Ademco 8DL5800TSTAT Users Manual

INSTALLATION INSTRUCTIONS
W8665A,E

APPLICATION

Thermostat. The W8665A can be used with 1H/1C

INSTALLATION

single-zone conventional applications. The W8665E can
The W8665A,E RF Receiver Module (RM) provides 24 Vac control of HVAC equipment when used with a T8665A Chronotherm® IV Wireless Programmable
be used with up to three zones when used with a Honeywell EMM-3 Electronic MiniZone© Panel or TZ-3 TotalZone™ Panel. See Table 1.
Table 1. W8665 Description.
Model Application Stages Zones Comments
W8665A Conventional gas, oil or
W8665E Conventional gas, oil or
electric systems.
electric systems.
Single or multi-stage conventional or heat pump systems.
1H/1C One Use with T8665A Wireless
1H/1C Up to three Use with T8665A Wireless
1H/1C or up to 3H/2C
Thermostat.
Thermostats. Use with EMM-3 Electronic MiniZone™ Panel
Use with T8665A Wireless Thermostats. Use with TZ-3 TotalZone™ Zone Control Panel.
CAUTION
Equipment Damage Hazard. Do not mount W8665 inside HVAC equipment.
Mount only on wall.
Mount the thermostats in each zone of the living
1.
space using the installation instructions provided with each thermostat. Mount the dampers in the ductwork using the
2.
installation instructions provided with each damper. Mount the W8665 RF Receiver Module near the
3.
HVAC equipment on a wall. See Fig. 1. Level the W8665 for appearance only.
4.
® U.S. Registered Trademark Copyright © 2001 Honeywell • •All Rights Reserved
RETURN
AIR
E L E C T
R O N I C
A I R C
L E A N E
R
FURNACE
HIGH
EFFICIENCY
AIR CLEANER
OR BOILER
Fig. 1. W8665 mounting location.
WATER HEATER
W8665
M20162
69- 1534- 1
W8665A,E RF RECEIVER MODULE

