Ademco 51360SL User Manual

Instruction Manual
2#7,!
Premium Portable Wireless Chime & Push
69-2109EFS-06
Installation Instructions
69-2109EFS—06 ii
Contents
Checking pack contents............................ 1
Safety..........................................................2
Quick start.................................................. 2
Open bell push........................................... 3
Fit the push battery ...................................3
Fit the chime battery..................................4
Sliding window...........................................4
Volume control ........................................... 5
Use of icons ...............................................6
Programming procedures.......................... 7
Recall function ...........................................8
Chime sounds ............................................8
Mount bell push .........................................8
Chime position ........................................... 9
Troubleshooting .......................................10
Specifications.......................................... 12
Disposal and recycling ............................12
Declaration ............................................... 13
Guarantee................................................. 13
RCWL300A
1 69-2109EFS—06
Premium Portable Wirefree Chime with Push
Thank you for choosing this Honeywell product. Please use the following instructions to ensure correct installation and use. Keep these notes in a safe place for future ref­erence.
Checking Pack Contents
Unpack your chime kit and identify the following parts:
• Chime
• Wall mounting bracket
• Bell push
• CR2032 battery for bell push
• 2 x fixing screws for push
• 2 x fixing screws for chime
• 2 x wall plugs
• Adhesive pad
• Self-adhesive icons
You will need:
• 3 X LR6 ‘AA’ Alkaline batteries
• A Phillips screwdriver
• A small flat bladed screwdriver
• A 1/4-in. (6 mm) masonry drill
Installation Instructions
69-2109EFS—06 2
Safety
Before proceeding with the installation, please note the following safety warnings:
• Always follow the manufacturer’s advice when using power tools and wear suitable protective equipment (e.g. safety goggles) when drilling holes, etc.
• Before drilling holes in walls, check for hidden electricity cables and water pipes. The use of a cable/pipe locator is advisable if in doubt.
Quick Start
The bell push supplied with this kit is pre-programmed to operate with the chime. You need to do the following to get started:
• Open the bell push
• Fit the push battery
• Fit the chime batteries
• Check the volume setting
When you operate the bell push, the chime will sound and the 1st Icon will flash. If you have additional pushes or you want to assign a different icon to your push, you will need to follow the programming procedure.
RCWL300A
3 69-2109EFS—06
Open the Bell Push
Insert a flat bladed screwdriver into the slot A at the base of the push. Carefully lever the cover and base apart (Fig. 1).
Fit the Push Battery
Insert the CR2032 coin cell. Ensure the face marked ‘+’ is uppermost (Fig. 2).
M27199
A
M27153
CR2032
+
CR
2032
+
Fig. 1
Fig. 2
Installation Instructions
69-2109EFS—06 4
Fit the Chime Batteries
To remove the chime battery cover, press at point B and slide the cover back 1/4 in. (5 mm), then lift off. Insert 3 x LR6 ‘AA’ alkaline batteries (not supplied). Observe polarity as marked inside the battery compartment.
Sliding Window
Release the catch (B) and slide open the window.
M27200
B
M27201
B
Fig. 3
RCWL300A
5 69-2109EFS—06
Volume Control
The volume control is behind the slid­ing window on the front of the chime. Initially, set the control to mid-point. After you have tested your system, adjust to the desired volume.
M27202
VOLUME CONTROL
Installation Instructions
69-2109EFS—06 6
Use of Icons
In addition to the chime sounds, your chime has a visual indication to show which device has activated it. An icon will illuminate when the chime is activated by a bell push or another compatible device. The chime supports 3 icons.
The ‘Main door’ and ‘Back door’ icons are usually used for bell pushes. The other icon is intended for use with other compat­ible devices, such as PIR movement detectors and Telephone ring detector. Icons numbered 1 to 3 are also included. The Icons are self-adhesive, supplied in strips of 3. They can be changed, if required, by opening the sliding window of the chime and gently peeling off the strips. If desired, the strips can be cut into individual icons and attached to the chime in a different order.
Use the Programming procedure to change the icon associated with a push.
MAIN
DOOR
BACK
DOOR
ALERT
SYMBOL
RCWL300A
7 69-2109EFS—06
Programming Procedure Learn Procedure
To enable your chime to learn the identity of your bell push:
• Press the O button and keep it
pressed. Each Icon will light in turn. When the Icon you want is lit, release the button.
