Page
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
INDEX 2
CONNECTION SCHEME 3
CHARACTERISTICS 4
CONFIGURATION 4
USE OF COMPOSITOR SW67561 4
NEW PROJECT / OPEN PROJECT 5
SET COMMUNICATION 6
SET ACCESS 7
GDS FILE 8
UPDATE DEVICE 9
CHARACTERISTICS OF THE CABLES 10
MECHANICAL DIMENSIONS 10
ORDER CODE 11
ACCESSORIES 11
WARRANTIES AND TECHNICAL SUPPORT 12
RETURN POLICY 12
PRODUCTS AND RELATED DOCUMENTS 12
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that you
need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code” that
appears at the top right-hand corner of each page of this document.
With this “Document Code” go to web page www.adfweb.com/download/ and
search for the corresponding code on the page. Click on the proper “Document
Code” and download the updates.
To obtain the updated documentation for the product that you own, note the
“Document Code” (Abbreviated written "Doc. Code" on the label on the
product) and download the updated from our web site
www.adfweb.com/download/
REVISION LIST:
Revision Date Author Chapter Description
1.000 11/09/2008 Fl All First release version
1.001 13/11/2008 Fl All New software version
WARNING:
ADFweb.com reserves the right to change information in this manual about
our product without warning.
ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective owners.
The Configurable ProfiBus Slave to Serial Communication Master Gateway allow the following:
Baud Rate and Parity changeable with software;
Mountable on Rail DIN;
Power Supply 12/18V AC, 4 VA o 12/24V DC;
Temperature range -30°C to 70°C.
Serials Protocols supported:
o Simple ASCII Protocol;
o Simple Binary Protocol;
o Modbus;
o JBUS.
CONFIGURATION:
You need Compositor SW67561 software on your PC in order to
perform the following:
Define the parameter of the ProfiBus;
Define the parameter of the Serial lines;
Define the frames to read or write.
USE OF COMPOSITOR SW67561:
To configure the Gateway, use the available software that runs
with Windows, called SW67561. It is downloadable on the site
www.adfweb.com and its operation is described in this document.
When launching the SW67561 the right window appears
(Fig. 2):
This section define the fundamental communication parameter of two Buses, Serial and ProfiBus.
By Pressing the "Set Communication" button from the main wndow for SW67561 (Fig. 2) the window
"Set Communication" appears (Fig. 3).
The Window is divided in two section, one for the ProfiBus and the other for the Serial.
The means of the fields for Serial are:
If the field “RS232” is checked, the serial line in use is the RS232, otherwise if field “RS485”
is checked, the serial line in use is the RS485;
In the field “Baud Rate” the baudrate for the serial line is defined;
In the field “Parity” the parity of the serial line is defined;
In the field “Time Out” there is the maximum time that the device attends for the answer
from the Slave interrogated;
In the field “Cyclic Delay” a delay between two requests is defined;
In the subsection “Protocol” it is possible to select the protocol that you wish to use between
the following:
o Modbus RTU;
o Modbus ASCII;
o JBUS;
o Simple Binary Protocol;
o Simple ASCII Protocol.
The means of the fields for ProfiBus are:
In the field "ID DEV", the address for the ProfiBus side is defined;
In the field "Baud Rate", the baudrate for the ProfiBus is defined;
In the field "N Byte IN", the number of byte from the slave ProfiBus to the gateway are
defined;
In the field "N Byte OUT", the number of byte from the gateway to the slave ProfiBus are
By pressing the “Set Access” button from the main window for
SW67561 (Fig. 2) the window “Set SDO Access” appears
(Fig. 4):
It is divided in two part, the "ProfiBus IN --> Serial Read" and
the "Serial Write --> ProfiBus OUT".
The first part ("ProfiBus IN --> Serial Read") is used to read
the data that arrived from the Slave ProfiBus.
The second part ("Serial Write --> ProfiBus OUT") is used to
Write the data that will be sent to the Slave ProfiBus.
Profibus IN --> Serial Read
The means of the fields are:
In the field “Address ProfiBus”, the address for the
ProfiBus is defined;
In the field “Slave ID” the address of the Modbus device
you must read is defined;
In the field “Address Register” the start address of the
register to be read is defined;
In the field “Type” insert the data type of the
Register you like read.
o Coil Status;
o Input Status;
o Holdind Register;
o Input Register.
In the field “NPoint” insert the number of
consecutive register to be read;
In the field “Mnemonic” the description for the request
In the field “Address ProfiBus”, the address for the
ProfiBus is defined;
In the field “Slave ID” the address of the Modbus
device you must write is defined;
In the field “Address Register” the start address of the
register to be write is defined;
In the field “NPoint” insert the number of consecutive
register to be write;
In the field “Mnemonic” the description for the request
is defined.
GDS FILE:
By pressing the “GDS File” button is possible to save the GDS
file for the ProfiBus side.
With this feature you can save the configuration of the gateway
of the ProfiBus side.
Section “Update device” (Fig. 6):
In order to load the parameters or update the firmware in the
gateway, follow these instructions:
Turn off the Device.
Connect the Null Modem Cable Form your PC to the
Gateway.
Insert the Boot Jumper (see the Fig. 1 for more info).
Select COM port and press the “Connect” Button.
Turn on the device.
Check The BOOT Led. It must to Blink quickly (see the
Fig. 1 for more info).
Press the “Next” Button
Select which operations you want to do. Can select only
Firmware or only Project or both.
Press the “Execute update firmware” to start the upload.
When all the operation are “OK” turn off the device.
Disconnect the Boot jumper.
Disconnect the RS232 Cable.
Turn on the Device.
At this point the configuration/firmware on the device is
correctly update.
The connection from RS232 socket to a serial port (example one from a personal computer), must be made with a Null Modem cable (a
serial cable where the pins 2 and 3 are crossed).
It is recommended that the RS232C Cable not exceed 15 meters.
For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at
www.adfweb.com.
Otherwise contact us at the address support@adfweb.com
RETURN POLICY:
If while using your product you have any problem and you wish to exchange or repair it, please do the following:
1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the
request, you need to provide detailed information about the problem.
2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs
If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks.
If the product is no longer under warranty, you will receive a repair estimate.