ADF Web HD67029-B2-232-80, HD67029-B2-232-160, HD67029-B2-485-80, HD67029-B2-485-40, HD67029-B2-485-160 User Manual

...
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 1 of 47
User Manual
Revision 3.000 English
M-Bus Master / Modbus Slave ­Converter
(Order Code: HD67029M-232-20, HD67029-B2-232-40, HD67029-B2-232-80, HD67029-B2-232-160, HD67029-B2-232-250, HD67029M-485-20, HD67029-B2-485-40, HD67029-B2-485-80, HD67029-B2-485-160, HD67029-B2-485-250)
For Website information: www.adfweb.com?Product=HD67029
For Price information: www.adfweb.com?Price=HD67029M-232-20 www.adfweb.com?Price=HD67029-B2-232-40 www.adfweb.com?Price=HD67029-B2-232-80 www.adfweb.com?Price=HD67029-B2-232-160 www.adfweb.com?Price=HD67029-B2-232-250 www.adfweb.com?Price=HD67029M-485-20 www.adfweb.com?Price=HD67029-B2-485-40 www.adfweb.com?Price=HD67029-B2-485-80 www.adfweb.com?Price=HD67029-B2-485-160 www.adfweb.com?Price=HD67029-B2-485-250
Benefits and Main Features:
Very easy to configure
Electrical isolation
Temperature range: -40°C/85°C (-40°F/185°F)
For others M-Bus products see also the following link:
Converter M-Bus Wireless to
www.adfweb.com?Product=HD67083 (Modbus TCP
Slave)
www.adfweb.com?Product=HD67084 (Ethernet)
Converter M-Bus to
www.adfweb.com?Product=HD67021 (RS232) www.adfweb.com?Product=HD67022 (RS485)
Analyzer / Scanner /Sniffer M-Bus
www.adfweb.com?Product=HD67031
Isolator/Repeater M-Bus
www.adfweb.com?Product=HD67032M
Gateway M-Bus / Modbus TCP
www.adfweb.com?Product=HD67044
Gateway M-Bus / PROFIBUS
www.adfweb.com?Product=HD67053M
Gateway M-Bus Concentrator
www.adfweb.com?Product=HD67054M
Gateway M-Bus Slave / Modbus RTU master
www.adfweb.com?Product=HD67059M-232
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
User Manual
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 2 of 47
INDEX:
Page INDEX 2 UPDATED DOCUMENTATION 2 REVISION LIST 2 WARNING 2 TRADEMARKS 2 SECURITY ALERT 3 EXAMPLE OF CONNECTION 4 CONNECTION SCHEME 5 CHARACTERISTICS 9 CONFIGURATION 9 POWER SUPPLY 10 FUNCTION MODES 11 LEDS 12 RS232 14 RS485 15 M-BUS 16 ETHERNET 16 USE OF COMPOSITOR SW67029 17 NEW CONFIGURATION / OPEN CONFIGURATION 18 SOFTWARE OPTIONS 19 SET COMMUNICATION 20 M-BUS 22 MANUFACTURER SPECIFIC DATA 36 UPDATE DEVICE 37 SCAN & DECODE 40 MECHANICAL DIMENSIONS 41 ORDERING INFORMATIONS 43 ACCESSORIES 45 DISCLAIMER 46 OTHER REGULATIONS AND STANDARDS 46 WARRANTIES AND TECHNICAL SUPPORT 47 RETURN POLICY 47
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that you need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code” that appears at the top right-hand corner of each page of this document.
With this “Document Code” go to web page www.adfweb.com/download/ and search for the corresponding code on the page. Click on the proper “Document Code” and download the updates.
REVISION LIST:
WARNING:
ADFweb.com reserves the right to change information in this manual about our product without warning. ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective owners.
Revision Date Author Chapter
Description
2.052 01/02/2012 Fl All Revision
2.053 04/03/2013 Nt All Added new chapters
2.054 12/12/2013 Ff All Revision
3.000 15/12/2017 Ff All New hardware version
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 3 of 47
SECURITY ALERT:
G
ENERAL INFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application. The same applies also when using accessories.
I
NTENDED USE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e. independent limit switches, mechanical interlocks, etc.).
Q
UALIFIED PERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications. Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and who have appropriate qualifications for their job.
R
ESIDUAL RISKS
The device is state-of-the-art and is safe. The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel. These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or death and / or the possibility of damage.
CE
CONFORMITY
The declaration is made by our company. You can send an email to support@adfweb.com or give us a call if you need it.
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 4 of 47
EXAMPLE OF CONNECTION:
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 5 of 47
CONNECTION SCHEME:
Figure
1a
: Connection scheme for HD670
29M-232-20
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 6 of 47
Figure 1b: Connection scheme for HD67029M-485-20
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 7 of 47
Figure
1c
: Connection scheme for HD670
29-B2-232-xxx
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 8 of 47
Figure
1c
: Connection scheme for HD670
29-B2-485-xxx
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 9 of 47
CHARACTERISTICS:
The HD67029 is a M-Bus master to Modbus slave Converter.
