instructions herein ar
product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection
claimed includes all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this document may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of
their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as
a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
e subject to change without notice. ADJ Products, LLC logo and identifying
DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical
equipment from power when not in use. Thank you!
12PX Hex/12PX Hex PearlTable of Contents
Introduction
Features/Warranty Registration/Installation
Safety Precautions
Layout
DMX Set Up
DMX Addressing
DMX Channel Modes
Color Macro Chart
System Menu
Operating Instructions
Primary-Secondary Configuration
3
4
5
7
8
10
11
12
14
15
17
Dotz Par RF Operation
Dimmer Curve Chart
Dimensional Drawings
Power Linking/Trouble Shooting/Cleaning
Warranty
Specications
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 2
18
19
20
21
22
23
12PX Hex/12PX Hex PearlIntroduction
Unpacking: Thank you for purchasing the 12PX Hex/12PX Hex
12PX Hex/12PX Hex Pearl has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the
carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are
missing, please contact our toll free customer support number for further instructions. Do not return
this unit to your dealer without rst contacting customer support.
Introduction: The 12PX Hex/12PX Hex Pearl is a DMX intelligent, LED par fixture. This fixture can
be used in a stand alone mode or connected in a Primary/Secondary configuration. This par has five
operating modes: Sound Active mode, Program mode, RGBWA + UV dimmer mode, Static Color
mode, and DMX control mode. The 12PX Hex/12PX Hex Pearl have 4 DMX channel modes; 6, 7, 8,
& 12.
Customer Support: ADJ Products, LLC provides a customer support line, to provide set up help
and to answer any question should you encounter problems during your set up or initial operation.
You may also visit us on the web at www.adj.com for any comments or suggestions. Service
Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacific Standard Time.
Voice: (323) 582-2650
Fax: (323) 582-2941
Pearl by ADJ Products, LLC. Every
E-mail:
Warning! To prevent or reduce the risk of electrical shock or re, do not expose this unit to rain or
moisture.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself,
doing so will void your manufactures warranty. In the unlikely event your unit may require service
please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
support@americandj.com
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 3
12PX Hex/12PX Hex PearlFeatures
• Multi-Colors
• Five Operating Modes
• Electronic Dimming 0-100%
• 5 Dimmer Curves
• DMX-512 protocol
• 3-Pin & 5-Pin DMX Connection
• Four DMX Modes: 6 Channel Mode, 7 Channel Mode, 8 Channel Mode, and 12 Channel Mode.
• Dotz Par RF Compatiable (Not Included)
• Multiple Unit Power Linking (See page 21)
Included:
1 x Power Cable
1 x Gel Frame Holder & Gel Frame
12PX Hex/12PX Hex PearlWarranty Registration
The 12PX Hex and 12PX Hex Pearl carry a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the problem as well as the
R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit
is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A.
number by contacting our customer support team on our customer support number. All packages
returned to the service department not displaying a R.A. number on the outside of the package will be
returned to the shipper.
12PX Hex/12PX Hex PearlInstallation
The unit should be mounted using a mounting clamp (not provided), axing it to the mounting
bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration
and slipping while operating. Always ensure that the structure to which you are attaching the unit is
secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable
that can hold 12 times the weight of the unit when installing the xture. The equipment must be
installed by a professional, and it must be installed in a place where it is out of the reach of people’s
grasp.
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 4
12PX Hex/12PX Hex PearlSafety Precautions
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to
remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6”
(15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product outdoors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by
items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 21
for cleaning details.
• Heat -The appliance should be situated away from heat sources such as radiators, heat registers,
stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the fixture.
C. The fixture has been exposed to rain or water.
D. The fixture does not appear to operate normally or exhibits a marked change in performance.
E. The fixture has fallen and/or subjected to extreme handling.
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 5
12PX Hex/12PX Hex PearlSafety Precautions
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!
FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT FROM THE UV LED.
WEAR PROPER EYE AND SKIN PROTECTION.
AVOID PROLONGED PERIODS OF EXPOSURE TO THE UV LED.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN.
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER.
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV) LIGHT DIRECTLY WITH
OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT.
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE
DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE
DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE.
