PLEASE GO TO PAGE 68 FOR THE FCC / IC
INFORMATION / STATMENTS
OR USE THE BOOKMARK
APX32EN
Security Systems
Installation and Setup Guide
PREK14114-8 11/07 Rev. A
RECOMMENDATIONS FOR PROPER PROTECTION
The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper
Coverage for the Protected Premises.
Recommendations for Smoke and Heat Detectors
With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in
the National Fire Protection Association's (NFPA) Standard #72 noted below.
• Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of
the household as follows: For minimum protection a smoke detector should be installed outside of each separate sleeping
area, and on each additional floor of a multi-floor family living unit, including basements. The installation of smoke
detectors in kitchens, attics (finished or unfinished), or in garages is not normally recommended.
• For additional protection the NFPA recommends that you install heat
room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, basements and attached garages.
In addition, we recommend the following:
• Install a smoke detector inside every bedroom where a smoker sleeps.
• Install a smoke detector inside every bedroom where someone sleeps with the door partly or completely closed. Smoke
could be blocked by the closed door. Also, an alarm in the hallway outside may not wake up the sleeper if the door is
closed.
• Install a smoke detector inside bedrooms where electrical appliances (such as portable heaters, air conditioners or
humidifiers) are used.
• Install a smoke detector at both ends of a hallway if the hallway is more than 40 feet (12 meters) long.
• Install smoke detectors in any room where an alarm control is located, or in any room where alarm control connections
to an AC source or phone lines are made. If detectors are not so located, a fire within the room could prevent the control
from reporting a fire or an intrusion.
THIS CONTROL COMPLIES WITH NFPA REQUIREMENTS FOR TEMPORAL PULSE SOUNDING OF FIRE
NOTIFICATION APPLIANCES.
or smoke detectors in the living room, dining
DINING
LIVING ROOM
LIVING
ROOM
BASEMENT
KITCHEN
BEDROOM
TO
BEDROOM
BEDROOMBEDROOM
KTCHN
BEDROOMBEDROOM
BEDROOM
CLOSED
.
DOOR
TV ROOM
BEDROOM
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
GARAGE
KITCHEN
DINING
LIVING ROOM
BEDROOM
BEDROOM
01000-002-V0
Recommendations For Proper Intrusion Protection
• For proper intrusion coverage, sensors should be located at every possible point of entry to a home or premises. This
would include any skylights that may be present, and the upper windows in a multi-level building.
• In addition, we recommend that radio backup be used in a security system. This will ensure that alarm signals can be
sent to the alarm monitoring station in the event that the telephone lines are out of order (alarm signals are normally
sent over the phone lines, if connected to an alarm monitoring station).
- 2 -
Table of Contents
SYSTEM FEATURES ..................................................................................................................................5
MOUNTING THE CONTROL.....................................................................................................................6
LIMITATIONS OF THIS SYSTEM STATEMENT..................................................................................77
UL NOTICES..............................................................................................................................................78
SUMMARY OF CONNECTIONS DIAGRAM ..........................................................................................79
WARRANTY ............................................................................................................................... Back Cover
- 3 -
- 4 -
APX32EN Installation and Setup Guide
System Features
APX32EN is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N
UUUU
LLLL
The APX32EN control is a self-contained, rechargeable wireless control/communicators that feature easy
installation and usage. A built-in speaker provides voice annunciation of system status along with voice
descriptors of each zone. An internal module (if provided) allows the APX32EN to communicate with the
Central Station via the Internet. The following illustration highlights the main features of this system.
• Up to 24 wireless zones
(5800 Series Transmitters)
• Up to 16 wireless button zones
• Up to 8 Powerline Carrier Devices
• Supports wireless keypads
8 USER CODES
• Installer code
• Master code
• 5 Secondary codes
• Duress code
• 3 Panic functions
LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.
Powerline Carrier Devices have not been evaluated by UL.
ZONES and DEVICES
• Real-time Clock display and Fixed-Word display
• Message Center (for user recorded messages)
• Voice announcement of system and zone status
• Voice chime
• Alarm Clock
• Reminder
• Latch Key Reports
• Automatic Stay Arming
• Remote Phone Control
• “Follow Me” Reminder and System Announcements
FEATURES
SYSTEM POWER
• Primary Power: Ademco K10145X10
Plug-in Transformer, 110VAC to
9VAC, 25VA output
• Backup battery: Rechargeable
nickel-metal hydride battery pack
rated at 7.7Vdc.
COMMUNICATION
• Ademco Low Speed
• Sescoa/Radionics
• Ademco Express
• Ademco Contact ID
• Paging feature
• Internet Central
Station Communication
• GSM Cellular Central
Station Communication
PROGRAMMING
• Options stored in EEROM
• Can be uploaded, downloaded or
controlled via IBM-compatible
computer using Compass
downloader software and specified
HAYES modem or via capable GSM
or IP communications modules
• Voice Prompt programming mode
OTHER FEATURES
• Exit error feature (detects difference between an
actual alarm and exit alarm caused by leaving a
door open after the exit delay expires)
• Event log stores up to 84 events
• Macro/ 1-button paging
• RF Jam Detection
• Remote Phone Control
• Compatible with Encrypted (High-Security) Devices
• Two-way voice communication
• Speaker phone operation
ALARM OUTPUT
• Built-in sounder
• Piezo output
(30mA max.)
• Bell output
(120mA max.)
• Steady output for
burglary/panic
• Temporal pulse
output for fire alarms
• Long Range
Radio/Audio alarm
verification
REMOTE SERVICES
• Remote access feature
• Multi-mode (e-mail notification)
• SMS (short message service)
feature
- 5 -
APX32EN Installation and Setup Guide
Mounting the Control
Wall Mounting
The illustration below shows the front assembly separated from the back plate.
DO NOT disconnect the ribbon cable from the terminal strip board. Disconnect the cable only from the
front assembly board.
!
1. Release the front assembly from the back
plate by depressing the two locking tabs
at the top of the unit with the blade of a
medium size screwdriver.
2. Once these tabs have been released,
insert the screwdriver in the side of the
case and release the side locking tabs by
gently twisting.
3. Carefully disconnect the ribbon cable from
the front assembly, leaving the ribbon
cable connected to the terminal block
PC board. The back plate contains the
terminal block for making wiring
connections.
4. Mount the back plate to a sturdy wall,
feeding the field wiring through the
appropriate openings in the back plate.
5. After wiring connections are made,
carefully reconnect the ribbon cable to
the front assembly PC board connector
(properly aligning the red wire).
6. Snap the front assembly to the back plate
so it is secured by the locking tabs.
LOCKING
TABS
DISCONNECT
THIS END ONLY!
LOCKING TABS
RED WIRE
MARKING
LOCKING
TABS
Desktop Mounting
For desktop use the optional mounting base (model LYNX-DM, purchased separately) must be used.
1. Slide the control panel onto the mounting
base locking tabs.
2. Bring all wiring through the bottom of the
mounting base, using one of the three
wire entry locations, before making
connections to the control panel.
3. Use tie-wraps to secure the wiring to the
built-in wire loops as needed. Use the two
supplied screws to secure the control
panel to the mounting base.
WIRE ENTRY
KNOCKOUT
- 6 -
09012-002-V0
(1 of 3)
09012-011-V0
APX32EN Installation and Setup Guide
Wiring Connections
Wiring Overview
The following summarizes the connections required. Refer to the Wiring Connections paragraph and the
Summary of Connections diagram on the inside back cover when making connections.
UUUU
LLLL
External sounders have not been evaluated by UL.