WIRING

Wiring the W8665A

Wiring the W8665E

All wiring must comply with local electric codes and ordinances. See Fig. 2-4 wiring diagrams for specific applications. Refer to Tables 2 and 3 for terminal designations.
CAUTION
Voltage Hazard. Can cause electrical shock or equipment damage.
Disconnect power before beginning installation.
Connect the RF Receiver Module to the equipment loads. See Fig. 2 and Table 2.
Table 2. W8665A Terminal Designations.
Ter mi nal
Designation Function
R 24 Vac transformer hot.
C 24 Vac transformer common.
RZ 24 Vac system transformer.
Y Stage 1 cool.
W Stage 1 heat.
G Fan.
Powers RF receiver module.
Powers RF receiver module.
Not used in single zone applications.
Table 3. W8665E Terminal Designations.
Ter mi nal
Designation Function
R 24 Vac transformer hot.
C 24 Vac transformer common.
RZ 24 Vac system transformer.
RZ 24 Vac system transformer.
RZ 24 Vac system transformer.
Zone 1 Y Stage 1 cool.
Zone 1 W Stage 1 heat.
Zone 1 G Fan.
Zone 2 Y Stage 1 cool.
Zone 2 W Stage 1 heat.
Zone 2 G Fan
Zone 3 Y Stage 1 cool.
Zone 3 W Stage 1 heat.
Zone 3 G Fan
Powers RF receiver module.
Powers RF receiver module.
Connect to R of Zone1 thermostat on zone panel.
Connect to R of Zone 2 thermostat on zone panel.
Connect to R of Zone 3 thermostat on zone panel.
Connect the RF Receiver Module zones to the appropriate thermostat zone connections on the EMM-3 MiniZone™ Panel or TZ-3 TotalZone ™ Zone Control Panel. See Fig. 3 or 4 and Table 3.
69-1534-1 2
T8665A
THERMOSTAT
COMM
ZONE 1 W8665A
LED LED
LED STATES:
COMM: RAPIDLY FLASHING GREEN — RECEIVING INFORMATION FROM THERMOSTAT. GREEN OFF — STANDBY, READY TO RECEIVE INFORMATION. ZONE: RED ON — SYSTEM (HEAT, COOL OR FAN) IS ON. RED OFF — SYSTEM (HEAT, COOL OR FAN) IS OFF. FLASHING RED — ERROR. NOT RECEIVING SIGNAL FROM THERMOSTAT. RAPIDLY FLASHING RED — RECEIVER IN SET-UP MODE.
W8665A,E RF RECEIVER MODULE
DIP SWITCH SETTINGS:
OFF: NOT SET-UP TO RECEIVE INFORMATION FROM A THERMOSTAT. ON: READY TO RECEIVE INFORMATION FROM THERMOSTAT AFTER
SET-UP IS COMPLETE.
SET-UP:
MOVE DIP SWITCH TO ON POSITION AND MAKE THERMOSTAT CALL FOR FAN. NOTE: ALL OTHER THERMOSTATS MUST BE OFF (NOT CALLING) DURING SET-UP.
ZONE 1
COOL RELAY
YWG
HEAT
RELAY
FAN
RELAY
RCRZ
ZONE 1 ZONE 2 ZONE 3
ON
L2
L1 (HOT)
Fig. 2. Connecting the W8665A RF Receiver Module to the equipment.
M20163
3 69-1534-1
W8665A,E RF RECEIVER MODULE
LED STATES:
COMM: RAPIDLY FLASHING GREEN — RECEIVING INFORMATION FROM THERMOSTAT. GREEN OFF — STANDBY, READY TO RECEIVE INFORMATION. ZONE: RED ON — SYSTEM (HEAT, COOL OR FAN) IS ON. RED OFF — SYSTEM (HEAT, COOL OR FAN) IS OFF. FLASHING RED — ERROR. NOT RECEIVING SIGNAL FROM THERMOSTAT. RAPIDLY FLASHING RED — RECEIVER IN SET-UP MODE.
DIP SWITCH SETTINGS:
OFF: NOT SET-UP TO RECEIVE INFORMATION FROM A THERMOSTAT. ON: READY TO RECEIVE INFORMATION FROM THERMOSTAT AFTER
SET-UP:
MOVE DIP SWITCH TO ON POSITION AND MAKE THERMOSTAT CALL FOR FAN. NOTE: ALL OTHER THERMOSTATS MUST BE OFF (NOT CALLING) DURING SET-UP.
M1 M4 M6 C R Y W G
EMM-3
T8665A
ZONE 1 THERMOSTAT
COMM
ZONE 1 ZONE 2 W8665E
LED LED LEDLED
SET-UP IS COMPLETE.
ZONE 1
YWG
M1 M4 M6 C R Y W G M1 M4 M6 C R Y W G
T8665A
ZONE 2 THERMOSTAT
ZONE 3
ZONE 2
YWG
ZONE 3
YWG
T8665A
ZONE 3 THERMOSTAT
ZONE 1 ZONE 2 ZONE 3
ON
R C RZ RZ RZ
R C
24V, 40 VA TRANSFORMER
C
M20164
R
Fig. 3. Connecting the W8665E RF Zone™ Panel to the EMM-3 MiniZone™ Panel to control 1H/1C with up three
W8665E
ZONE 1
YWG
W2 L G Y R W M6M4M1
TZ-3
Fig. 4. Connecting the W8665E RF Zone™ Panel to the TZ-3 TotalZone™Zone Control Panel to operate up to
3H/2C with up to three thermostat zone connections.
thermostat zone connections.
ZONE 2
YWG
W2 L G Y R WM6M4M1 W2 L G Y R WM6M4M1
ZONE 3
YWG
R C RZ RZ RZ
OC OC TR2 TR1
24V, 40 VA TRANSFORMER
CR
M20165
69-1534-1 4

