Ademco OPX0, VMSR, OP90, AYXX0, AYQX0 User Manual

AY-x20 Family
Multi-format Proximity Readers
Installation Manual

1. Introduction

The AY-x20 is a family of RFID proximity card readers to be installed for use with access control systems. The AY-x20 family reads the proximity card and transmits its data to the access control system, using common multi-format Wiegand outputs.

1.1 Key Features

Selectable Wiegand 26-Bit, Clock & Data Reads 26-Bit EM or Rosslare format cards Waterproof Green LED control line Red LED control line Buzzer control line Hold control line Optical tamper sensor Tamper output line UV-protected polycarbonate housing

2. Technical Specifications

2.1 Electrical Characteristics

Specification AY-M20 AY-J20 AY-H20 AY-L20 AY-K20 AY-Q20
Power Supply Type
Operating Voltage Range*
Absolute Maximum (non­operating)
Current @ 12V
Read Range**
LED Control Input
Tamper Output
Maximum Cable Distance to Controller
RF Modulation
Bit Rate
* All input voltages should be limited to 1 A maximum. For VAC, the voltage range is peak-to-peak.
** Measured using a Rosslare proximity card or equivalent. Range also depends on electrical environment and proximity to metal.
Open collector, active low, max. sink current 16 mA
Linear type (recommended)
5–16 VDC
18 VDC
Standby: 85 mA
Maximum: 100 mA
10 cm
(3.9 in.)
Dry Contact, N.O.
150 m (500 ft)
ASK, 125 KHz
106 KHz
8 cm
(3.2 in.)
(1.6 in.)
4 cm
Figure 1: AY-x20 Family
AY-M20 AY-H20
AY-L20
AY-J20
AY-K20
AY-Q20

2.2 7BEnvironmental Characteristics

Specification AY-M20 AY-J20 AY-H20 AY-L20 AY-K20 AY-Q20
Operating Temp. Range
Operating Humidity Range
-31°C to 63°C (-25°F to 145°F)
0 to 95% (non-condensing)

2.3 8BPhysical Characteristics

Model Dimensions
(H x W x D)
AY-M20
AY-J20
AY-H20
AY-L20
AY-K20
AY-Q20
88.9 x 88.9 x 15 mm (3.5 x 3.5 x 0.6 in.)
120.0 x 42.0 x 14 mm (4.7 x 1.7 x 0.6 in.)
109.9 x 74.9 x 15 mm (4.3 x 3.0 x 0.6 in.)
144.9 x 42.9 x 20 mm (5.7 x 1.7 x 0.8 in.)
79.9 x 39.9 x 12.8 mm (3.2 x 1.6 x 0.5 in.)
120 x 76 x 20 mm
(4.7 x 3.0 x 0.8 in.)
Weight
109 g
(3.9 oz.)
88.5 g
(3.1 oz.)
100 g
(3.5 oz)
116 g
(4.1 oz)
70.5 g
(2.5 oz)
480 g
(17.0 oz)
1
coded according the

3. Installation

3.1 Installation Kit

The installation kit consists of the following items to be used during the installation procedure:
One mounting template Two pan head screws and wall plugs One L-shaped security screw tool One security screw

3.2 Mounting the AY-x20 Reader

Before mounting, you should determine the best location for the reader.
To mount the reader:
1. Peel off the back of the self-adhesive mounting label template and
place it at the required mounting location.
2. Using the template as a guide, drill two holes (sizes indicated on
the template) used for mounting the reader onto the surface.
3. Insert a suitable wall plug into each hole.
4. Drill a 10-mm (7/16”) hole for the cable. If mounting on metal,
place a grommet or electrical tape around the edge of the hole.
5. Wire the reader to the controller as described in Section 4. A linear
type power supply is recommended.
6. Remove the reader's snap-off front cover to reveal the two screw
holes (see Figure 2 ).
Figure 2: Removing the Top Cover
7. Align the two holes of the reader with those drilled in the wall and
firmly attach the reader to the wall with two screws, whose size is indicated on the template.
8. Relocate the front cover onto the reader.
The reader can also be mounted using strong epoxy glue. After application, the reader should be firmly held in place until the glue dries.
Card readers are to be used with control panels whose power supply is UL Listed Class 2 or equivalent.

4. Wiring

The AY-x20 is supplied with a 10-conductor 18” pigtail.
To connect the reader to the controller:
1. Prepare the reader cable by cutting its jacket back about 3 cm
(1¼") and strip the insulation from the wires about 1.2 cm (½").
2. Prepare the controller cable by cutting its jacket back 3 cm (1¼")
and strip the insulation from the wires about 1.2 cm (½").
3. Splice the reader’s pigtail wires to the corresponding controller
wires (as indicated in Table 1) and cover each joint with insulating tape.
4. If the tamper output is being utilized, connect the purple wire to
the correct input on the controller.
5. Trim and cover all unused conductors.
The individual wires from the reader are color-
Wiegand standard.
When using a separate power supply for the reader, this supply
and that of the controller must have a common ground.
The reader’s cable shield wire should be preferably attached to an
earth ground, or a signal ground connection at the panel, or power supply end of the cable. This configuration is best for shielding the reader cable from external interference.
Table 1: Wiring
Wire Color Wiegand 26-Bit Output
Mode
Red +DC +DC
Black Ground Ground
Green Data 0 Data
White Data 1 Clock
Orange Green LED Green LED
Brown Red LED Red LED
Yellow Buzzer Buzzer
Blue Hold Hold
Purple Tamper Tamper
Grey Open Input Connected to GND
Clock & Data Output Mode
2
Loading...
+ 2 hidden pages