It allows the following characteristics:
Electrical isolation between RS232/RS485 - M-Bus – Power Supply; Baud Rate and Parity changeable with software; Mountable on 35mm Rail DIN; Wide power supply input range: 15…21V AC or 18…35V DC;
Wide temperature range: -40°C / 85°C [-40°F / +185°F].
At the Converter can be connected up to 250 standard M-Bus devices. This number depends of the code expressed by the xxx number:
HD67029M-232-20 or HD67029M-485-20 support up to 20 M-Bus devices;
HD67029-B2-232-40 or HD67029-B2-485-40 support up to 40 M-Bus devices; HD67029-B2-232-80 or HD67029-B2-485-80 support up to 80 M-Bus devices; HD67029-B2-232-160 or HD67029-B2-485-160 support up to 160 M-Bus devices;
HD67029-B2-232-250 or HD67029-B2-485-250 support up to 250 M-Bus devices.
In the case of HD67029-B2-xxx-160 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet back-plate. To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air.
In the case of HD67029-B2-xxx-250 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet back-plate. These units have a fan in the top of the enclosure. To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air. Take care to not cover the fan. It is recommended to put the device into a ventilated cabinet.
CONFIGURATION:
You need Compositor SW67029 software on your PC in order to perform the following:
Define the parameter of Modbus and M-Bus line; Define which M-Bus variables are readable on Modbus ;
Update the device.
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 10 of 47
POWER SUPPLY:
The devices can be powered at 15…21V AC and 18…35V DC. The consumption depends to the code of the device. For more details see the two tables below.
VAC
VDC
Vmin Vmax Vmin Vmax
15V 21V 18V 35V
Consumption at 24V DC:
Device No Load [W/VA] Full Load [W/VA]*
HD67029M-xxx-20
3.5
4
HD67029-B2-xxx-40 5
HD67029-B2-xxx-80 8
HD67029-B2-xxx-160 14
HD67029-B2-xxx-250 30
* This value is with all the Slave M-Bus devices of the code (20, 40, 80, 160, 250) connected to the line
HD67029
Warning:
Not reverse the polarity power
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 11 of 47
FUNCTION MODES:
The device has got two functions mode depending of the position of the Dip2 of ‘Dip-Switch A’ of HD67029M-xxx-20 or Dip1 of ‘Dip-Switch A’ of HD67029-B2-xxx-xxx:
The first, with Dip2 of ‘Dip-Switch A’ at OFF position (for HD67029M-xxx-20) or with Dip1 of ‘Dip-Switch A’ at OFF position (for
HD67029-B2-xxx-xxx), is used for the normal working of the device.
The second, with Dip2 of ‘Dip-Switch A’ at ON position (for HD67029M-xxx-20) or with Dip1 of ‘Dip-Switch A’ at ON position (for
HD67029-B2-xxx-xxx), is used for uploading the Project and/or Firmware.
For the operations to follow for the updating, see ‘UPDATE DEVICE’ section.
According to the functioning mode, the LEDs will have specifics functions, see ‘LEDS’ section.
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 12 of 47
LEDS:
HD67029M-
XXX
-20:
The HD67029M-xxx-20 device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below.
LED Normal Mode Boot Mode
1: Device state (green) Blinks slowly (~1Hz) OFF
2: M-Bus state (green) Blinks when a M-Bus response is received OFF
3: Modbus state (green) Blinks when a Modbus request is received OFF
4: Boot Mode (green) OFF Blinks quickly
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 13 of 47
HD67029-B2-
XXX-XXX
:
The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below.
LED Normal Mode Boot Mode
1: Device state (green) Blinks slowly (~1Hz)
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
2: Not used OFF
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
3: M-Bus Comm.
Blinks when a M-Bus response is received
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
4: Modbus comm. (green)
Blinks when a Modbus request is received
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
5: Ethernet Link
ON: Ethernet cable connected
OFF: Ethernet cable disconnected
ON: Ethernet cable connected
OFF: Ethernet cable disconnected
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 14 of 47
RS232:
The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a Null Modem cable (a serial cable where the pins 2 and 3 are crossed). It is recommended that the RS232 cable not exceed 15 meters. The HD67029 is provided with a D-sub connector type DE-9 Male (also called DB-9). The cable must use a DE-9 Female connector. The serial port is used for programming the device (HD67029M-xxx-20) and for Modbus communication.
Industrial Electronic Devices
ADFweb.com S.r.l.
User Manual
M-
Bus master / Modbus slave
- Converter
Document code: MN67029_ENG Revision 3.000 Page 15 of 47
RS485:
To terminate the RS485 line with a 120Ω resistor, it is necessary to put dip 1 ON, like in figure.
The maximum length of the cable should be 1200m (4000 feet).
Here some codes of cables:
Belden: p/n 8132 - 2x 28AWG stranded twisted pairs conductor + foil shield + braid shield; Belden p/n 82842 - 2x 24AWG stranded twisted pairs conductor + foil shield + braid shield; Tasker: p/n C521 - 1x 24AWG twisted pair conductor + foil shield + braid shield; Tasker: p/n C522 - 2x 24AWG twisted pairs conductor + foil shield + braid shield.
Loading...