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 6
12PX Hex/12PX Hex PearlLayout
Power In Port
Power Out Port
3-Pin XLR Out Port
3-Pin XLR In Port
5-Pin XLR Out Port
5-Pin XLR In Port
LCD Screen
Mode Button
Up Button
Down Button
Enter Button
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 7
12PX Hex/12PX Hex PearlDMX Set Up
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signalerrors andavoids signal transmission problemsand interference. It is always advisableto connect a DMX terminal, (Resistance120 Ohm 1/4 W) between PIN 2 (DMX-)and PIN 3 (DMX +) of the last fixture.
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the
DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a
DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be
linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use
the shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The 12PX Hex and 12PX Hex Pearl can
be controlled via DMX-512 protocol. The 12PX Hex/12PX Hex Pearl has 4 DMX channel modes. The
DMX address is set on the back panel of the 12PX Hex/12PX Hex Pearl. Your unit and your DMX controller
require a standard 3-pin or 5-pin XLR connector for data input and data output (Figure 1). We recommend
Accu-Cable DMX cables. If you are making your own cables, be sure to use standard
110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector
on either end of the cable. Also remember that DMX cable must be daisy chained
and cannot be split.
Figure 1
Notice: Be sure to follow gures two and three when making your own cables. Do not use the ground
lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the
shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a
short circuit and erratic behavior.
XLR Male Socket
1 Ground
Figure 3
DMX512 OT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
COMMON
DMX +
DMX -
1 Ground
3 Hot
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 8
12PX Hex/12PX Hex PearlDMX Set Up
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
and PIN 3 (DMX +) of the last fixture.
Special Note: Line Termination.
When longer runs of cable are used, you may need to use a terminator
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is
connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted
in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable
terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
Termination reduces signal errors and
1
3
avoids signal transmission problems
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
Figure 4
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-512 data cables for DATA transmission in
place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting standard
5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available
at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 9
12PX Hex/12PX Hex PearlDMX Addressing
All xtures should be given a DMX starting address when using a DMX controller, so the correct xture
responds to the correct control signal. This digital starting address is the channel number from which
the xture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment
of this starting DMX address is achieved by setting the correct DMX address on the digital control
display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set dierent addresses
for each individual xture. Setting all xtures to the same DMX address will cause all xtures to react
in the same way, in other words, changing the settings of one channel will aect all the xtures
simultaneously.
If you set each xture to a dierent DMX address, each unit will start to “listen” to the channel number
you have set, based on the quantity of DMX channels of each xture. That means changing the settings
of one channel will only aect the selected xture.
In the case of the 12PX Hex/12PX Hex Pearl, when in 12 channel mode you should set the starting
DMX address of the rst unit to 1, the second unit to 13 (12 + 1), the third unit to 25 (13 + 12), and so
on. (See chart below for more details.)
Channel Mode
6 channels17 1319
7 channels18 1522
8 channels19 17 25
12 channels1
Unit1
Address
Unit2
Address
1325
Unit3
Address
Unit4
Address
37
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 10
12PX Hex/12PX Hex PearlDMX Traits & Values
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 11
12PX Hex/12PX Hex PearlColor Macro Chart
ColorNo.DMX
VALUE
Color33129-1322552061430
Color34133-1362541771530
Color35137-1402541921380
Color36141-144254165980
Color37145-14825412100
Color38149-1521761700
Color39153-156960110
Color40157-1602341391710
Color41161-1642245970
Color42165-168175771730
