Ademco 8DLLRS500 Installation Manual

This wireless siren/strobe is intended
SiXSIREN
OPEN
Enroll
This device can be enrolled and programmed either before or after installation.
*NOTE
NOTE
BETA DRAFT II’s 08/14/15
Gently twist the top of the
PLEASE GO TO THE BOTTOM OF THE LAST PAGE FOR FCC/IC AGENCY STATEMENTS
for use with Honeywell controls that support SiX™ series devices.
detector counterclockwise and the mounting bracket clockwise to separate them.
1. Set the Lyric Smart Controller in Programming Mode and go to Zone Programming. Select Add New, then Serial Number. Follow the controller’s instructions to begin enrollment.
2. Insert four 1.5V AA Lithium batteries (included) to activate the device and begin the enrollment process.
3. The SIXSIREN Green LED flashes rapidly during enrollment (up to 20 seconds*)
: Depending on the signal strength between the
device and the controller, the enrollment period may take longer than 20 seconds.
The device sends its unique MAC ID address (Serial Number) and Services information to the controller.
The controller registers the device and displays the transmitter data on screen.
4. Enrollment is confirmed when the Green LED is ON for 3 seconds and the controller chirps once.
5. Trigger the device tamper switch again to complete enrollment.
6. The device did not enroll in the system if:
The White LED flashes, the system chirps and the device powers down.
The Green LED flashes rapidly when the device is removed from the mounting bracket (the tamper switch is triggered).
To restart the enrollment process, ensure the system is in programming mode and activate the tamper switch.
: Once enrolled in a system, the Siren cannot be used with another controller until it is removed from the current controller. See the Controller’s instructions for details.
7. The device can also be manually enrolled. See
the Controller’s Programming Guide for details.
Program the SIXSIREN
Program
Mounting
NOTE
Test the SIXSIREN
Battery Replacement
insert
four new batteries of the same type and brand
NOTE
Do not mix old and new batteries,
battery types or manufacturers.
BATTERY CAUTION
Consult the Controller’s instructions for programming the device in the system.
Fault the device features to “Learn” the device “Services” in the control:
- Siren Chime Mode - Set sound level at the control:
1
Low = 35Db
High = 55dB
Life Safety
2
– select 85dB
- Cover tamper: The 10 minute tamper timer is reset every time tamper switch closed and opened or the siren cover is opened.
- Temperature sensing – range is 0° – 120° F (-18° – 49° C); accuracy ±3° F (1.67° C)
: Before mounting the device permanently, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength and adjust the device location and orientation as necessary.
The SIXSIREN can be mounted on the wall or on the ceiling.
The rear tamper breakout MUST be mounted to a stud, solid wood, or with a robust wall anchor.
35dB 1
55dB
85dB 2
1
Factory default
The SIXSIREN should be tested immediately after installation and at least once a year. Activate Test Mode remotely from the Controller (see Controller’s manual for details).
Test Mode tests the sounder and LED:
- Sounder – the Burglary warble tone will sound for 3 seconds.
- LED – the White LED strobe will flash for 15 seconds.
Twist the front cover counterclockwise and
separate it from the mounting bracket.
Remove the batteries, wait 10 seconds and
Recommended replacement batteries:
- 1.5V AA Lithium Batteries [Non-Rechargeable]
- AA Alkaline batteries can be used, but battery
life will be significantly reduced.
:
Reattach the front cover and twist clockwise to
secure it in place.
Do not recharge, disassemble, heat above 212 F (100 C) or incinerate. Dispose of used batteries properly. Keep away from children.
: Risk of fire, explosion and burns.
.
Loading...
+ 2 hidden pages