TERMINAL
STRIP
TELEPHONE
CONNECTIONS
7845i-L
CONNECTIONS
PORT
TO
HANDSET
PHONE
LINE
WARNING:
TO PREVENT
RISK OF SHOCK
DISCONNECT
TELEPHONE LINE
AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT.
7845i-L
CONNECTIONS
PORT
GSMVL
COMMUNICATIONS
PORT
STANDARD
HIGH-CAPACITY
BATTERY CONNECTOR
SUPER HIGH-CAPACITY
BATTERY CONNECTOR
THE APX32EN CONTROL IS COMPATIBLE WITH
THE FOLLOWING INTEGRAL RECHARGEABLE
BATTERY PACKS:
P/N LYNXRCHKIT-SC
P/N LYNXRCHKIT-HC
P/N LYNXRCHKIT-SHA
REPLACE EVERY FOUR YEARS
* WHEN AVAILBLE
RJ11
GSMVL
COMMUNICATIONS
PORT
BATTERY CONNECTOR
INCOMING
PHONE
LINE
EARTH
GROUND
POS
JACK
8
2
1
TIP
INCOMING
TELEPHONE
LINE
EARTH
GROUND
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM
SUPER HIGH-CAPACITY
BATTERY CONNECTOR
STANDARD
HIGH-CAPACITY
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAUGE
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
FUTURE
RING
USE
7
GND
DATA IN
FUTURE
USE
USE ONLY THE K10145X10
TRANSFORMER PROVIDED
PHONE
3
RING
4
TIP
PREMISES
TELEPHONE
UL NOTE
865
DATA OUT
GND
9
( )
NOTE
SOUNDERS
10
(+)( )
PIEZO
6-14VDC
30mA max.
(e.g. WAVE2EX)
12
11
( )
(+)
BELL
6-14VDC
120mA max.
LOCAL SOUNDER
DISABLE SHUNT
REMOVE TO DISABLE
PLCD
15
13
14
DATA
SYNC
OUT
IN
POWERLINE
CARRIER DEVICES
LOCAL
SOUNDER
DISABLE
AC
16
K10145X10
PLUG-IN
TRANSFORMER
9VAC, 25VA
AC
AC
SYNC
COM
DATA
ONLY
CONNECTIONS
X10
09012-010-V0
09012-009-V0
APX32EN Wiring Connections
- 7 -
APX32EN Installation and Setup Guide
Wiring Connections
1. Make Earth Ground Connection - The designated earth ground terminal (1) must be terminated in a good earth ground
for the lightning transient protective devices in this product to be effective. The following are examples of good earth
grounds available at most installations:
Metal Cold Water Pipe - Secure a non-corrosive metal strap (copper is recommended) to the pipe that is electrically
connected and secured to which the ground lead is electrically connected and secured.
AC Power Outlet Ground - Available from 3-prong, 120VAC power outlets only. To test the integrity of the ground
terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61–035, or
equivalent, available at most electrical supply stores.
a. Connect terminal 1 to a good earth ground.
2. Make Phone Line Connections - For local or full line seizure proceed to the appropriate steps below.
Local Seizure
a. Connect the incoming phone line to either the
8-position jack or terminals 2 (TIP) and 3
(RING) on the Lynx.
b. Connect the handset phone lines to either the
RJ11 jack or terminals 4 (TIP) and 5 (RING).
45
3
RJ31X
Full Line Seizure: The control must be
placed in series with the incoming phone
line. Plugging the Direct Connect Cord
GREY
2
1
directly into the RJ31X jack, allows the control
to seize the phone line when an alarm occurs
and normal phone line usage by the premises
phones if the plug needs to be removed.
c. Cut the incoming RING and TIP phone lines
(typically red and green, respectively) and
connect them to RJ31X terminals 4 (red) and
OR
OR
5 (green).
d. Connect the premises end of the cut RING
and TIP wires to RJ31X terminals 1 (grey) and
8 (brown) respectively.
e. Wire the flying leads of a Direct Connect Cord
to the control’s phone terminals as shown in
the diagram or plug into the 8-position jack.
RED
GREEN
TIP RING TIP RING
}
INCOMING
PHONE LINE
BROWN
}
TO
PREMISES
PHONES
GREY
f. Plug the Direct Connect Cord into the RJ31X
jack.
UUUU
Do not remove the local sounder shorting jumper (shunt).
LLLL
External sounders and powerline carrier devices have not been evaluated by UL
Full Line Seizure Connections
LOCAL SOUNDER DISABLE: The Master Keypad’s built-in piezo sounder can be disabled by removing the
shorting jumper (shunt) on the terminal board. If disabled, however, no sounding will occur upon AC loss,
since the external sounder does not operate when AC power is lost.
3. Make External Sounder Connections - The control panel supports either a 6-14VDC piezo sounder (30mA max.) or
6-14VDC bell (120mA max.; e.g. ADEMCO WAVE2EX).
a. Connect a piezo sounder to terminals 10 (+) and 11 (–); OR a bell to terminals 11 (–) and 12 (+).
4. Disable Local Sounder Option - If required the Master Keypad’s built-in piezo sounder can be disabled.
a. Remove the shorting jumper (shunt) on the terminal board.
5. Make Powerline Carrier Device Connections - The control panel supports up to 8 Powerline Carrier Devices. If using
these devices, they must be connected to the K10145X10 transformer, as shown in the SUMMARY OF
CONNECTIONS diagram.
a. Connect the com/data/sync/ lines from the transformer to terminals 9, 13, and 14, respectively.
6
7
8
DIRECT
CONNECT
CORD
8-POSITION
JACK
INCOMING
PHONE LINE
RING
TIP
GREENRED
PREMISES PHONES
RING
TIP
BROWN
TO
01000-008-V0
- 8 -
APX32EN Installation and Setup Guide
Connecting/Configuring Communication Modules
General
This APX32EN supports central station reporting via the internet using wireless (GSM) and hardwire (IP)
communications modules. It also supports upload/download programming capability via the Internet or a
Private local area network (Intranet). This allows site maintenance independent of central station
monitoring, and modification to sites globally via the Internet or through a private LAN. Refer to the
instructions provided with the LRR/IP Communications Device being installed for additional information
regarding its installation, programming, and registration. Zone 103 is the supervisory zone for the
Communications Device.
APX32EN does not support the 7845i-ENT remote access feature.
Connecting Long Range Radio and Internet Communication Devices
Connect and configure the communications device as follows (refer to the Installation Instructions for device
that you are installing for additional information):
The wire run between the APX32EN and the Communications Device must not exceed ten (10) feet.
UUUU
The 7845I-ENT has been evaluated by UL for Household Burglary installations. The communications
LLLL
modules have not been evaluated for Household Fire installations.
AlarmNet 7847i-L* Communications Device
1. Install the module into the APX32EN back plate and secure it with the two provided screws. Refer to the diagrams below.
2. Connect the provided ribbon cable between the module and the PC board. This cable provides DC power and ground for
the module and data in/data out connections.
3. Connect the device to the Internet via a cable/DSL modem and router or to an Intranet (LAN) via the appropriate Ethernet
connection.
* When available. The 7847i-L module has not been evaluated by UL.
CABLE
7720P
PROGRAMER
CONNECTION
SCREW (2)
RJ45
(FOR INTERNET CONNECTION)
COMMUNICATION PORT
FOR INTERNAL 7845i-L
MODULE ONLY
09012-008-V0
Installing the 7847i-L Communications Module
- 9 -
APX32EN Installation and Setup Guide
AlarmNet 7845GSM, 7845i-GSM, 7845i-ENT, 7847i-E* or 7845i, Communications Device
The 7845i-ENT/7845i and 7845CV2 can not be used for installations requiring 24-hour standby.