Color43169-1721191301990
Color44173-1761471642120
Color45177-1808821630
Color46181-184038860
Color47185-18801422080
Color48189-192521482090
Color49193-1960 46 350
Color50197-20081072220
Color51201-2041071562310
Color52205-2081651982470
Color53209-2120831150
Color54213-2160971660
Color55217-22011001670
Color56221-224040860
Color57225-2282092191820
Color58229-23242165850
Color59233-236255 0 00
Color60237-2400255 00
Color61241-244 0 0 2550
Color62245-248 0 0 0255
Color63249-25200 00
Color64253-255 0 0 00
Color No. DMX
VALUE
OFF0 0 0 0 0
Color1 1-480 255 234 80
Color2 5-880 255 164 80
Color3 9-1277 255 112 77
Color4 13-16117 255 83 83
Color517-20160 255 77 77
Color6 21-24223 255 83 83
Color7 25-28255 243 77 77
Color8 29-32255 200 74 74
Color933-36255 166 77 77
Color10 37-40255 125 74 74
Color11 41-44255 97 77 74
Color12 45-48255 71 77 71
Color13 49-52255 83 134 83
Color14 53-56255 93 182 93
Color15 57-60255 96 236 96
Color16 61-64238 93 255 93
Color17 65-68196 87 255 87
Color18 69-72150 90 255 90
Color19 73-76100 77 255 77
Color20 77-8077 100 255 77
Color21 81-8467 148 255 67
Color22 85-8877 195 255 77
Color23 89-9277 234 255 77
Color24 93-96158 255 144 144
Color25 97-100255 251 153 153
Color26 101-104255 175 147 147
Color27 105-108255 138 186 138
Color28 109-112255 147 251 147
Color29 113-116151 138 255 138
Color30 117-120100 138 255 138
Color31 121-124138 169 255 138
Color32 125-128255 255 255 255
RED GREEN BLUE WHITE
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 12
RGBWA+UV COLOR INTENSITY
AMBER UV
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
12PX Hex/12PX Hex PearlColor Macro Chart
Color No. DMX
VALUE
Color33 129-132255 206 143 0
Color34 133-136254 177 153 0
Color35 137-140254 192 138 0
Color36 141-144254 165 98 0
Color37 145-148254 121 0 0
Color38 149-152176 17 0 0
Color39 153-15696 0 11 0
Color40 157-160234 139 171 0
Color41 161-164224 5 97 0
Color42 165-168175 77 173 0
Color43 169-172119 130 199 0
Color44 173-176147 164 212 0
Color45 177-18088 2 163 0
Color46 181-1840 38 86 0
Color47 185-1880 142 208 0
Color48 189-19252 148 209 0
Color49 193-1960 46 350
Color50 197-2008 107 222 0
Color51 201-204107 156 231 0
Color52 205-208165 198 247 0
Color53 209-2120 83 115 0
Color54 213-2160 97 166 0
Color55 217-2201 100 167 0
Color56 221-2240 40 86 0
Color57 225-228209 219 182 0
Color58 229-23242 165 85 0
Color59 233-236255 0 00
Color60 237-2400 255 00
Color61 241-244 0 0 255 0
Color62 245-248 0 0 0255
Color63 249-2520 0 00
Color64 253-255 0 0 00
RED GREEN BLUE WHITE
RGBWA+UV COLOR INTENSITY
AMBER UV
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
255
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
255
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 13
12PX Hex/12PX Hex PearlSystem Menu
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 14
12PX Hex/12PX Hex Pearl Operating Instructions
CONTROL PANEL LOCK: The control panel will lock itself after 30 seconds of inactivity. To unlock the
control panel, press and hold the Mode button for 3 seconds.
DMX CONTROL MODE:
DMX Address
1. Press the Mode button until one of the following is displayed: A-xxx, CH-xx, dc-xx, Hold, blc, or
soun. These are the various options that are available in DMX Control Mode, and the option that is
displayed is the last setting that was used.
2. Press the Enter button until A-xxx is displayed. xxx represents a 3-digit DMX address of this device.
3. Use the Up and Down buttons to adjust DMX address. Selectable numbers range from 001 to 512.
DMX Channel Mode
1. Press the Mode button until one of the following is displayed: A-xxx, CH-xx, dc-xx, Hold, blc, or
soun. These are the various options that are available in DMX Control Mode, and the option that is
displayed is the last setting that was used.
2. Press the Enter button until CH-xx is displayed. xx is a 2-digit number that represents the DMX
channel mode.
3. Use the Up and Down buttons to select the desired DMX channel mode. Options include 6-channel
mode, 7-channel mode, 8-channel mode, and 12-channel mode.
Dimmer Curve
1. Press the Mode button until one of the following is displayed: A-xxx, CH-xx, dc-xx, Hold, blc, or
soun. These are the various options that are available in DMX Control Mode, and the option that is
displayed is the last setting that was used.
2. Press the Enter button until dc-xx is displayed. xx is a 2-digit number that represents the selected
dimmer curve setting.
3. Use the Up and Down buttons to select the desired dimmer curve setting. Selectable options
include standard (00), stage (01), TV (02), architectural (03), and theatre (04).
