ADJ Encore Burst RGBW IP User guide

Page 1
ENCORE BURST RGBW IP
User Instructions
Page 2
©2019 ADJ Products, LLC all rights reserved. Information, specications, diagrams, images, and
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:
· Reorient or relocate the device.
· Increase the separation between the device and the receiver.
· Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and opera­tion of this product.
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document may be available online. Please check www.adj.com for the latest revision/update of this manual before beginning installation and/or programming.
Date
07/03/19
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when
they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Document Version
1
Software Version >
1.1
DMX Channel Mode
4/6/7/8/11 Initial Version
Notes
Page 3
Encore Burst RGBW IP Table of Contents
Introduction Features I Warranty Registration Safety Guidelines IP65 Notice Overview Installation Connections DMX Set Up DMX Addressing DMX Modes System Menu
3 4 5 6 7 8
9 10 11 12 15
Multiple Unit Power Linking I Dimmer Mode Chart Dimensional Drawing I Trouble Shooting I Cleaning Limited Warranty (USA Only)
Specications
19 20 21 22
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 2
Page 4
Encore Burst RGBW IP Introduction
Unpacking: Thank you for purchasing the Encore Burst RGBW IP by ADJ Products, LLC. Every Encore Burst RGBW IP has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact our toll free customer support number for further instructions. Do not return this unit to your
dealer without rst contacting customer support.
Introduction: The ADJ Encore Burst RGBW IP is a DMX intelligent, high powered LED fixture. To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit
https://forums.adj.com/ with questions, comments or suggestions.
Parts: To purchase parts online visit http://parts.americandj.com
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST Voice: 800-322-6337 | Fax: 323-582-2941 | support@adj.com
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | support@adj.eu
ADJ PRODUCTS LLC USA
6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-2650 | Fax 323-532-2941 | www.adj.com | info@adj.com
ADJ SUPPLY Europe B.V
Junostraat 2 6468 EW Kerkrade, The Netherlands
+31 (0)45 546 85 00 | Fax +31 45 546 85 99
www.adj.eu | info@americandj.eu
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 3
Page 5
Encore Burst RGBW IP Features
• IP65 Outdoor Rated
• Electronic Dimming 0-100%
• DMX-512 protocol
• Multiple DMX Channel Modes
• IP65 Locking 5-Pin XLR Connector In/Out
• Frequency Adjustment
• Gamma Adjustment
• 6 Dimmer Curves With Dimmer Adjustment Speed
• Multiple Unit Power Linking (See page 19)
Included:
1 x IP65 Locking Power Cable 1 x Omega Bracket
Encore Burst RGBW IP Warranty Registration
The Encore Burst RGBW IP carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All packages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 4
Page 6
Encore Burst RGBW IP Safety Precautions
FOR YOUR OWN PERSONAL SAFETY, PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY
BEFORE YOU ATTEMPT TO INSTALL OR OPERATE THIS UNIT!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG THE FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING FIXTURE! NEVER TOUCH THE FIXTURE DURING OPERATION AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF ENVIROMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
• Be sure that the local power outlet is compatible with the required voltage for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this
device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed
upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point
where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 20 for cleaning
details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other
appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when the appliance does not appear to operate normally or exhibits a marked change in performance.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 5
Page 7
Encore Burst RGBW IP IP65 Notice
IP65 RATED
An IP rated lighting xture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that eectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers dene the degree of protection. The rst digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the xture and the second digit (Water Protection) indicates the extent of protection against water entering the xture. An IP65 rated lighting xture is one, which has been
designed and tested to protect against the ingress of dust (6) and high-pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
NOT suitable for marine and/or coastal environment installations. Installing
this xture in a marine and/or coastal environment may cause corrosion and/ or excessive wear to the interior and/or exterior components of the xture.
Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and/or repairs.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 6
Page 8
Encore Burst RGBW IP Overview
LCD Screen Mode Button Up Button Down Button Enter Button
IP65 5-Pin DMX OutIP65 5-Pin DMX In
IP65 Power In IP65 Power Out
Safety Cable Rigging Point
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 7
Page 9
Encore Burst RGBW IP Installation
Always ensure that the unit is rmly xed to avoid vibration and slipping while operating. Always
ensure that the structure to which you are attaching the unit is secure and is able to support a weight
of 10 times the unit’s weight. ALWAYS use safety cables that can hold 12 times the weight of the unit when installing the xture. This equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
The Encore Burst RGBW IP is fully operational in three dierent mounting positions; hanging upside­down, mounted sideways on trussing, or set on a at level surface. Be sure this xture is kept at least 12m (40ft) away from any ammable materials (decoration etc.).
OVERHEAD RIGGING: The Encore Burst RGBW IP includes two rigging options.
1) OMEGA BRACKET - Mount the xture with an appropriately reated professional grade rigging
clamp (not included) to the included Omega Bracket using an M12 screw and nut (not included). With the rigging clamp securely attached to the Omega Bracket, attach the Omega Bracket to the
xture by inserting both of the 1/4-turn quick-lock fasteners into the aligning holes on the xture
yoke bracket, and turning each clockwise to secure.
MAKE SURE THE OMEGA BRACKET IS SECURELY ATTACHED BEFORE RIGGING FIXTURE!
2) MOUNTING YOKE - Mount the xture with an appropriately rated professional grade rigging clamp
(not included) to the xture yoke bracket center hole using an M12 screw and nut (not included).
MAKE SURE THE CLAMP IS SECURELY ATTACHED BEFORE RIGGING FIXTURE!
SAFETY CABLE: Pull the safety-cable through the opening located on the rear of the unit and over
the trussing system or a safe xation spot. Insert the end in the carabine and tighten the safety
screw. ALWAYS use and install a safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails.
CLAMP
5.35” / 136mm
4.21” / 107mm
OMEGA BRACKET
CLAMP
2.12” / 54mm
SAFETY CABLE (Not Included)
SAFETY CABLE RIGGING POINT
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 8
Page 10
Encore Burst RGBW IP Connections
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED. ONLY IP65 RATED POWER AND DATE CABLES MUST BE USED.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 9
Page 11
Encore Burst RGBW IP DMX Set Up
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The Encore Burst RGBW IP can be controlled via DMX-512 protocol. The Encore Burst RGBW IP has multiple DMX channel modes. Your unit and your DMX controller requires a 5-pin XLR connector for data input and data output. We recommend Accu­Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Special Note: Line Termination.
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED AND ONLY IP65 RATED POWER AND DATE CABLES MUST BE USED.
When longer runs of cable are used, you may need to use a terminator
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 10
Page 12
Encore Burst RGBW IP DMX Addressing
DMX ADDRESSING
All xtures should be given a DMX starting address when using a DMX controller, so the correct xture
responds to the correct control signal. This digital starting address is the channel number from which
the xture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment
of this starting DMX address is achieved by setting the correct DMX address on the digital control
display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set dierent addresses for each individual xture. Setting all xtures to the same DMX address will cause all xtures to react in the same way, in other words, changing the settings of one channel will aect all the xtures
simultaneously.
If you set each xture to a dierent DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of DMX channels of each xture. That means changing the settings of one channel will only aect the selected xture.
In the case of the Encore Burst RGBW IP, when in 4 channel mode you should set the starting DMX address
of the rst unit to 1, the second unit to 5 (4 + 1), the third unit to 9 (5 + 4), and so on. (See chart below
for more details.)
