specications, diagrams, images, and instructions herein are
subject to change without notice. ADJ Products, LLC logo and
identifying product names and numbers herein are trademarks
of ADJ Products, LLC. Copyright protection claimed includes all
forms and matters of copyrightable materials and information
now allowed by statutory or judicial law or hereinafter granted.
Product names used in this document may be trademarks or
registered trademarks of their respective companies and are
hereby acknowledged. All non-ADJ Products, LLC brands and
product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property, equipment, building, and
electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any
information contained within this document, and/or as a result
of the improper, unsafe, unsucient and negligent assembly,
installation, rigging, and operation of this product.
Rev. 6/15
User Instructions
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment.
Please turn o all electrical products when they are not in use. To
avoid power consumption in idle mode, disconnect all electrical
equipment from power when not in use. Thank you!
5P Hex/5P Hex Pearl Introduction
5P Hex/5P Hex Pearl Features
Unpacking:Thank you for purchasing the 5P Hex/5P Hex Pearl by ADJ
Products, LLC. Every 5P Hex/5P Hex Pearl has been thoroughly tested
and has been shipped in perfect operating condition. Carefully check
the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate
the unit has arrived intact. In the case damage has been found or parts
are missing, please contact our toll free customer support number for
further instructions. Do not return this unit to your dealer without rst
contacting customer support.
Introduction:The 5P Hex/5P Hex Pearl is a DMX intelligent, LED par
fixture. This xture can be used in a stand alone mode or connected
in a Master/Slave conguration. This par has five operating modes:
Sound Active mode, Program mode, RGBWA + UV dimmer mode,
Static Color mode, and DMX control mode. The 5P has 4 DMX channel
modes; 6, 7, 8, & 12.
Customer Support: ADJ Products, LLC provides a customer support
line, to provide set up help and to answer any question should you
encounter problems during your set up or initial operation. You may
also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m.
Pacic Standard Time.
Voice: (800) 322-6337
Fax: (323) 582-2941
E-mail: support@americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact
ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
The 5P Hex/5P Hex Pearl carries a 2 year limited warranty. Please fill
out the enclosed warranty card to validate your purchase. All returned
service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number
must be clearly written on the outside of the return package. A brief
description of the problem as well as the R.A. number must also be
written down on a piece of paper included in the shipping carton. If
the unit is under warranty, you must provide a copy of your proof of
purchase invoice. You may obtain a R.A. number by contacting our
customer support team on our customer support number. All packages returned to the service department not displaying a R.A. number
on the outside of the package will be returned to the shipper.
5P Hex/5P Hex Pearl Installation
The unit should be mounted using a mounting clamp (not provided),
axing it to the mounting bracket that is provided with the unit.
Always ensure that the unit is rmly xed to avoid vibration and slipping while operating. Always ensure that the structure to which you
are attaching the unit is secure and is able to support a weight of 10
times the unit’s weight. Also, always use a safety cable that can hold
12 times the weight of the unit when installing the xture.
The equipment must be installed by a professional, and it must be
installed in a place where it is out of the reach of people’s grasp.
ADJ Products, LLC - www.adj.com - 5P Hex/5P Hex Pearl User Manual Page 2
ADJ Products, LLC - www.adj.com - 5P Hex/5P Hex Pearl User Manual Page 3
5P Hex/5P Hex Pearl Safety Precautions
5P Hex/5P Hex Pearl Set Up
• To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been
frayed or broken. Do not attempt to remove or break o the ground
prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user
serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out`
doors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by
t he manufacturer. See page 19 for cleaning details.
• Heat -The appliance should be situated away from heat sources
such as radiators, heat registers, stoves, or other appliances (inclu d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
C. The appliance has been exposed to rain or water.
D. The appliance does not appear to operate normally or exhibits a
marked change in performance.
