Ademco 8DL6160VPADT2 Users Manual

K14804V1 6/08 Rev. B
FCC / IC STATEMENTS ARE ON PAGE 4
6160VPADT
6160VPADT
6160VPADT6160VPADT
SafePassTM Remote Touchpad
INSTALLATION and SETUP GUIDE
GENERAL INFORMATION
The 6160VPADT is an addressable remote Voice Touchpad with a built-in Proximity Reader, designed for use with ADT control panels. This Touchpad provides the following features:
Backlit Display (programmable as permanent on some controls)
Continuously Backlit Touchpad Keys
Programmable Function Keys
Built-in Sounder
Arm/Disarm via Prox Tag
Voice Chime
Voice Status
Message Center
Supervised by control panel (if supported).
Installation Notes
The Touchpad can only be used on addressable
systems and cannot be used on Control Panels that use Keypad Address 31. The Touchpad must be set for address 00-30. When used with the Safewatch
Pro/Security Manager 3000 control panels, address 16 must be assigned to the first Touchpad. Additional Touchpads must be assigned to addresses 17 – 23. (Refer to Setting the Touchpad Options.)
The Prox reader utilizes an additional keypad address, which must be enabled at the Control Panel (see control panel installation instructions for allowable keypad addresses).
The partition used for the Touchpad, Prox Reader, and User Code must be the same.
The Prox Tags will only arm and disarm one partition. The Prox Reader cannot be used to perform global arming operations.
Presenting a Prox Tag is functionally equivalent to entering a 4 digit user code.
Voice Chime should only be enabled when used with control panels that support the "chime by zone" mode (e.g., SAFEWATCH PRO/SECURITY MANAGER 3000). This mode must be enabled at the control panel. Refer to the control panel's installation and setup guide for information on how to program the chime mode.
with Prox Reader
6160VPADT QUICK SETUP
The following steps can be used to install the 6160VPADT Remote Touchpad and Prox Reader. For more detailed information regarding installation, programming and operation, refer to Detailed Information and Installation.
When installing wiring between the Touchpad’s terminal block and the terminal block on the Control Panel, connect only the red and black Aux. Power connections at the Touchpad initially, and follow the step-by-step instructions for addressing the Touchpad and Prox Reader.
Step Action
1. Connect red and black wires only to touchpad.
2. Program the keypad address. (Safewatch Pro 3000 = 16)
3. Press * to save.
4. At the “VOICE CHIME” prompt, press *.
5. At the “ADDITIONAL CON” prompt, enter “0” if this is the Primary Voice Touchpad, or “1” if this is an additional Voice Touchpad.
6. Press * to save.
7. The “Prox Addr? XX” will be displayed. Enter an unused keypad address.
8. Press * to save.
9. Power down the panel.
10. Connect the green and yellow wires.
11. Power up the panel.
12. In panel programming, configure the Prox Reader Address that you just programmed as a keypad. a. If you are using a Vista-128, Vista-50 or like panels, go to device programming and program the Prox Address
as an “Alpha Console.” b. If you are using a Safewatch Pro 3000, use an address between 17 and 23. Go to location *190 to *196 and enter the partition in which the Touchpad is being used.
13. Exit programming.
14. Enroll the Prox Tag by programming a new “User” code with the four-digit serial number located on the tag’s packaging.
STEP-BY-STEP INSTALLATION INSTRUCTIONS
Touchpads can be surface mounted using drywall anchors or to a single- or double-gang electrical box.
1. Remove the case back by pushing in the two "snaps" along the Touchpad’s bottom edge and pulling the case apart. See diagram above.
2. Route wiring from the control panel through the case back openings or the knockouts located on the sides.
3. Mount the case back to a wall or electrical box.
Do not connect the ECP Data In or Data Out until directed to do so. If the Touchpad’s Prox Reader detects the presence of ECP Data In and Out connections during address programming mode, it will exit to “normal” mode.