Channel Mode
4 Channels 1 5 9 13
6 Channels
7 Channels
8 Channels
11 Channels
Unit 1
Address
1 7 13 19
1 8 15 22
1 9 17 25
1 12 23 34
Unit 2
Address
Unit 3
Address
Unit 4
Address
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 11
Page 13
Encore Burst RGBW IP DMX Modes
4 CH
6 CH 7 CH 8 CH
1
11
22 2 22
33 3 33
44 4 44
11 CH
11
5
VALUES
000-255
000-255
000-255
000-255
000-007 008-015 016-022 023-030 031-037 038-045 046-052 053-060 061-067 068-075 076-082 083-090 091-097 098-105 106-112 113-120 121-127 128-135 136-142 143-150 151-157 158-165 166-172 173-180 181-187 188-195 196-202 203-210 211-217 218-225 226-232 233-240 241-247 248-255
FUNCTIONS
RED
0%-100%
GREEN
0%-100%
BLUE
0%-100%
WHITE
0%-100%
COLOR MACROS
No Effect Moroccan Pink Pink Special Rose Pink Fillies Pink Fuchsia Pink Surprise Pink Congo Blue Tokyo Blue Deep Blue Just Blue Medium Blue Double CT Blue State Blue Full CT Blue Half CT Blue Steel Blue Lighter Blue Light Blue Medium Blue Green Dark Green Primary Green Moss Green Fern Green JAS Green Lime Green Spring Yellow Deep Amber Chrome Orange Orange Gold Amber Millennium Gold Deep Gold Amber Flame Red
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 12
Page 14
Encore Burst RGBW IP DMX Modes
4 CH
6 CH 7 CH 8 CH
5 5 6
5
6
76 87
11 CH
76
98
VALUES
000-031 032-063 064-095 096-127 128-159 160-191 192-223 224-255
000-255
000-255
000-020 021-040 041-060 061-080 081-100 101-120
121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140
141-255
FUNCTIONS
SHUTTER & STROBING
LED Off LED On Strobing Slow - Fast LED On Pulse Strobing LED On Random Strobing Slow - Fast LED On
MASTER DIMMER
0%-100%
DIMMER FINE
0%-100%
DIMMER MODES
Standard Stage TV Architectural Theatre Stage 2
DIMMER DELAY TIME
0.1Sec.
0.2Sec.
0.3Sec.
0.4Sec.
0.5Sec.
0.6Sec.
0.7Sec.
0.8Sec.
0.9Sec.
1.0Sec.
1.5Sec.
2.0Sec.
3.0Sec.
4.0Sec.
5.0Sec.
6.0Sec.
7.0Sec.
8.0Sec.
9.0Sec. 10Sec. Default to Unit Setting
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 13
Page 15
Encore Burst RGBW IP DMX Modes
4 CH 11 CH
6 CH 7 CH 8 CH
10
11
VALUES
000-015 016-030 031-045 046-060 061-075 076-090 091-105 106-120 121-135 136-150 151-165 166-180 181-255
000-020 021-040 041-060 061-080 081-100 101-120 121-130 131-255
FUNCTIONS
REFRESH RATE
Default to Unit Setting 900HZ 1000HZ 1100HZ 1200HZ 1300HZ 1400HZ 1500HZ 2500HZ 4000HZ 5000HZ 6000HZ Default to Unit Setting
GAMMA
Default to Unit Setting
1.0
2.0
2.2
2.4
2.6
2.8 No Function
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 14
Page 16
Encore Burst RGBW IP System Menu
SYSTEM MENU
The xture includes an easy to navigate system menu control panel display where all necessary
settings and adjustments are made. (See image below) During normal operation, pressing the MENU
button once will access the xture’s main menu. Once in the main menu, you can navigate through the dierent menu’s with the UP, DOWN, and MENU buttons. When you reach a eld that requires adjusting, press the ENTER button to access that eld and use the UP and DOWN buttons to adjust the eld. Pressing the ENTER button once more to conrm your setting. You may exit the menu’s
at any time without making any adjustments by pressing the MENU button.If there are no changes/ adjustments made within 10 seconds, the unit will revert back to the setting made under “No DMX State”.
