Ademco 8DLLMD500 Installation Manual

This wireless passive infrared motion sensor is intended for use with Honeywell controls that support
Mounting Location
Mounting Options
[A]
[B]
Note
PRELIMINARY DRAFT IIs – 01/12/15
PLEASE GO TO THE BOTTOM OF THE LAST PAGE FOR FCC/IC AGENCY STATEMENTS
SiX™ series devices.
The optimal range is obtained at a mountin h
A
llow a clear line-of-sight
to all areas to protect.
Do not directly face windows.
Avoid close proximity to m
oving machinery, fluorescent lights, an h
eating/cooling sources.
g
.
d
For use in applications
with pets up to 80 pounds (36 kilograms).
The RF6PIR can be mounted on the wall or in corners:
The rear tamper plate
UL requirements: TBD
RF6PIR permanently, conduct Go/No Go tests (see control’s instructions) to verify adequate signal strength and adjust the device location and orientation as necessary.
= Wall mounting
oles.
h
= Corner mounting
oles.
h
MUST be mounted to stud, solid wood, or with a robust wall anchor.
: before mounting the
a
Enroll the RF6PIR
The RF6PIR can be enrolled and programmed before or after installation.
Note
Programming RF6PIR Services
Walk Test the RF6PIR
Note
disarmed
Press down on the top latch and separate the front and back covers.
Set the Lyric Smart Controller in Programming Mode.
Remove the RF6PIR battery tab to activate and begin the enrollment process.
The green LED beneath the battery flashes during enrollment (about 8 seconds) and the control beeps (TBD).
The device sends the device MAC ID address and Services information to the control. The control registers the device and displays the transmitter data on screen.
Enrollment is confirmed when the RF6PIR LED is ON for 3 seconds [and the control
beeps TBD].
If the sensor is not successfully enrolled during the enrollment period, the LED turns off and the device powers down. Activate a tamper to restart the enrollment process.
: Once enrolled in a system, the sensor cannot be used with another control panel until it is removed from the current control panel. See the Control’s instructions for details on removing devices.
Fault device features to “Learn” device “Services” in the control:
- Cover and Wall tamper switches
- Selectable Pet Immunity –
Off or up to 80 lbs (36 kg)
- Temperature sensor; accuracy ±3°F
Consult the Lyric Smart Controller’s instructions for programming the device in the system.
After power up and enrollment, activate the Test Mode with the control (see control’s instructions) or use the Flashlight Feature. Test period.
: the system must be in
the 10 minute Test mode to begin.
Walk through the detection area and observe the LED.
Test Mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal operation mode.
To restart the 10 minute Test Mode, use the flashlight feature (see the following section).
mode for