 | support@adj.com
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | support@adj.eu
ADJ PRODUCTS LLC USA
6122 S. Eastern Ave. Los Angeles, CA. 90040
323-582-2650 | Fax 323-532-2941 | www.adj.com | info@adj.com
ADJ SUPPLY Europe B.V
Junostraat 2 6468 EW Kerkrade, The Netherlands
+31 (0)45 546 85 00 | Fax +31 45 546 85 99
www.adj.eu | info@americandj.eu
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself,
doing so will void your manufactures warranty. In the unlikely event your unit may require service
please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 3
Page 5
Encore Burst RGBW IPFeatures
• IP65 Outdoor Rated
• Electronic Dimming 0-100%
• DMX-512 protocol
• Multiple DMX Channel Modes
• IP65 Locking 5-Pin XLR Connector In/Out
• Frequency Adjustment
• Gamma Adjustment
• 6 Dimmer Curves With Dimmer Adjustment Speed
• Multiple Unit Power Linking (See page 19)
Included:
1 x IP65 Locking Power Cable
1 x Omega Bracket
Encore Burst RGBW IPWarranty Registration
The Encore Burst RGBW IP carries a 2 year limited warranty. Please fill out the enclosed warranty
card to validate your purchase. All returned service items whether under warranty or not, must be
freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the problem as well as the
R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit
is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A.
number by contacting our customer support team on our customer support number. All packages
returned to the service department not displaying a R.A. number on the outside of the package will be
returned to the shipper.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 4
Page 6
Encore Burst RGBW IPSafety Precautions
FOR YOUR OWN PERSONAL SAFETY, PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY
BEFORE YOU ATTEMPT TO INSTALL OR OPERATE THIS UNIT!
• THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS
YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM
MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND
GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO
ANY WARRANTY CLAIMS AND/OR REPAIRS.
• DO NOT PLUG THE FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH THE FIXTURE DURING OPERATION AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
• ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE
(AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR
ELECTRICAL SHORT CIRCUIT.
• IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION
FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE
ON IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF ENVIROMENTAL TEMPERATURE
CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS
REACHED ROOM TEMPERATURE BEFORE POWERING ON.
• NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
• Be sure that the local power outlet is compatible with the required voltage for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this
device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed
upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point
where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 20 for cleaning
details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other
appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when the appliance does not appear to operate
normally or exhibits a marked change in performance.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 5
Page 7
Encore Burst RGBW IPIP65 Notice
IP65 RATED
An IP rated lighting xture is one, which is commonly installed in outdoor environments
and has been designed with an enclosure that eectively protects the ingress (entry)
of external foreign objects such as dust and water. The International Protection (IP)
rating system is commonly expressed as "IP" (Ingress Protection) followed by two
numbers (i.e. IP65) where the numbers dene the degree of protection. The rst digit
(Foreign Bodies Protection) indicates the extent of protection against particles entering
the xture and the second digit (Water Protection) indicates the extent of protection
against water entering the xture. An IP65 rated lighting xture is one, which has been
designed and tested to protect against the ingress of dust (6) and high-pressure water
jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
NOT suitable for marine and/or coastal environment installations. Installing
this xture in a marine and/or coastal environment may cause corrosion and/
or excessive wear to the interior and/or exterior components of the xture.
Damages and/or performance issues resulting from installation in a marine
and/or coastal environment will void the manufactures warranty and will NOT be subject
to any warranty claims and/or repairs.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 6
Page 8
Encore Burst RGBW IPOverview
LCD Screen
Mode Button
Up Button
Down Button
Enter Button
IP65 5-Pin DMX OutIP65 5-Pin DMX In
IP65 Power InIP65 Power Out
Safety Cable
Rigging Point
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 7
Page 9
Encore Burst RGBW IPInstallation
Always ensure that the unit is rmly xed to avoid vibration and slipping while operating. Always
ensure that the structure to which you are attaching the unit is secure and is able to support a weight
of 10 times the unit’s weight. ALWAYS use safety cables that can hold 12 times the weight of the
unit when installing the xture. This equipment must be installed by a professional, and it must be
installed in a place where it is out of the reach of people’s grasp.
The Encore Burst RGBW IP is fully operational in three dierent mounting positions; hanging upsidedown, mounted sideways on trussing, or set on a at level surface. Be sure this xture is kept at
least 12m (40ft) away from any ammable materials (decoration etc.).