MENU
ENTER
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 15
Page 17
Encore Burst RGBW IP System Menu
MENU OPTIONS DESCRIPTIONSUBMENU
DMX Address 001-XXX
DMX CH Mode
No DMX State Hold Last / Blackout / Manual
Dim Modes
LED Refresh Rate
Gamma 1.0 / 2.0 / 2.2 / 2.4 / 2.6 / 2.8
Display
Service Pass Code = 50
Manual Control
Information
Backlight
Display Lock
Fixture Life Time
Total LED Time
Fixture Temps
DMX Values
(See Note 3)
Software Version
(3)
4Ch / 6Ch / 7Ch / 8Ch / 11Ch
Standard / Stage / TV / Architectural / Theatre / Stage2
Dim Speed: 0.1-0.9s ~ 1-10S
900Hz / 1000Hz / 1100Hz / 1200Hz / 1300Hz / 1400Hz / 1500Hz / 2500Hz / 4000Hz / 5000Hz / 6000Hz
ON / OFF
ON / OFF
Effect Adjust - Pass Code = 50 - Red 000-255 / Green 000 - 255 / Blue 000-255 / White 000-255
Factory Restore - Pass Code = 11
Red: 000 - 255 / Green: 000 - 255 / Blue: 000 - 255 / White: 000 - 255 / Strobe: 000 - 255 / Dimmer: 000 - 255
Power On Time - XXXXXX Hours
P-On Time-R - XXXXXX Hours
P-On Time Reset - Pass Code = 50
LED On Time - XXXXXX Hours
LED On Time-R - XXXXXX Hours
LED Time Reset - Pass Code = 50
Current - XXX˚
Max Resettable - XXX˚
Max Not Resettable - XXX˚
Rst Temp Histor - Pass Code = 50
Red / Green / Blue / White / Color Macros / Strobe / Dimmer / Dimmer Fine / Dim Modes / Refresh Rates / Gamma
X.X
DMX Addressing
DMX Channel Mode Selection
DMX Lost Status
Dimming Curve Modes
Dimming Speed
LED Refresh Setting
Gamma Brightness
Backlight Control
Display Control Lock
Calibration
Factory Settings
Manual Control
Total Running Time (Not Resettable)
Total Running Time (Resettable)
Reset Total Running Time
Total LED On Running Time (Not Resettable)
LED On Running Time (Resettable)
Reset LED Running Time
Current Temperature
Maximum Temperature Reached (Resettable)
(See Note 1)
Maximum Temperature Reached (Not Resettable)
(See Note 2)
Reset Temperature
Current DMX Values
Current Software Version
(1)
(2)
Notes: (1) Current Maximum Temperature - Maximum fixture temp. that has been recorded, before reset and after reset. (2) Maximum Temperature - Overall maximum fixture temp. that has been recorded. (Not Resettable) (3) DMX value options depend on the DMX Channel mode the fixture is set to.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 16
Page 18
Encore Burst RGBW IP System Menu
SET ADDRESS - In this menu you can nd and set your desired DMX address.
DMX CHANNEL MODE - In this menu you can nd and set your desired DMX channel mode.
NO DMX STATUS - This menu setting is used as a precaution mode in case the DMX signal is lost
or interrupted. The operating mode chosen in this menu is the running mode the xture will go into
when the DMX signal is lost. Listed below are the 3 modes.
Hold Last - This setting will have the xture stay in the last DMX setup.
Blackout - This setting will have the xture automatically go into stand by mode.
Manual - This setting will go into the current manual control set up. See MANUAL CONTROL.
DIM MODES - In this menu you are able to select your desired dimmer mode and adjust the dimming speed time.
LED REFRESH RATE - In this menu you are able to select your desired LED refresh rate.
GAMMA - In this menu you are able to select your desired gamma setting.
DISPLAY - In this menu you you are able to activate/deactivate the display blackout and activate/deactivate
the display lock.
SERVICE - In this menu you are able to access and adjust/change: the calibration (eect adjust) and
restore the factory settings.
MANUAL CONTROL - This menu is for manual testing and manual control. The dimmer and strobe
can be tested/adjusted. The xture must be set to “Manual” under “No DMX State”.
FIXTURE LIFE TIME
Power On Time -The TOTAL power ON running time of the unit is displayed. This time CANNOT be reset.
P-On Time-R - The CURRENT power ON running time of the unit is displayed. This running time may not be the same as the TOTAL power ON running time displayed under “Power On Time”. This time CAN be reset. NOTE: The displayed time represents the current power ON time
since the last reset.
