BATT+ BATT -
AUX/BELL_OC LED
RUN LED
IB2/ACTIVE LED
RESERVED LED
TRIGGER 2
12V
GND
TRIGGER 1
BATTERY POWER LED
NOT
USED
HI
LO
ZONE 2
2000
OHMS
EOLR
ZONE 1
USE FOR
2-WIRE SMOKE
DETECTORS
MAXIMUM
NUMBER OF
2-WIRE SMOKE
DETECTORS
ON ZONE 1
IS 16
ZONE 1
2000
OHMS
EOLR
HI
HI
LO
LO
HI
LO
2000
OHMS
EOLR
ZONE 3
2000
OHMS
EOLR
ZONE 4
HI
HI
LO
LO
2000
OHMS
EOLR
ZONE 5
2000
OHMS
EOLR
ZONE 6
HI
HI
LO
LO
2000
OHMS
EOLR
ZONE 7
2000
OHMS
EOLR
ZONE 8
EARTH
GROUND
300-10211
13.5 VDC, 1.8A
POWER
SUPPLY TO
10VAC
UNSWITCHED
OUTLET
(24HR)
DC+
DC -
DC+
DC -
ADTHYBWL-Series - Summary of Connections
800-24129 2/18 Rev.A
RJ-45
CONNECTOR
TAMPER
SWITCH
BLACK
RED
RECHARGEABLE BATTERY
(12V
, 7AH)
SEALED LEAD ACID TYPE
SEE
INSTRUCTIONS**
FOR PROPER
GROUNDING
TO INTERNET
C
ONNECTION
© 2018 ADT Security Services
GND
AUX
SLOT 3
GENERAL
SLOT 2
WiFi / ZWAVE
SLOT 1
LTE
8-PIN TRIGGER
C
ONNECTOR
AC POWER LED
TRIGGER OUTPUT 1: 100mA MAX
TRIGGER OUTPUT 2: 100mA MAX
AUX OUTPUT LED
NOT
USED
24-HR BATTERY
STANDBY REQUIRED
FOR FIRE
INSTALLATIONS.
USE 12V, 7AH
BATTERY FOR
120mA AUX POWER.
SEE INSTRUCTIONS.
BATTERY CAPACITY FOR EMERGENCY
BURGLARY STANDBY USE AT LEAST
4 HRS.
CHARGING VOLTAGE 13.8VDC.
MAXIMUM CHARGING CURRENT
650mA.
SEALED LEAD-ACID TYPE. BATTERY
NORMALLY NEED NOT BE REPLACED
FOR AT LEAST THREE YEARS
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER AND REMOTE TOUCHPAD
CURRENTS
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. IN ADDITION, THIS
S
YSTEM MUST BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.
BLACK: TOUCHPAD GND (-) RETURN
YELLOW: TOUCHPAD IB2A
GREEN: TOUCHPAD IB2B
RED: TOUCHPAD POWER (+)
AUX. PWR
OUTPUT
10.5-13.8VDC
200mA MAX.
(120mA MAX.
FOR UL
INSTALLATIONS)
ALL OUTPUTS
ARE POWER
LIMITED.
}
CONNECTION OF
THE FIRE ALARM
SIGNAL TO A FIRE
ALARM HEADQUARTERS OR
CENTRAL STATION
SHALL BE PERMITTED ONLY WITH
THE PERMISSION
OF THE LOCAL
AUTHORITY HAVING
JURIDICTION. THE
BURGLAR ALARM
SIGNAL SHALL NOT
BE CONNECTED
TO A POLICE
EMERGENCY
NUMBER
THIS EQUIPMENT
SHOULD BE
INSTALLED
IN ACCORDANCE
WITH THE NATIONAL
FIRE PROTECTION
ASSOCIATION'S
STANDARD 72
(NATIONAL FIRE
PROTECTION
ASSOCIATION,
BATTERYMARCH
PARK, QUINCY,
MA 02169). PRINTED
INFORMATION
DESCRIBING
INSTALLATION,
TESTING,
MAINTENANCE,
EVACUATION
PLANNING AND
REPAIR SERVICE IS
TO BE PROVIDED
WITH THIS
EQUIPMENT.
820 OHMS
EOLR
ALARM
OUTPUT
10.5–13.8VDC,
2A MAX. (600mA
MAX. FOR UL
USAGE, INCLUDING
AUX POWER)
STEADY FOR
BURGLARY/PANIC,
TEMPORAL PULSE
SOUNDING FOR FIRE.
USE 702 SIREN, OR
12V BELL. SEE
INSTRUCTIONS.
FOR BELL
SUPERVISION, AND
CONNECT RESISTOR
DIRECTLY ACROSS
EXTERNAL SOUNDER.
WTP100
TOUCHPAD
1501 Yamato Road
Boca Raton, Florida 33431
ALARM STATUS
CANCEL
PANIC
OFF
CODECHI MEINSTANT
READY
TESTBYPASSMAX
STAYAWAY
2
31
5 64
8 97
0 #
TROUBLE
** FOR COMPLETE INFORMATION SEE INSTRUCTIONS 800-24126 OR HIGHER
- +
A
B
MAX. ZONE RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)
(USE EOLR PART NUMBER P4100 PART OF KIT SAHDWR1)
ASSEMBLED IN MEXICO
ETL Listed
Household Fire
and Burglar
Warning Unit
800-21465 10/15 Rev.A
3091091
Conforms to UL STD 985, 1023, 1635
Classified to ANSI/SIA CP01-2010
Model LCP500-L
800-24232 3/18 Rev A
HONEYWELL GRIP HYBRID CONTROLLER
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions:
(1)This Device may not cause harmful interference.
(2)This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: CFS8DL-GRIPH
IC: 573F-GRIPH
HVIN: GRIPH
For Patent Information see: www.honeywell.com/patents
Country of Origin: Mexico
grip-028-V0
1. Affix the provided FCC/IC label
(ADTZWM, P/N 800-24286) on the
ADTHYBWL cabinet (refer to Figure 3)
2. Install the ADTZWM (ZWAVE) on the
edge connector on the PCB (refer to
Figure 4). Ensure the receptacle is
securely seated on the edge connector.
3. Secure the module with the provided
screw.
Figure 3. FCC/IC Label Location
Figure 4. Installing the ADTZWM Module
1. The ADTZWM requires a router and internet service for Wi-Fi connection.
2. Programming associated with the ADTZWM module is accomplished via the MobileTech app, as part of the control panel
programming. Refer to the control panel installation and setup guide for additional information.