• Provides a nominal range of 200 feet for RF transmitters (some transmitters have a shorter range).
• Supports RF jam detection when the receiver is enabled.
• Capable of sending status signals (Armed, Ready, etc.) to bi-directional units such as 5804BD, 5804BDV and
5828/5828V.
UUUU
The following 5800 series transmitters are not intended for use in UL installations: 5802, 5804, 5804BD, 5804BDV, 5804E,
LLLL
5814, 5819, 5819BRS, 5819WHS, and 5828/5828V.
INSTALLING THE 6160RF
Locate the 6160RF in an area and at a height where
it is convenient for user operation. The 6160RF must
be at least 10 ft from the control panel to ensure
proper operation of the RF receiver.
Mounting and Wiring
The 6160RF has terminal blocks for connection to
power and data wires. Removing the keypad’s case
back provides access to the terminal blocks.
The 6160RF can be surface mounted directly to
walls, or to a single- or double-gang electrical box.
Follow these steps to mount and wire the keypad:
1. Push the two case release snaps at the bottom of
the keypad with the blade of a medium
screwdriver (this will push in the release snap),
then pull that side of the case back away. Insert
the screwdriver in the side of the keypad
(between the front and back case) and gently
twist to release the side locking tab. Repeat for
the other side. Refer to Figure 1 for location of the
case back release snaps and locking tabs.
Pass the wiring from the control panel through
2.
the opening in the case back. (see the control
panel’s instructions for proper run lengths.)
a. If surface wiring is being used, wiring may be
routed through the top or the bottom left-side
breakout in the case back. The breakouts must
be punched out using a screwdriver before
mounting the case back.
b. If desired, wires may be strain-relieved to the
wire tie point on the inside of the case back
with a tie wrap (not supplied).
3. Mount the case back to a wall or to an electrical
box using the 25mm-long self-tapping screws
supplied (mollies for drywall are not supplied).
4.
Connect the power and data wires from the
control panel to the terminals on the 6160RF as
indicated in Figure 2 and Table 1.
ARMED
READY
NOTE:
TO REMOVE REAR COVER
PUSH IN THE TWO MOUNTING
SNAPS LOCATED ALONG THE
BOTTOM OF THE KEYPAD
AND LIFT COVER UP.
Figure 1. Removing the Case Back
MOUNTING
RELEASE
SNAPS
LOCKING
TAB
6160RF-003-V1
+
Y
G
+
+++
WIRING TERMINALS
(TO CONTROL PANEL)
Figure 2 - 6160RF Wiring Details
6160RF-002-V1
Table 1 - Wiring Table
Keypad Control Panel Wire Color
G▼ (Data Out)
- -Aux Pwr (GND) Black
+ +Aux Pwr Red
▲Y (Data In)
Data In Green
Data Out Yellow
APPLICATION GUIDELINES FOR THE 6160RF
Use the following guidelines when planning an installation:
If… And… Then…
This is the only
transceiver on
the system,
You want to use both
the receiver and
transmitter function
on a single-partition
system,
• Set the keypad to a device address assigned to the desired partition.*
• Enable the receiver.
• Program a system House ID in the control panel (this will enable the transmitter
function).**
• Set the wireless devices that will communicate with this 6160RF to the same
system House ID.
5. Reattach the keypad to the mounted case back.
Attach the top of the keypad first, and then
press the bottom section down until it snaps
into place securely.
6. Peel off protective film on the LED panel and
install the keypad labels as required.
There is another
receiver or
transceiver on
the system,
You want to use only
the transmitter
function on a second
partition,
• Set the keypad to a device address assigned to the desired partition.*
• Disable the receiver.
• Program a DIFFERENT House ID in the 6160RF than is programmed in the control
panel.*/ **
• Set the wireless devices that will communicate with this 6160RF to the same
House ID as the 6160RF.
You want to use only
the transmitter
function on a singlepartition system,
• Set the keypad to a device address assigned to the Partition 1.
• Disable the receiver.
• Program a House ID in the 6160RF that matches the system House ID
programmed in the control panel.*
• Set the wireless devices that will communicate with this 6160RF to the same
House ID.