P-On Time-Reset - Reset the CURRENT power ON running time that is displayed under “P-On Time-R”.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 17
Page 19
Encore Burst RGBW IP System Menu
TOTAL LED TIME
LED On Time - The TOTAL LED ON time is displayed. This total LED ON time CANNOT be reset. NOTE: The displayed time represents the TOTAL LED ON time.
LED On Time-R - The CURRENT LED ON running time is displayed. This running time may not be the same as the total LED ON time displayed under “LED On Time”. This total LED ON time
CAN be reset. NOTE: The displayed time represents the current LED ON time since the last reset.
LED On Time Reset - With this function you can reset the CURRENT LED ON time that is displayed under “LED On Time-R”.
FIXTURE TEMPS
Current - The current unit temperature is displayed.
Max Resettable - Maximum temperature that has been recorded, before reset and after reset.
This temperature may not be the same as the temperature displayed under “CURRENT” or “MAX NOT RESETTABLE”. This temperature CAN be reset.
NOTE: The displayed temperature represents the highest temperature the xture has reached since the last reset.
Max Not Resettable - Overall maximum temperature that has been recorded. This temperature CANNOT be reset, and could continue rise.
Rst Temp History - Reset the “Max Resettable” temperature.
DMX VALUES - Displays the DMX values of any DMX channel that is currently in use. NOTE: DMX
value options depend on the current DMX channel mode setting.
SOFTWARE VERSION - The current software version is displayed.
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 18
Page 20
Encore Burst RGBW IP Multiple Unit Power Linking
DIMMER
100%
50%
10%
0%
Time (ms)
255 255
0 0
Stage 780 1100 1540 1660
TV 1180 1520 1860 1940
Architectural 1380 1730 2040 2120
0 sec Fade Time
1 sec Fade Time
With this feature you can connect the xtures to one another using the power cable input and
output sockets. NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
Encore Burst RGBW IP Dimmer Mode Chart
Rise Time Down Time
0 Sec
Dimming Curve
Ramp Effect
Rise Time (ms) Down Time (ms) Rise Time (ms) Down Time (ms)
Standard (default) 0 0 0 0
Theatre 1580 1940 2230 2280
Stage 2
0 1100 0 1660
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 19
Page 21
Encore Burst RGBW IP Dimensional Drawings
6” / 153mm
9.8” / 249mm
12.12” / 308mm
9.21” / 234mm
Encore Burst RGBW IP Trouble Shooting
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right connectors; it does matter which way the inputs and outputs are connected.
Encore Burst RGBW IP Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be car­ried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days. Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog
residue, dust, dew).
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 20
Page 22
Encore Burst RGBW IP Limited Warranty (USA Only)
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#) before sending back the product–please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
• Non L.E.D. Lighting Products = 1-year (365 days) Limited Warranty (Such as: Special Effect
Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
• Laser Products = 1 Year (365 Days) Limited Warranty (excluding laser diodes which have a 6 month
limited warranty)
• L.E.D. Products = 2-year (730 days) Limited Warranty (excluding batteries which have a 180 day limited warranty). Note: 2 Year Warranty only applies to purchases within the United States.
StarTec Series = 1 Year Limited Warranty (excluding batteries which have a 180 day limited warranty).
• ADJ DMX Controllers = 2 Year (730 Days) Limited Warranty
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 21
Page 23
Encore Burst RGBW IP Specifications
Model:
Voltage: 100V ~ 240V/50~60Hz LEDs: 1 x 150W RGBW 4-in-1 C.O.B. LED
IP Rating: 65 Working Position: Any safe working position Power Draw: 121W Weight: 8 lbs./ 3.6 Kgs.
Dimensions: 9.21” (L) x 9.8” (W) x 12.12” (H) 234 x 249 x 308mm
DMX Channels: 5 DMX Modes: 4 / 6 / 7 / 8 / 11 Warranty: 2 Year (730 days)
Please Note: Specications and improvements in the design of this
unit and this manual are subject to change without notice.
Encore Burst RGBW IP
ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 22
Loading...