ADJ 32 Hex Panel IP User guide

32 HEX PANEL IP
32 HEX PANEL IP PEARL
User Instructions
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa tion. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:
· Reorient or relocate the device.
· Increase the separation between the device and the receiver.
· Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of
their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
-
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document may be available online. Please check www.adj.com for the latest revision/update of this manual before beginning installation and/or programming.
Date
12/17/18 1 1.08
03/14/19
07/09/19
Document Version
1.2
1.3
Software Version >
1.09
1.11
DMX Channel Mode
6/10/11/ 16/48/96
6/10/11/16/ 48/57/96
N/C
Notes
Initial Version
57 Channel Mode Added
Strobe Mode Added
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical prod­ucts when they are not in use. To avoid power consumption in idle mode, disconnect all electrical
equipment from power when not in use. Thank you!
32 Hex Panel IP/32 Hex Panel IP Pearl Table of Contents
Introduction Features I Warranty Registration I Installation
Safety Precautions
IP Notice Installation
Overview
Connections
DMX Set Up DMX Addressing DMX Modes
Color Macro Chart
3
4
5
7
8
9
10
11
12
13
18
System Menu
Master-Slave Set Up Pixel Zones
Dimmer Curve Chart
Dimensional Drawings
Barn Door Installation
Barn Door Dimensional Drawings
Power Linking I Trouble Shooting I Cleaning Limited Warranty (USA Only) Technical Specications
20
27
27
28
29
30 31 32 33 34
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 2
32 Hex Panel IP/32 Hex Panel IP Pearl Introduction
Unpacking: Thank you for purchasing the 32 Hex Panel IP/32 Hex Panel IP Pearl by ADJ Products, LLC. Every unit has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories nec- essary to operate the unit has arrived intact. In the case damage has been found or parts are missing,
please contact our toll free customer support number for further instructions. Do not return this unit to
your dealer without rst contacting customer support.
Introduction: The 32 Hex Panel IP/32 Hex Panel IP Pearl is a DMX intelligent, IP rated LED wash fixture. This xture can be used in a stand alone mode or connected in a Master/Slave conguration. This fixture has five operating modes: RGBWA + UV dimmer mode, Static Color mode, Auto Run mode, Color Macro mode, and DMX control.
This product is intended to be used by professionally trained personnel only and is not suitable for private use.
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit
forums.adj.com with questions, comments or suggestions.
Parts: To purchase parts online visit http://parts.americandj.com
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST Voice: 323-582-2650 | Fax: 323-582-2941 | support@adj.com
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | support@adj.eu
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 3
32 Hex Panel IP/32 Hex Panel IP Pearl Features
• Multi-Colors
• Five Operating Modes
• Electronic Dimming 0-100%
• DMX-512 protocol
• IP65 Locking 5-Pin XLR Connections In/Out
• Multiple DMX Channel Modes
• Multiple Unit Power Linking (See page 32)
Included: 1 x IP65 Locking Power Cable 2 x Safety Cables 1 x Magnetic Removable Frost Filter
32 Hex Panel IP/32 Hex Panel IP Pearl Warranty Registration
The 32 Hex Panel IP/32 Hex Panel IP Pearl carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. num­ber must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping car­ton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All packages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
32 Hex Panel IP/32 Hex Panel IP Pearl Installation
The unit should be mounted using a mounting clamp (not provided), axing it to the mounting bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. ALWAYS use safety cables that can hold 12 times the weight of the unit when installing the xture. Note: 2 safety cables are pro-
vided, one safety cable is for the unit itself, the second safety cable is for the LED array cover.
This equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
Ensure ALL connections and end caps are properly sealed with a non-conductive dielectric grease (available at most electrical suppliers) to prevent water ingress/condensation and/or corrosion.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 4
32 Hex Panel IP/32 Hex Panel IP Pearl Safety Precautions
FOR YOUR OWN PERSONAL SAFETY, PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY
BEFORE YOU ATTEMPT TO INSTALL OR OPERATE THIS UNIT!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG THE FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING FIXTURE! NEVER TOUCH THE FIXTURE DURING OPERATION AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF ENVIROMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
• Be sure that the local power outlet is compatible with the required voltage for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 32 for cleaning details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when the appliance does not appear to operate normally or exhibits a marked change in performance.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 5
32 Hex Panel IP/32 Hex Panel IP Pearl Safety Precautions
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!
FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT FROM THE UV LED.
WEAR PROPER EYE AND SKIN PROTECTION.
AVOID PROLONGED PERIODS OF EXPOSURE TO THE UV LED.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN.
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER.
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV) LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT.
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 6
32 Hex Panel IP/32 Hex Panel IP Pearl IP Notice
IP65 RATED
An IP rated lighting xture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that eectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers dene the degree of protection. The rst digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the xture and the second digit (Water Protection) indicates the extent of protection against water entering the xture. An IP65 rated lighting xture is one, which has been designed and tested to protect against the ingress of dust (6) and high-pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
NOT suitable for marine and/or coastal environment installations. Installing this xture in a marine and/or coastal environment may cause corrosion and/ or excessive wear to the interior and/or exterior components of the xture.
Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subJect to any warranty claims and/or repairs.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 7
32 Hex Panel IP/32 Hex Panel IP Pearl Installation
OPTIONAL CLAMP (Not Included)
1
ADJUSTABLE MOUNTING BRACKET
2
OPTIONAL OMEGA BRACKET (Not Included)
3
The 32 Hex Panel IP is fully operational in three dierent mounting positions; hanging upside-down, mounted sideways on trussing, or set on a at level surface. Be sure this xture is kept at least 12m (40ft) away from any ammable materials (decoration etc.). ALWAYS use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp
fails.
Screw one clamp via a M12 screw and nut into the Omega holder. Insert the quick-lock fasteners of the Omega holder into the respective holes of the adjustable mounting bracket. Tighten the quick­lock fasteners fully clockwise. Pull the safety-cable through the openings located on the rear of the unit and over the trussing system or a safe xation spot. Insert the end in the carabine and tighten
the safety screw.
Always ensure that the unit is rmly xed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. ALWAYS use safety cables that can hold 12 times the weight of the unit when installing the xture. This equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
Ensure ALL connections and end caps are properly sealed with a non-conductive dielectric grease (available at most electrical suppliers) to prevent water ingress/condensation and/or corrosion.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 8
32 Hex Panel IP/32 Hex Panel IP Pearl Overview
LCD Screen Mode Button Up Button
Down Button
Safety Cable Attachment Point
Enter Button
Safety Cable Attachment Point
Gore Valve
IP65 Locking Power Connector In IP65 Locking 5-Pin XLR Connector In
IP65 Locking Power Connector Out IP65 Locking 5-Pin XLR Connector Out
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 9
32 Hex Panel IP/32 Hex Panel IP Pearl Connections
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 10
32 Hex Panel IP/32 Hex Panel IP Pearl DMX Set Up
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The 32 Hex Panel IP/32 Hex Panel IP Pearl can be controlled via DMX-512 protocol. The DMX address is set on the back panel of the 32 Hex Panel IP/32 Hex Panel IP Pearl. Your unit and your DMX controller require a standard 5-pin XLR connec­tor for data input and data output. We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all
pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Special Note: Line Termination.
When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED AND ONLY IP65 RATED POWER AND DATE CABLES MUST BE USED.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 11
32 Hex Panel IP/32 Hex Panel IP Pearl DMX Addressing
All xtures should be given a DMX starting address when using a DMX controller, so the correct xture responds to the correct control signal. This digital starting address is the channel number from which the xture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set dierent addresses for each individual xture. Setting all xtures to the same DMX address will cause all xtures to react in the same way, in other words, changing the settings of one channel will aect all the xtures
simultaneously.
If you set each xture to a dierent DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of DMX channels of each xture. That means changing the settings of one channel will only aect the selected xture.
In the case of the 32 Hex Panel IP/32 Hex Panel IP Pearl, when in 6 channel mode you should set the starting DMX address of the rst unit to 1, the second unit to 7 (6 + 1), the third unit to 13 (7 + 6), and so on. (See chart below for more details.)
Channel Mode
Unit1
Address
Unit2
Address
Unit3
Address
Unit4
Address
6 channels 1 7  13 19
10 channels 1 11  21 31
11 channels 1 12  22 32 
16 channels 1
48 channels 1
57 channels 1
96 channels 1
17 33
49 97
58 115
97 193
49
145
172
289
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 12
32 Hex Panel IP/32 Hex Panel IP Pearl DMX Modes
6 CH 10 CH 11 CH 16 CH 48 CH 96 CH
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
57 CH
