Ademco 8DL5800TSTAT Users Manual

INSTALLATION INSTRUCTIONS
W8665A,E

APPLICATION

Thermostat. The W8665A can be used with 1H/1C

INSTALLATION

single-zone conventional applications. The W8665E can
The W8665A,E RF Receiver Module (RM) provides 24 Vac control of HVAC equipment when used with a T8665A Chronotherm® IV Wireless Programmable
be used with up to three zones when used with a Honeywell EMM-3 Electronic MiniZone© Panel or TZ-3 TotalZone™ Panel. See Table 1.
Table 1. W8665 Description.
Model Application Stages Zones Comments
W8665A Conventional gas, oil or
W8665E Conventional gas, oil or
electric systems.
electric systems.
Single or multi-stage conventional or heat pump systems.
1H/1C One Use with T8665A Wireless
1H/1C Up to three Use with T8665A Wireless
1H/1C or up to 3H/2C
Thermostat.
Thermostats. Use with EMM-3 Electronic MiniZone™ Panel
Use with T8665A Wireless Thermostats. Use with TZ-3 TotalZone™ Zone Control Panel.
CAUTION
Equipment Damage Hazard. Do not mount W8665 inside HVAC equipment.
Mount only on wall.
Mount the thermostats in each zone of the living
1.
space using the installation instructions provided with each thermostat. Mount the dampers in the ductwork using the
2.
installation instructions provided with each damper. Mount the W8665 RF Receiver Module near the
3.
HVAC equipment on a wall. See Fig. 1. Level the W8665 for appearance only.
4.
® U.S. Registered Trademark Copyright © 2001 Honeywell • •All Rights Reserved
RETURN
AIR
E L E C T
R O N I C
A I R C
L E A N E
R
FURNACE
HIGH
EFFICIENCY
AIR CLEANER
OR BOILER
Fig. 1. W8665 mounting location.
WATER HEATER
W8665
M20162
69- 1534- 1
W8665A,E RF RECEIVER MODULE

WIRING

Wiring the W8665A

Wiring the W8665E

All wiring must comply with local electric codes and ordinances. See Fig. 2-4 wiring diagrams for specific applications. Refer to Tables 2 and 3 for terminal designations.
CAUTION
Voltage Hazard. Can cause electrical shock or equipment damage.
Disconnect power before beginning installation.
Connect the RF Receiver Module to the equipment loads. See Fig. 2 and Table 2.
Table 2. W8665A Terminal Designations.
Ter mi nal
Designation Function
R 24 Vac transformer hot.
C 24 Vac transformer common.
RZ 24 Vac system transformer.
Y Stage 1 cool.
W Stage 1 heat.
G Fan.
Powers RF receiver module.
Powers RF receiver module.
Not used in single zone applications.
Table 3. W8665E Terminal Designations.
Ter mi nal
Designation Function
R 24 Vac transformer hot.
C 24 Vac transformer common.
RZ 24 Vac system transformer.
RZ 24 Vac system transformer.
RZ 24 Vac system transformer.
Zone 1 Y Stage 1 cool.
Zone 1 W Stage 1 heat.
Zone 1 G Fan.
Zone 2 Y Stage 1 cool.
Zone 2 W Stage 1 heat.
Zone 2 G Fan
Zone 3 Y Stage 1 cool.
Zone 3 W Stage 1 heat.
Zone 3 G Fan
Powers RF receiver module.
Powers RF receiver module.
Connect to R of Zone1 thermostat on zone panel.
Connect to R of Zone 2 thermostat on zone panel.
Connect to R of Zone 3 thermostat on zone panel.
Connect the RF Receiver Module zones to the appropriate thermostat zone connections on the EMM-3 MiniZone™ Panel or TZ-3 TotalZone ™ Zone Control Panel. See Fig. 3 or 4 and Table 3.
69-1534-1 2
T8665A
THERMOSTAT
COMM
ZONE 1 W8665A
LED LED
LED STATES:
COMM: RAPIDLY FLASHING GREEN — RECEIVING INFORMATION FROM THERMOSTAT. GREEN OFF — STANDBY, READY TO RECEIVE INFORMATION. ZONE: RED ON — SYSTEM (HEAT, COOL OR FAN) IS ON. RED OFF — SYSTEM (HEAT, COOL OR FAN) IS OFF. FLASHING RED — ERROR. NOT RECEIVING SIGNAL FROM THERMOSTAT. RAPIDLY FLASHING RED — RECEIVER IN SET-UP MODE.
W8665A,E RF RECEIVER MODULE
DIP SWITCH SETTINGS:
OFF: NOT SET-UP TO RECEIVE INFORMATION FROM A THERMOSTAT. ON: READY TO RECEIVE INFORMATION FROM THERMOSTAT AFTER
SET-UP IS COMPLETE.
SET-UP:
MOVE DIP SWITCH TO ON POSITION AND MAKE THERMOSTAT CALL FOR FAN. NOTE: ALL OTHER THERMOSTATS MUST BE OFF (NOT CALLING) DURING SET-UP.
ZONE 1
COOL RELAY
YWG
HEAT
RELAY
FAN
RELAY
RCRZ
ZONE 1 ZONE 2 ZONE 3
ON
L2
L1 (HOT)
Fig. 2. Connecting the W8665A RF Receiver Module to the equipment.
M20163
3 69-1534-1