ADFweb HD67561 User guide

Document
code: MN67561_ENG Revision 1
001
Page
1
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
User Manual
Revision 1.001 English
Gateway ProfiBus Slave to Serial Communication Master
(Order Code: HD67561)
for Website information:
www.adfweb.com?Product=HD67561
for Price information:
www.adfweb.com?Price=HD67561
Benefits and Main Features:
Very easy to configure Low cost
For others Gateways / Bridges:
CANopen to Modbus
See also the following links:
www.adfweb.com?Product=HD67001 (Modbus RTU Master) www.adfweb.com?Product=HD67002 (Modbus RTU Slave) www.adfweb.com?Product=HD67004 (Modbus TCP Master) www.adfweb.com?Product=HD67005 (Modbus TCP Slave)
For others Gateways / Bridges: For CAN bus 2.0A and/or CAN bus 2.0B to Modbus
See also the following links:
www.adfweb.com?Product=HD67011 (Modbus RTU Slave) www.adfweb.com?Product=HD67012 (Modbus RTU Master) www.adfweb.com?Product=HD67014 (Modbus TCP Slave) www.adfweb.com?Product=HD67015 (Modbus TCP Master)
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
Industrial temperature range:
-30°C / 70°C (-22°F / 158°F)
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
2
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
INDEX:
Page UPDATED DOCUMENTATION 2 REVISION LIST 2 WARNING 2 TRADEMARKS 2 INDEX 2 CONNECTION SCHEME 3 CHARACTERISTICS 4 CONFIGURATION 4 USE OF COMPOSITOR SW67561 4 NEW PROJECT / OPEN PROJECT 5 SET COMMUNICATION 6 SET ACCESS 7 GDS FILE 8 UPDATE DEVICE 9 CHARACTERISTICS OF THE CABLES 10 MECHANICAL DIMENSIONS 10 ORDER CODE 11 ACCESSORIES 11 WARRANTIES AND TECHNICAL SUPPORT 12 RETURN POLICY 12 PRODUCTS AND RELATED DOCUMENTS 12
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that you need to check that the following document is:
Updated Related to the product you own
To obtain the most recently updated document, note the “document code” that appears at the top right-hand corner of each page of this document.
With this “Document Code” go to web page www.adfweb.com/download/ and search for the corresponding code on the page. Click on the proper “Document Code” and download the updates.
To obtain the updated documentation for the product that you own, note the “Document Code” (Abbreviated written "Doc. Code" on the label on the product) and download the updated from our web site www.adfweb.com/download/
REVISION LIST:
Revision Date Author Chapter Description
1.000 11/09/2008 Fl All First release version
1.001 13/11/2008 Fl All New software version
WARNING:
ADFweb.com reserves the right to change information in this manual about our product without warning. ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective owners.
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
3
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
CONNECTION SCHEME:
Figure 1: Connection scheme for HD67561
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
4
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
CHARACTERISTICS:
The Configurable ProfiBus Slave to Serial Communication Master Gateway allow the following:
Baud Rate and Parity changeable with software; Mountable on Rail DIN; Power Supply 12/18V AC, 4 VA o 12/24V DC; Temperature range -30°C to 70°C. Serials Protocols supported:
o Simple ASCII Protocol; o Simple Binary Protocol; o Modbus; o JBUS.
CONFIGURATION:
You need Compositor SW67561 software on your PC in order to perform the following:
Define the parameter of the ProfiBus; Define the parameter of the Serial lines; Define the frames to read or write.
USE OF COMPOSITOR SW67561:
To configure the Gateway, use the available software that runs with Windows, called SW67561. It is downloadable on the site www.adfweb.com and its operation is described in this document.
When launching the SW67561 the right window appears (Fig. 2):
Figure 2: Main window for SW67561
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
5
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
NEW PROJECT / OPEN PROJECT:
The “New Project” button creates the folder which contains the entire device configuration. A device configuration can also be imported and exported:
To clone the configurations of a Programmable ProfiBus to Serial Communication Gateway in order to configure another device in the
same manner, it is necessary to maintain the folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to duplicate the project folder with another name
and open the new folder with the button “Open Project”;
When a new project is created or an existent project is open, it will be possible to access the various configuration section of the
software:
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
6
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
SET COMMUNICATION:
This section define the fundamental communication parameter of two Buses, Serial and ProfiBus.
By Pressing the "Set Communication" button from the main wndow for SW67561 (Fig. 2) the window "Set Communication" appears (Fig. 3).
The Window is divided in two section, one for the ProfiBus and the other for the Serial.
The means of the fields for Serial are:
If the field “RS232” is checked, the serial line in use is the RS232, otherwise if field “RS485”
is checked, the serial line in use is the RS485;
In the field “Baud Rate” the baudrate for the serial line is defined; In the field “Parity” the parity of the serial line is defined; In the field “Time Out” there is the maximum time that the device attends for the answer
from the Slave interrogated;
In the field “Cyclic Delay” a delay between two requests is defined; In the subsection “Protocol” it is possible to select the protocol that you wish to use between
the following:
o Modbus RTU; o Modbus ASCII; o JBUS; o Simple Binary Protocol; o Simple ASCII Protocol.