!
1. Connect the 4-wire communications cable to the LRR/IP Communications port on the APX32EN.
2. Connect the four wires to the specific Communications device as shown in the accompanying figures.
3. If you are installing a 7845GSM or 7845i-GSM you must also install a jumper between terminals 2 and 3 on the
communications device.
4. Connect the device to the Internet via a cable/DSL modem and router or to an Intranet (LAN) via the appropriate Ethernet
connection, if applicable.
UUUU
The AlarmNet 7845GSM and 7845i-GSM have been evaluated by UL.
LLLL
TB1
1
2
LYNX
SUPER HIGH
CAPACITY
BATTERY
YEL
RED
NC
DATA OUT
(OPTIONAL)
REQUIRED FOR
24-HR BACKUP
BLK
GND
+12 VDC
GRN
DATA IN
LYNX
STANDARD
CAPACITY
BATTERY
4-WIRE CABLE (N4632-4)
LRR/IP COMMUNICATIONS PORT
LYNXR-I CONTROL PANEL
RED
BLK
YEL
GRN
ECP (+) VOLTAGE INPUT
4
3
GND
4
5
5
Z1/Z2 OR DATA IN
6
Z3 OR DATA OUT
7845GSM / 7845i-GSM
7845i-GSM-010-V0
YEL
NC
DATA OUT
BLK
RED
GRN
GND
+12 VDC
LYNX
STANDARD
CAPACITY
BATTERY
Connecting AlarmNet 7845GSM / 7845i-GSM
4-WIRE CABLE (N4632-4)
(+) VOLTAGE INPUT
TB 1
BLK
RED
LRR/IP COMMUNICATIONS PORT
DATA IN
LYNXR-I CONTROL PANEL
RED
BLK
GRN
YEL
Connecting AlarmNet 7845i-ENT/7845i/7847i-E*
- 10 -
7845i-ENT / 7845i
GND
DATA OUT
GRN
YEL
DATA IN
07000-013-V2
APX32EN Installation and Setup Guide
AlarmNet GSMVL Communications Device
1. Install the module into the APX32EN back plate and secure it with the three provided screws.
2. Insert the antenna into the retaining slots in the APX32EN back plate.
3. Use double-stick tape to secure antenna to the APX32EN back plate.
4. Connect the provided communications cable between the GSMVL module and the APX32EN PC board. This cable
provides DC power and ground for the module and data in/data out connections.
5. Connect the provided shielded audio cable between the GSMVL module and the APX32EN PC board.
SCREW (3)
COMMUNICATIONS
CABLE
GSMVL
ANTENNA
AUDIO
CABLE
09012-017-V0
Installing the GSMVL Communications Module
LRR/IP Communications Device 24-Hour Standby Power
If you are installing the AlarmNet 7845GSM/7845i-GSM or 7845i-L you must install the Super High
Capacity battery P/N WALYNX-RCHB-SHA in the APX32EN.
The 7845i-ENT/7845i cannot be used for installations requiring 24-hour standby.
!
Configuring Long Range Radio and Internet Communication Devices
1. Enable the communications device in programming field *55 and configure alarm reporting and module supervision in
programming field *77.
2. Program the device as required using the 7720P programmer (refer to the Installation Instruction for the device that you
are installing for additional information). Note that the device address must be set to 3.
The device must be registered before downloading or alarm reporting can take place.
- 11 -
APX32EN Installation and Setup Guide
V
AC Power and Backup Battery
The system is powered by a 9VAC, 25VA Plug-in Transformer, ADEMCO K10145X10. Refer to the wiring
table below for wire gauge and length.
Use only the provided ADEMCO K10145X10
Transformer.
Wiring to the AC Transformer must not exceed 300 feet using 16-gauge wire. The voltage reading
between terminals 15 and 16 of the control must not fall below 9.00VAC.
Do not plug the transformer into the AC outlet until after all wiring connections have been made.
Backup battery
In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for
connection and for low voltage conditions. If the battery is missing, or a low battery condition is detected, a
“low battery” message is displayed and a report is sent to the central station. In addition, the system will beep
once every 45 seconds to audibly indicate a low battery condition (press any key to stop the beeping).
AC Power and Rechargeable Backup Battery
Connecting AC Power and backup battery
1. Connect wires from the K10145X10 AC Transformer to
terminals 15 and 16 as shown in the wiring diagram.
2. Remove battery retainer.
3. Peel the backing from tape on the back plate.
4. Insert battery pack into back plate.
5. Install battery retainer.
6. Connect battery connector to receptacle on terminal
block PC board.
7. After all wiring connections have been made, snap the
front assembly to the back plate and plug the
transformer into a 24-hour, 110VAC unswitched outlet.
Note: Rechargeable batteries may take up to 48-hours to
fully charge. The “LOW BAT” message should clear
within four hours or by entering Test Mode.
BATTERY
PACK
Distance from Transformer
to Control
Up to 75 feet #20
75 to 150 feet #18
150 to 300 feet #16
RETAINER
TAPE
Wire Gauge
NOTE
LYNXRCHKIT-HC
BATTERY PACK SHOWN
Ensure the cover is snapped closed prior to applying AC power.
- 12 -
BATTERY
RECEPTACLE
WIRING
TERMINALS
09012-003-
APX32EN Installation and Setup Guide
AC Power and Rechargeable Backup Battery
The APX32EN is equipped with an integral, replaceable, rechargeable battery pack rated at 7.7Vdc. Select
the appropriate battery pack, based on the installation’s requirement, and install the battery pack.
Model/Part Number Battery StandbyTime
LYNXRCHKIT-SC 4-hours (minimum) Approximately 1-hour before battery depletion
LYNXRCHKIT-HC 24-hours (minimum) At least 1-hour before battery depletion
LYNXRCHKIT-SHA 24-hours (minimum) At least 1-hour before battery depletion
Replacing the Rechargeable Battery
1. When battery replacement is required,
unplug the transformer from the wall outlet,
and open the control panel cover.
2. Remove the battery retainer and disconnect
the battery pack connector from the
receptacle on the terminal block PC board.
3. Remove the battery pack from the back
plate.
4. If required, replace the tape that secures the
battery pack.
5. Install a replacement battery pack (P/N
LYNXRCHKIT-SC, LYNXRCHKIT-HC or
LYNXRCHKIT-SHA) into the back plate.
6. Install the battery retainer.
7. Connect the battery connector to the
receptacle on the terminal block PC board.
8. After the wiring connection has been made,
snap the front assembly to the back plate.
9. Plug the transformer into a 24-hour, 110VAC
unswitched outlet.
10. Rechargeable batteries may take up to 48hours to fully charge. The “LOW BAT”
message should clear within four hours or
by entering Test Mode.
Low Battery Notification
RETAINER
BATTERY
PACK
BATTERY
CONNECTOR
LYNXRCHKIT-HC OR LYNXRCHKIT-SC
BATTERY
CONNECTOR
BATTERY
RECEPTACLE
RETAINER
BATTERY
PACK
LYNXRCHKIT-SHC
TAPE
TAPE
BATTERY
RECEPTACLE
09012-004-V0
Ensure the control panel assembly is snapped closed prior to applying AC power.
- 13 -
APX32EN Installation and Setup Guide
Installing Wireless Zones
General Information
Zones: The control supports up to 24 wireless zones using 5800 Series transmitters, and up to 16 wireless
buttons.
Range: The built-in RF receiver can detect signals from wireless transmitters within a nominal range of 200
feet.