ADJ Products, LLC - www.adj.com - 5P Hex/5P Hex Pearl User Manual Page 4
Power Supply: The ADJ 5P Hex/5P Hex Pearl contains a automatic
voltage switch, which will auto sense the voltage when it is plugged
into the power source. With this switch there is no need to worry about
the correct power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures
and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA
“OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of
dierent manufactures to be linked together and operate from a single
controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The 5P Hex/5P Hex Pearl can be controlled via DMX protocol. The 5P
Hex/5P Hex Pearl has 4 DMX channel modes, please see pages 7-8 for
the dierent modes. Your unit and your DMX controller require a standard 3-pin XLR connector for data input and data
output (Figure 1). We recommend Accu-Cable
DMX cables. If you are making your own cables,
be sure to use standard 110-120 Ohm shielded
cable (This cable may be purchased at almost all
pro lighting stores). Your cables should be made
with a male and female XLR connector on either
end of the cable. Also remember that DMX cable
must be daisy chained and cannot be split.
Figure 1
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
ADJ Products, LLC - www.adj.com - 5P Hex/5P Hex Pearl User Manual Page 5
5P Hex/5P Hex Pearl Set Up
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signalerrors andavoids signal transmission problemsand interference. It is always advisableto connect a DMX terminal, (Resistance120 Ohm 1/4 W) between PIN 2 (DMX-)and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
5P Hex/5P Hex Pearl Operating Instructions
nect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
COMMON
DMX512 OUT
3-PIN XLR
1
3
2
DMX +
DMX -
3
1
2
DMX512 IN
3-PIN XLR
Figure 2
XLR Male Socket
1 Ground
2 Cold
3 Hot
XLR Female Socket
2 Cold
1 Ground
3 Hot
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
Figure 3
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ Products, LLC part number Z-DMX/T) will decrease the possibilities of erratic behavior.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
5-Pin XLR DMX Connectors.
and PIN 3 (DMX +) of the last fixture.
Some manufactures use 5-pin DMX-
Figure 4
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX
xtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a cable adaptor must be used,
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
ADJ Products, LLC - www.adj.com - 5P Hex/5P Hex Pearl User Manual Page 6
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
Control Panel Lock:
The control panel will lock itself after 30 seconds if nothing is
pressed. To unlock the control panel, press the MODE button
for 3 seconds.
Operating Modes:
The 5P Hex/5P Hex Pearl has five operating modes:
• DMX control mode - This function will allow you to control each
individual fixtures traits with a standard DMX 512 controller.
• RGBWA + UV Mode - Choose one of the six colors to remain static
or adjust the intensity of each color to make your own color.
• Sound-Active mode - The unit will react to sound, chasing through
the built in programs. The sound sensitivity is adjustable
• Program Mode - There are 7 built-in programs to choose from.
Color change and color fade speeds are adjustable.
• Static Color Mode - There are 63 colors to choose from.
DMX Mode:
Operating through a DMX controller gives the user the freedom to
create their own programs tailored to their own individual needs. The
5P Hex/5P Hex Pearl has 4 DMX modes: 6 Channel mode, 7 Channel
mode, 8 Channel mode, and a 12 Channel mode. See pages 13-16
for each modes’ DMX traits.
1. This function will allow you to control each individual fixture’s
traits with a standard DMX 512 controller.
2. To run your fixture in DMX mode press the MODE button until
“AXXX” is displayed. “XXX” represents the current displayed ad dress. Use the UP or DOWN buttons to select your desired DMX
address, then press the ENTER button to select your DMX
Channel mode.
3. Use the UP or DOWN buttons to scroll through the DMX Channel
modes. The Channel modes are listed below:
• To run the 6 Channel Mode, press the MODE button until “Ch06”
is displayed. This is the 6 Channel DMX Mode.
• To run the 7 Channel Mode, press the MODE button until “Ch07”
is displayed. This is the 7 Channel DMX Mode.
• To run the 8 Channel Mode, press the MODE button until “Ch08”
is displayed. This is the 8 Channel DMX Mode.
ADJ Products, LLC - www.adj.com - 5P Hex/5P Hex Pearl User Manual Page 7