SETUP

Setting Up W8665A,E to Receive Signals
from the T8665A Thermostat(s)
The T8665A Thermostat(s) require(s) setup to send
Single Zone Applications (1 W8665A/1 T8665A)
Multizone Applications (1 W8665E/Up to 3
T8665A)

OPERATION

W8665A Sequence of Operation

W8665E Sequence of Operation

W8665E Single and Multi-Stage
Operation
signals to the W8665 Receiver Module to operate:
• The W8665A Receiver is used for single-zone applications.
• The W8665E RF Zone™ Panel is used for up to three T8665A Thermostats for multi-zone applications.
IMPORTANT
Be sure the thermostat is at least five feet away from the W8665 during setup.
Power up the W8665A and install the batteries in
1.
the T8665A Thermostat. Place the W8665A Zone 1 DIP switch to the On
2.
position.
NOTE: The W8665A Zone 1 LED will flash.
Press the thermostat Fan On key:
3.
a. The receiver accepts the message and stores
the identity. b. The zone 1 LED stops flashing. c. The thermostat is now set to send signals to
the W866A Receiver.
NOTE: The word, On, and a fan blade appear in the
thermostat display to indicate the thermostat is calling for the fan to turn on.
d. Use Fan key to turn off fan.
Set System and Fan keys to the desired locations.
4.
NOTE: At any time, if you want to stop the thermostat
from sending signals to the W8665 Receiver, turn the DIP switch to Off. Then repeat steps 1­3 to set up the thermostat to send signals to the W8665 Receiver.
Power up the W8665 and install the batteries in the
1.
T8665 Thermostats. Set the thermostats so no zones are calling for sys-
2.
tem or fan. Set up each zone separately to ensure that a
3.
unique address is used for each zone. Place the zone 1 DIP switch on the W8665E
4.
Receiver to the On position.
NOTE: The W8665E zone 1 LED will flash.
Press the thermostat Fan On key:
5.
a. The receiver accepts the message and stores
the zone identity. b. The zone 1 LED stops flashing. c. The thermostat is now set to send signals to
the W8665E Receiver.
NOTE: The word, On, and a fan blade appear in the
thermostat display to indicate the thermostat is calling for the fan to turn on.
W8665A,E RF RECEIVER MODULE
d. Use Fan key to turn off fan.
NOTE: At any time, if you want to stop the thermostat
from sending signals to the W8665 Receiver, turn the DIP switch to Off. Then repeat steps 4 and 5 to set up the thermostat to send signals to the W8665 Receiver.
Repeat steps 4 and 5 for zones two and three.
6.
Set System and Fan keys to desired locations.
7.
Attach the zone number sticker, included with the
8.
thermostat, onto the thermostat case on the inside of the thermostat cover. See Fig. 5.
Zone 2
Zone 3
Zone 1
Place one label inside each thermostat door.
Fig. 5. Zone number stickers for inside of thermostat
On a call for heating or cooling, the thermostat sends a signal to the W8665A to bring on the heating or cooling until the call is satisfied. The Comm LED flashes when the W8665A receives a signal from the thermostat to turn on the system or approximately every ten minutes as a status update. On a call for heating, cooling or fan, the zone LED lights red.
On a call for heating or cooling from any zone, the thermostat sends a signal to the W8665E to bring on the heating or cooling in that zone until the call is satisfied. The Comm LED flashes when the W8665E receives a signal from the thermostat in any zone to turn on the system or approximately every ten minutes as a status update. On a call for heating, cooling or fan, the zone LED lights red.
The first stage is energized by the thermostat. To control multistage conventional and heat pump systems, the W8665 must be wired to a zone control panel that is able to control multiple stages of heat and/or cool (such as the TZ-3 TotalZone™ Zone Control Panel). The zone panel (not the RF panel) controls these stages based on the number of zones calling or with a timer. See the Zone Control Panel Instructions for more details on how to control up to three stages of heat and two stages of cool.
M13426
cover.
5 69-1534-1
W8665A,E RF RECEIVER MODULE

