Remote Touchpad with Prox Reader
INSTALLATION and SETUP GUIDE
GENERAL INFORMATION
The 6160VPADT is an addressable remote Touchpad designed for use with ADT control panels. This Touchpad provides the following features:
Backlit Display
Programmable Function Keys
Built-in Sounder
Arm/Disarm via Prox Tag
Voice Chime
Voice Status
Message Center
Notes:
When used with the Safewatch Pro/Security Manager 3000 control panels, address 16 must be assigned to the first Touchpad. Additional Touchpads must be assigned to addresses 17 – 23. Refer to Setting The Touchpad Options.
Touchpad keys are continuously backlit for convenience.
Permanent display backlighting is an option on some
controls (refer to the control panel’s instructions for details).
Voice Chime should only be enabled when used with control panels that support the "chime by zone" mode (e.g., SAFEWATCH PRO/SECURITY MANAGER 3000). This mode must be enabled at the control panel. Refer to the control panel's installation and setup guide for information on how to program the chime mode.
Use only zone descriptors supported by this Touchpad. If using zone descriptors not supported by this Touchpad, you must turn voice status and voice chime off. Table 1 is a list of applicable zone descriptors and index entries. Refer to the control panel’s installation and setup guide for information about how to program zone descriptors.
TOUCHPAD DISPLAYS AND LEDS
The Touchpad provides a two-line alphanumeric display and custom zone descriptors. The following table identifies the Touchpad’s LEDs and associated functions:
LED Function
ARMED Lights red when the system is armed in any mode.
READY
MESSAGE
Lights green when the system is "ready" to be armed.
Flashes red when message waiting or lights (steady) when in record mode.
PROGRAMMABLE FUNCTION KEYS The Touchpad's programmable function keys [A, B, C] are
normally used for Touchpad panic functions, but they can be programmed for other special functions instead. If they are programmed for other special functions, the associated Touchpad key pairs still provide the respective panic alarm (if programmed). Refer to the control panel’s Installation & Setup Guide for details.
Function
Keys
Equivalent Key Pairs
A [1] and [*] B [*] and [#] C [3] and [#] D NONE
Function keys must be held down for at least 2 seconds to activate the programmed function.
If functions other than panics are assigned to the
programmable function keys, programmed panics must be initiated by pressing the programmed key pair.
FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function symbols (i.e., fire, police, personal emergency, etc.) is provided. These labels can be placed on or next to the keys to identify each key's function for the end user (as determined by the capability and programming of the control panel; refer to the installation and setup guide for the control panel).
A
ARMED
B
READY
MESSAGE
C
MIC
1
RECORD
4
7
STATUS
INSTANT
OFF
READY
2
VOLUME
5
8
0
3
PLAY
BYPASS
TEST
6
CHIME
9
CODE
#
FUNCTIONVOICE
SIDE VIEW
STAY
AWAY
D
(Remove case back by pushing up the 2 "snaps" along
the keypad's bottom edge and pulling the case apart.)
MOUNTING RELEASE SNAPS
WIRING AND INSTALLATION
Touchpads can be surface mounted using drywall anchors or to a single- or double-gang electrical box.
1. Remove the case back by pushing in the two "snaps" along the Touchpad’s bottom edge and pulling the case apart. See diagram above.
2. Route wiring from the control panel through the opening in the case back.
3. Mount the case back to a wall or electrical box.
Do not connect the ECP Data In or Data Out until directed to do so. If the Prox Reader detects the presence of ECP Data In and Out connections during address programming mode, it will exit to “normal” mode. The touchpad addresses being used for the touchpad and the Prox Reader must be enrolled in the control panel.
6160vADT-50-001-V0
4. Wire directly from the Touchpads terminal block to the terminal block on the control panel. (Refer to Wiring Table). Connect only the red and black Aux. Power connections at the control panel.