Notes:
* On VISTA-40 panels and above, wireless keypads (e.g., 5804BD) can only be used on a single partition. This
partition is programmed in field 1*48, and must match the partition assigned to the 6160RF. Wireless keys can
be used on more than one partition, using a House ID programmed in the 6160RF and the devices. In this case,
the wireless keys must be assigned to the same partition as the 6160RF.
** On VISTA-20P panels, the 6160RF will use the House ID programmed in the panel for the partition to which
it is assigned. Wireless keypads can only be used on Partition 1.
PROGRAMMING THE 6160RF
Refer to the following procedure to program the 6160RF:
STEP DESCRIPTION
1. Enter the program mode by pressing the [1] and [3] keys simultaneously
for a few seconds within 60 seconds after applying power.
2. (Keypad Address) Enter the two-digit keypad address. Press the [✻] key
to continue.
Notes: (1) Refer to the control panel’s installation instructions for the
(2) On the VISTA-40 and above the 6160RF’s partition assignment must
3. (Receiver Enable) Enter [1] to enable, or [0] to disable Receiver. Enable
the receiver if RF transmitters or wireless keypads are programmed into
the control and no other receivers are enabled. Press the [✻] key to
continue.
acceptable keypad addresses.
match the RF keypad partition assignment programmed in field
(1*48).
- 2 -
DISPLAY
CON ADDRESS
CON ADDRESS = XX
CON ADDRESS CON ADDRESS
RECEIVER
RECEIVER
RECEIVERRECEIVER
ON [0
ON [0
=
OFF]
ON [0ON [0
OFF]
OFF] OFF]
XX
XX XX
CHOICES
00-31
1= ON
0 = OFF
A
STEP DESCRIPTION DISPLAY CHOICES
4. (Receiver Address) If receiver is enabled, enter the two-digit receiver
address. (00-30).
Note: Refer to the control panel’s installation instructions for the acceptable
receiver addresses.
Press the [✻] key to continue.
5. (House ID) This prompt will only appear if the receiver is disabled. If the
receiver is enabled the 6160RF will use the House ID programmed in
the panel. Refer to Application Guidelines section when selecting a
House ID.
To program a House ID: Enter 01-31.
To disable the transmitter: Enter 00
Note: Each device that will receive status from the 6160RF must be set to the
same House ID as the 6160RF (refer to Application Guidelines section).
Press the [✻] key to continue.
(Enable High Security Mode) Enter [1] to select High Security Mode.
6.
Note: If the High Security mode is enabled, the 6160RF will only recognize
encrypted devices.
commands both encrypted and non-encrypted devices.
Press the [✻] key to continue.
7. (Disable High Security Devices) Press the [✻] key to skip this prompt
and exit Program Mode.
Notes: (1) The [✻✻✻✻] key must be pressed several times in order to save the
(2) If you need to disable encrypted devices, refer to the Disabling High
ACTIVATING HIGH SECURITY DEVICES
This following procedure should be followed if using High-Security (encrypted) devices.
STEP DESCRIPTION
Follow the normal procedure for programming the device into the control panel (refer to the Installation
1.
Instructions for the device that you are programming). Exit out of Programming Mode.
2. Put the control panel in Go/ No Go Test mode. (See the Installation Guide for the panel being installed.)
Follow the instructions supplied with each wireless device to enroll the device in High-security mode. After each
3.
device is enrolled the 6160RF will momentarily display “SECURITY DEVICE” along with the device number and
its serial number.
Note: The 6160RF will support a maximum of 8 devices. If you attempt to enroll additional devices the keypad will display
programmed data.
Security Devices section.
“EXCEEDED NUMBER” “ALLOWED DEVICES”.
If this mode is disabled, the 6160RF will process
REC ADDRESS
REC ADDRESS= XX
REC ADDRESSREC ADDRESS
HOUSE ID
HOUSE ID = XX
HOUSE ID HOUSE ID
HIGH SECURITY
HIGH SECURITY
HIGH SECURITYHIGH SECURITY
OFF [1
OFF [1]]]] = ON
OFF [1OFF [1
DISABLE HS DEV?
DISABLE HS DEV?
DISABLE HS DEV?DISABLE HS DEV?