Transmitters: 5800 Series transmitters have built-in serial numbers that must be entered into the system
using the
(except the 5800RL, which is described separately) do not have DIP switches. Each transmitter's zone
number is programmed into the system in
support more than one "zone" (referred to as loops or inputs). On the 5816, for example, the wire connection
terminal block is loop 1, the reed contact is loop 2. Each loop must be assigned a different zone number.
UUUU
For button transmitters (RF "keys") such as the 5804 and 5801, you must assign a unique zone number to
each individual button used on the transmitter. Each button on the transmitter also has a pre-designated
loop or input number, which is automatically displayed.
House Identification
If you are using a 5804BD/5804BDV Wireless Keypad with the system, you must program a House ID Code
(01–31) in field
ID 00 disables all wireless keypads. An RF House ID is not necessary for other 5800 Series transmitters; the
entry should be left at “00” (default) in those cases.
Transmitter Supervision
Except for some transmitters/keypads that may be carried off-premises (5804, 5804BD, 5804BDV, and
5804E), each transmitter is supervised by a check-in signal that is sent to the receiver at 70–90 minute
intervals. If at least one check-in is not received from each supervised transmitter within a 12-hour period,
the "missing" transmitter number(s) and "OPEN" will be displayed. The supervision for a particular
transmitter in the system that may also be carried off the premises (5801, 5802MN) may be turned off by
entering it as a "UR" (unsupervised RF) type, as described in the
section.
5800 Series transmitters have built-in tamper protection and will annunciate as a fault condition if covers
are removed.
Transmitter Input Types
Each of the following transmitters has one or more unique factory-assigned input (loop) ID codes. Each of the
inputs requires a programming zone (e.g., a 5804's four inputs require four button zones).
Transmitters can be entered as one of the following types (see transmitter’s instructions for appropriate
input type):
"RF" (Supervised RF) Sends periodic check-in signals, as well as fault, restore, and low battery signals.
"UR" (Unsupervised RF) Sends all the signals that the "RF" type does, but the control does not supervise the
"BR" (Unsupervised Button RF) These only send fault signals. They do not send low battery signals until they are
Transmitter Battery Life
• Batteries in the wireless transmitters may last from 4–7 years, depending on the environment, usage, and
the specific wireless device being used. Factors such as humidity, high or low temperatures, as well as
large swings in temperature may all reduce the actual battery life in a given installation. The wireless
system can identify a true low battery situation, thus allowing the dealer or user of the system time to
arrange a change of battery and maintain protection for that point within the system.
✻56 or ✻83 interactive mode, or input to the control via the downloader. 5800 Series transmitters
✻56 mode. Some transmitters, such as the 5816 and 5817, can
The 5816 and 5817 Transmitters do not have EOL supervision of their loop wiring and the loop wiring must
not exceed 3 feet.
LLLL
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5814, 5816TEMP, 5819, 5819S(WHS &
BRS), 5828/5828V and 5850(GBD) transmitters have not been evaluated by UL.
✻24 to establish proper communication, and the keypad must be set to the same ID. House
✻56 Enhanced Zone Programming Mode
Type Description
The transmitter must remain within the receiver's range.
check-in signals. The transmitter may therefore be carried off-premises.
activated. The transmitter may be carried off-premises.
- 14 -
APX32EN Installation and Setup Guide
• Button-type transmitters should be periodically tested for battery life. The 5801, 5802MN, 5802MN2,
5804, 5804BD, 5804BDV, and 5804E button transmitters have replaceable batteries.
Using the Transmitter Sniffer Mode
Use this mode after all transmitters have been entered to check that all transmitters have been properly
programmed.
1. Enter Installer code (4112) + [#] + 3.
Note: If the communicator is in the process of sending a report to the central station, the system will not go into the Sniffer
mode. If so, wait a few minutes and try again.
2. The keypad will display all zone numbers, which have a non-zero Zone Type (even if serial numbers were
not learned yet). Fault each transmitter in turn, causing each one to send a signal. As the system
receives a signal from each of the transmitters, the zone number of that transmitter will disappear
from the display. The transmitters may be checked upon installation, or in an installed system.
3. When all transmitters have been checked, exit Sniffer mode. Enter Installer Code (4112) + OFF.
Notes: (1) Sniffer mode does not automatically expire. You must manually exit (Installer Code + OFF) Sniffer
(2) All BR-type units must physically be activated to clear the display, since they do not automatically send check-in
(3) When one button of a transmitter (RF, UR, or BR) is activated, all zones assigned to other buttons on that
(4) Any transmitter that is not “entered” will not turn off its zone number.
mode to return to normal operation.
signals.
transmitter are cleared. This also applies to 5816 and 5817 transmitters that have multiple loops (zones).
Go/No Go Test Mode
5804E encrypted (High-Security) devices must be activated while the system is in Go/No Go Test Mode.
Refer to the transmitter’s installation instructions for complete details. The system will confirm
enrollment of the encrypted device by beeping two times.
The Go/No Go tests will verify adequate RF signal strength from the proposed transmitter location, and
allow you to reorient or relocate transmitters if necessary, before mounting the transmitters permanently.
This mode is similar to the transmitter Test mode, except that the wireless receiver gain is reduced. This
will enable you to make sure that the RF signal from each transmitter is received with sufficient signal
amplitude when the system is in the normal operating mode.
1. Enter Installer Code (4112) + [#] + 8.
2. Once you have placed transmitters in their desired locations and the approximate length of wire to be
run to sensors is connected to the transmitter's screw terminals (if used), fault each transmitter.
Conducting this test with your hand wrapped around the transmitter will cause inaccurate results.
On button type transmitters that have been programmed to set ARM AWAY, ARM STAY, or DISARM,
pressing a button will take the system out of the Go/No Go Test mode and cause the programmed action
to occur.
Note: On button type transmitters that have been programmed to set ARM AWAY, ARM STAY, or DISARM, pressing a button
will take the system out of the Go/No Go Test mode and cause the programmed action to occur.
a. The keypad will beep three times indicating signal reception and will display the appropriate zone
number.
b. If the keypad does not beep, reorient or move the transmitter to another location. Usually a few
inches in either direction is all that is required.
3. If each transmitter produces the proper keypad response when it is faulted, you can then permanently
mount each of the transmitters according to the instructions provided with them.
4. Exit the Go/No Go Test mode by entering: Installer Code (4112) + OFF.
- 15 -
APX32EN Installation and Setup Guide
5800 Series Transmitter Loop Numbers (Refer to this information when programming transmitters)
The following illustration shows the compatible transmitters, their associated input types and loop
designations.