DMX Lost
1. Press the Mode button until one of the following is displayed: A-xxx, CH-xx, dc-xx, Hold, blc, or
soun. These are the various options that are available in DMX Control Mode, and the option that is
displayed is the last setting that was used.
2. Press the Enter button until one of the following is displayed: Hold, blc, or soun. These are the available options to set up how the device will behave if the DMX signal is lost.
3. Use the Up and Down buttons to select Hold, blc, or soun.
• Hold: The device will continue to operate according to the last settings that were received before
the DMX connection was lost.
• blc: The device will black out when the DMX connection is lost.
• soun: The device will revert to sound active mode when DMX connection is lost.
SECONDARY MODE:
1. Press the Mode button until Secd is displayed.
2. The device is now in Secondary mode, and its behavior will follow the Primary device.
LED REFRESH RATE MODE:
1. Press the Mode button until F-xx is displayed. xx is a 2-digit number the represents the selected
LED refresh rate.
2. Press the Up and Down buttons to select 7 KHz (00) or 15 KHz (01) as the desired LED refresh rate.
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 15
12PX Hex/12PX Hex Pearl Operating Instructions
MANUAL MODE:
1. Press the Mode button until one of the following is displayed: R-xxx, G-xxx, B-xxx, u-xxx, A-xxx, or
U-xxx. The letter represents the color option that was last selected, and xxx is a 3-digit number that
represents the intensity setting that was last selected.
2. Press the Enter button to cycle through the options listed below:
• R-xxx = Red
• G-xxx = Green
• B-xxx = Blue
• u-xxx = White
• A-xxx = Amber
• U-xxx = UV
3. Press the Up and Down button to select the intensity level of the selected color. Selectable values
range from 000 to 255.
COLOR MACROS MODE:
1. Press the Mode button until C-xx is displayed. xx is a 2-digit number that represents the color
macro that was last selected.
2. Press the Up and Down button to select the desired color macro. Selectable values range from 01 to
64. Please see the Color Macros Chart section of this manual for a detailed list of color macros.
BUILT-IN PROGRAM MODE:
1. Press the Mode button until one of the following is displayed: P-xx, F-xx, or S-xx. The value displayed will depend on the option that was last selected.
2. Press the Enter button until P-xx is displayed. Then use the Up and Down buttons to select the
number of the desired program. Selectable values range from 01 to 07. Please refer to the SystemMenu section of this manual for descriptions of each program.
3. Press the Enter button again until F-xx is displayed. Then use the Up and Down buttons to set the
fade speed of the selected program, with 00 being the fastest setting and 30 being the slowest setting. Please note that fade speed is disabled for programs 02, 04, 06, and 07.
4. Press the Enter button again until S-xx is displayed. Then use the Up and Down buttons to set the
change speed of the selected program, with 01 being the fastest setting and 30 being the slowest
setting. Please note the change speed is disabled for programs 06 and 07.
RF SWITCH:
1. Press the Mode button until RF-xx is displayed. xx will be displayed as either “of” or “on”.
2. Press the Up and Down button to select “of” or “on.”
• “of” disables the ability to control the device via remote control.
• “on” enables the ability to control the device via remote control.
SOUND SENSITIVITY:
1. Press the Mode button until So-xx is displayed. xx is a 2-digit number that represents the sound
sensitivity level that was last selected.
2. Press the Up and Down button to scroll to the desired sound sensitivity level. Selectable values
range from 00 to 30. Select 00 to turn sound sensitivty off.
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 16
12PX Hex/12PX Hex Pearl
Primary-Secondary
Configuration
Primary-Secondary Configuration:
This function will allows you to link units together to run in a Primary-Secondary mode. In
Primary-Secondary operation one unit will act as the controlling unit and the others will react to
the controlling units built-in programs. Any unit can act as a Primary or as a Secondary however,
only one unit can be programmed to act as the “Primary.”
Primary-Secondary Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR data
cables to link your units together. Remember
input and the Female XLR connector is the ouput. The first unit in the chain (primary) will use
the female XLR connector only. The last unit in the chain will use the male XLR connector only.
2. Set the “Primary” unit to your desired mode of operation.
3. Connect the first “Secondary” unit to the “Primary
4. On the “Secondary” unit press the MODE button until “SECd” is displayed. The “Secondary” unit
will now follow the “Primary”.
that the Male XLR connector is the
.”
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 17
12PX Hex/12PX Hex PearlDotz Par RF Operation
The Dotz Par RF remote (sold separately) has many different functions and allows you to control your
fixture from long distance. The remote can control your system up to 25 meters. To use the remote
you must first activate the fixtures receiver, to activate the receiver please see the instructions on
page 17.
BLACKOUT - Pressing this button will blackout the fixture.
FADE - This button will activate the fade program.
COLOR - This button will activate the static color mode. Use the “+” and “-” buttons to scroll through
the colors and find your desired color.
PROGRAMS - This button will activate the built-in programs mode. Use the “+” and “-” buttons to
scroll through the 7 programs and find your desired program.
SOUND ACTIVE - This button activates sound active mode.
AUTO RUN - When in program mode, press this button and use the “+” and “-” buttons to adjust the
speed of the built-in programs. You can also use this button to activate program mode.
“+” and “-” - Use these buttons to adjust the speed of the built-in program, scroll through the built-in
programs, and scroll through the static colors.
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 18
12PX Hex/12PX Hex PearlDimmer Curve Chart
DIMMER
100%
50%
10%
0%
0 Sec
Rise TimeDown Time
Time (ms)
0 sec Fade Time1 sec Fade Time
255255
Dimming Curve
Ramp Effect
00
Rise Time (ms)Down Time (ms)Rise Time (ms)Down Time (ms)
Standard (default)0000
Stage780110015401660
TV1180152018601940
Architectural1380173020402120
Theatre1580194022302280
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 19
12PX Hex/12PX Hex PearlDimensional Drawing
11.7”/297.4mm
9.8”/249mm
5.34”/135.8mm
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 20
12PX Hex/12PX Hex PearlMultiple Unit Power Linking
With this feature you can connect the xtures to one another using the power cable input and
output sockets.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON
THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
12PX Hex/12PX Hex PearlTrouble Shooting
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on
some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the
right connectors; it does matter which way the inputs and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
2. Make sure that Sound Active mode is activated.
12PX Hex/12PX Hex PearlCleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried
out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue,
dust, dew).
ADJ Products, LLC - www.adj.com - 12PX Hex/12PX Hex Pearl User Manual Page 21
12PX Hex/12PX Hex PearlWarranty
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products
to be free of manufacturing defects in material and workmanship for a prescribed period from
the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the
product is purchased within the United States of America, including possessions and
territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#)
before sending back the product–please contact ADJ Products, LLC Service Department
at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All
shipping charges must be pre-paid. If the requested repairs or service (including
parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return
shipping charges only to a designated point within the United States. If the entire instrument is
sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If
any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for
loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any
manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the
product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior
written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because
not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check
up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense
with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this
warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole
discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August
15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products
without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with
products described above. Except to the extent prohibited by applicable law, all implied warranties made
by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness,
are limited in duration to the warranty period set forth above. And no warranties, whether expressed or
implied, including warranties of merchantability or fitness, shall apply to this product after said period
has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is
expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or
damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore
published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
•NonL.E.D.LightingProducts=1-year(365days)LimitedWarranty(Such as: Special Effect
Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par
Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
•LaserProducts=1Year(365Days)LimitedWarranty(excluding laser diodes which have a 6 month
limited warranty)
•L.E.D.Products=2-year(730days)LimitedWarranty(excluding batteries which have a 180 day lim-
Please Note: Specifications and improvements in the design of this unit and this
manual are subject to change without any prior written notice.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance
no guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the device off and on, the
user is encouraged to try to correct the interference by one or more of the following methods:
·Reorient or relocate the device.
·Increase the separation between the device and the receiver.
·Connect the device to an electrical outlet on a circuit different from which the radio receiver is
connected.
·Consult the dealer or an experienced radio/TV technician for help.
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-2650 / Fax: 323-582-2941
www.adj.com / info@americandj.com
A.D.J. Supply Europe B.V.
www.adj.eu / support@adjgroup.eu
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99
ADJ Products, LLC
Junostraat 2
6468 EW Kerkrade
The Netherlands
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.