=
YES
NO [1
NO [1]]]]
NO [1NO [1
YES
YESYES
ON
ONON
XX
XX XX
XX
XXXX
00-30
00-31
1= Enable
0 = Disable
1= YES
0 = NO
DISABLING HIGH SECURITY DEVICES
This mode gives you the ability to disable high security on all wireless keys that have been enrolled in the
6160RF. This is particularly useful if a user loses a wireless key.
Once high-security (encrypted) devices have been disabled, they will only operate if the 6160RF is set to listen to both
encrypted and non-encrypted devices (programming step 6, above). To completely disable the devices, they must be deleted
!
from the control panel.
STEP DESCRIPTION DISPLAY CHOICES
1.
2.
3.
fter the keypad has been powered for at least 60 seconds hold
down the [1] and [3] keys at the same time for 3 seconds. The
current keypad address will be displayed. (You cannot change the
keypad’s address at this point.) Press the [✻] key to continue.
(Delete High Security Devices) Press the [1] key to remove all highsecurity (encrypted) devices. Press the [✻] key to continue.
If YES was selected in Step 2 the unit will display a confirm
request to delete the stored high security device. Press the [1] key
to accept, followed by the [✻] key to exit the programming mode.
- 3 -
CON ADDRESS
CON ADDRESS=XX
CON ADDRESSCON ADDRESS
DISABLE HS DEV?
DISABLE HS DEV?
DISABLE HS DEV?DISABLE HS DEV?
NO [1
NO [1]]]]=YES
NO [1NO [1
ARE YOU SURE?
ARE YOU SURE?
ARE YOU SURE?ARE YOU SURE?
NO [1]
NO [1]=YES
NO [1]NO [1]
YES
YESYES
YES
YESYES
XX
XXXX
00-31
1= YES
0 = NO
1= YES
0 = NO
TROUBLESHOOTING
The error messages listed in the following table cause the 6160RF to produce a single ding tone. The table
describes the error messages and the corrective actions.
Display Probable Cause Corrective Action
Low Bat (with
Low battery in the wireless device.
zone no.)
Open Ckt No data is being received from the control panel.
Check 100
Check 1xx*
1. The control panel does not see the 6160RF
Receiver, or the Receiver is not functioning.
2. Another device on the keypad terminals is not
communicating to the control panel.
*xx= the device address of the receiver.
SPECIFICATIONS
Physical: 5-3/8” H x 7-3/8” W x 1-1/4” D
(137mm x 187mm x 32mm)
Current: Standby 50mA
Wiring: Refer to Table 1
Range: 200 ft (60.9 m) nominal
Frequency: 345 MHz
Display: 2 x 16 alphanumeric supertwist LCD, backlit
Sounder: Tone Generator Integrated Circuit. (fire alarm is loud pulsing tone;
FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE CONTROL PANEL BEING
INSTALLED IN CONJUCTION WITH THIS DEVICE.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the InstallationInstructions or User's Manual. Unauthorizedchangesor modifications could void the user's authorityto operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCCrequires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions,may cause interference to radio and television reception.It has been type tested and found to complywith the limits for a Class B computing device in accordancewith the specifications in Part 15 of FCC Rules,which are designed to provide reasonable protection against such interferenceina residential installation. However,there is no guarantee that interferencewill not occur ina particular installation.If this equipment does cause interferenceto radio or televisionreception, which canbe determined by turning the equipment off and on, the user is encouraged to try to correct the interference byone or more of the following measures:
• Ifusing an indoor antenna, have a quality outdoor antenna installed.
• Reorient thereceiving antenna untilinterference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from anywire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that itand the radio or television receiver are on different branch circuits.
• Consult the dealer or an experiencedradio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digitalapparatus complies with CanadianICES-003.Cet appareil numérique de laclasse Best conformeà la norme NMB-003 duCanada.
FCC/IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS210of IndustryCanada. Operation is subject to the following two conditions: (1)This device maynotcause harmful interference, and (2) This device must accept any interference received, including interference that maycause undesired operation.
Cet appareil est conformeà lapartie 15 des règles de laFCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1)Cet appareil ne doitpas causer d' interferences nuisibles. (2) Cet appareildoit accepter toute interference reçue y compris les interferences causant une receptionindésirable.
WARRANTY INFORMATION
For the latest warranty information, please go to: