ADEMCO Q16 User Instruction

SECURITY ALARM
SYSTEM
Q16-ADEMCO
USER INSTRUCTION
1)1,
•••
read
it
FUNCTION
SETTING
Introduction:
This
system
is
wireless
and
wired
alarm
system. compatible
4+2
and
CONTACT
ID
of
Ademco protocol. It
have
a function that the neighbor's
alarm
system will dial for alarm instead
when
the
phone
line
been
cut
down.
The
armIdisarm
function can
be
notice
to
the
alarm
center
freely
by
the ClD phone display etc.
Instructions(Note:
any
function's settings are
based
on
that
the
Alarm
control
panel is
in
a disarmed condition. otherwise, no effective results)
1,
Recorder Personal Messale
Press
the
recorder button
one
time
and
release
it
immediately.
Input
password
four
numbers
(Original password: 1234)
Press
the
recorder button again, there are
two
red
LED
flashing
which
is
to
indicate
you
can start to recorder
your
personal message right
now
within
the
effective distance, 20
CM
away
from
the
Alarm
control panel.
The
recorder
time
is
10
seconds.
When
finished recording
or
recording
over
time,
the
Alarm
control
panel
will send
out a long
sound
to
show
you
are correct
in
this operation. Note:
The
personal message
should
be
precise
and
brief:.
For
example:
This
is xxx home,
xxx
district,
No.
xxx,
The
house is illegally
intruded,
please
assist to handle urgently.
2,
Set Alarm Telephone Numbers
In total you can set 8
phone
No.
in
this model, the first group
and
the second
group
alarm telephone number
is
set
for
contact with the alarm center.,
the
third group
alarm
to
the
sixth group telephone number
is
set
for
manual telephone.
If
the alarm center
haven't receive
the
alarm
info.
the Alarm control
panel
will auto-dial
the
first
two
alarm
telephone
numbers consecutively 5 times (i.ldt'lcrrJ.
d~;;:;w
phone
numbe.
-Press the set button
on
the A
larm
control
pnllClI.
there
is a red
LED
tl~'<;'~~£~~'
:L.;'
you can start to operate
right
now.
Input "1 +*+(telephone
nUlllber)"
Press set button
to
confirm
the
ulftrm
telephone
number.
2
For example: the alarm telephone number
is:
8888888, the setting
route
is:
"set + 1+*+8888888+set"; when finished this, the Alarm control panel
will
send
out
a
long
and
short sound "B" to show your operation
is
correct.
In
the operation, " 1* "
is
mean the first group alarm telephone
number.
And
the setting
route for second group alarm telephone number
is:
"set+2+*+( telephone number)+set ".Repeat the above operation
to
finish setting
the
6
groups alarm telephone numbers. The Alarm control panel
will
auto-dial the
alarm
telephone numbers consecutively according
to
this order when alarm.
If
users
use
an
extension
to
connect the alarm control panel and users should add
one
number before dial out.
For
example, the one number
is
"9". And the alarm telephone
number
is
"8888888",
the
setting route
is
:
"set+ 1+*+9+*+8888888+set". If the extra number
is
"0", then the setting route
is
""set+1+*+0+*+8888888+set"
3,
Change the Password
-Press
the
set
button
on
the
Alarm
control panel, there
is a red
LED
flashing
to
show
you
can
start
to
operate right now.
Input "O+*+(four
numbers)"
Repeat
to
input
the
"four
numbers"
Press"
set"
button
to
confirm.
For
example:
the
password
is: 1234. "
Set+7+*+
1234+ 1234+set"
4,
Set the anti-cut function On/Off
Anti-cut function
On:
Operation on the main panel. input "Program+2+*+0+ program"
Anti-cut function
Off:
Operation
on
the main panel, input "Program +2+*+1+
program" This function have to
be
active ifneed a neighbour instead alarm function
5,
Set keypad Tone On/Off
Keypad tone
on:
"Program+ 3+*+ 1+Program"
Keypad
tone off:
"Program+
3+*+O+Program
6,
Protect Password Function
This
function is used
to
protect
the
password
when
users
use
the
Keypad
of
the
Alarm
control
panel
to
ArmIdisarm
the
Alarm
control
panel.