1
2
3
1
2
3
4
5
6
VALUES FUNCTIONS
RED (ALL LEDS)
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
0-100%
GREEN (ALL LEDS)
0-100%
BLUE (ALL LEDS)
0-100%
WHITE (ALL LEDS)
0-100%
AMBER (ALL LEDS)
0-100%
UV (ALL LEDS)
0-100%
RED (ZONE #1)
0-100%
RED FINE (ZONE #1)
GREEN (ZONE #1)
0-100%
GREEN FINE (ZONE #1)
BLUE (ZONE #1)
0-100%
BLUE FINE (ZONE #1)
WHITE (ZONE #1)
4
5
6
7
8
9
4
5
6
7
8
9
7
8
9
10
11
12
13
14
15
16
17
18
000-255
000-255
000-255
000-255
000-255
000-255
0-100%
WHITE FINE (ZONE #1)
AMBER (ZONE #1)
0-100%
AMBER FINE (ZONE #1)
UV (ZONE #1)
0-100%
UV FINE (ZONE #1)
RED (ZONE #2)
0-100%
RED FINE (ZONE #2)
GREEN (ZONE #2)
0-100%
GREEN FINE (ZONE #2)
BLUE (ZONE #2)
0-100%
BLUE FINE (ZONE #2)
WHITE (ZONE #2)
10
10
19
20
000-255
0-100%
WHITE FINE (ZONE #2)
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 13
32 Hex Panel IP/32 Hex Panel IP Pearl DMX Modes
6 CH 10 CH 11 CH 16 CH 48 CH 96 CH57 CH
11
12
13
14
15
16
17
11
12
13
14
15
16
17
21
22
23
24
25
26
27
28
29
30
31
32
33
VALUES FUNCTIONS
AMBER (ZONE #2)
000-255
000-255
000-255
000-255
000-255
000-255
000-255
0-100%
AMBER FINE (ZONE #2)
UV (ZONE #2)
0-100%
UV FINE (ZONE #2)
RED (ZONE #3)
0-100%
RED FINE (ZONE #3)
GREEN (ZONE #3)
0-100%
GREEN FINE (ZONE #3)
BLUE (ZONE #3)
0-100%
BLUE FINE (ZONE #3)
WHITE (ZONE #3)
0-100%
WHITE FINE (ZONE #3)
AMBER (ZONE #3)
0-100%
18
19
20
21
22
23
24
18
19
20
21
22
23
24
34
35
36
37
38
39
40
41
42
43
44
45
46
47
000-255
000-255
000-255
000-255
000-255
000-255
000-255
AMBER FINE (ZONE #3)
UV (ZONE #3)
0-100%
UV FINE (ZONE #3)
RED (ZONE #4)
0-100%
RED FINE (ZONE #4)
GREEN (ZONE #4)
0-100%
GREEN FINE (ZONE #4)
BLUE (ZONE #4)
0-100%
BLUE FINE (ZONE #4)
WHITE (ZONE #4)
0-100%
WHITE FINE (ZONE #4)
AMBER (ZONE #4)
0-100%
AMBER FINE (ZONE #4)
UV (ZONE #4)
0-100%
48
UV FINE (ZONE #4)
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 14
32 Hex Panel IP/32 Hex Panel IP Pearl DMX Modes
6 CH 10 CH 11 CH 16 CH 48 CH 96 CH57 CH
25
26
27
28
29
30
31
25
26
27
28
29
30
31
49
50
51
52
53
54
55
56
57
58
59
60
61
VALUES FUNCTIONS
RED (ZONE #5)
000-255
000-255
000-255
000-255
000-255
000-255
000-255
0-100%
RED FINE (ZONE #5)
GREEN (ZONE #5)
0-100%
GREEN FINE (ZONE #5)
BLUE (ZONE #5)
0-100%
BLUE FINE (ZONE #5)
WHITE (ZONE #5)
0-100%
WHITE FINE (ZONE #5)
AMBER (ZONE #5)
0-100%
AMBER FINE (ZONE #5)
UV (ZONE #5)
0-100%
UV FINE (ZONE #5)
RED (ZONE #6)
0-100%
32
33
34
35
36
37
38
32
33
34
35
36
37
38
62
63
64
65
66
67
68
69
70
71
72
73
74
75
000-255
000-255
000-255
000-255
000-255
000-255
000-255
RED FINE (ZONE #6)
GREEN (ZONE #6)
0-100%
GREEN FINE (ZONE #6)
BLUE (ZONE #6)
0-100%
BLUE FINE (ZONE #6)
WHITE (ZONE #6)
0-100%
WHITE FINE (ZONE #6)
AMBER (ZONE #6)
0-100%
AMBER FINE (ZONE #6)
UV (ZONE #6)
0-100%
UV FINE (ZONE #6)
RED (ZONE #7)
0-100%
RED FINE (ZONE #7)
GREEN (ZONE #7)
0-100%
76
GREEN FINE (ZONE #7)
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 15
32 Hex Panel IP/32 Hex Panel IP Pearl DMX Modes
6 CH 10 CH 11 CH 16 CH 48 CH 96 CH57 CH
39
40
41
42
43
44
39
40
41
42
43
44
77
78
79
80
81
82
83
84
85
86
87
88
VALUES FUNCTIONS
BLUE (ZONE #7)
000-255
000-255
000-255
000-255
000-255
000-255
0-100%
BLUE FINE (ZONE #7)
WHITE (ZONE #7)
0-100%
WHITE FINE (ZONE #7)
AMBER (ZONE #7)
0-100%
AMBER FINE (ZONE #7)
UV (ZONE #7)
0-100%
UV FINE (ZONE #7)
RED (ZONE #8)
0-100%
RED FINE (ZONE #8)
GREEN (ZONE #8)
0-100%
GREEN FINE (ZONE #8)
45
46
47
48
77
45
46
47
48
49
89
90
91
92
93
94
95
96
000-255
000-255
000-255
000-255
000-031 032-063 064-095 096-127 128-159 160-191 192-223 224-255
BLUE (ZONE #8)
0-100%
BLUE FINE (ZONE #8)
WHITE (ZONE #8)
0-100%
WHITE FINE (ZONE #8)
AMBER (ZONE #8)
0-100%
AMBER FINE (ZONE #8)
AMBER (ZONE #8)
0-100%
UV FINE (ZONE #8)
STROBE
LED OFF LED ON STROBING SLOW - FAST LED ON PULSE STROBING SLOW - FAST LED ON RANDOM STROBING SLOW - FAST LED ON
7
8
88
99
50
51
000-255
000-255
MASTER DIMMER 8BIT
0-100%
MASTER DIMMER FINE 16BIT
0-100%
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 16
32 Hex Panel IP/32 Hex Panel IP Pearl DMX Modes
6 CH 10 CH 11 CH 16 CH 48 CH 96 CH57 CH
10
11
52
VALUES FUNCTIONS
COLOR MACROS
SEE PAGES 18-19 FOR COLOR MACRO CHART000-255
AUTO PROGRAMS