LOOP
LOOP 4
YOU MUST
ENROLL
THIS
1
BUTTON
LOOP 3
LOOP 2
LOOP 1
LOOP
LOOP 4
YOU MUST
LOOP
1
1
ENROLL
THIS
BUTTON
LOOP 3
O
N
O
F
LOOP 2
F
LOOP 1
LOOP 3
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
LOOP 1
LOOP 1
(TEMP
SENSOR)
5804BD/5804BDV
ENROLL AS
PROGRAM HOUSE ID
"BR"
5817
ENROLL AS
5890/5890PI
ENROLL AS
"RF"
"RF"
5800CO
ENROLL AS "RF"
LOOP 1
5806/5807/5808/5808LST
ENROLL AS
"RF"
LOOP 1
5818
ENROLL AS
"RF"
5800RL
HOUSE ID
LOOP 2
(REED)
LOOP 3
(TERMINALS)
SET
ENROLL AS
ENROLL AS
5809
5819
5800WAVE
PROGRAM
HOUSE ID
LOOP 1
"RF"
LOOP 1
(TERMINALS)
"RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5819S (WHS & BRS)
5801
ENROLL AS
"UR" OR "RF"
5814
ENROLL AS
ENROLL AS
LOOP 1
"RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
"RF"
5802 MN
ENROLL AS
"UR" OR "RF"
5816
ENROLL AS
ARMED
READY
5828/5828V
PROGRAM
HOUSE ID
LOOP 2
(REED)
LOOP 1
(TERMINALS)
"RF"
5802 MN2
ENROLL AS
"UR" OR "RF"
LOOP 2
(REED)
LOOP 1
5816MN
5849
ENROLL AS
(TERMINALS)
"RF"
LOOP 1
(SOUND)
"RF"
ALTERNATE
POSITION
FOR LOOP 2
ENROLL AS
MIC
MESSAGE
5804/5804E
ENROLL AS "BR"
5816TEMP
ENROLL AS
5850 (GBD)
ENROLL AS
"RF"
(Green)
(Red)
(Yellow)
"RF"
Notes: (1) Loop 4 must be enrolled on the 5801, 5804, 5804BD, 5804BDV and 5804E transmitters, whether or not the loop is used.
(2) 5804E encrypted (High-Security) devices must be activated while the system is in Go/No Go Test Mode. Refer to the
transmitter’s installation instructions for complete details. The system will confirm enrollment of the encrypted device by
UL
beeping two times.
The 5800CO, 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5814, 5816TEMP, 5819, 5819S(WHS &
BRS), 5828/5828V and 5850(GBD) wireless transmitters
have not been evaluated by UL.
Setting DIP Switches on the 5800RL Transmitter
Set the 5800RL Transmitters to the programmed House ID, by using the DIP switches.
LOOP 1
(PRIMARY)
LOOP 2
(AUX.
CENTER)
LOOP 3
(AUX.
RIGHT)
LOOP 1
(MOTION)
09012-013-V0
(OFF position is indicated by ---)
Note: The 5800RL cannot be used in conjunction with the Auto Arm (scheduled arming) feature.
234561
SW-1 ACTIVATES
MODE SETTING
2-6 SETS HOUSE ID
SHOWN SET FOR HOUSE ID# 12
SWITCH UP FOR "ON"
SW-6 SETS
MODE
SWITCH DOWN
FOR "OFF"
01000-014-V1
ID
0 --- --- --- --- --- 16 ON --- --- --- --1 --- --- --- --- ON 17 ON --- --- --- ON
2 --- --- --- ON --- 18 ON --- --- ON --3 --- --- --- ON ON 19 ON --- --- ON ON
4 --- --- ON --- --- 20 ON --- ON --- --5 --- --- ON --- ON 21 ON --- ON --- ON
6 --- --- ON ON --- 22 ON --- ON ON --7 --- --- ON ON ON 23 ON --- ON ON ON
8 --- ON --- --- --- 24 ON ON --- --- ---
9 --- ON --- --- ON 25 ON ON --- --- ON
10 --- ON --- ON --- 26 ON ON --- ON --11 --- ON --- ON ON 27 ON ON --- ON ON
12 --- ON ON --- --- 28 ON ON ON --- --13 --- ON ON --- ON 29 ON ON ON --- ON
14 --- ON ON ON --- 30 ON ON ON ON --15 --- ON ON ON ON 31 ON ON ON ON ON
DIP SWITCH POSITIONS DIP SWITCH POSITIONS House
2 3 4 5 6
5800RL DIP SWITCH TABLE
Setting 5800RL DIP Switches
- 16 -
House
ID
2 3 4 5 6
APX32EN Installation and Setup Guide
Mechanics of Programming
General Programming Information
Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. The
system can be programmed at any time, even at the installer's premises prior to the actual installation.
Simply apply power temporarily to the Control and then program the unit as desired. There are four
programming modes:
• Data field programming (used for setting various system options).
• Interactive menu mode programming (used for programming zone information, programming
Powerline Carrier Devices, and for entering transmitter serial numbers).
• Voice Prompt programming (used for setting various system options).
• Pass-Thru programming (used for programming connected LRR/IP Communications Device).
The system can also be programmed remotely, using an IBM Personal Computer and Compass
Downloader and modem or via capable GSM or IP communications modules. See the Remote Programming/Control (Downloading) section.
Note: You may find it convenient to adjust the volume setting before entering the Program Mode. This will allow you to
clearly hear the feedback announcements or system beeps in the Programming Mode, of the system’s built-in
speaker. To adjust the volume, press FUNCTION + VOLUME+ [3] or [6]. Upon exiting the Program Mode, the
system will reset the volume to the default value (mid level).
Entering Program Mode
Use one of the following methods to enter Programming Mode:
1. Press both the [
Control or from exiting Programming mode, OR
2. After power-up, enter the Installer Code (4112) + 800 to enter Expert Programming mode (This
method disabled if Program mode is exited using
Voice Prompt Programming mode.
✻] and [#] keys at the same time, within 50 seconds after power is applied to the
✻98). OR enter Installer Code (4112) + 888 to enter
If a different Installer Code has been programmed, use that code to enter the Programming mode.
3. Upon entering programming mode, the control will display “--” for up to two seconds indicating it is
communicating with the LRR/IP devices.
4. Once you have entered the Program mode, data field “20” (the first data field in the system) will be
displayed and both keypad LEDs will flash. If you have entered the Voice Prompt Programming mode.
“Pro” will be displayed.
Programming a Data Field
1. Press [✻] + Field No. (for example, ✻21), followed by the required entry.
2. When you have completely programmed a data field, the keypad will “beep” three times and then
automatically display the next data field in sequence. To go to a different field, press [
desired field number.
3. If the number of digits that will be entered in a data field is less than the maximum number of digits
available (e.g. phone number field), enter the desired data, then press [
✻] to advance to the next data
field.
4. If a nonexistent field has been entered, the keypad will display “EE”. Simply re-enter [
field number.
To view a data field without making changes: Enter [#] + Field No. Data will be displayed for that field.
To delete an entry in a field
: Enter [✻] + Field No. + [✻].(Applies only to fields ✻40–✻44, ✻88 and ✻94).
✻] plus the
✻] plus a valid
- 17 -
APX32EN Installation and Setup Guide
Interactive Menu Mode Programming (✻56, ✻80, ✻81, ✻83, ✻84, ✻85)
Press [✻] + interactive mode No. (i.e.,✻56). The keypad will display the first of a series of prompts. A detailed
procedure (with displays of prompts) is provided in later sections of this manual.
Interactive ModeUsed to Program
56 Enhanced Zone Programming Mode
✻
✻80 Device Programming Menu ModePowerline Carrier Devices
✻81 Zone List Menu Mode Zone Lists for powerline carrier activation
83 Enhanced Sequential Mode
✻
✻84 Assign Zone Voice DescriptorsVoice descriptors for each zone
✻85 Record Custom Voice DescriptorsUp to 5 custom voice descriptors for zones
Zone characteristics, report codes, and serial numbers
5800 Series transmitter serial numbers
Loading Factory Defaults
To load the factory defaults, enter the Programming mode, press ✻97, then press number 1, 2, 3, or 4 to
select from default tables 1-4 at the back of this manual, or press “0” if you are not selecting a default table.
If a default table is loaded, any data that has already been programmed into the system will be changed according to the
default table selected!
✻96 resets all subscriber account numbers and CSID in preparation for an initial download.
Exiting Program Mode
✻98 inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code.
