ADEMCO 6152RF Keypad / Transceiver – Installation and Setup Guide
Fixed Addressable Keypad/Transceivers for use with Honeywell Control Panels; incorporates normally-open relay output with the functions of a medium 16 zone RF Receiver and a 5800 Transmitter module.
Programmable to support the following :
- Bi-directional 5828/5828V wireless keypads and wireless
keys (e.g., 5804BDV, 5834-4, etc.)
- Up to eight button-type wireless keys locally (programmed directly into the keypad), without occupying control panel zones
- Up to 16 5800 series wireless zones programmed into any supported control panel
- Wireless keys with high security mode enabled
To activate Function keys, press and hold key for at least 2 seconds; key pairs are activated immediately.
Table 1 – Programmable Function Keys
A or
B or and
C or and
D
Note: See the control’s instructions for
details on programming the Function keys for panic alarms or other special functions (i.e., macros).
and
1. OPEN
1
2
AWAY
BYPASS
STAY
CHECK INSTANT CANCELED
Sounder
6152RF-KEYPAD-LBLD-032613
ALARM FIRE
Table 2 – Settings Ke
Settings Ke
Press for 2 Seconds
Press for 2 Seconds and during the Display Test,
press and hold
for 3 Seconds
and
Control Panel
NO NIGHT AC
TESTPHONE NOT READY CHIME BAT
Programmable Function Keys
Result
Enters Display Test Mode
Reboots the Keypad (the keypad beeps and the ARM and READY LED’s flash for several seconds)
6152RF: Fixed Word Display 2-Digit Zone Identifier
The ‘21’ digits are used for specific trouble indications. Refer to the control panel instructions for details.
= System NOT ARMED
= READY to Arm
= NOT READY to Arm
Arming Keys
Table 3 – Icon Descriptions
ICON DESCRIPTION
SETTINGS ARM AWAY ARM STAY ARM NIGHT STAY DISARM ARM MAXIMUM
TEST SYSTEM BYPASS ZONES
ARM INSTANT ASSIGN CODES
CHIME MODE
2. WIRE
• Connect only one wire per terminal.
• For Daisy-Chain Configurations, use wire splicing so only one wire is connected to each terminal.
SEE Detail
Keypad Front Cover
A
Install Four (4) Mounting Screws
Wall Surface
3. MOUNT
Mount on drywall, or in a single or double-gang electrical box.
AUX
AUX
Optional Front Cover Securing Screw (Required in European Installations)
DATAINDATA
OUT
CONTROL PANEL TERMINAL STRIP
[G ] DATA OU T [ ] GROUND [+] +12VDC IN [Y] DATA IN
16-24 AWG Only
Green
Black Red Yellow
Detail
A
KEYPAD
NO
C
G
Y
RELAY OUTPUT CONNECTIONS
y
INSTALLATION AND APPLICATION GUIDELINES
For installation, consider the following:
Locate the 6152RF in an area and at a height convenient for user operation.
The 6152RF must be at least 10 feet from the control panel to ensure proper RF receiver operation.
Local wireless keys (wireless keys programmed directly into the 6152RF) may be used regardless of whether the RF receiver in the 6152RF is enabled or disabled.
If using bi-directional devices, be sure to enable the transmitter module in the 6152RF (program address 7).
If transmitters are programmed into the control panel, be sure to enable the receiver (program address 6). (Do not exceed the number of receivers supported by the control panel.)
If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code must be entered into the 6152RF. This user code must also be programmed into the control panel.
You must set the House ID only if you are using RF keypads and/or bi-directional devices; AND the House ID Source is the 6152RF (Local).
Partition Installation Example
An example of an installation using two 6152RF Keypad / Transceivers with 2-Way Wireless Devices (e.g., 5828V) on two Partitions is shown below:
6152RF
Partition #1
System House ID = 1
5828 or 5804BD
Partition #1
House ID = 1
CONTROL
PANEL
Partition #1 Partition #2
6152RF
Partition #2
Local House ID = 2
5828 or 5804BD
Partition #2
House ID = 2
Table 4 – Partition Installation
Settings 6152RF #1
Keypad:
House ID:
House ID Source:
Receiver Enable:
Transmitter Enable:
Must be assigned to Partition 1 in the control panel
Match Partition 1 House ID in the control panel and House ID in Wireless Device
System
On
On
6152RF #2
Must be assigned to Partition 2 in the control panel
Match House ID in Wireless Device
Local
Off
On
4. PROGRAM
To program the keypad, first enter the Programming Mode, select a programming address and set the programming options. Refer to the tables below and on the following pages for details on entering Programming mode, default values and programming choices for each option.