The means of the fields for ProfiBus are:
In the field "ID DEV", the address for the ProfiBus side is defined; In the field "Baud Rate", the baudrate for the ProfiBus is defined; In the field "N Byte IN", the number of byte from the slave ProfiBus to the gateway are
defined;
In the field "N Byte OUT", the number of byte from the gateway to the slave ProfiBus are
defined.
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Figure 3: “Set Communication” window
Document
code: MN67561_ENG Revision 1
001
Page
7
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
SET ACCESS:
By pressing the “Set Access” button from the main window for SW67561 (Fig. 2) the window “Set SDO Access” appears (Fig. 4):
It is divided in two part, the "ProfiBus IN --> Serial Read" and the "Serial Write --> ProfiBus OUT". The first part ("ProfiBus IN --> Serial Read") is used to read the data that arrived from the Slave ProfiBus. The second part ("Serial Write --> ProfiBus OUT") is used to Write the data that will be sent to the Slave ProfiBus.
Profibus IN --> Serial Read
The means of the fields are:
In the field “Address ProfiBus”, the address for the
ProfiBus is defined;
In the field “Slave ID” the address of the Modbus device
you must read is defined;
In the field “Address Register” the start address of the
register to be read is defined;
In the field “Type” insert the data type of the
Register you like read.
o Coil Status; o Input Status; o Holdind Register; o Input Register.
In the field “NPoint” insert the number of
consecutive register to be read;
In the field “Mnemonic” the description for the request
is defined.
Figure 4: “Set SDO Access” window
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
8
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Figure 5: “Address Setting” windo
w
Industrial Electronic Devices
Serial Write --> Profibus OUT
The means of the fields are:
In the field “Address ProfiBus”, the address for the
ProfiBus is defined;
In the field “Slave ID” the address of the Modbus
device you must write is defined;
In the field “Address Register” the start address of the
register to be write is defined;
In the field “NPoint” insert the number of consecutive
register to be write;
In the field “Mnemonic” the description for the request
is defined.
GDS FILE:
By pressing the “GDS File” button is possible to save the GDS file for the ProfiBus side. With this feature you can save the configuration of the gateway of the ProfiBus side.
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
9
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
UPDATE DEVICE:
Section “Update device” (Fig. 6): In order to load the parameters or update the firmware in the gateway, follow these instructions:
Turn off the Device. Connect the Null Modem Cable Form your PC to the
Gateway.
Insert the Boot Jumper (see the Fig. 1 for more info). Select COM port and press the “Connect” Button. Turn on the device. Check The BOOT Led. It must to Blink quickly (see the
Fig. 1 for more info).
Press the “Next” Button Select which operations you want to do. Can select only
Firmware or only Project or both.
Press the “Execute update firmware” to start the upload. When all the operation are “OK” turn off the device. Disconnect the Boot jumper. Disconnect the RS232 Cable. Turn on the Device.
At this point the configuration/firmware on the device is correctly update.
Figure 6: Update Device Serial
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
10
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
CHARACTERISTICS OF THE CABLES:
The connection from RS232 socket to a serial port (example one from a personal computer), must be made with a Null Modem cable (a serial cable where the pins 2 and 3 are crossed). It is recommended that the RS232C Cable not exceed 15 meters.
MECHANICAL DIMENSIONS:
Figure 7: Mechanical dimensions scheme
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
11
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
ORDER CODE:
Order Code: HD67561 - Gateway – ProfiBus Slave to Serial Communication Master
ACCESSORIES:
Order Code: AC34107 - Null Modem Cable Fem/Fem DSub 9 Pin 1,5 m
Order Code: AC34114 - Null Modem Cable Fem/Fem DSub 9 Pin 5 m
Order Code: AC34001 - Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V AC
Order Code: AC34002 - Rail DIN - Power Supply 110V AC 50/60Hz – 12 V AC
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
Document
code: MN67561_ENG Revision 1
001
Page
12
of 12
User Manual
ProfiBus Slave to
Serial Communication
Master
Industrial Electronic Devices
WARRANTIES AND TECHNICAL SUPPORT:
For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com
RETURN POLICY:
If while using your product you have any problem and you wish to exchange or repair it, please do the following:
1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the
request, you need to provide detailed information about the problem.
2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs
If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no longer under warranty, you will receive a repair estimate.
PRODUCTS AND RELATED DOCUMENTS:
HD67121 Gateway CANopen / Canopen www.adfweb.com?product=HD67121
HD67002 Gateway CANopen / Modbus - RTU www.adfweb.com?product=HD67002
HD67004
HD67005
HD67134 Gateway CANopen / DeviceNet www.adfweb.com?product=HD67134
HD67117 CAN bus Repeater www.adfweb.com?product=HD67117
HD67216 CAN bus Analyzer www.adfweb.com?product=HD67216
billed to us will not be accepted).
Part Description URL
Gateway CANopen / Modbus – Ethernet TCP www.adfweb.com?product=HD67004
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31