PLEASE GO TO
PAGE 7 FOR
THE AGENCY
STATEMENTS
ADEMCO 6152RF Keypad / Transceiver – Installation and Setup Guide
Fixed Addressable Keypad/Transceivers for use with Honeywell Control Panels; incorporates normally-open
relay output with the functions of a medium 16 zone RF Receiver and a 5800 Transmitter module.
Programmable to support the
following :
- Bi-directional 5828/5828V
wireless keypads and wireless
keys (e.g., 5804BDV, 5834-4,
etc.)
- Up to eight button-type wireless
keys locally (programmed
directly into the keypad),
without occupying control panel
zones
- Up to 16 5800 series wireless
zones programmed into any
supported control panel
- Wireless keys with high security
mode enabled
To activate Function keys,
press and hold key for at
least 2 seconds; key pairs
are activated immediately.
Table 1 – Programmable
Function Keys
A or
B or and
C or and
D
Note: See the control’s instructions for
details on programming the Function
keys for panic alarms or other special
functions (i.e., macros).
and
1. OPEN
1
2
AWAY
BYPASS
STAY
CHECK INSTANT CANCELED
Sounder
6152RF-KEYPAD-LBLD-032613
ALARM
FIRE
Table 2 – Settings Ke
Settings Ke
Press for 2 Seconds
Press for 2 Seconds
and during the Display Test,
press and hold
for 3 Seconds
and
Control Panel
NO NIGHT AC
TESTPHONE
NOT READY
CHIME BAT
Programmable Function Keys
Result
Enters Display Test Mode
Reboots the Keypad (the
keypad beeps and the ARM
and READY LED’s flash for
several seconds)
6152RF: Fixed Word Display
2-Digit Zone Identifier
The ‘21’ digits are used for specific
trouble indications. Refer to the
control panel instructions for details.
= System ARMED
= System NOT ARMED
= READY to Arm
= NOT READY to Arm
Arming Keys
Table 3 – Icon Descriptions
ICON DESCRIPTION
SETTINGS
ARM AWAY
ARM STAY
ARM NIGHT STAY
DISARM
ARM MAXIMUM
TEST SYSTEM
BYPASS ZONES
ARM INSTANT
ASSIGN CODES
CHIME MODE
2. WIRE
• Connect only one wire per terminal.
• For Daisy-Chain Configurations, use
wire splicing so only one wire is
connected to each terminal.
SEE Detail
Keypad
Front
Cover
A
Install Four (4)
Mounting Screws
Wall
Surface
3. MOUNT
Mount on drywall, or in a single
or double-gang electrical box.
AUX
AUX
Optional Front Cover Securing Screw
(Required in European Installations)
DATAINDATA
OUT
CONTROL PANEL
TERMINAL STRIP
[G ] DATA OU T
[ ] GROUND
[+] +12VDC IN
[Y] DATA IN
16-24 AWG Only
Green
Black
Red
Yellow
Detail
A
KEYPAD
NO
C
G
Y
RELAY OUTPUT
CONNECTIONS
INSTALLATION AND APPLICATION GUIDELINES
For installation, consider the following:
• Locate the 6152RF in an area and at a height convenient for
user operation.
• The 6152RF must be at least 10 feet from the control panel
to ensure proper RF receiver operation.
• Local wireless keys (wireless keys programmed directly into
the 6152RF) may be used regardless of whether the RF
receiver in the 6152RF is enabled or disabled.
• If using bi-directional devices, be sure to enable the
transmitter module in the 6152RF (program address 7).
• If transmitters are programmed into the control panel, be
sure to enable the receiver (program address 6). (Do not
exceed the number of receivers supported by the control
panel.)
• If a local wireless key is programmed to arm/disarm or to
trigger a relay on the control panel, a user code must be
entered into the 6152RF. This user code must also be
programmed into the control panel.
• You must set the House ID only if you are using RF keypads
and/or bi-directional devices; AND the House ID Source is
the 6152RF (Local).
Partition Installation Example
An example of an installation using two 6152RF Keypad / Transceivers with 2-Way Wireless Devices (e.g., 5828V) on two Partitions is
shown below:
6152RF
Partition #1
System House ID = 1
5828 or 5804BD
Partition #1
House ID = 1
CONTROL
PANEL
Partition #1 Partition #2
6152RF
Partition #2
Local House ID = 2
5828 or 5804BD
Partition #2
House ID = 2
Table 4 – Partition Installation
Settings 6152RF #1
Keypad:
House ID:
House ID
Source:
Receiver
Enable:
Transmitter
Enable:
Must be assigned to
Partition 1 in the
control panel
Match Partition 1
House ID in the control
panel and House ID in
Wireless Device
System
On
On
6152RF #2
Must be assigned to
Partition 2 in the control
panel
Match House ID in
Wireless Device
Local
Off
On
4. PROGRAM
To program the keypad, first enter the Programming Mode, select a programming address and set the programming options. Refer to
the tables below and on the following pages for details on entering Programming mode, default values and programming choices for
each option.
