INSTALLATION INSTRUCTIONS
SiXOCC
Wireless Occupancy Sensor
The Honeywell Home SiXOCC Occupancy Sensor is a wireless device used with controllers that support Honeywell Home’s SiX™ series devices.
NOTE: Lights controlled via Z-Wave devices have not been evaluated by ETL.
SECURITY SENSOR
The security sensor reacts to movement and tells the panel to react based on the control’s programming.
1. Typically, it’s programmed as an interior follower.
2. LED walk test mode indication, one for the intrusion detection and the other for the occupancy detection. (See testing for more information.)
3. Up to 40 pounds’ pet immunity.
If the system is Armed, the control goes into alarm.
If the system is disarmed it turns the light on (or adjusts
the thermostat) based on the explanation below.
OCCUPANCY SENSOR
When the control is disarmed (deactivated), the occupancy sensor switches to occupancy mode and reacts to the user’s programming in the control. Logic is as follows:
General Operation
1. First detection activates turns on the lights and/or adjusts the temperature.
Any small movement, such as the turning a page of a book or swiping a tablet will continue to keep the light on and temperature at the programmed levels.
2. When it stops detecting movement for a pre-defined time-period defined by the user/ installer, it will turn off the light and increase or lower the temperature until movement is detected again.
MOUNTING LOCATION
The optimal range is obtained at a mounting height of 7’ 6” (2.3m).
Allow a clear line-of-sight to all areas to protect.
Do not directly face windows.
Avoid close-proximity to moving machinery, fluorescent lights, and
heating/cooling sources.
For use in applications with pets up to 40 pounds (36 kilograms).
In Applications with Animals:
Mount with the center of the device at 7.5 feet (2.3m)
Mount where pet cannot come within 6 feet (1.8m) of the sensor
by climbing on furniture, stairs, boxes or other objects.
Test each installation to determine exact level of animal immunity; levels vary based on environmental differences and the amount of heat radiated
by an animal.
Daylight Savings
Daylight Savings sensor detects the lighting level in the room.
1. Turns on lights only if the daylight is below a certain level and tries to keep the same amount of light in the room.
2. Once the daylight has been evaluated, the SiXOCC decides when to turn on the light. Depending on the level the light turns on to 25%, 50%, 75%, and 100%.
Example: If the natural room light level is at 100%, then
the light does not turn on; at 0% natural light, the light turns on to 100%.
3. The level the light turns on can be set to a certain % (vs. slowly increasing the light level). For example, any natural light level decrease turns on the light to 100%.
Programmable to turn the feature on (described above), or off (when it detects any movement).
1
MOUNTING OPTIONS
NOTE: Once enrolled in a system, the sensor cannot be
4. Enrollment is confirmed when the LED is ON for 3 seconds.
Signal Strength:
After enrolling, verify adequate signal strength by conducting Go/No Go tests (see the controller’s instructions) with the device in its intended mounting location. Adjust the device location and orientation as necessary.
The SIXOCC can be mounted on the wall or in corners:
[A] = Wall mounting holes.
[B] = Corner mounting holes.
• The rear tamper plate MUST be mounted to a stud, solid wood, or with a robust wall anchor.
ENROLL THE SIXOCC
used with another controller until it is removed from the current controller. See the Controller’s instructions for details.
Press down on the top latch and separate the front and back covers.
1. Put the controller in Programming Mode and when prompted:
2. Remove the battery tab to activate and begin the enrollment process. Or, if powered, press the tamper.
3. The green LED beneath the batteries flashes (up to about 20 seconds*) during enrollment. The device sends its unique MAC ID (Serial Number) and Services information to the controller.
NOTE: Enrollment time varies depending on the signal strength between the device and the controller.
NOTE: If the sensor is not successfully enrolled during the enrollment period, the LED turns off and the device enters a sleep mode. Activate a tamper or remove and reinsert the batteries to restart the enrollment process.
NOTE: Pet Immunity is selectable: Off or Up to 40 lbs (36 kg).
Sensor Location Feature: To verify the location of each SiX device in an installation, enter programming mode and select a SiX device. The device LED lights. Select it again to turn the LED off or select the next device to locate.
Range of 1-4 bars (green); should be minimum 1 green bar for the Zone being programmed. Four red bars indicate poor signal strength; the device should be relocated. See the Controller’s instructions for bar indication signal strength values.
Icon Description Signal Strength
Four Green Bars
Three Green Bars
Good
Two Green Bars
One Green Bar