LED Operation (See Table 4)

NOTE: See Setting up W8665A,E Receiver Module to
Receive Signals from the T8665A Thermostat section.
Table 4. LED Operation.
LED LED action Meaning
Comm Flashes rapidly for 2-3 seconds. Indicates device is currently receiving information from the
Zones 1-3 On constantly. Indicates system (heat, cool, or fan) is on.
Zones 1-3 Off constantly. Indicates system (heat, cool, or fan) is off.
Zones 1-3 Flashes rapidly until signal is
Zones 1-3 Flashes continuously. Indicates a problem receiving signals from the transmitter
received.
T8665 Thermostat.
Indicates zone is being set up to receive signals from a transmitter (T8665 Thermostat).
(T8665 Thermostat). See Troubleshooting Guide for more information.
69-1534-1 6

TROUBLESHOOTING (TABLE 5)

Table 5. Troubleshooting Guide.
Symptom Possible Cause Action
Display does not come on. Thermostat is not being
Heating does not come on. System on indicator
( = heat) is showing in display.
Cooling does not come on. System on indicator ( = cool) is showing in display.
Wait is displayed and the call for cool has not started.
2nd stage heat or cool (or 3rd stage heat) does not energize.
Fan does not come on with a call for electric heat.
powered.
Communication is not being completed.
Heating load at W8665 is not connected correctly.
Communication is not being completed.
Cooling load at W8665 is not connected correctly.
Compressor protection is in effect.
W8665 is not wired to a TZ-3 TotalZone™ Zone Control Panel that controls the multiple heat and cool stages.
Electric heat setting is not configured.
Fan load at W8665 is not connected correctly.
Check if batteries are present and installed correctly.
If batteries are in and installed correctly, replace
thermostat.
End and repeat the call for heat. Check the Comm LED and Zone LED on the W8665 while the call is being made.
If the Comm LED does not flash when thermostat
first calls for equipment, turn that zone DIP switch to Off. Refer to Setup section to reset the W8665. If the Zone LED flashes continuously, turn that
zone DIP switch to Off. Refer to Setup section to reset the W8665. Check if 24 Vac is present:
Check between R and C on W8665.
Check between W of troubled zone and C on
W8665.
If voltage is present, troubleshoot heating system.
End and repeat the call for cool. Wait five minutes for the compressor delay to end.
If the Comm LED does not flash when thermostat
first calls for equipment, turn that zone DIP switch to Off. Refer to Setup section to reset the W8665. If the Zone LED flashes continuously, turn that
zone DIP switch to Off.Refer to Setup section to reset the W8665. Check if 24 Vac is present:
Check between R and C on W8665.
Check between Y of troubled zone and C on
W8665.
If voltage is present, troubleshoot cooling system.
Compressor protection can be set on the T8665A from 0 to 5 minutes to prevent compressor damage due to rapid cycling. Wait until the compressor protection period expires.
Wire W8665 to TZ-3 TotalZone™ Zone Control Panel to control multi-stage systems.
Check TZ-3 TotalZone™ Zone Control Panel and set correctly.
Set thermostat Installer Setup Number 2 to 1 for electric heat. See thermostat instructions for details.
Check that 24 Vac is present between R and C.
Check that 24 Vac is present between G and C.
If voltage is present, troubleshoot system.
W8665A,E RF RECEIVER MODULE
7 69-1534-1
W8665A,E RF RECEIVER MODULE

FCCID: CFS8DL5800TSTAT

FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and, if not installed and used properly; that is, in strict accordance wih the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user or installer may find the following booklet prepared by the Federal Communications Commission helpful:
This booklet is available under Stock No. 004-000-00450-7 from the US Government Printing Office, Washington, DC
20402.
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User’s Manual. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
“Interference Handbook”
Home and Building Control Home and Building Control
Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario
69-1534-1 G.H. 09-01 www.honeywell.com/yourhome
M1V 4Z9
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.