000-010 011-026 027-043 044-060 061-076 077-093 094-110 111-126 127-143 144-160 161-176 177-193 194-210 211-226 227-255
NO FUNCTION DREAM METEOR FADE CHANGE FLOW 1 FLOW 2 FLOW 3 FLOW 4 FLOW 5 FLOW 6 FLOW 7 FLOW 8 FLOW 9 NO FUNCTION
12
13
14
109
15
53
54
55
56
000-255
000-255
000-020 021-040 041-060 061-080 081-100 101-255
000-015 016-030 031-045 046-060 061-075 076-090 091-105 106-120 121-135 136-150 151-165 166-180 181-195 196-210 211-225 226-255
AUTO PROGRAM SPEED
SLOW - FAST
AUTO PROGRAM FADE*
SLOW - FAST
DIMMER MODE
STANDARD STAGE TV ARCHITECTURAL THEATRE DEFAULT TO UNIT SETTING
LED REFRESH RATE
DEFAULT TO UNIT SETTING 900HZ 1000HZ 1100HZ 1200HZ 1300HZ 1400HZ 1500HZ 2500HZ 4000HZ 5000HZ 10000HZ 15000HZ 20000HZ 25000HZ OFF
GAMMA
000-020 021-040
161110
57
041-060 061-080 081-100 101-120 121-255
DEFAULT TO UNIT SETTING
2.0
2.2
2.4
2.6
2.8 OFF
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 17
32 Hex Panel IP/32 Hex Panel IP Pearl Color Macro Chart
Color No. DMX
VALUE
Color33 129-132 255 206 143 0
Color34 133-136 254 177 153 0
Color35 137-140 254 192 138 0
Color36 141-144 254 165 98 0
Color37 145-148 254 121 0 0
Color38 149-152 176 17 0 0
Color39 153-156 96 0 11 0
Color40 157-160 234 139 171 0
Color41 161-164 224 5 97 0
Color42 165-168 175 77 173 0
Color43 169-172 119 130 199 0
Color44 173-176 147 164 212 0
Color45 177-180 88 2 163 0
Color46 181-184 0 38 86 0
Color47 185-188 0 142 208 0
Color48 189-192 52 148 209 0
Color49 193-196 0 46 35 0
Color50 197-200 8 107 222 0
Color51 201-204 107 156 231 0
Color52 205-208 165 198 247 0
Color53 209-212 0 83 115 0
Color54 213-216 0 97 166 0
Color55 217-220 1 100 167 0
Color56 221-224 0 40 86 0
Color57 225-228 209 219 182 0
Color58 229-232 42 165 85 0
Color59 233-236 255 0 0 0
Color60 237-240 0 255 0 0
Color61 241-244 0 0 255 0
Color62 245-248 0 0 0 255
Color63 249-252 0 0 0 0
Color64 253-255 0 0 0 0
Color No. DMX
VALUE
OFF 0 0 0 0 0
Color1 1-4 80 255 234 80
Color2 5-8 80 255 164 80
Color3 9-12 77 255 112 77
Color4 13-16 117 255 83 83
Color5 17-20 160 255 77 77
Color6 21-24 223 255 83 83
Color7 25-28 255 243 77 77
Color8 29-32 255 200 74 74
Color9 33-36 255 166 77 77
Color10 37-40 255 125 74 74
Color11 41-44 255 97 77 74
Color12 45-48 255 71 77 71
Color13 49-52 255 83 134 83
Color14 53-56 255 93 182 93
Color15 57-60 255 96 236 96
Color16 61-64 238 93 255 93
Color17 65-68 196 87 255 87
Color18 69-72 150 90 255 90
Color19 73-76 100 77 255 77
Color20 77-80 77 100 255 77
Color21 81-84 67 148 255 67
Color22 85-88 77 195 255 77
Color23 89-92 77 234 255 77
Color24 93-96 158 255 144 144
Color25 97-100 255 251 153 153
Color26 101-104 255 175 147 147
Color27 105-108 255 138 186 138
Color28 109-112 255 147 251 147
Color29 113-116 151 138 255 138
Color30 117-120 100 138 255 138
Color31 121-124 138 169 255 138
Color32 125-128 255 255 255 255
RED GREEN BLUE WHITE
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 18
RGBWA+UV COLOR INTENSITY
AMBER UV
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
32 Hex Panel IP/32 Hex Panel IP Pearl Color Macro Chart
Color No. DMX
VALUE
Color33 129-132 255 206 143 0
Color34 133-136 254 177 153 0
Color35 137-140 254 192 138 0
Color36 141-144 254 165 98 0
Color37 145-148 254 121 0 0
Color38 149-152 176 17 0 0
Color39 153-156 96 0 11 0
Color40 157-160 234 139 171 0
Color41 161-164 224 5 97 0
Color42 165-168 175 77 173 0
Color43 169-172 119 130 199 0
Color44 173-176 147 164 212 0
Color45 177-180 88 2 163 0
Color46 181-184 0 38 86 0
Color47 185-188 0 142 208 0
Color48 189-192 52 148 209 0
Color49 193-196 0 46 35 0
Color50 197-200 8 107 222 0
Color51 201-204 107 156 231 0
Color52 205-208 165 198 247 0
Color53 209-212 0 83 115 0
Color54 213-216 0 97 166 0
Color55 217-220 1 100 167 0
Color56 221-224 0 40 86 0
Color57 225-228 209 219 182 0
Color58 229-232 42 165 85 0
Color59 233-236 255 0 0 0
Color60 237-240 0 255 0 0
Color61 241-244 0 0 255 0
Color62 245-248 0 0 0 255
Color63 249-252 0 0 0 0
Color64 253-255 0 0 0 0
RED GREEN BLUE WHITE
RGBWA+UV COLOR INTENSITY
AMBER UV
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
255
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
255
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 19