✻99 allows re-entry into the Expert Program mode using Installer Code (4112) + 800 or into the
Voice Prompt Programming mode using Installer Code (4112) + 888.
Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset
delay, press [#] + [0].
Pass-Thru Programming
This mode allows the Installer to use the APX32EN keypad and display to program the communications
device that is connected to the APX32EN. Refer to the communications device’s installation instruction to
determine whether this feature is supported.
Entering Pass-Thru Programming mode
1. After power-up, enter the Installer Code (4112) + 899.
2. Once you have entered Pass-Thru Programming mode “PtP” will be displayed on the keypad.
3. Refer to the Installation Instructions for the LRR/IP Communications Device being installed for
additional programming information.
APX32EN will abort this mode:
• When it receives an abort command from the new communications device.
• If it fails to communicate with a communications device after 20 attempts.
• 30 minutes after the last key has been pressed.
- 18 -
APX32EN Installation and Setup Guide
Zone Response Type Definitions
General Information
During programming, you must assign a zone type to each zone, which defines the way in which the system
responds to faults in that zone. Zone types are defined below.
Type 00
Zone Not Used
Type 01
Entry/Exit
Burglary #1
Type 02
Entry/Exit
Burglary #2
Type 03
Perimeter
Burglary
Type 04
Interior,
Follower
Type 05
Trouble by Day/
Alarm by Night
Type 06
24-hour
Silent Alarm
Type 07
24-hour
Audible Alarm
Type 08
24-hour
Auxiliary Alarm
Zone type 00 is used to program a zone that is not used.
Zone type 01 is usually assigned to sensors or contacts on primary entry and exit doors.
Zone Characteristics:
• Entry delay #1 is programmable from 0-99 seconds (field ✻35).
• Exit delay is independently programmable from 0-99 seconds (field ✻34).
• Exit and entry delays when armed in AWAY or STAY mode.
• No entry delay when armed in STAY NO DELAY or AWAY NO DELAY mode.
• Exit delay regardless of the arming mode selected.
Zone type 02 is usually assigned to sensors or contacts on which secondary entry and exit doors
that might be further from the keypad (typically used for a garage, loading dock, or basement
door).
Zone Characteristics:
• Entry delay #2 is programmable from 0-99 seconds (field ✻36).
• Exit delay is independently programmable from 0-99 seconds (field ✻34).
• Secondary entry delay, if armed in the AWAY or STAY mode.
• No entry delay when armed in the STAY NO DELAY or AWAY NO DELAY mode.
• Exit delay begins regardless of the arming mode selected.
Zone type 03 is usually assigned to all sensors or contacts on exterior doors and windows.
Zone Characteristics:
• Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO DELAY mode.
Zone type 04 is usually assigned to a zone covering an entry area (i.e.: foyer, lobby, or hallway)
that one must pass upon entry (after faulting the entry/exit zone) to reach the keypad. It
provides an instant alarm if the entry/exit zone is not violated first, and protects an area in the
event an intruder has hidden on the premises before the system is armed, or gains access to the
premises through an unprotected area.
Zone Characteristics:
•Delayed alarm (using the programmed entry/exit time) if entry/exit (types 01 or 02) or
interior-with-delay (type 10) zone is faulted first.
• Instant alarm in all other situations.
• Active when armed in AWAY or AWAY NO DELAY mode.
• Bypassed automatically when armed in STAY or STAY NO DELAY mode.
Zone type 05 is usually assigned to a zone that contains foil-protected doors or windows or covers
a sensitive area (i.e.: stock room, drug supply room, etc.) It can also be used on a sensor or
contact in an area where immediate notification of an entry is desired.
Zone Characteristics:
•Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO DELAY
(night) mode.
•Provides a latched trouble sounding from the keypad and, if desired, a central station report
during the disarmed state (day).
Zone type 06 is usually assigned to a zone containing an Emergency button (silent emergency).
Zone Characteristics:
•Sends a report to the central station but provides no keypad display or sounding.
Zone type 07 is usually assigned to a zone containing an Emergency button (audible emergency).
Zone Characteristics:
• Sends a report to the central station, and provides alarm sounds externally and at the
keypad.
Zone type 08 is usually assigned to a zone containing a button for use in personal emergencies or
to a zone containing monitoring devices (i.e.: water or temperature sensors, etc.).
Zone Characteristics:
Sends a report to the central station and provides an alarm sound at the keypad. (No bell output
is provided and there is no keypad timeout.)
- 19 -
APX32EN Installation and Setup Guide
Zone Response Type Definitions
Type 09
Supervised Fire
Type 10
Interior w/Delay
Type 14
24-hour Carbon
Monoxide
Monitor
Type 20
Arm–Stay
Type 21
Arm–Away
Type 22
Disarm
Type 23
No Alarm
Response
Type 24
Silent Burglary
Zone type 09 can be assigned to any wireless zone used as a fire zone. This zone type is always
active and cannot be bypassed.
Zone Characteristics:
• Bell output will pulse when this zone type is alarmed.
Zone type 10 is bypassed when the panel is armed in STAY or STAY NO DELAY mode.
Zone Characteristics:
• Entry delay #1 (with programmed entry time) when armed in the AWAY mode.
• Entry delay begins whenever sensors in this zone are violated, regardless of whether an
entry/exit delay zone was tripped first.
• No entry delay when armed in the AWAY NO DELAY mode.
• Exit delay regardless of the arming mode selected.
Zone type 14 can be assigned to any wireless zone with a carbon monoxide detector. This zone type
is always active and cannot be bypassed.
Zone Characteristics:
Bell output will pulse when this zone type is alarmed.
Zone type 20 is a special-purpose zone type used with 5800 Series wireless pushbutton units.
Zone Characteristics:
• Exit delay regardless of the arming mode selected.
• System is armed in the STAY mode when the zone is activated.
• Zone number is sent to the central station as a user number when arming or disarming.
Zone type 21 is a special-purpose zone type used with 5800 Series wireless pushbutton units.
Zone Characteristics:
• System is armed in the AWAY mode when the zone is activated.
• Zone number is sent to the central station as a user number when arming or disarming.
Zone type 22 is a special-purpose zone type used with 5800 series wireless pushbutton.
Zone Characteristics:
• Disarms the system when the zone is activated.
Zone type 23 can be used on a zone when a Powerline Carrier Device (e.g., X10) action is desired,
but with no accompanying alarm (e.g., front door light).
Zone type 24 is usually assigned sensors or contacts on exterior doors and windows where bells
and/or sirens are NOT desired.
Zone Characteristics:
• Instant alarm, with NO audible indication when is armed in the AWAY, STAY, STAY NO
DELAY, or AWAY NO DELAY mode.
• Report sent to the central station.
Note: Keypad beeps if the zone is faulted when system is disarmed and Chime mode is on.
- 20 -
APX32EN Installation and Setup Guide
Data Field Descriptions
Defaults (where applicable) are Indicated in bold text.
The following pages list all data fields in this Control (in numerical order). Use the blank programming form
to record the data for this installation. Note that both keypad LEDs flash while in Programming mode.
Note: Entering a number other than the one specified will give unpredictable results.
