Ademco 8DLWFZW Users Manual

ADTZWM Wi-Fi® and Z-Wave® Module
grip-020-V0
HONEYWELL
FCC / IC STATEMENT
800-24167 2/18 Rev A
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions: (1) This Device may not cause harmful interfer­ence. (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: CFS8DL-GRIPAIO7 IC: 573F-GRIPAIO7 IC MODEL: GRIPAIO7
CONTAINS MODULE:
CONTAINS MODULE:
SCREW
grip-011-V0
COVER
SCREW
Installation and Setup Guide
General Information
The Communication Modules allow the control panel to communicate with the Central Station via the cellular radio network. The module connects directly to the control panel and is powered via the control panel’s connection.
Compatible Controls:
ADT7AIO/ADT5AIO Series - Installation Guide P/N 800-24121 or higher. ADTHYBWL Series - Installation Guide P/N 800-24125 or higher.
ADT2X16AIO Series – Installation Guide P/N 800-24341 or higher.
Installing the Module in the ADT7AIO/ADT5AIO or ADT2X16AIO Series
1. Affix the provided FCC/IC label (P/N 800­24286 on the control’s case back (refer to Figure 1).
connection as well as
2. Remove the screw securing the rear case to the front case.
3. Slide the rear case down and separate from the front case.
4. Remove the communication module access cover.
5. Insert the ADTZWM into the slot on the left side of the control as shown in Figure 2 and ensure the receptacle is securely seated on the control’s edge connector.
6. Secure the module with the provided screw.
7. Re-install the communication module access cover.
8. Install the rear case and secure with the screw.
FCC ID: CFS8DLWFZW
IC:573F-WFZW
FCC ID: CFS8DLWFZW
IC:573F-WFZW
Figure 1. FCC/IC Label Location (ADT7AIO Shown)
Figure 2. Installing the ADTZWM Module (ADT7AIO Shown)
Installing the Module in the ADTHYBWL Series
BATT+ BATT -
AUX/BELL_OC LED RUN LED IB2/ACTIVE LED RESERVED LED
TRIGGER 2
12V
GND
TRIGGER 1
BATTERY POWER LED
NOT USED
HI
LO
ZONE 2
2000 OHMS EOLR
ZONE 1
USE FOR 2-WIRE SMOKE DETECTORS
MAXIMUM NUMBER OF 2-WIRE SMOKE DETECTORS
ON ZONE 1
IS 16
ZONE 1
2000 OHMS EOLR
HI
HI
LO
LO
HI
LO
2000 OHMS EOLR
ZONE 3
2000 OHMS EOLR
ZONE 4
HI
HI
LO
LO
2000 OHMS EOLR
ZONE 5
2000 OHMS EOLR
ZONE 6
HI
HI
LO
LO
2000 OHMS EOLR
ZONE 7
2000 OHMS EOLR
ZONE 8
EARTH GROUND
300-10211
13.5 VDC, 1.8A POWER SUPPLY TO 10VAC UNSWITCHED OUTLET (24HR)
DC+
DC -
DC+
DC -
ADTHYBWL-Series - Summary of Connections
800-24129 2/18 Rev.A
RJ-45
CONNECTOR
TAMPER SWITCH
BLACK
RED
RECHARGEABLE BATTERY
(12V
, 7AH)
SEALED LEAD ACID TYPE
SEE INSTRUCTIONS** FOR PROPER GROUNDING
TO INTERNET C
ONNECTION
© 2018 ADT Security Services
GND
AUX
SLOT 3
GENERAL
SLOT 2
WiFi / ZWAVE
SLOT 1
LTE
8-PIN TRIGGER C
ONNECTOR
AC POWER LED
TRIGGER OUTPUT 1: 100mA MAX TRIGGER OUTPUT 2: 100mA MAX
AUX OUTPUT LED
NOT
USED
24-HR BATTERY STANDBY REQUIRED FOR FIRE INSTALLATIONS. USE 12V, 7AH BATTERY FOR 120mA AUX POWER. SEE INSTRUCTIONS.
BATTERY CAPACITY FOR EMERGENCY BURGLARY STANDBY USE AT LEAST 4 HRS.