Table 5 – Programming Mode
Action Result Displa
1. Enter Program Mode
Within 30 seconds of power up or reboot, press and hold down
the and keys at the same time for 3 seconds.
Note: Refer to Table 2 to reboot
the keypad.
2. Enter a Programming Address
(See Program Address column in Table 6)
3. Set programming options
Use the number and navigation keys to set the programming options.
Enters the Program mode at the Start screen and the keypad beeps three (3) times
Screen displays selected programming address
Refer to Choices column in Table 6.
oo, - -
flash
alternately
[If any other numbers or
letters
appear
press
.)
See
Display
column in
Table 6.
- The keypad will not enter programming mode if the panel is armed.
- Press the power up to enter the User mode. This mode allows individual local wireless keys to be enabled and disabled (useful if, e.g., a user accidentally loses a wireless key). Refer to the User Guide for instructions.
- To enter keypad Programming mode after power up period, reboot the keypad (see Table 2 on page 1) and try again after the keypad LED’s stop flashing.
- The keypad automatically exits the Program mode if no keys are pressed for 90 seconds.
- (For example, enter [1] to go to Keypad Address; enter [2] to go to Receiver Address).
- Press to erase the current information and move back.
- Press
beeps twice and the screen returns to Start
and keys 60 seconds or more after
to store the displayed information, the keypad
Notes
- 2 -
Table 6 – Programming Options
After editing any programming address, pressing
Enter Program Address
Enter [1]
Enter [2]
Enter [3]
Enter [4]
Enter [5]
Moves to Address
Description
Display Choices Default Notes
Keypad Address cA 00-31
Receiver Address rA 00-30
House ID
Only needed if RF keypads and/or bi-directional units are used and House ID source is set for Local.
House ID Source hS 1 = System
Wireless Key Editing d- Enter Existing Device
will save the displayed information and return to the Start screen.
1
16
2
00
hI 00-31 10
1 (System)
0 = Local
Enable keypad address in the Control panel.
The House ID entered here MUST match the House ID programmed in the RF keypad and the bi-directional unit.
System uses the House ID programmed in the control.
Local uses the House ID programmed in the keypad.
Number (1-8)
Enter [6]
Enter [7]
Enter [8]
Receiver Enable
Enable the receiver if RF transmitters or wireless keypads are programmed into the control.
Transmitter Module Enable
Enable if using bi-directional devices.
Wireless Key Auto Enroll
rE 1 = On (Enable)
0 = Off (Disable)
tE 1 = On (Enable)
0 = Off (Disable)
1 (Enable)
1 (Enable)
If enabled, the number of receivers cannot exceed the control panel capacity.
Enable Transmitter Module in only one keypad if more than one 6152RF is used and the House ID source is ‘System’.
Wireless Key User Code
Wireless Key Loop Function
See Programming Local Wireless Keys
for Address 8 programming details
Wireless Key On-Board Relay Assignment
Enter [9]
Restore Defaults EE 1 = Restores Defaults
Any Other Key = Does Not Restore Defaults
Enter [0]
High Security Mode† En 1 = Enable;
0 Disable
0 = Disable
Enter [A]
User Code u4 Enter 4-Digit User Code
(0000 – 9999)
1
For VISTA-10P/15P/20P/21IP use Keypad Addresses 16-23; For VISTA-40/50P/128/250 use Keypad Addresses 00-30
2
For VISTA-10P/15P/20P/21IP use Receiver Address 00; For VISTA-40/50P/128/250 use Receiver Addresses 01-30 and enable the receiver address in
the Control panel.
This user code will be used to enable the single button arming keys. Must be a valid user code programmed in the control.
When operating the system in High-Security mode, non-encrypted wireless keys will not function.
Upon exiting the Program mode, the 6152RF alternately flashes "Ad," the 2-digit keypad address, and the 2-digit receiver address. If either of these is incorrect, enter Program Mode again and reset the address(es) (see Tables 5 and 6).