32 Hex Panel IP/32 Hex Panel IP Pearl System Menu
SYSTEM MENU
The xture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made. (See image below) During normal operation, pressing the MENU button once will access the xture’s main menu. Once in the main menu, you can navigate through the dierent functions and access the sub-menus with the UP and DOWN buttons. When you reach a eld that requires adjusting, press the ENTER button to access that eld and use the UP and DOWN buttons to adjust the eld. Pressing the ENTER button once more will conrm your setting. You may exit the main menu at any time without making any adjustments by pressing the MENU
button.
LCD CONTROL PANEL LOCKOUT
When the Key Lock function is activated, the control panel will automatically lock after the time set under the LCD. Set submenu “Backlight”.
When the Key Lock function is set to ON, the control panel will lock and the display will show LOCKED*****”. Press and hold the MODE button for 3 seconds to unlock.
When the Key Lock function is set to ON1, the control panel will lock and the display will show LOCKED*****”. To unlock the display follow these steps:
1. When locked, the display will show: LOCKED*****.
2. Press the UP button, and the display will change to: LOCKED**** (one * disappears).
3. Press the DOWN button, and the display will change to: LOCKED*** (two * disappears).
4. Press the UP button, and the display will change to: LOCKED** (three * disappears).
5. Press the DOWN button, and the display will change to: LOCKED* (four * disappears).
6. Press the ENTER buttton, and the display will be unlocked.
If the button sequence was entered correctly, the display and control panel will unlock. If the button sequence was entered incorrectly, the display will return to the DMX addess display.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 20
32 Hex Panel IP/32 Hex Panel IP Pearl System Menu
MENU SUBMENU OPTIONS/VALUES (DEFAULT SHADED) DESCRIPTION
Display Menu
Set ADDR
User Mode
Function
Info
Update Wait ADJ
V1.08
Set ADDR XXX
CHXX 6/10/11/16/48/57/96
DimCurve NODMX Hold /Blackout / Program
AUTO RUN FQN: XX
1. STATC
001~509
Standard/Stage/TV/Architec/Theatre
01~99
R/G/B/RG/GB/RB/RGB/BLAC
DMX Addressing
DMX Channel Modes
Dimmer Curve Setting DMX Lost Setting
Auto Run Programs
Static Color Mode
F000-255
2. CHANG
15 Color Change
15 Color Change Mode
SP01-99 F000-255
3. CHANG
30 Color Change
30 Color Change Mode
SP01-99 F000-255
4. FADE
Color Fade
Color Fade Mode
SP01-99 F000-255
Macros 00
LCD.Set
00~63
Backlight Key Lock
05~60m ON/ON1/OFF
Color Macro Mode
LCD Display Settings
DisFlash ON/OFF
DFSET OFF
TEMP Fahren
Settings WhiteBal
ON/OFF
Fahren Celsius
Red: 000-255 Green: 000-255 Blue: 000-255 White: 000-255
Default Reset
Temperature Display Setting
White Balance Setting
Amber: 000-255 UV: 000-255
Fan Mode Auto / Low / High Fan Setting
Fre_hz
Gamma
Info TimeInfo
900/1000/1100/1200/1300/1400/1500/2500/4000/ 5000/10k /15k /20k /25k
2.0 / 2.2 / 2.4 / 2.6 / 2.8
Current
TotalTim
LastClea
TimerPIN
Set LED Refresh Rate
Set Gamma Brightness
Current Running Time (Hours)
Total Running Time (Hours)
Last Time The Running Time Was Cleared (Hours)
Current Time Clear: (Password=050)
Total Time Clear: (Password=060)
Info TempInfo
Info Model Inf
Info Software
XXX
32 Hex Panel
UXXX
Current Running Temperature
Model Name
Current Software Version
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 21
32 Hex Panel IP/32 Hex Panel IP Pearl System Menu
MENU SUBMENU OPTIONS/VALUES (DEFAULT SHADED) DESCRIPTION
Slave
Strobe Mode Strobing
Manual
Slave
Random 1 (All LED Strobing) Random 2 (Zone Strobing)
Manual Dimmer: 000~255
Manual AllRed: 000~255 AllGreen: 000~255 AllBlue: 000~255 AllWhite: 000~255 AllAmber: 000~255 AllUV: 000~255
Manual Red1: 000~255 Green1: 000~255 Blue1: 000~255 White1: 000~255 Amber1: 000~255 UV1: 000~255
Manual Red2: 000~255 Green2: 000~255 Blue2: 000~255 White2: 000~255 Amber2: 000~255 UV2: 000~255
Manual Red3: 000~255 Green3: 000~255 Blue3: 000~255 White3: 000~255 Amber3: 000~255 UV3: 000~255
Manual Red4: 000~255 Green4: 000~255 Blue4: 000~255 White4: 000~255 Amber4: 000~255 UV4: 000~255
