5800PIRRES-AP Wireless Motion Sensor - Installation Instructions
FCC & IC AGENCY
STATEMENTS ON
BOTTOM OF PAGE 2
LOCATION
1
/ EMPLACEMENT
No / Non / No
Satisfactory
OPEN
2
OUVERTURE
/
CONNECT THE BATTERY, ENROLL THE
3
SENSOR, CONDUCT GO / NO GO TEST,
AND PERFORM WALK TEST / METTRE
LES PILES EN PLACE ,
Panasonic CR123A /
ENROLL THE SENSOR, CONDUCT GO / NO GO
Duracell DL123 & DL123A /
TEST, AND PERFORM WALK TEST
Honeywell 466
Observe
correct polarity
Observe correct
polarity
/
See page 2 for
more information /
See page 2 for
more information
MOUNT
4
- Use only left OR right side
corner mounting holes.
Recommended
Screws: #6 (3.5 mm)
/ INSTALLATION
7.5 - 8 ft
(2.3 - 2.4 m)
TOP
1
2
1
2
DETECTION PATTERNS / COUVERTURE DE
A
DETECTION
35' / 11m Wide Angle Animal Immune Lens
(P/N 5-532-719-00)
Top View / Vue de Dessus
0
20'
6m
13'
4m
7'
2m
0
7'
2m
13'
4m
20'
6m
Side View / Vue de Cote
0
7'6"
(2.3m)
2m
7'
2m
13'
7'
18
19
20
4m
13'
4m
12
13
14
15
16
17
20'6m27'
1
2
10
11
20'6m27'
8m
3
4
8
9
8m
ACCESSORIES / ACCESSOIRES
B
35'
11m
SMB-10
1
(P/N 0-000-110-01)
SMB-10C
Swivel Mount Bracket
Swivel Mount Ceiling Bracket
(P/N 0-000-111-01)
SMB-10T
1
Swivel Mount Bracket w/Tamper
(P/N 0-000-155-01)
5
6
7
35’ x 40’ (11 m x 12 m)
IS2500-PALK 2
35’ x 40’ (11 m x 12 m)
1
Not verified by ETL.
Mounting Height:
IS2500-HSLK 1
High Security Lens Kit
Pet Alley Lens Kit
1
7 – 9 ft (2.1 m – 2.7 m).
2
4 ft (1.2 m).
35'
11m
0
PRELIMINARY DRAFT 8/24/09 - 1 -
5800PIRRES-AP Wireless Motion Sensor - Installation Instructions
ENROLL THE SENSOR
Enroll the sensor in the control panel prior to its usage in the
SPECIFICATIONS
Power: Battery* (included).
system. Refer to the control panel instructions for programming
details. Program the sensor as an “RF” type (supervised
RF) device.
To enroll: connect the battery and wait for power up to end
(see LED Indications table). When prompted for the serial
number, activate the sensor (wave a hand in front of the lens)
to enroll the sensor.
Loop 1 Pulse count 2; Up to 80 lbs. Animal Immunity
Battery Life, years (typical):
RF Frequency:
Operating Temperature:
(for indoor use environment)
Relative Humidity, no
condensation:
Detectable Walk Rate:
LED INDICATIONS
Condition
Power Up Blinks once per second (for < 45 seconds)
Walk Test ON for 3 seconds = Loop 1 / Low Sensitivity Alarm
Indicator LED
Flickers rapidly for 3 seconds = walk test period ended
MOUNT THE SENSOR (See page 1)
Before mounting the transmitter permanently, conduct Go/No
Go tests (see control panel manual) to verify adequate signal
strength and reorient or relocate the sensor if necessary.
For Animal (Pet) Immunity:
• Install the sensor where animals cannot come within 6 ft
(1.8 m) of the sensor by climbing on furniture or other
objects.
• Aim the sensor away from stairways, furniture or other
objects that can be climbed on by animals.
• Do not use optional swivel mount brackets.
WALK TESTING
The 10 minute walk test mode begins after power up, and can
be restarted by removing and replacing the battery.
As you walk through the detection pattern, the sensor LED will
light for 3 seconds to indicate each alarm detection.
Note: In walk test mode all transmissions will be sent as they
occur. During normal operation, only one transmission
sequence will occur within a 3-minute period to conserve
battery life.
TROUBLESHOOTING
Problem: The system displays a “low battery” message.
Solution
: Replace the battery within 7 days.
Temperature Compensation:
* Battery Caution: Risk of fire, explosion and burns. Do not recharge,
disassemble, heat above 212° F (100° C), or incinerate. Dispose of
used batteries promptly. Keep away from children.
APPROVALS / LISTINGS
• FCC
• IC
• C-Tick
• CE
• SIA-PIR-01 Passive Infrared detector standard features
for false alarm immunity.
• cETLus Listed
COMPLIANCE NOTES
• Product must be tested at least once each year.
• Product must be installed within the protected area only.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the
Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's
authority to operate the equipment.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules and RSS-210 of the IC rules. Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada.
Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer
d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une réception indésirable.
2009 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
PRELIMINARY DRAFT 8/24/09 - 2 -
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
www.honeywell.com/security
1 x 3 V, Lithium;
CR123A / DL123 / DL 123A / 466
5
315 MHz
14° to 131° F (-10° to 55° C)
95% max.
0.7 – 7ft/Sec. (0.2 – 2.0m/Sec.)
Advanced Dual Slope
Ê800-13192-Š
P/N 800-13192 Rev A 10/12