TSSC Installation and Setup Guide
SEE LAST PAGE FOR AGENCY STATEMENTS
STEP 1 - Installing the Base Rechargeable Backup Battery
and Power Connector
1. Remove the Base Case Back.
2. Connect the battery connector to the receptacle on the PC board.
3. Insert the Battery Pack into the case.
4. Secure the Battery Pack with the Battery Retainer using the Retaining Screw.
5. Connect the power pack into the power receptacle, looping the power cord as
shown in Detail A.
NOTE: If using the optional wall mount configuration, skip to the Base wall
mounting procedure. If not, complete step 6.
6. Secure the Case Back onto the Base.
NOTE: Do not apply power at this time.
STEP 3 - Keypad Mounting
The keypad is designed to be placed on a desk/table top with the stand attached.
An optional mounting plate can be used to mount the keypad to the wall.
Power Connections
Connect the Power Supply Cable into its connector as shown below and route it
from the bottom of the keypad.
IMPORTANT: Do not apply power to the keypad at this time.
Installing Keypad To Desk-Top Stand
1. Place the Keypad face down on a level surface.
2. Connect the battery connector to the receptacle on the PC board.
3. Insert the Battery Pack into the case.
4. Secure the Battery Pack with the Battery Retainer using the Retaining Screw.
5. Install tabs on Desk Stand into appropriate slots as shown and secure with
two screws
6. Plug in the power pack to the receptacle.
Mounting the Base to a Wall (Optional)
To mount the Base to a wall, perform to the following:
IMPORTANT: Record the ACTIVATION KEY number, MAC Address, CRC
number and WPA2 number located on case back prior to wall mounting.
1. Complete steps 1 through 5 of the Installing the Base Rechargeable Backup
Battery and Power Connector paragraph
2. Secure the Mounting Plate to the wall and secure with 4 screws.
3. Install the Tamper Screw as shown.
4. Secure the Base to the Mounting Plate by aligning the slots on the Base and
sliding the unit down until locked in position.
STEP 2 - Setting up the Communication Links
Prior to power up of the Base (when directed in the TSSC Installer App), the
Ethernet communications link must be connected to the residence’s router. The
connection is from an Ethernet port on the router to the “BROADBAND” port on
the Base.
IMPORTANT! Under no circumstances should the “DEVICE LAN” port ever be
connected to the residence’s router.
Ê800-13956V1oŠ
800-13956V1 11/13 Rev. C
STEP 4 - Base Registration & Accessing the Installer App
Run TSSC Installer App:
Go to https://portal.adtpulse.com/activation/access/signin.jsp and follow the
prompts.
Power the Base Unit
When directed in the TSSC Installer App, plug the power pack into the wall
receptacle to power the Base. During the first 45 seconds of power initialization,
TSSC lights up the CELLULAR, NETWORK and STATUS LEDs one by one
slowly in sequence. After the first 45 seconds, the LEDs chase in a rapid sequence
for approximately 30 more seconds. The POWER LED is always ON while
initialization is being executed. When the LEDs stop chasing and the POWER
LED is lit green, the Base is powered up and ready for the registration process to
begin.
NOTES: • The BATTERY LED will blink until the battery is fully charged.
• The NETWORK LED will remain amber until activated.
IMPORTANT: Once the programming procedure has started and the unit
is powered up, do not remove power or disconnect the battery, nor open
the case. Disconnecting power or activating the tamper switch can cause
unpredictable programming results.
POWER DOWN CAUTION: To power down the system, do the following:
1. Clear the alarm memory.
2. Enter “MASTER CODE + [#] + [∗] + 9” at the TSSC Base unit, then wait until
the four LEDs to the right of the Power LED turn off before removing power.
IMPORTANT: Shutting down the Base unit will cancel the sending of any
reports to the central station that may be in progress.
Radio Activation
Go to https://3ps.adt.com and follow the prompts.