Manual Red5: 000~255 Green5: 000~255 Blue5: 000~255 White5: 000~255 Amber5: 000~255 UV5: 000~255
Manual Red6: 000~255 Green6: 000~255 Blue6: 000~255 White6: 000~255 Amber6: 000~255 UV6: 000~255
Manual Red7: 000~255 Green7: 000~255 Blue7: 000~255 White7: 000~255 Amber7: 000~255 UV7: 000~255
Manual Red8: 000~255 Green8: 000~255 Blue8: 000~255 White8: 000~255 Amber8: 000~255 UV8: 000~255
Strobing: 000~255
Slave Setting
Manual Control
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 22
32 Hex Panel IP/32 Hex Panel IP Pearl System Menu
DMX Addressing:
Operating through a DMX controller gives the user the freedom to create their own programs tailored to their own individual needs.
1. To run your fixture in DMX mode press the MODE button and press the UP or DOWN buttons until “Set Addr” is displayed and press ENTER. The current DMX address will now be displayed.
2. Use the UP or DOWN buttons to find your desired DMX address, and press ENTER.
DMX Channel Modes - With this function, you can select your desired DMX channel mode. The 32 Hex Panel IP/32 Hex Panel IP Pearl has 7 DMX channel modes: 6/10/11/16/48/57/96.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “User Mode” is displayed and press ENTER. The current DMX channel mode will now be displayed.
2. Press the UP or DOWN buttons to scroll through the 7 DMX channel modes. When you have found your desired DMX channel mode, press ENTER to conrm your selection or press the MODE button to exit. Please see pages 13-17 for the DMX modes, values, and traits.
Dimmer Curve Setting:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Function” is displayed, and press ENTER. Press the UP or DOWN buttons until DimCurve” is displayed, and press ENTER.
2. Use the UP or DOWN buttons to scroll through the dimmer curves. Press ENTER to confirm your selection or press the MODE button to exit.
3. There are 5 dimmer curve settings to choose from. Please see the Dimmer Curve Diagram Chart on page 28 to see the settings and their respective beginning and ending fade times.
DMX Lost Setting:
This mode is used as a precaution mode, that in case the DMX signal is lost, the operating mode chosen in the setup is the running mode the xture will go into when the DMX signal is lost. You can also set this as the operating mode you would like the unit to return to when power is applied.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Function” is displayed, and press ENTER. Press the UP or DOWN buttons until “NODMX” is displayed and press ENTER.
2. Use the UP and DOWN buttons to scroll through the 3 DMX standing states.
“Hold” - If the DMX signal is lost or interrupted, the xture will stay in the last DMX set up. If power is applied and this mode is set, the unit will automatically go into the last DMX set up.
“Blackout” - If the DMX signal is lost or interrupted, the unit will automatically go into stand by mode.
“Program” - If the DMX signal is lost or interrupted, the unit will automatically go into Auto Run mode.
3. Use the UP and DOWN buttons to nd your desired DMX state and press ENTER to conrm your selection or press the MODE button to exit.
Auto Run Mode:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons so that “Menu Function” is displayed, and press ENTER. Press the UP or DOWN buttons until “AUTO RUN FQN” is displayed and press ENTER.
2. Use the UP or DOWN buttons to scroll through the 99 Auto Run programs. Press ENTER to confirm your selection or press the MODE button to exit.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 23
32 Hex Panel IP/32 Hex Panel IP Pearl System Menu
Static Color Mode, Color Change Mode, and Color Fade Mode:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons so that “Menu Function” is displayed and press ENTER. Press the UP or DOWN buttons until ONE of the follow-
ing running modes is displayed:
“1. STATC” - Static Color Mode (Color adjustment and strobing) “2. CHANG” - 15 Color Change Mode (Color changing, change speed adjustment, & strobing) “3. CHANG” - 30 Color Change Mode (Color changing, change speed adjustment, & strobing) “4. FADE” - Color Fade Mode (Color fading, fade speed adjustment, & strobing)
Note: See the System Menu on page 21.
