Ademco 8DLLYNXPLUS2 English Supplement

Important Information
The LYNX Plus Series control is equipped with a redesigned circui t board featuring relocated battery and communication port connections and redesigned ant ennas. Please refer to the figure below and to the Summary of Connections when making wiring connections and routing cabl es.
WIRE ROUTING TUNNELS
TIE-WRAP
POINT
TIE WRAP
TIE WRAP MOUNT
MOUNTING
HOOKS
TERMINAL
STRIP
NOTE
ENSURE ALL WIRING
IS ROUTED THROUGH
TELEPHONE
CONNECTION
WIRE STRAIN
RELIEF CLIP
SOUNDER
DISABLE
SWITCH
GSMVLP4G AUDIO CABLE CONNECTOR
LYNX Plus Wiring and Connection Overview
WIRE STRAIN RELIEF CLIP
BATTERY CABLE
POWERLINE CARRIER DEVICE CONNECTOR
1000-300-006-V5
UL INST ALLATIONS
5
Y
2
0
c.
www.honeywell.com/security
THE MINIMUM WIRE
SIZE USED FOR
TELEPHONE
INST ALLATIONS
MUST BE #26 GAGE
WARNING
TO PREVENT RISK OF
SHOCK, DISCONNECT
TELEPHONE LINE
A T TELECOM JACK
BEFORE SERVICING
THIS UNIT
EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL.
POWER SHUTDOWN NOTE: AT 6.0VDC THE SYSTEM WILL NOT OPERATE.
TO 24HR 110VAC
UNSWITCHED
OUTLET
EARTH
GROUND
INCOMING
TELEPHONE
LINE
PREMISES
TELEPHONE
HARD
WIRED
ZONE
2k OHMS EOLR
6-14VDC
120mA max.
BELL
NOTE
USE ONLY THE
K10145WH/K10145X10
OR K10145CN CLASS 2
TRANSFORMERS
PROVIDED
K10145WH/K10145X10 OR K10145CN PLUG-IN TRANSFORMER 9VAC, 25VA
8
POS
JACK
INCOMING
PHONE
LINE
ON
85dB
SIREN
DISABLE
SWITCH
THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS ANSI/NFP A 70 NATONAL ELECTRIC CODE AND NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2 (NATIONAL FIRE PR OTECTION ASSOC., BATTERY MARCH PARK, QUINCY, MA 02169). PRINTED INFORMATION DESCRIBING PROPER INST ALLATION, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PR OVIDED WITH THIS EQUIPMENT.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
LYNX PLUS SERIES ALSO COMPLIES WITH THE FOLLOWING: CANADIAN STANDARDS ASSOCIATION (CSA) C22.1, CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS.
1
EARTH
GROUND
RING
TIP
TIP
R
T
2
3
PHONE
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
RING
HAND
R
T
SET
5
4
THE LYNX PLUS SERIES CONTROLS ARE
COMPATIBLE WITH THE FOLLOWING
INTEGRAL RECHARGEABLE BATTERY PACKS:
P/N LYNXRCHKIT-SC P/N LYNXRCHKIT-HC
P/N LYNXRCHKIT-SHA
REPLACE EVERY FOUR YEARS
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM
HWZ
7
ZONE
SOUND
OUT
86
9
SOUNDERS
GSMVLP4G COMMUNICATIONS PORT
AC
AC
10
11
AC
THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
CIRCUIT
(ZONE)
02 - 25
ZT16
CONTROL UNIT
DELAY-SEC
STANDARD/HIGH-CAPACIT BATTERY CONNECTOR
SUPER HIGH-CAPACITY BATTERY CONNECTOR
POWERLINE CARRIER DEVICE CONNECTOR
GSMVLP4G AUDIO CABLE CONNECTOR
FCC ID: CFS8DLLYNXPLUS2 (LYNX PLUS SERIES) COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No. 5GBUSA-25623-AL-E RINGER EQUIVALENCE: 0.0043B
WARNING
SMOKE DETECTOR
MODEL DELAY-SEC
5806 10 seconds30 seconds
LYNX PLUS SERIES SUMMARY OF CONNECTIONS
1000-300-SOC-V
Corporate Center Drive, Suite 10 P.O. Box 9040, Melville, NY 11747
Copyright © 2012 Honeywell International In
Ê800-13012MŠ
800-13012 9/12 Rev. A
Loading...