Testing the System
There are three test modes as follows:
Walk Test: user code + 5 + 1 (tests the sensors in the system; see User Guide for
details)
Comm Test: user code + 5 + 2 (tests the communication link)
NTP Server Test: user code + 5 + 3 (causes the panel to contact the NTP server to
verify that the communication link to the NTP server is valid)
Specifications
Base Unit:
Dimensions: .........................8.5” W x 6” H x 1.875” D
Voltage Input: ....................P/N 300-05763V1: 110 VAC input/9 VDC output 2.5A,
2-prong
24-Hour Backup Battery: ..P/N 300-03866: Rechargeable Backup Battery: Nickel-
metal hydride battery pack rated at 7.2 Vdc, 3700mA
Communication:
Formats Supported: ...........4-Digit Contact ID
Keypad:
Dimensions: .........................6.69” W x 5.36” H x 0.875” D
Voltage Input: ....................P/N 300-05763V1: 110 VAC input/9 VDC output 2.5A,
2-prong
24-Hour Backup Battery: ..P/N 300-06868: Rechargeable Backup Battery: 7.2V,
6xAAA, 6x600mAH, NiMH
Home Health Care Applications
IMPORTANT: In Home Health Care applications [UL1637] you must use
THE LIMITATIONS OF THIS ALARM SYSTEM
Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other
powered solely by AC will not work if their AC power supply is cut off for any reason,
matches, or arson. Depending upon the nature of the fire and/or the locations of the
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges
sleepers if they are located on the other side of closed or partly open doors. If warning
station may be out of service or temporarily out of service. Telephone lines are also
to themselves and their loved ones to learn about these developments.
Recommendations For Proper Protection
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
y compris les interférences causant une réception indésirable.
This Control Complies With NFPA Requirements For Temporal Pulse
connected to an alarm monitoring station).
pendant model 5802WXT or 5802WXT-2. The maximum range is 50 ft.
Contacting Technical Support
PLEASE, before you call Technical Support, be sure you:
READ THE INSTRUCTIONS!
• Determine that the power supply and/or backup battery are supplying
proper voltages.
• Verify your programming information where applicable.
• Note the proper model number of this product, and the version level (if
known) along with any documentation that came with the product.
• Note your ADT customer number and/or company name.
Having this information handy will make it easier for us to serve you quickly and
effectively.
Technical Support: Contact your ADT Customer Care Representative.
While this system is an advanced design security system, it does not offer guaranteed
protection against burglary or fire or other emergency. Any alarm system, whether
commercial or residential, is subject to compromise or failure to warn for a variety of
reasons. For example:
• Intruders may gain access through unprotected openings or h
sophistication to bypass an alarm sensor or disconnect an alarm warning device.
•
sensing devices will not work without power. Battery-operated devices will not work
without batteries, with dead batteries, or if the batteries are not put in properly. Devices
however briefly.
• Signals sent by wireless transmitters may be blocked or reflected by metal before they
reach the alarm receiver. Even if the signal path has been recently checked during a
weekly test, blockage can occur if a metal object is moved into the path.
• A user may not be able to reach a panic or emergency button quickly enough.
• While smoke detectors have played a key role in reducing residential fire deaths in the
United States, they may not activate or provide early warning for a variety of reasons in
as many as 35% of all fires, according to data published by the Federal Emergency
M
anagement Agency. Some of the reasons smoke detectors used in conjunction with this
System may not work are as follows. Smoke detectors may have been improperly installed
and positioned. Smoke detectors may not sense fires that start where smoke cannot reach
the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors.
Smoke detectors also may not sense a fire on another level of a residence or building. A
second-floor detector, for example, may not sense a first-floor or basement fire. Moreover,
smoke detectors have sensing limitations. No smoke detector can sense every kind of fire
every time. In general, detectors may not always warn about fires caused by carelessness
and safety hazards like smoking in bed, violent explosions, escaping gas, improper
storage of flammable materials, overloaded electrical circuits, children playing with
smoke detectors, the detector, even if it operates as anticipated, may not provide
sufficient warning to allow all occupants to escape in time to prevent injury or death
•
as diagrammed in their installation manual. Passive Infrared Detectors do not provide
volumetric area protection. They do create multiple beams of protection, and intrusion
can only be detected in unobstructed areas covered by those beams. They cannot detect
motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass
partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying
of any material on the mirrors, windows or any part of the optical system can reduce their
detection ability. Passive Infrared Detectors sense changes in temperature; however, as
the ambient temperature of protected area approaches the temperature range of 90° to
105°F, the detection performance can decrease.