2. Press the ENTER button to select your desired running mode. Use the UP and DOWN buttons to make your desired adjustments. Press the ENTER button each time you are finished making adjustments in the current running mode.
Color Macro Mode:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Function” is displayed, and press ENTER.
2. Press the UP or DOWN buttons until “Macros” is displayed and press ENTER.
3. There are 63 colors to choose from. Use the UP and DOWN buttons for find your desired color.
4. Once you have found your desired color press the ENTER button. Press the MODE button to exit.
LCD Display Settings:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Function” is displayed, and press ENTER.
2. Press the UP or DOWN buttons until “LCD.Set” is displayed and press ENTER.
3. Use the UP and DOWN buttons to scroll through the options, and press ENTER to make your
selection.
Backlight - This lets you set how long the backlight display will stay on.
Key Lock - This lets you control the key lock feature.
“OFF” - The keypad is unlocked, simply press the MODE button to activate the keypad. “ON” - This is a simple keypad lock. “LOCKED *****” will be displayed. Press the MODE button
for at least 5 seconds to unlock the keypad. “ON1. This setting is used to prevent the accidental unlocking of the keypad. To unlock the keypad you will have to enter a passcode. “LOCKED *****” will be displayed. To unlock the keypad press UP, DOWN, UP, DOWN, & ENTER in that order. Every press of these buttons will delete an asterisk.
DisFlash - In this function you can activate the display flash.
Default Running Mode:
In this mode you can reset all function settings to their default modes.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu
Function” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “DFSET” displayed, and press ENTER.
3. Use the UP or DOWN button to toggle between “ON’ and “OFF”. To reset to the default settings, select “ON” and press ENTER.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 24
32 Hex Panel IP/32 Hex Panel IP Pearl System Menu
Unit Temperature - With this function you can switch the temperature setting between celsius or
fahrenheit.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu
Function” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Temp” is displayed and press ENTER.
3. Use the UP and DOWN buttons to switch between “Fahren” and “Celsius”.
4. Once you have found your desired setting press ENTER to confirm, or press MODE to exit.
White Balance Settings - With this function you can adjust RGBWA & UV colors to balance the
white color.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu
Function” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Settings WhiteBal” is displayed and press ENTER.
3. Use the UP and DOWN buttons to switch between the colors. When you have found the color you wish to adjust press ENTER. Use the UP or DOWN button to adjust the color values.
4. Once you have made your desired adjustment press ENTER.
Fan Setting - With this function you can adjust the fan speeds.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Function” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Fan Mode” is displayed and press ENTER.
3. Use the UP and DOWN buttons to scroll through different frequencies.
4. Once you have found your desired frequency press ENTER.
Frequency Setting - With this function you can adjust the dimming frequency.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Function” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Fre_hz” is displayed and press ENTER.
3. Use the UP and DOWN buttons to scroll through different frequencies.
4. Once you have found your desired frequency press ENTER.
Gamma Brightness Setting - With this function you can adjust the gamma brightness.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Function” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Gamma” is displayed and press ENTER.
3. Use the UP and DOWN buttons to scroll through different settings.
4. Once you have found your desired setting press ENTER.
Time Information:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Info” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “TimeInfo” is displayed and press ENTER.
3. Use the UP and DOWN buttons to scroll through the time information menu.
• “TimeInfo Current” - This will display the current running time of the fixture in hours.
• “TimeInfo TotalTim” - This will display the total running time of the fixture in hours.
“TimeInfo LastClea” - This will display the last time the running time was cleared.
“TimeInfo TimerPIN” - This menu function will allow you to clear the current running time and
total running time.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 25
32 Hex Panel IP/32 Hex Panel IP Pearl System Menu
Temperature Information:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Info” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “TempInfo” is displayed and press ENTER.
3. The current temperature will now be displayed. Press the MENU button to exit.
Model Information:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Info” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Model Inf” is displayed and press ENTER.
3. The model name will now be displayed. Press the MENU button to exit.
Software Information:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Menu Info” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Software” is displayed and press ENTER.
3. The current software version will now be displayed. Press the MENU button to exit.
Slave Setting - With this function you can set the unit as a “Slave” in Master-Slave configuration.
1. Plug the fixture in and press the MODE button and press the UP or DOWN buttons until “Slave” is displayed, and press ENTER.
2. The unit is now set as a “Slave” in a Master-Slave configuration.
Strobe Mode - With this function you switch between all LED strobing or Zone strobing. Note: Strobe Mode works with DMX only. The strobe mode setting will only work with “Random Strobing” in the “Strobe” channel.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until “Strobe Mode” is displayed, and press ENTER.
2. Use the UP or DOWN buttons to switch between Random 1 and Random 2.
3. Random 1 has all LEDs strobing together, and Random 2 will zone strobe.
4. Select your desired strobe mode and press the ENTER button. Press the MODE button to exit.
Manual Control - With this function you can manually adjust the dimmer, colors, and strobing.
