Outdoor air sensor
Remote
control
Equipment interface module (or TrueZONE
panel with wireless adapter)
Installation procedure
Install batteries in wireless devices ................................Page 2
Link devices to wireless network................................Pages 2-3
Mount outdoor sensor ......................................................Page 4
To replace system components if needed, see page 5
3
2
1
HVAC equipment
If there is more than one Equipment Interface Module (EIM) or zone panel:
Wireless devices must be linked separately to each EIM or zone panel.
Installation Guide
Install batteries in wireless devices
1
Make sure batteries are inserted properly (see polarity marks on illustrations below).
Link devices to wireless network
2
Press the
CONNECT
button at the EIM or wireless adapter and wait for green flashing light to begin linking devices to the wireless network (see page 3).
If the light stops flashing before you have linked all devices, press
CONNECT
again.
Press
CONNECT
Remote control Outdoor air sensor
Install 3 fresh AA batteries
Install 2 fresh AA lithium batteries
Flashing status light times out after 15 minutes of inactivity. Press
CONNECT
again if
necessary.
Continued on next page >>
RedLINK™ Installation Guide (Wireless Accessories)
2
If light does not flash, another EIM/wireless adapter may be in wireless setup mode. Exit wireless setup at the other EIM/wireless adapter.
3
Español: vea la página 7 • Français : voir la page 13
Link remote control to wireless network
1 Make sure the Connected light on the
EIM or wireless adapter is flashing (see page 2).
2 Press
CONNECT
at the remote. There will be a short delay as the remote seeks a signal from the wireless network.
3 When the screen displays
“Connected,” press
DONE
.
4 Press NOat the next screen to save and
exit. (Or press
YES
and repeat steps 1-4
to link another EIM/zone panel.)
Link outdoor sensor to wireless network
1 Make sure the Connected light on the
EIM or wireless adapter is flashing (see page 2).
2 Press the
CONNECT
button on the back
of the sensor.
3 Check thermostat to verify that the
outdoor sensor is working. After about 15 seconds, the thermostat should display outdoor temperature and humidity.
(If there is more than one EIM/zone panel, repeat steps 1-3 for each.)
Press and release
If E1 appears, see error codes on page 5.
WIRELESS SETUP
CONNECT
YES NO
CONNECT MORE?
The linking procedure may time out if there is no keypress within 30 minutes. To begin again, press and hold the blank space (or arrow if present) in the lower right corner of the screen until the display changes (about 3 seconds)
Press to link another EIM or zone panel
Press to save and exit
Place sensor securely
in bracket, facing
away from wall
Mount the sensor on a vertical exterior wall, at least 6 inches below any overhang. Choose a location protected from direct sunlight.
Mount outdoor sensor
3
4
RedLINK™ Installation Guide (Wireless Accessories)
To check location before mounting: Restore thermostat Home screen, then hold the sensor where you intend to install it and press the
CONNECT
button. If sensor is working properly, thermostat will switch to display outdoor temperature and humidity.
Press and release
5
Español: vea la página 7 • Français : voir la page 13
Error codes (remote control)
If E1 appears during setup, check error code number: 29 You are attempting to connect a remote control to an incompatible device.
34 Low signal strength. Move remote control to a different location and try again. 38 Make sure Connected light is flashing and you are 2+ feet away from EIM or
wireless adapter.
Replacing system components
Remote control or outdoor sensor
To replace a remote control or outdoor air sensor, install batteries in the new component and follow the procedure on pages 2-3 to link it to the wireless network.
EIM or zone panel
After installing a new EIM or zone panel, you must re-set the remote control to communicate with the new equipment, as described below.
At the remote control:
1 Press and hold
the blank space (or arrow if present) in the lower right
corner of the screen until the display changes (about 3 seconds).
2 Press
REMOVE
, then
YES
to disconnect from old equipment.
3 Follow the procedure on pages 2-3 to link to new equipment.
Press and hold for about 3 seconds
RedLINK™ Installation Guide (Wireless Accessories)
6
Regulatory information
FCC Compliance Statement (Part 15.19) (USA only)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause
undesired operation.
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USA only)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Outdoor sensor
To comply with FCC and Industry Canada RF exposure limits for general population/ uncon­trolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Remote control
This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/uncontrolled exposure.
Industry Canada Statement per Section 4.0 of RSP-100
The term "IC:" before the certification / registration number only signifies that the Industry Canada technical specifications were met.
Section 7.1.5 of RSS-GEN
Operation is subject to the following two conditions: 1 this device may not cause interference, and 2 this device must accept any interference, including interference that may cause undesired
operation of the device.