The LCT500 is a wireless door / window
Open the LCT500
Mounting
Note
BETA DRAFT II’s – 05/27/15
PLEASE GO TO THE BOTTOM OF THE NEXT PAGE FOR FCC/IC AGENCY STATEMENTS
contact intended for use with Honeywell controls that support SiX™ series devices.
Firmly slide the top and bottom housings in opposite directions and pull them apart to open the device.
The LCT500 can be mounted with several options:
Installation with magnet: Make gap is
0.75"; Break gap is 1.30".
Optional Wiring for Service loops: a) surface wiring b) concealed wiring Note: Wiring limit is 3ft.
Range: TBD
: After enrolling and before mounting the LCT500 permanently, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary.
Enroll and Set Up
Note:
Note
Battery Replacement
BATTERY CAUTION
away from children.
*Note: Depending on the signal
The LCT500 can be enrolled and
programmed before or after installation.
1. Set the Lyric Smart Controller in
Programming Mode and go to Zone Programming. Select Add New, then Serial Number. Follow the control’s instructions to begin enrollment.
2. Pull the battery tab to activate the LCT500
and begin the enrollment process.
3. The LED flashes (about 20 seconds*) during
enrollment.
The device sends the device MAC ID address and Services information to the control.
The control registers the device and displays the transmitter data on screen.
4. When done, the LED is ON for 3 seconds and the control beeps to confirm enrollment.
5. If the device is not successfully enrolled during the enrollment period, the LED turns off and the device powers down. Activate a tamper, wired service (loop) or the reed switch to restart the enrollment process.
: Once enrolled in a system, the LCT500 cannot be used with another controller until it is removed from the current controller. See the Controller’s instructions for details.
Follow instructions in the Controller’s programming guide to program the LCT500 services:
Cover and Wall tamper switches
Reed switch / Magnet
External device connected / Terminal block
(unsupervised)
Temperature sensor (this service is set by the panel)
Push the bottom latch of the mounting bracket back to disengage it. Then slide the back housing, up and out to remove it from the mounting bracket.
Slide the front and back housings in opposite directions and pull the housings apart.
Remove the battery, wait 10 seconds, then insert a new battery. Recommended batteries: Panasonic CR123A Honeywell 466 Duracell DL123 Duracell DL123A
Place the front and back housings together and slide them together as shown.
Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep
: Risk of fire, explosion and burns.
strength between the device and the control, the enrollment period may take longer than 20 seconds.