4. Wire directly from the Touchpad’s terminal block
to the terminal block on the control panel. (Refer to the Wiring Table.) Connect only the red and
black Aux. Power connections at the Touchpad. Use only 16-24 AWG wire.
Wiring Table
Touchpad Control Panel Wire Color
G Data In Green
– Aux Pwr (GND) Black
+ + Aux. Pwr (POS) Red
Y Data Out Yellow
5. Re-attach the Touchpad to the case back.
6. Remove clear protective film from LCD display.
SETTING THE TOUCHPAD OPTIONS
The procedures that follow are used to set the Touchpad address, voice chime mode, and additional console modes.
Setting the Touchpad Address
When used with the Safewatch Pro/Security Manager 3000 control panels, address 16 must be assigned to the first Touchpad. Additional Touchpads must be set at 17 - 23 and must be enabled additionally in control programming (fields *190 - *196).
The Touchpad addresses being used for the Touchpad and the Prox Reader must be enrolled in the control panel.
Swiping a Prox Tag when the system is in programming mode may cause programming fields to receive invalid entries.
The Touchpad may be set for address 00-30 or for non­addressable mode (31). The default Touchpad address is 31. For valid address settings for your Touchpad, refer to the control panel's Installation & Setup Guide.
Notes:
If installed with an older non-addressable panel
(using address 31), the prox feature cannot be used.
If unable to enter the address mode, power down,
power up, and try again.
If 10 seconds pass with no key entry, the Touchpad
automatically exits the address mode. You must power down, power up, and start the address mode again.
The Touchpad will not enter the address mode if the
control panel is in programming mode.
1. Apply power to the Touchpad.
2. Within 60 seconds of applying power to the Touchpad, press and hold down the [1] and [3] keys at the same time for 3 seconds. The current Touchpad address will be displayed.
3. Press "00". The current address is cleared.
4. Enter desired two-digit Touchpad address.
5. Press [] to accept the displayed address and enter the Voice Chime Mode. "VOICE CHIME" is displayed along with the selected mode "1" or "0".
Setting the Voice Chime Mode
Setting Voice Chime mode off does not effect the voice status or alarm annunciation.
1. Press [1] to set the Voice Chime mode on or press [0] to set the Voice Chime mode off.
2. Press [] to save the displayed Voice Chime mode and enter the Additional Console Voice Touchpad mode. "ADDITIONAL CON" is displayed along with the selected mode "1" or "0".
Setting the Additional Console Mode
The Additional Console mode must be set for all Touchpads being used.
1. Set the Touchpad Additional Console mode as follows: a. On the Primary Touchpad, press [0] to set the
Additional Console mode to NO.
b. On any secondary Touchpads, press [1] to set Additional
Console mode to YES.
2. Press [] to save the mode and enter Prox Reader Address Mode.
Setting the Prox Reader Address
1. After exiting “additional console” mode, the Prox Reader will begin communicating with the Touchpad, and the Touchpad will display “Prox Addr? XX” on the first line.
1. XX = the current ECP Address. The Prox Reader address cannot be the same as the Touchpad address. Select an address between 01 and 30 (default = address 23.)
2. Make sure you enable the prox reader address as a keypad in the control panel.
2. Set the current address to "00": Press [0] to clear the current "tens" digit. The cursor moves to the "ones" digit position. Press [0] to clear the current "ones" digit. The cursor moves back to the "tens" digit position.
3. Enter the appropriate address: Enter the proper "tens" digit of the address. The cursor moves to the "ones" digit position. Enter the proper "ones" digit of the address.
4. Press the [*] key to save the entry. The Touchpad will beep three times confirming the address is accepted, and the first digit of the address will flash. You can re-enter the address if desired.
5. Power down the Touchpad.
6. Remove the case back.
7 Connect the green and yellow data in and data out wires
at the control panel. Once connected, any Touchpad not enabled in the control at that point will be blank.
8. Re-attach the Touchpad to the case back.
9. Install the Prox Reader location labels on the Touchpad.
(Refer to Figure 1.)
- 2 -
Loading...
+ 2 hidden pages