• Alarm warning devices such as sirens, bells, or horns may not alert people or wake up
devices sound on a different level of the residence from the bedrooms, then they are less
likely to waken or alert people inside the bedrooms. Even persons who are awake may not
hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other
appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not
warn hearing-impaired people or waken deep sleepers.
• Telephone lines needed to transmit alarm signals from a premises to a central monitorin
subject to compromise by sophisticated intruders.
• Even if the system responds to the emergency as intended, however, occupants may have
insufficient time to protect themselves from the emergency situation. In the case of a
monitored alarm system, authorities may not respond appropriately.
• This equipment, like other electrical devices, is subject to component failure. Even though
this equipment is designed to last as long as 10 years, the electronic components could
fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire occurs
is inadequate maintenance. This alarm system should be tested weekly to make sure all
sensors and transmitters are working properly.
Installing an alarm system may make one eligible for lower insurance rates, but an alarm
system is not a substitute for insurance. Homeowners, property owners, and renters should
continue to act prudently in protecting themselves and continue to insure their lives and
property.
We continue to develop new and improved protection devices. Users of alarm systems owe it
The Following Recommendations for the Location of Fire and Burglary Detection Devices
Help Provide Proper Coverage for the Protected Premises.
Recommendations for Smoke and Heat Detectors
With regard to the number and placement of smoke/heat detectors, we subscribe to the
recommendations contained in the National Fire Protection Association's (NFPA)
Standard #72 noted below.
Early warning fire detection is best achieved by the installation of fire detection
equipment in all rooms and areas of the household as follows: For minimum protection a
smoke detector should be installed outside of each separate sleeping area, and on each
additional floor of a multi-floor family living unit, including basements. The installation of
smoke detectors
recommended.
For additional protection the NFPA recommends that you install heat
in the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room,
utility and storage rooms, basements and attached garages.
In addition, we recommend the following:
• Install a smoke detector inside every bedroom where a smoker sleeps.
• Install a smoke detector inside every bedroom where someone sleeps with the door
partly or completely closed. Smoke could be blocked by the closed door. Also, an alarm
in the hallway outside may not wake up the sleeper if the door is closed.
• Install a smoke detector inside bedrooms where electrical appliances (such as
portable heaters, air conditioners or humidifiers) are used.
• Install smoke detectors at both ends if the hallway is more than 40 feet (12 meters
l
ong.
• Install smoke detectors in any room where an alarm control is located, or in any room
where alarm control connections to an AC source or phone lines are made. If detectors
are not so located, a fire within the room could prevent the control from reporting a
The user shall not make any changes or modifications to the equipment unless authorized
by the Installation Instructions or User's Manual. Unauthorized changes or modifications
could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for
use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used
properly, that is, in strict accordance with the manufacturer's instructions, may cause
interference to radio and television reception. It has been type tested and found to comply
with the limits for a Class B computing device in accordance with the specifications in Part
15 of FCC Rules, which are designed to provide reasonable protection against such
interference in a residential installation. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause interference to
radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• I
f using an indoor antenna, have a quality outdoor antenna installed.
eorient the receiving antenna until interference is reduced or eliminated.
• R
• M
ove the radio or television receiver away from the receiver/control.
ove the antenna leads away from any wire runs to the receiver/control.
• M
• P
lug the receiver/control into a different outlet so that it and the radio or television
receiver are on different branch circuits.
• C
onsult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
T
his Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries
Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit
pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue
in kitchens, attics (finished or unfinished), or in garages is not normally
or smoke detectors
)
Warning – The antenna(s) used for this device must be installed to provide a
g
separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter except in
accordance with FCC multi-transmitter product procedures.
Mise en Garde
Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit
être installée à une distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les
Sounding Of Fire Notification Appliances
Recommendations for Proper Intrusion Protection
For proper intrusion coverage, sensors should be located at every possible point of entry to
a home or premises. This would include any skylights that may be present, and the upper
windows in a multi-level building.
In addition, we recommend that radio backup be used in a security system. This will
ensure that alarm signals can be sent to the alarm monitoring station in the event that the
telephone lines are out of order (alarm signals are normally sent over the phone lines, if