1. Plug the fixture in and press the MODE button and press the UP or DOWN buttons until “Manual” is displayed, and press ENTER.
2. Press the UP or DOWN buttons to scroll through dimmer, colors, and strobe.
Note: See the system menu on page 22.
3. Press ENTER to select the function you woud like to adjust and use the UP and DOWN buttons to make the adjustments.
4. Once you have made your desired adjustments, press the ENTER button.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 26
32 Hex Panel IP/32 Hex Panel IP Pearl Master-Slave Configuration
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-Slave set-up. In a Master-Slave set up one unit will act as the controlling unit and the others will react to the controlling units built-in programs. Any unit can act as a Master or as a Slave however, only one unit can be programmed to
act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR data cables to link your units together. Remember that the Male XLR connector is the input and the Female XLR connector is the ouput. The first unit in the chain (master) will use the female XLR connector only. The last unit in the chain will use the male XLR connector only.
2. Connect the rst “Slave” unit to the “Master.”
3. Set the “Master” unit to your desired mode of operation. On the “Slave” unit(s) press the MODE button and press the UP or DOWN buttons until “Slave” is displayed and press ENTER.
4. The slave unit(s) will now follow the master unit.
32 Hex Panel IP/32 Hex Panel IP Pearl Pixel Zones
Pixel Zones 1-8
1 1
1 1
5 5
5 5
2 2
2 2
6 6
6 6
3 3
3 3
7 7
7 7
4 4
4 4
8 8
8 8
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 27
32 Hex Panel IP/32 Hex Panel IP Pearl Dimmer Curve Chart
DIMMER
100%
50%
10%
0%
0 Sec
Rise Time Down Time
Time (ms)
0 sec Fade Time 1 sec Fade Time
255 255
Dimming Curve
Ramp Effect
0 0
Rise Time (ms) Down Time (ms) Rise Time (ms) Down Time (ms)
Standard (default) 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 28
32 Hex Panel IP/32 Hex Panel IP Pearl Dimensional Drawings
6.5” / 165.5mm
6.1” / 155.5mm
9” / 229mm
7.28” / 185mm
8.9” / 225.5mm
14” / 354mm
12.9” / 329mm
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 29
32 Hex Panel IP/32 Hex Panel IP Pearl Barn Door Installation
Barn Doors Not Included
1. Install and secure the included magnetic LED array cover. (Note:
Not required when using Barn Doors)
Barn Doors
LED Array Cover
32 Hex Panel IP
2. Place the Barn Door attach­ment over the front of the unit.
Line up the 4 Barn Door thumb
screws with the thumb screw
holes located on each side of unit (2 on each side). Screw thumb screws in and tighten. DO
NOT overtighten.
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 30
32 Hex Panel IP/32 Hex Panel IP Pearl Barn Door Dimensional Drawings
Barn Doors Not Included
9.49” / 241.1mm
15.56” / 395.3mm
1.86” / 47.3mm
10.15” / 257.8mm
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 31
32 Hex Panel IP/32 Hex Panel IP Pearl Multiple Unit Power Linking
With this feature you can connect the xtures to one another using the power cable input and
output sockets. NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
32 Hex Panel IP/32 Hex Panel IP Pearl Trouble Shooting
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right connectors; it does matter which way the inputs and outputs are connected.
32 Hex Panel IP/32 Hex Panel IP Pearl Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in. Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew).
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 32
32 Hex Panel IP/32 Hex Panel IP Pearl Limited Warranty (USA Only)
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing
defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#) before sending back the product–please
contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner
which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the
instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check up.
During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without
any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products
described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties
and written descriptions of warranty terms and conditions heretofore published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
• Non L.E.D. Lighting Products = 1-year (365 days) Limited Warranty (Such as: Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
• Laser Products = 1 Year (365 Days) Limited Warranty (excluding laser diodes which have a 6 month limited
warranty)
• L.E.D. Products = 2-year (730 days) Limited Warranty (excluding batteries which have a 180 day limited warranty).
Note: 2 Year Warranty only applies to purchases within the United States.
• StarTec Series = 1 Year Limited Warranty (excluding batteries which have a 180 day limited warranty).
• ADJ DMX Controllers = 2 Year (730 Days) Limited Warranty
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 33
32 Hex Panel IP/32 Hex Panel IP Pearl Technical Specifications
Model: 32 Hex Panel IP Pearl
Voltage: 100V ~ 240V/50~60Hz LEDs: 32 x 12W 6-in-1 HEX LED’s IP Rating: IP65 Working Position: Any safe working position Power Draw: 298W Dimensions: 6.5” (L) x 14” (W) x 9” (H)
165.5 x 354 x 229mm Weight: 24.25lbs. / 11kg Colors: RGBWA+UV Color Mixing DMX Channels: 7 DMX Modes: 6/10/11/16/48/57/96 Warranty: 2 Year (730 days)
Please Note: Specications and improvements in the design of this unit and this manual are subject to change without notice.