• While the Icon you have selected is lit, operate your push. The chime will sound. The Icon will flash.
Unlearn Procedure
If you want to remove a push from the chime’s memory:
• Press the O button and keep it
pressed.
• Each Icon will light in turn. When the Icon associated with the push to be unlearned is lit, release the button.
• Press and hold down both O &
buttons, until a ‘beep’ sound is
heard.
Installation Instructions
69-2109EFS—06 8
Changing the Tune
Operate the push. While the Icon is flash­ing, press the button. Press the button again and the tune will change. Repeat until the tune you want plays.
Recall Function
A short push of the O button will flash
the Icon that was last in use.
Chime Sounds
To hear the chime sounds without oper­ating the bell push, press the button. Press the button again and the tune will change.
Mount the Push
Mount using either the double-sided adhesive pad or the screws provided. (See Fig. 6 )
Test your push before mounting. Avoid mounting to metal structures.
M27155
TOP
Fig. 6
RCWL300A
9 69-2109EFS—06
Chime Position
The Chime can be free standing or wall mounted using the wall mounting bracket provided. If wall mounting is preferred, screw the bracket to the wall (see Fig 7). The Chime hooks onto the wall bracket as illustrated.
M27203
Fig. 7
Installation Instructions
69-2109EFS—06 10
Troubleshooting A ‘beep’ sound is heard in learn mode…
• The push you are programming has already been learned by the chime.
• If you want to change the Icon associated with the push, use the un-learn procedure, then program the push again.
Two ‘beep’ sounds are heard after the normal chime sound…
• This indicates a low battery in the bell push that activated the chime. Fit a new battery, type CR2032.
When the bell push is operated, the amber confidence light does not turn on, or is only on for a short time…
• In normal operation, the amber light will turn on for 1 second. When the battery is weak, the light will only turn on for a short time. Fit a new battery, type CR2032.
The chime does not work…
• Check that the batteries are the correct type, LR6 ‘AA’ cells. Only use alkaline batteries.
• Check that the batteries are fitted correctly, with correct polarity.
• The chime could be out of range of the bell push. Try the chime in a different location.
• The chime might not have learned the identity of the bell push. Follow the programming procedure.
RCWL300A
11 69-2109EFS—06
Troubleshooting The chime does not sound…
• Check that the volume control is not at the minimum setting.
Range is reduced…
• Metal structures, including uPVC door frames can reduce the range of the product. Avoid mounting the push or chime on or near metal structures.
• Other equipment can cause radio interference that affects your chime.
• Walls and ceilings will reduce the range.
• Weak batteries will reduce range. Replace every 12–18 months. In cold conditions (below 41ºF [5ºC]), batteries may need to be replaced more often.
Amber light flashes…
• When the chime battery is low, an amber light will flash every 5 seconds. Fit new batteries in the chime, type LR6 ‘AA’ cells. Only use alkaline batteries.
Installation Instructions
69-2109EFS—06 12
Specifications
Specification Chime Bell push
Operating Temperature 32°F to 104°F
0ºC to 40ºC
14°F to 104°F
-10ºC to 40ºC RF Frequency US/Canada 916.8 MHz 916.8 MHz Range (open field) 225 ft. (69 m) See Chime Sound Level (typical) 80dBA @ 3 ft. (1m) ­RF Power - <1mW Battery Type LR6 CR2032 Battery Life (5 activations/day) 12 months 18 months Rain proof N/A Pass UL1598 rain test.
Disposal & Recycling
Batteries and waste electrical products should not be disposed of with household waste. Please recycle where these facilities exist. Check with your local authority or retailer for recycling advice.
RCWL300A
13 69-2109EFS—06
Declaration
Honeywell hereby declares that this product complies with Part 15 of the FCC rules and Industrial Canada standards.
This device operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Caution: Changes or modification not expressly approved by the party responsible for regula-
tory compliance could void the user’s authority to operate the equipment.
Guarantee
Honeywell guarantees this product for 1 year from the date of purchase. Proof of pur­chase is required: this does not affect your statutory rights. If you require further infor­mation about your product call the Honeywell help line at 1-800-468-1502.
Loading...
+ 33 hidden pages