CHARGING VOLTAGE 13.8VDC. MAXIMUM CHARGING CURRENT 650mA.
SEALED LEAD-ACID TYPE. BATTERY NORMALLY NEED NOT BE REPLACED FOR AT LEAST THREE YEARS
TO DETERMINE TOTAL STANDBY LOAD ON BATTERY, ADD 100mA TO TOTAL OF AUX. POWER AND REMOTE TOUCHPAD CURRENTS
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. IN ADDITION, THIS S
YSTEM MUST BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.
BLACK: TOUCHPAD GND (-) RETURN
YELLOW: TOUCHPAD IB2A
GREEN: TOUCHPAD IB2B
RED: TOUCHPAD POWER (+)
AUX. PWR
OUTPUT
10.5-13.8VDC 200mA MAX. (120mA MAX.
FOR UL
INSTALLATIONS)
ALL OUTPUTS
ARE POWER LIMITED.
}
CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEAD­QUARTERS OR CENTRAL STATION SHALL BE PERMIT­TED ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAVING JURIDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE EMERGENCY NUMBER
THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARD 72 (NATIONAL FIRE PROTECTION ASSOCIATION, BATTERYMARCH PARK, QUINCY, MA 02169). PRINTED INFORMATION DESCRIBING INSTALLATION, TESTING, MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT.
820 OHMS EOLR
ALARM
OUTPUT
10.5–13.8VDC, 2A MAX. (600mA MAX. FOR UL
USAGE, INCLUDING
AUX POWER) STEADY FOR
BURGLARY/PANIC, TEMPORAL PULSE SOUNDING FOR FIRE. USE 702 SIREN, OR
12V BELL. SEE INSTRUCTIONS.
FOR BELL SUPERVISION, AND CONNECT RESISTOR DIRECTLY ACROSS EXTERNAL SOUNDER.
WTP100
TOUCHPAD
1501 Yamato Road Boca Raton, Florida 33431
ALARM STATUS
CANCEL
PANIC
OFF
CODECHI MEINSTANT
READY
TESTBYPASSMAX
STAYAWAY
2
31
5 64
8 97
0 #
TROUBLE
** FOR COMPLETE INFORMATION SEE INSTRUCTIONS 800-24126 OR HIGHER
- +
A
B
MAX. ZONE RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)
(USE EOLR PART NUMBER P4100 PART OF KIT SAHDWR1)
ASSEMBLED IN MEXICO
ETL Listed Household Fire and Burglar Warning Unit
800-21465 10/15 Rev.A
3091091
Conforms to UL STD 985, 1023, 1635 Classified to ANSI/SIA CP01-2010
Model LCP500-L
800-24232 3/18 Rev A
HONEYWELL GRIP HYBRID CONTROLLER
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions: (1)This Device may not cause harmful interference. (2)This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: CFS8DL-GRIPH IC: 573F-GRIPH HVIN: GRIPH
For Patent Information see: www.honeywell.com/patents Country of Origin: Mexico
grip-028-V0
CONTAINS MODULE:
GENERA
L
WiFi
BATT+ GND
LTE
TX
RXGND
TX
RXGND
grip-012-V0
EXT INT
SCREW
ADTZWM MODULE
1. Affix the provided FCC/IC label (ADTZWM, P/N 800-24286) on the ADTHYBWL cabinet (refer to Figure 3)
CONTAINS MODULE:
2. Install the ADTZWM (ZWAVE) on the
edge connector on the PCB (refer to Figure 4). Ensure the receptacle is securely seated on the edge connector.
3. Secure the module with the provided
screw.
FCC ID: CFS8DLWFZW
IC:573F-WFZW
FCC ID: CFS8DLWFZW
IC:573F-WFZW
Figure 3. FCC/IC Label Location
Figure 4. Installing the ADTZWM Module
Programming
1. The ADTZWM requires a router and internet service for Wi-Fi connection.
2. Programming associated with the ADTZWM module is accomplished via the MobileTech app, as part of the control panel programming. Refer to the control panel installation and setup guide for additional information.
Loading...