20
✻
✻21
✻22
✻23
✻24
✻25
✻26
✻27
✻29
✻30
✻31
✻32
Installer Code
Enter 4 digits, 0-9
Quick Arm Enable
0 = do not allow quick arm
1 = allow quick arm
Keypad Backlight Timeout
0 = no timeout; always backlight keys
1 = turn backlighting off after inactivity
Forced Bypass
0 = no forced bypass
1 = provide automatic bypass of all open (faulted) zones
RF House ID Code
00 = disable all wireless keypad usage
01-31 = House ID
Powerline Carrier Device (X10) House ID
0 = A 4 = E 8 = I # + 12 = M
1 = B 5 = F 9 = J # + 13 = N
2 = C 6 = G # + 10 = K # + 14 = O
3 = D 7 = H # + 11 = L # + 15 = P
Chime by Zone
0 = no (chimes on fault of any entry/exit or perimeter
zone when Chime mode is activated)
1 = yes (chimes on fault of those zones assigned to
Zone List 3 when Chime mode on)
Real Time Clock Display
0 = do not display the time
1 = display the time
Daylight Savings Time Start/End Month
0, 0 = no daylight saving time used
1-12 = start month and end month
Daylight Savings Time Start/End Week
0 = disable 4 = fourth weekend
1 = first weekend of month 5 = last weekend
2 = second weekend 6 = next to last
3 = third weekend 7 = 3
rd
from last
Single Alarm Sounding Per Zone
(per armed period)
0 = Alarm Sounding Per Zone will be the same as the
Swinger Shutdown” set in field *92
1 = limit alarm sounding to once per arming period for
a given zone
Sounder Timeout
0 = yes, sounder timeout after time programmed in field
✻33
1 = no sounder timeout; continue sounding until
manually turned off
The Installer Code is used to enter the 4-digit Master Security
Code. See "Master Code" in the System Operation section for
procedure.
If enabled, security code is not required to arm the system. The
user simply presses and holds down the AWAY or STAY key to
arm.
This option allows the choice of either always backlighting the
keypad or turning the backlighting off after 10 seconds of
keypad inactivity.
All zones bypassed by this function will be displayed after the
bypass is initiated.
UL installations: must be 0 (no forced bypass)
The House ID identifies receivers and wireless keypads.
If a 5804BD/5804BDV Transmitter is to be used, a House ID
Code MUST be entered, and the keypad should be set to the
same ID.
Powerline Carrier Devices require a House ID. This field
identifies this House ID to the Control. The Powerline Carrier
Devices are programmed in field ✻80.
This option allows the installer to define the specific zones
intended to chime when faulted while the system is in Chime
mode. If enabled, these zones are defined in zone list 3 (see ✻81 Zone List Menu Mode).
Refer to the User’s Manual for setting the clock time and date.
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
Enter the appropriate start and end weekend of the month.
UL installations: must be 0
This field applies only to burglary zones (zone response types 15, 10), and affects long range radio reporting but does not affect
central station reporting.
Notes: 1. This field applies only to the bell and does not affect keypad
2. If swinger shutdown occurs (see Swinger Shutdown in Field
sounds.
✻92), the number of alarm soundings on a given zone will
be limited by the setting selected in Field ✻92.
This Control complies with NFPA requirements for temporal
pulse sounding of fire and carbon monoxide (CO) notification
appliances.
Temporal pulse sounding for a fire alarm consists of the
following: 3 pulses – pause – 3 pulses – pause – 3 pulses. . .
Temporal pulse sounding for a CO alarm consists of the
following: 4 pulses – pause – 4 pulses – pause – 4 pulses –
pause. . .
- 21 -
APX32EN Installation and Setup Guide
Data Field Descriptions
✻33
Alarm Bell Timeout
0 = No timeout 2 = 8 min 4 = 16 min
1 = 4 min 3 = 12 min
DELAY PROGRAMMING (✻34–✻36)
NOTE: The control validates the data entered in these fields. If the selection is not valid the control will emit a single long beep indicating that
the selection has been rejected. The control replaces the selection with the default value which is displayed on the keypad.
✻34
✻35
✻36
✻37
Exit Delay
00-99 = exit delay time in seconds
Entry Delay 01
00-99 = entry delay time in seconds.
Entry Delay 02
00-99 = entry delay time in seconds.
Audible Exit Warning/Quick Exit
Exit Warning Quick Exit
✻38
0 = no exit warning
sound
1 = provide exit
warning sound
when armed AWAY
Confirmation of Arming Ding
0 = no ding
0 = no quick
exit
1 = allow quick
exit
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button or RF
keypad only
✻39
Power Up In Previous State
0 = always power up in a disarmed state
1 = assume the system status prior to power-down
This field determines whether the external sounder will shut
off after time allowed, or continue until manually turned off.
UL installations: must be set for a minimum of 4 min (option 1)
The system will wait the time entered before sounding an
alarm if the exit door is left open after the system has been
armed.
UL installations: must be set for a maximum of 60 seconds
The system will wait the time entered before sounding alarm upon
entering if system is not disarmed. UL installations: must be set for a
maximum of 45 seconds
The system will wait the time entered before sounding alarm
upon entering.
UL installations: must be set for a maximum of 45 seconds
Exit Warning: Sound consists of slow continuous beeps until
last 5 seconds, when it changes to fast beeps. The warning
sound will end at the termination of exit delay.
Quick Exit: If enabled, user can restart the exit delay time after
arming in STAY mode by entering the user code and pressing
the STAY key, or by pressing the STAY key if Quick Arm is
enabled. This avoids having the user disarm then re-arm the
system after allowing someone to enter or exit
Confirmation of arming is provided by a 1/2 second external
sounder “ding” that sounds when closing report is sent, or at
the end of exit delay.
If Option 2 is selected the external sounder “ding” occurs
immediately after the system receives the RF transmission.
When the system powers up armed, an alarm will occur 1
minute after arming if a zone is faulted, and any bypassed
zones will be unbypassed.
Note: If the previous state was armed AWAY or STAY, the system
will not respond to sensor changes for 1 minute, which allows
time for sensors such as PIRs to stabilize.
UL installations: must be 1 (power up in previous state)
DIALER PROGRAMMING (✻40–✻50)
✻
Fields
for a pause
NOTES: Whenever AAV is used, primary (field ✻41) and secondary (field ✻42) phone numbers should be preceded with the
✻40
✻41
40, ✻41, ✻42: Enter up to the number of digits shown. Enter 0–9, # + 11 for ‘✻’; # + 12 for ‘#’; # + 13
(2 seconds)
call waiting disable command. Otherwise, there is the possibility of connection of the third party to APX32EN during
AAV mode. The
AAV). However, it is used for dialing on Telco Line line.
PABX Access Code
Enter up to 6 digits if PABX is needed to access an
outside line.
If the GSM/IP (Digital Communication with AAV) feature is used (options 5 and 7 in *55), there may be restrictions
when dialing the numbers entered in *41, *42 and *46 (i.e.; #, ✻, pause may not be allowed, or phone number
extensions may not be dialed, etc) depending on the service provider.
Primary Phone No.
Enter up to 20 digits.
PABX phone number entered in field ✻40 is not dialed on GSM/IP (Digital Communication with
If fewer than 6 digits need to be entered, exit by pressing [✻].
To clear entries from field, press ✻40✻.
If fewer than 20 digits entered, exit by pressing [✻]. To clear
entries from field, press ✻41✻.
Note: Backup reporting (8 attempts are made to the secondary phone
number if no kissoff is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number
(field ✻42).
- 22 -
APX32EN Installation and Setup Guide
Data Field Descriptions
✻42
Secondary Phone No.
Enter up to 24 digits.
All four digits of the Subscriber Account number must be entered in Fields ✻43 and ✻44. If ten-digit format is
selected in ✻48 (option 5), all ten digits of the Subscriber Account number must be entered.
