SEE THE BOTTOM OF PAGE 2 FOR FCC & IC
5816OD Wireless Outdoor Sensor – Quick Installation Guide
For Online Support visit: http://www.security.honeywell.com/hsc/resources/MyWebTech/
WARRANTY For the latest warranty information go to: http://www.security.honeywell.com/hsc/resources/wa/
General Information and Component Identification
The Honeywell 5816OD Wireless Outdoor Sensor (referred to as
the Sensor) brings the convenience of wireless technology to the
outdoors. The major features are:
Weatherized security protection for an outdoor environment.
Great for sheds, barns, garages, pool gates, fences, and rural
mailbox (notifications).
Versatile mounting options on flat and round materials.
Cover and rear tamper detection.
Can be painted to coordinate with mounting surface.
Operating temp: – 40 to +50° C (– 40 to +122° F) at
RH of 100% (rain, snow).
Maximum Magnet Gap:
Wood: 1.75 inches
Metal: 1.25 inches
Installing / Replacing the Batteries
IMPORTANT:
Always change both batteries. Do not mix weak batteries with
new batteries.
Use two (2) lithium 1.5VDC AA cells. (For best life, use
Eveready's Energizer Ultimate LITHIUM AA batteries,
Honeywell part number 462)
OBSERVE BATTERY POLARITY.
Battery Replacement:
1. Remove cover screw and swing Sensor
to remove from Sensor
Mounting Plate.
2. Use screwdriver in any pivot point and pry Sealing Cover
off.
Replace batteries.
3. Orient the Sealing Cover
so the screw hole lines up with the
screw hole in the sensor cover, and press to close.
4. Engage Sensor
tabs into mating holes in Sensor Mounting
Plate and swing closed. Secure with cover screw.
Mounting Guidelines
This device is intended for vertical surfaces (to be mounted at a
sufficient height) where snow, ice and water buildup will not
interfere with its operation.
Mount the Magnet
identified by the side ribs on the Sensor.
Mount the Sensor
on the moveable surface.
Magnet
When used on wooden sheds and barns, mount the sensor and
magnet on the inside of the structure.
Use the Magnet Spacer
if needed to achieve proper alignment with the Sensor
Use screws suitable for the material being fastened to.
on the magnet sensing side of the Sensor as
on a stationary surface, and mount the
when mounting on metal surfaces; or
.
SENSOR
COVER
SCREW
FENCE
SENSOR
COMPONENT IDENTIFICATION
PRY
POINTS
SENSOR
MOUNTING
PLATE
TERMINAL BLOCK
FOR EXTERNAL
CONTACT SWITCH
SEALING
COVER
FLAT SURFACES
SENSOR
MOUNTING
PLATE
MOUNTING
SCREW (2)
MAGNET
MAGNET
MAGNET
SPACER
MAGNET
SPACER
5816OD-002-V0
GATE
5816OD-001-V0
MOUNTING
SCREW (4)
5816OD-003-V0
Curved Surfaces:
Suggested mounting hardware such as the strap ties and cable
ties are not supplied.
Mount using self locking stainless steel strap ties.
5816OD-005-V0
Self Locking Stainless Steel Strap Tie
Alternately you can use extra heavy duty Nylon 6/6 UV and
Temperature Rated cable ties
(0.5 inch wide).
If desired you may use screws in addition to the ties.
FENCE
COVER
SCREW
CURVED SURFACES
SENSOR
MOUNTING
PLATE
MAGNET
SPACER
GATE
POST
GATE
SENSOR
MAGNET
SENSING
SLIDE
MAGNET
5816OD-004-V0
ROUTING EXTERNAL WIRING – Optional for use with external
closed contact switches, such as the Honeywell N7945-2GY:
Note: Use minimum of 22AWG jacketed cable. The contact
switch must be a Form C (SPDT) type.
CLOSED
COMMON
OPEN
TO EXTERNAL
CONTACT SWITCH
UL – The wired contact must be less than 3 feet from the
transmitter.
1. Strip cable jacket back 4-inches to allow enough slack to
remove Sealing Cover
when changing batteries.
2. Pass cable through the access hole in Sensor Mounting Plate
Use cable notch on mounting plate to pass jacketed portion of
cable through. Then attach the Sensor Mounting Plate
.
.
SENSOR
CONNECT WIRES
TO TERMINAL BLOCK
IN BATTERY CHAMBER
3. Route cable to the external contact switch and fasten at
intervals to secure cable.
4. Remove the Sealing Cover
and thread wires through the
rubber wire seal. If installed, REMOVE ANY BATTERIES.
5. Connect wires to terminal block in battery chamber, then
INSTALL the batteries.
6. Replace the Sealing Cover
. (Note, orient the cover so the screw
hole lines up with the screw hole in the sensor cover, and press
to close.)
7. Engage Sensor
and swing closed. Secure with cover screw.
tabs into Sensor Mounting Plate mating holes
PAINTING THE SENSOR:
The sensor and magnet may be painted to coordinate its color with the mounting surface. Use
only paints that are made for plastic and follow the manufacturer’s direction for preparing the
plastic and applying the paint. Observe the required drying and curing times.
DO NOT USE METALLIC PAINT COLORS.
SEALING
COVER
Recommended Paints
Krylon® "Fusion for Plastic"
Rust-Oleum® "Plastic"
Dupli-Color® "Vinyl & Fabric Coating"
SENSOR
MOUNTING
PLATE
:
Programming the Control Panel
You must program the transmitter's serial number, input type (RF Supervised), response type, and loop # in the control panel. (Either or both
loops may be used. Loop # 2 is for the magnet sensing, and Loop # 1 is for the external contact switch.) Refer to the control panel’s instructions
for further details. Note: The transmitter's serial number may be found on the carton, and in the Battery Chamber.
This device complies with Part 15 of the FCC rules and RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions
suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les
interferences causant une reception indésirable.
FEDERAL COMMUNICATIONS COMMISSION STATEMENT
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User’s Manual.
Unauthorized changes or modifications could void the user’s authority to operate the equipment.
Ê800-04494UŠ
800-04494 6/10 Rev. A
FCC / IC STATEMENT
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright 2010 Honeywell International Inc.
www.honeywell.com/security
5816OD-006-V0