Wiring Table
Touchpad Control Panel Wire Color
G Data In Green
– Aux Pwr (GND) Black
+ + Aux. Pwr (POS) Red
Y Data Out Yellow
5. Re-attach the Touchpad to the case back.
6. Remove clear protective film from LCD display.
SETTING THE TOUCHPAD OPTIONS
The procedures that follow are used to set the Touchpad address, voice chime mode, and additional voice Touchpad mode.
Setting the Touchpad Address
When used with the Safewatch Pro/Security Manager 3000 control panels, address 16 must be assigned to the first Touchpad. Additional Touchpads must be set at 17 - 23 and must be enabled additionally in control programming (fields *190 - *196).
The Touchpad may be set for address 00-30 or for non­addressable mode (31). The default Touchpad address is 31. For valid address settings for your Touchpad, refer to the control panel's Installation & Setup Guide.
Notes:
If unable to enter the address mode, power down, power
up, and try again.
If 10 seconds pass with no key entry, the Touchpad
automatically exits the address mode. You must power down, power up, and start the address mode again.
The Touchpad will not enter the address mode if the
control panel is in programming mode.
1. Apply power to the Touchpad.
2. Within 60 seconds of applying power to the Touchpad,
press and hold down the [1] and [3] keys at the same time for 3 seconds. The current Touchpad address will be displayed.
3. Press "00". The current address is cleared.
4. Enter desired two-digit Touchpad address.
5. Press [] to accept the displayed address and enter the
Voice Chime Mode. "VOICE CHIME" is displayed along with the selected mode "1" or "0".
Setting The Voice Chime Mode
Setting Voice Chime mode off does not effect the voice status or alarm annunciation.
1. Press [1] to set the Voice Chime mode on or press [0] to
set the Voice Chime mode off.
2. Press [] to save the displayed Voice Chime mode and
enter the Additional Console Voice Touchpad mode. "ADDITIONAL CON" is displayed along with the selected mode "1" or "0".
Setting the Additional Console Mode
The Additional Console mode must be set for all voice Touchpads being used.
1. Set the voice Touchpad Additional Console mode as follows:
a. On the Primary voice Touchpad, press [0] to set the
Additional Console mode to NO.
b. On any secondary voice Touchpads, press [1] to set
Additional Console mode to YES.
2. Press [] to save the mode and enter Prox Address Mode.
Setting the Prox Reader Address
1. After exiting “touchpad address” mode, the prox reader will begin communicating with the touchpad, and the touchpad will display Prox Addr? XX on the first line.
XX = the current ECP Address.
2. Enter an appropriate ECP address. Set the current address to "00": Press [0] to clear the current "tens" digit. The cursor moves to the "ones" digit position. Press [0] to clear the current "ones" digit. The cursor moves back to the "tens" digit position.
3. Enter the appropriate address: Enter the proper "tens" digit of the address. The cursor moves to the "ones" digit position. Enter the proper "ones" digit of the address.
4. Press the * key to save the entry. The keypad will beep three times confirming the address is accepted, and the first digit of the address will flash. You can re-enter the address if desired.
5. Power down the Touchpad.
6. Connect the green and yellow data in and data out wires
at the control panel. Once connected, any touchpad not enabled in the control at that point will be blank.
ENROLLING PROX TAGS
Each prox tag is enrolled as a “User” in the alarm system. When enrolling the tags, the last four digits of the tag’s serial number should be used as the User Code. Refer to the controls User Guide for instructions on programming user codes. When programming is complete, test the system to ensure that each prox tag arms and disarms the system as specified.
VIEWING THE TOUCHPAD ADDRESS
During normal operation, press and hold down the [1] key and [3] key at the same time for about 3 seconds. The current address is displayed. No key entry is allowed. Press any key to exit or wait 10 seconds to exit the viewing mode.
SPECIFICATIONS
Physical: 5-5/16"H x 7-3/8"W x 1-3/16"D Display: 2 x 16 Alpha-Numeric
Supertwist LCD (backlit)
Sounder: Speaker Electrical:
Voltage: +12VDC Current: 190mA (ARMED LED lit, LCD backlight
and sounder on) reduces to 60mA when panel is operating in standby mode (backlight off).
- 2 -