OVERHEAD RIGGING: The Encore Burst RGBW IP includes two rigging options.
1) OMEGA BRACKET - Mount the xture with an appropriately reated professional grade rigging
clamp (not included) to the included Omega Bracket using an M12 screw and nut (not included).
With the rigging clamp securely attached to the Omega Bracket, attach the Omega Bracket to the
xture by inserting both of the 1/4-turn quick-lock fasteners into the aligning holes on the xture
yoke bracket, and turning each clockwise to secure.
MAKE SURE THE OMEGA BRACKET IS SECURELY ATTACHED BEFORE RIGGING FIXTURE!
2) MOUNTING YOKE - Mount the xture with an appropriately rated professional grade rigging clamp
(not included) to the xture yoke bracket center hole using an M12 screw and nut (not included).
MAKE SURE THE CLAMP IS SECURELY ATTACHED BEFORE RIGGING FIXTURE!
SAFETY CABLE: Pull the safety-cable through the opening located on the rear of the unit and over
the trussing system or a safe xation spot. Insert the end in the carabine and tighten the safety
screw. ALWAYS use and install a safety cable as a safety measure to prevent accidental damage
and/or injury in the event the clamp fails.
CLAMP
5.35” / 136mm
4.21” / 107mm
OMEGA BRACKET
CLAMP
2.12” / 54mm
SAFETY CABLE
(Not Included)
SAFETY CABLE
RIGGING POINT
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 8
Page 10
Encore Burst RGBW IPConnections
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC
GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION
AND/OR ELECTRICAL SHORT CIRCUIT.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE,
ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED. ONLY IP65 RATED POWER
AND DATE CABLES MUST BE USED.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 9
Page 11
Encore Burst RGBW IPDMX Set Up
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the
DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a
DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be
linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use
the shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The Encore Burst RGBW IP can be controlled
via DMX-512 protocol. The Encore Burst RGBW IP has multiple DMX channel modes. Your unit and
your DMX controller requires a 5-pin XLR connector for data input and data output. We recommend AccuCable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded
cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with
a male and female XLR connector on either end of the cable. Also remember that DMX cable must be
daisy chained and cannot be split.
Special Note: Line Termination.
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected
between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female
XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ
part number Z-DMX/T) will decrease the possibilities of erratic behavior.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE,
ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED AND ONLY IP65 RATED POWER
AND DATE CABLES MUST BE USED.
When longer runs of cable are used, you may need to use a terminator
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 10
Page 12
Encore Burst RGBW IPDMX Addressing
DMX ADDRESSING
All xtures should be given a DMX starting address when using a DMX controller, so the correct xture
responds to the correct control signal. This digital starting address is the channel number from which
the xture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment
of this starting DMX address is achieved by setting the correct DMX address on the digital control
display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set dierent addresses
for each individual xture. Setting all xtures to the same DMX address will cause all xtures to react
in the same way, in other words, changing the settings of one channel will aect all the xtures
simultaneously.
If you set each xture to a dierent DMX address, each unit will start to “listen” to the channel number
you have set, based on the quantity of DMX channels of each xture. That means changing the settings
of one channel will only aect the selected xture.
In the case of the Encore Burst RGBW IP, when in 4 channel mode you should set the starting DMX address
of the rst unit to 1, the second unit to 5 (4 + 1), the third unit to 9 (5 + 4), and so on. (See chart below
for more details.)