Table 5 – Programming Mode
Action Result Displa
1. Enter Program Mode
Within 30 seconds of power up
or reboot, press and hold down
the and keys at
the same time for 3 seconds.
Note: Refer to Table 2 to reboot
the keypad.
2. Enter a Programming
Address
(See Program Address
column in Table 6)
3. Set programming options
Use the number and
navigation keys to set the
programming options.
Enters the Program mode
at the Start screen and
the keypad beeps three
(3) times
Screen displays selected
programming address
Refer to Choices column
in Table 6.
oo, - -
flash
alternately
[If any other
numbers or
letters
appear
press
.)
See
Display
column in
Table 6.
- The keypad will not enter programming mode if the panel is
armed.
- Press the
power up to enter the User mode. This mode allows individual
local wireless keys to be enabled and disabled (useful if, e.g., a
user accidentally loses a wireless key). Refer to the User
Guide for instructions.
- To enter keypad Programming mode after power up period,
reboot the keypad (see Table 2 on page 1) and try again
after the keypad LED’s stop flashing.
- The keypad automatically exits the Program mode if no keys
are pressed for 90 seconds.
- (For example, enter [1] to go to Keypad Address; enter [2]
to go to Receiver Address).
- Press to erase the current information and move
back.
- Press
beeps twice and the screen returns to Start
and keys 60 seconds or more after
to store the displayed information, the keypad
Notes
- 2 -
Table 6 – Programming Options
After editing any programming address, pressing
Enter
Program
Address
Enter [1]
Enter [2]
Enter [3]
Enter [4]
Enter [5]
Moves to Address
Description
Display Choices Default Notes
Keypad Address cA 00-31
Receiver Address rA 00-30
House ID
Only needed if RF keypads
and/or bi-directional units are
used and House ID source is
set for Local.
House ID Source hS 1 = System
Wireless Key Editing d- Enter Existing Device
will save the displayed information and return to the Start screen.
1
16
2
00
hI 00-31 10
1 (System)
0 = Local
Enable keypad address in the
Control panel.
The House ID entered here
MUST match the House ID
programmed in the RF
keypad and the bi-directional
unit.
System uses the House ID
programmed in the control.
Local uses the House ID
programmed in the keypad.
Number (1-8)
Enter [6]
Enter [7]
Enter [8]
Receiver Enable
Enable the receiver if RF
transmitters or wireless
keypads are programmed into
the control.
Transmitter Module Enable
Enable if using bi-directional
devices.
Wireless Key Auto Enroll
rE 1 = On (Enable)
0 = Off (Disable)
tE 1 = On (Enable)
0 = Off (Disable)
1 (Enable)
1 (Enable)
If enabled, the number of
receivers cannot exceed the
control panel capacity.
Enable Transmitter Module in
only one keypad if more than
one 6152RF is used and the
House ID source is ‘System’.
Wireless Key User Code
Wireless Key Loop
Function
See Programming Local Wireless Keys
for Address 8 programming details
Wireless Key On-Board
Relay Assignment
Enter [9]
Restore Defaults EE 1 = Restores Defaults
Any Other Key = Does
Not Restore Defaults
Enter [0]
High Security Mode† En 1 = Enable;
0 Disable
0 = Disable
Enter [A]
User Code u4 Enter 4-Digit User Code
(0000 – 9999)
1
For VISTA-10P/15P/20P/21IP use Keypad Addresses 16-23; For VISTA-40/50P/128/250 use Keypad Addresses 00-30
2
For VISTA-10P/15P/20P/21IP use Receiver Address 00; For VISTA-40/50P/128/250 use Receiver Addresses 01-30 and enable the receiver address in
the Control panel.
This user code will be used to
enable the single button
arming keys. Must be a valid
user code programmed in the
control.
† When operating the system in High-Security mode, non-encrypted wireless keys will not function.
Upon exiting the Program mode, the 6152RF alternately flashes "Ad," the 2-digit keypad address, and the 2-digit receiver address. If
either of these is incorrect, enter Program Mode again and reset the address(es) (see Tables 5 and 6).
- 3 -