Cancel this function: "Program+4+*+O+Program"
3
Operate this function: "Program+4+*+ 1 +Program"
7 , Extend the Time ofArm
Users can extend the time
of
Arm when users don't need to arm ·at once
when press the
"Arm" Button. The extend time range is from
0~99
seconds. Route: "Program+5+*+ (numbers)+Program" Example: Users need to Arm in 5 seconds when press the
"Arm" button.
"Program+5+*+ 05+Program"
8,
Extend the Time
of
alarm
Users can extend the time
of
Arm when users
don't
need to arm .at once
when press the
"Arm" Button. The extend time range is from
0~99
seconds. Route: "Program+8+*+ (numbers)+Program" Example: Users need to Arm in 5 seconds when press the
"Arm" button.
"Program+8+*+ 05+Program"
9,
Sounded Time for Siren when alarm
.'
Users can set the sounded time for the siren when alarm.
"Program+6+*+ (time)+ Program" For e.g.: set the sounded time 1 minute for the Siren when alarm; "Program+6+*+ 01+Program". You can set the time form 0-30 Minute, when the setting is more than 30 rninutem the siren will ring until disarm, Set the time "00" is mute alarm.
10,
Remote control the Ringing times
ofthe
Telephone
Users can limit the ringing times
of
the telephone connected to the Alarm
control panel. This is used for remote operation to the Alarm control panel.
"Program+7+*+ (numbers)+Program" Note: set number "0", users
can't
dial the telephone number which is
connect with the Alarm control panel.
11, Learning the Remote controller
&.
Detectors
In order to receive the signal from the Remote controller and detectors, all Alarm control panel should to
learning ID code from Remote controller and
detectors. Route: "Program+9+·+ (password)+ll+(Zone No.)+Program" At
the
same
time,
the
led
light
on
the
main
panel
will
flowing
flash.
Trigger
the
remote
control
or
other
accessories.
the
alarm
control
panel
wi
II
send
out
a'shot
and a long
4
sound
of
"B",
The
zone
number
of
remote
control
must
be
0 1
,other
accessories
can
be
learn
to
any
defense
zone.
12, Cancel Detectors
Cancel detectors ID code: "Program+9+*+ (password)+ 20+Program" All the accessories will been
cancel by this route,
if
want to
resurrecti~n,
please
relearn
the
code.
13, Cancel Remote controller
Cancel Remote controller ID code: "Program+9+*+ (password)+ 1 O+Program" All the remote control will been
cancel by this route,
if
want to
resurrection,
please
relearn
the
code.
14, Separate ArmIDisarm for each separate zone
Route: "Program+9+*+ (password)+90+(Zone No.)+(O
or
l)+Program". 0
means this zone will not alarm when it's Arm,
namely
bypass. 1 means
the
alarm
function
is
on,
bypass
restored.
15, Set the the special phone No. for the
arm
notice
Route: "set +7+*+Phone number+set". the alarm control panel will send out a shot and a long sound
of"B"
to show users' operation is correct.
16, Set the the special phone
No.
for the disarm notice
Route: "set +8+*+Phone number+set". the alarm control panel will send out a shot and a long sound
of"B"
to show users' operation is correct.
17, The ArmIDisarm Notice Function On/OfT
Route: "Program+0+*+10+(0 or l)+Program" . the alarm control panel will
send out a shot and a long sound
of
"B"
to show users' operation is correct.
omeans close, 1 means allow.
18, The ArmIDisarm Phone Display Notice Function On/OfT
Route: "Program+O+*+ 16+(0 or l)+Program" . the alarm control panel will
send out a shot and a long sound
of
"B"
to show users' operation is correct.
omeans close, 1 means allow.
19,
Set ID code
Route: "Set+9+*+lD code (4 No.)+ Neighbor's ID code (4 No.) + Set" . the
5
Loading...