Channel Mode
4 Channels15913
6 Channels
7 Channels
8 Channels
11 Channels
Unit 1
Address
171319
181522
191725
1122334
Unit 2
Address
Unit 3
Address
Unit 4
Address
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 11
No Effect
Moroccan Pink
Pink
Special Rose Pink
Fillies Pink
Fuchsia Pink
Surprise Pink
Congo Blue
Tokyo Blue
Deep Blue
Just Blue
Medium Blue
Double CT Blue
State Blue
Full CT Blue
Half CT Blue
Steel Blue
Lighter Blue
Light Blue
Medium Blue Green
Dark Green
Primary Green
Moss Green
Fern Green
JAS Green
Lime Green
Spring Yellow
Deep Amber
Chrome Orange
Orange
Gold Amber
Millennium Gold
Deep Gold Amber
Flame Red
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 12
Default to Unit Setting
900HZ
1000HZ
1100HZ
1200HZ
1300HZ
1400HZ
1500HZ
2500HZ
4000HZ
5000HZ
6000HZ
Default to Unit Setting
GAMMA
Default to Unit Setting
1.0
2.0
2.2
2.4
2.6
2.8
No Function
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 14
Page 16
Encore Burst RGBW IPSystem Menu
SYSTEM MENU
The xture includes an easy to navigate system menu control panel display where all necessary
settings and adjustments are made. (See image below) During normal operation, pressing the MENU
button once will access the xture’s main menu. Once in the main menu, you can navigate through
the dierent menu’s with the UP, DOWN, and MENU buttons. When you reach a eld that requires
adjusting, press the ENTER button to access that eld and use the UP and DOWN buttons to adjust
the eld. Pressing the ENTER button once more to conrm your setting. You may exit the menu’s
at any time without making any adjustments by pressing the MENU button.If there are no changes/
adjustments made within 10 seconds, the unit will revert back to the setting made under “No DMX State”.
MENU
ENTER
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 15
Page 17
Encore Burst RGBW IPSystem Menu
MENUOPTIONSDESCRIPTIONSUBMENU
DMX Address001-XXX
DMX CH Mode
No DMX StateHold Last / Blackout / Manual
Dim Modes
LED Refresh Rate
Gamma1.0 / 2.0 / 2.2 / 2.4 / 2.6 / 2.8
Display
ServicePass Code = 50
Manual Control
Information
Backlight
Display Lock
Fixture Life Time
Total LED Time
Fixture Temps
DMX Values
(See Note 3)
Software Version
(3)
4Ch / 6Ch / 7Ch / 8Ch / 11Ch
Standard / Stage / TV / Architectural / Theatre /
Stage2
Red / Green / Blue / White / Color Macros / Strobe /
Dimmer / Dimmer Fine / Dim Modes /
Refresh Rates / Gamma
X.X
DMX Addressing
DMX Channel Mode
Selection
DMX Lost Status
Dimming Curve Modes
Dimming Speed
LED Refresh Setting
Gamma Brightness
Backlight Control
Display Control Lock
Calibration
Factory Settings
Manual Control
Total Running Time
(Not Resettable)
Total Running Time
(Resettable)
Reset Total Running Time
Total LED On Running
Time (Not Resettable)
LED On Running Time
(Resettable)
Reset LED Running Time
Current Temperature
Maximum Temperature
Reached (Resettable)
(See Note 1)
Maximum Temperature
Reached (Not Resettable)
(See Note 2)
Reset Temperature
Current DMX Values
Current Software Version
(1)
(2)
Notes:
(1) Current Maximum Temperature - Maximum fixture temp. that has been recorded, before reset and after reset.
(2) Maximum Temperature - Overall maximum fixture temp. that has been recorded. (Not Resettable)
(3) DMX value options depend on the DMX Channel mode the fixture is set to.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 16
Page 18
Encore Burst RGBW IPSystem Menu
SET ADDRESS - In this menu you can nd and set your desired DMX address.
DMX CHANNEL MODE - In this menu you can nd and set your desired DMX channel mode.
NO DMX STATUS - This menu setting is used as a precaution mode in case the DMX signal is lost
or interrupted. The operating mode chosen in this menu is the running mode the xture will go into
when the DMX signal is lost. Listed below are the 3 modes.
• Hold Last - This setting will have the xture stay in the last DMX setup.
• Blackout - This setting will have the xture automatically go into stand by mode.
• Manual - This setting will go into the current manual control set up. See MANUAL CONTROL.
DIM MODES - In this menu you are able to select your desired dimmer mode and adjust the dimming
speed time.
LED REFRESH RATE - In this menu you are able to select your desired LED refresh rate.
GAMMA - In this menu you are able to select your desired gamma setting.
DISPLAY - In this menu you you are able to activate/deactivate the display blackout and activate/deactivate
the display lock.
SERVICE - In this menu you are able to access and adjust/change: the calibration (eect adjust) and
restore the factory settings.
MANUAL CONTROL - This menu is for manual testing and manual control. The dimmer and strobe
can be tested/adjusted. The xture must be set to “Manual” under “No DMX State”.