Fields ✻43 and ✻44:
Enter [
✻
] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as
the first digit of a 4-digit account number for Nos. 0000–0999. Enter [
number (for 4+1, 4+2 CID®) is used. Exit field by pressing [
field, press
✻43✻ or ✻44✻
. See blank Programming Form for examples of account number entries. If using
the paging feature, do not enter a leading 0 in the subscriber account number, and do not use digits A-F
anywhere in the number. Some paging systems provide voice mail capability, which is activated by a leading
0 in the message. Enter digits 0–9; # +11=B; # +12=C; # +13=D; # +14=E; or # +15=F.
✻43
✻44
Primary Subs Account No.
Enter a four or ten digit account number.
Secondary Subs Account No.
Enter a four or ten digit account number.
Field 46: Enter up to 24 digits. Do not fill unused spaces. Enter 0-9, #+11 for ‘*’; #+12 for’#’; #+13 for a pause
(2 seconds).
“Follow Me Reminder” Phone Number
✻46
✻47
✻48
Enter up to 24 digits.
Phone System Select
Central Dialing Mode
Station Pulse Tone Pulse Tone
No WATS 0 = No
WATS 2 = No
Report Format for Primary/Secondary
Speaker
Phone
Speaker
Phone
1 = No
Speaker
Phone
3 = No
Speaker
Phone
4 = With
Speaker
Phone
6 = With
Speaker
Phone
5 = With
Speaker
Phone
7 = With
Speaker
Phone
Primary Secondary
See choices below See choices below
0 = 3+1; 4+1 ADEMCO Low Speed Standard
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Low Speed Standard
3 = 4+2 Radionics Standard
5 = ADEMCO Contact ID® Reporting with 10-digit
subscriber account number
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID® Reporting with 4-digit
If fewer than 24 digits entered, exit by pressing [✻]. To clear
entries from field, press ✻42✻. See backup reporting note for
field ✻41. If using the paging feature, enter the pager phone
number here.
✻
] as the fifth digit if a 4-digit account
✻
] if only 3 digits are used. To clear entries from
Enter the primary subscriber account number.
To clear entries from field, press ✻43✻.
Enter the secondary subscriber account number.
To clear entries from field, press ✻44✻.
This option allows the user to schedule a time driven message.
When activated the system will dial the phone number
programmed and deliver a voice message (custom words 72, 73
and 74). This option is only supported when the pager or follow
me feature is enabled in field ✻49 (option 6-9 or 10-13).
If using the Follow Me Reminder feature, enter the phone number
here. If fewer than 24 digits are entered, exit by pressing [✻]. To
clear entries from the field press ✻46✻.
The telephone message can be terminated (acknowledged) by
pressing any key on the telephone keypad. Pressing any key on
the local APX32EN keypad will terminate (acknowledge) both the
follow me and the local reminder announcements.
Note: The follow me reminder announcement will be terminated if any
other event requires the system to dial out or if an audible alarm
has occurred.
This option is used to enter the correct type of phone dialing
(pulse or tone), and to select the correct WATS line option for the
Central Station. This option is used to activate the Speaker Phone
option.
Note: If using pulse dialing, you must enter the numbers slowly in
order to allow the pulse dialer time to operate.
Enter ✻ as the 4th digit of ✻43 through ✻44, if 3+1 dialer
reporting is to be used. (For an explanation of these formats, see
the System Communication section of this manual.)
Notes: (1) The maximum number of alarm and alarm restore reports
during one armed period is determined by field ✻92.
(2) If Option 5 is selected a 10-digit account number must be
entered in Fields ✻43 or ✻44.
(3) Option 5 or 7 (ADEMCO Contact ID® Reporting) must be
selected for AAV.
- 23 -
APX32EN Installation and Setup Guide
Data Field Descriptions
✻49
✻50
Split/Dual Reporting
To Primary To Secondary
0 = All reports None, unless primary
fails, then all
1 = Alarms, Restore, Cancel* Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All reports All
To Primary To Paging Number
6 = All reports except Open/Close Alarms, Open/Close ‡,
Troubles
7 = All reports Alarms, Troubles
Will report Users 0, 5-8, and, if using wireless button-type
devices, will report the zone number of the arm or disarm
button 26-33. All other zones and users are not reported.
15-Second Dialer Delay (Burglary)
0 = no dialer delay
1 = provide 15-second delay of burglary alarm report
when armed away
‡
This field is used to select a reporting option as follows:
Enter: 0 - 5 when reporting to telephone receivers.
6 - 9 when reporting to a pager is desired.
10 - 13 when reporting to an auxiliary telephone receiver.
Pager Report Format
Options 6-9 send reports to the primary phone number, in a
format defined in Field ✻48, and send reports to a pager, which
has its phone number entered as the secondary phone number in
Field ✻42. The pager report is a 7-digit code, with optional 16digit prefix, in the following format:
AAAAAAAAAAAAAAAA-EEE–0NNN where:
AAA = Optional 16 digits for PIN number, etc. See Field ✻88 for full
description of these characters.
EEE = 3-digit Event Code as follows:
911 = Alarm (NN = zone number)
101 = Open, system disarmed (NN = user no.)
102 = Close, system armed (NN = user no.)
811 = Trouble (NN = zone no.)
0 = Always displayed before 3-digit user/zone no.
NNN = 3-digit user number or zone number, depending on the type of
event (EEE) that occurred.
Follow Me System Report Format
Options 10-13 send reports to the primary phone number, in a
format defined in Field ✻48, and sends voice message to the
secondary phone number entered in Field ✻42.
The message is a repeatable system status announcement. If the
manual paging option has been programmed in Field ✻87, the
message will repeat “system, system…..”.
The message can be terminated by pressing any key on the
telephone keypad.
If enabled, provides delay of burglary report to the central station,
and allows time for the subscriber to avoid a false alarm
transmission. The delay applies only to zone type 3 and 5 alarms
and not to zone type 24 alarms (silent burglary) or to 24-hour zone
types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm),
which are always sent as soon as they occur.
UL installations: must be 0 (no delay)
✻51
✻52
Periodic Test Report
0 = no test report 2 = weekly
1 = once every 24 hrs 3 = once every 30 days
First test Report Offset
0 = 24 hrs after exit program mode or download
Test report code entered in field ✻64 is sent.
Select the time for the first report following programming or
downloading.
1 = 6 hours after exit program mode or download
2 = 12 hrs after exit program mode or download
3 = 18 hrs after exit program mode or download
0 = Disabled 4 = 90 days
1 = 1 day 5 = 180 days
2 = 7 days 6 = 365 days
3 = 27 days Note: There is no local annunciation indicating that this
If disabled, selects Radionics, which uses hexadecimal 0-9, B-F
reporting. If enabled, selects Sescoa, which uses only numeric
reporting (0-9). Select 0 for all other formats.
If enabled, notifies the central station if an end user is not
operating their security system by sending a System Inactivity
report 654. The report will be sent only to the Primary phone
number and only if Contact ID® format was selected.
Note: The report will follow the ✻49 = 0 rules, no matter which selection
was made in ✻49.
report has been sent to the Central Station.
Field ✻55:
If AAV is enabled in *91, depending on Communication Channels programmed in *55, only the Reporting
options from the table below are available. They should be programmed as described in Dynamic Signaling
(field *77). If AAV is disabled in field *91, only specific reporting options are available.
If Follow me System or Pager features are selected, AAV will not be available even if enabled in *91 UNLESS option 5 is selected
in *55 (Radio only). If option 5 is selected in *55, AAV will be established on the primary channel because Follow me System
and Pager are not available on the radios audio channel.
The following tables show the only valid combinations of communication channels and reporting options. It is the responsibility
of the installer to ensure that a valid combination is programmed.
- 24 -