FIXTURE LIFE TIME
• Power On Time -The TOTAL power ON running time of the unit is displayed. This time CANNOTbe reset.
• P-On Time-R - The CURRENT power ON running time of the unit is displayed. This running time may not be the same as the TOTAL power ON running time displayed under “Power On Time”. This time CAN be reset. NOTE: The displayed time represents the current power ON time
since the last reset.
• P-On Time-Reset - Reset the CURRENT power ON running time that is displayed under “P-On Time-R”.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 17
Page 19
Encore Burst RGBW IPSystem Menu
TOTAL LED TIME
• LED On Time - The TOTAL LED ON time is displayed. This total LED ON time CANNOT be reset. NOTE: The displayed time represents the TOTAL LED ON time.
• LED On Time-R - The CURRENT LED ON running time is displayed. This running time may not be the same as the total LED ON time displayed under “LED On Time”. This total LED ON time
CAN be reset. NOTE: The displayed time represents the current LED ON time since the last
reset.
• LED On Time Reset - With this function you can reset the CURRENT LED ON time that is displayed
under “LED On Time-R”.
FIXTURE TEMPS
• Current - The current unit temperature is displayed.
• Max Resettable - Maximum temperature that has been recorded, before reset and after reset.
This temperature may not be the same as the temperature displayed under “CURRENT” or “MAX NOT
RESETTABLE”. This temperature CAN be reset.
NOTE: The displayed temperature represents the highest temperature the xture has reached
since the last reset.
• Max Not Resettable - Overall maximum temperature that has been recorded. This temperature CANNOT be reset, and could continue rise.
• Rst Temp History - Reset the “Max Resettable” temperature.
DMX VALUES - Displays the DMX values of any DMX channel that is currently in use. NOTE: DMX
value options depend on the current DMX channel mode setting.
SOFTWARE VERSION - The current software version is displayed.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 18
Page 20
Encore Burst RGBW IPMultiple Unit Power Linking
DIMMER
100%
50%
10%
0%
Time (ms)
255255
00
Stage780110015401660
TV1180152018601940
Architectural1380173020402120
0 sec Fade Time
1 sec Fade Time
With this feature you can connect the xtures to one another using the power cable input and
output sockets.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON
THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
Encore Burst RGBW IPDimmer Mode Chart
Rise TimeDown Time
0 Sec
Dimming Curve
Ramp Effect
Rise Time (ms)Down Time (ms)Rise Time (ms)Down Time (ms)
Standard (default)0000
Theatre1580194022302280
Stage 2
0110001660
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 19
Page 21
Encore Burst RGBW IPDimensional Drawings
6” / 153mm
9.8” / 249mm
12.12” / 308mm
9.21” / 234mm
Encore Burst RGBW IPTrouble Shooting
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on
some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right
connectors; it does matter which way the inputs and outputs are connected.
Encore Burst RGBW IPCleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog
residue, dust, dew).
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 20
Page 22
Encore Burst RGBW IPLimited Warranty (USA Only)
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products
to be free of manufacturing defects in material and workmanship for a prescribed period from
the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the
product is purchased within the United States of America, including possessions and
territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#)
before sending back the product–please contact ADJ Products, LLC Service Department
at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All
shipping charges must be pre-paid. If the requested repairs or service (including
parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return
shipping charges only to a designated point within the United States. If the entire instrument is
sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If
any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for
loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any
manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the
product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior
written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because
not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check
up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense
with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this
warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole
discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August
15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products
without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with
products described above. Except to the extent prohibited by applicable law, all implied warranties made
by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness,
are limited in duration to the warranty period set forth above. And no warranties, whether expressed or
implied, including warranties of merchantability or fitness, shall apply to this product after said period
has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is
expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or
damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore
published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
• Non L.E.D. Lighting Products = 1-year (365 days) Limited Warranty (Such as: Special Effect
Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par
Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
• Laser Products = 1 Year (365 Days) Limited Warranty (excluding laser diodes which have a 6 month
limited warranty)
• L.E.D. Products = 2-year (730 days) Limited Warranty (excluding batteries which have a 180 day limited
warranty). Note: 2 Year Warranty only applies to purchases within the United States.
• StarTec Series = 1 Year Limited Warranty (excluding batteries which have a 180 day limited warranty).