If you need any assistance to get your unit functioning properly, please have your
product information ready and contact Addonics Technical Support at:
Loosen the 3 screws at the back of the
tower using a Philips screwdriver by
turning counter-clockwise. Separate the
metal casing of the tower from the housing
by lifting up the casing.
Installing drives into the
Storage Tower
Step 1
Screw the hard drives into the optional
mounting brackets or slide in 5.25” devices
into the tower. Other types of enclosures
like the 5SA disk array can also be
mounted. Mounting one 5SA disk array
and another one 3SA disk array allows you
to mount a maximum of 8 SATA drives.
Screws
Step 2
Using 3.5” SATA Hard Disk Drives
Connect the internal SATA data cable to
the data port of the hard drive then connect
the 15-pin SATA power connector to the
power port on the hard drive.
Hard Disk
Step 3
Secure the hard disk by using screws
provided. Repeat the above procedure for
additional hard drives.
BZS – Error buzzer function
EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a
spare). If EZ is ENABLED anda drive failure occurs, the spare will
automatically act as a drive replacement and rebuilding will automatically
start.
M2 – RAID mode 2
M1 – RAID mode 1
M0 – RAID mode 0
1. Error buzzer function is ENABLED (BZS) when dip switch is in OFF position
2. Auto-rebuilding to spare drive is DISABLED (EZ)
3. Individual drive mode is ENABLED (M0~M2)
Note: When the default factory RAID setting is used, independent drive configuration
and optical drive are supported only when connecting to controllers with Silicon
Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM)
compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.
SW1
OFF
OFF
OFF
OFF
1 2 3 4 5
BZS EZ M2 M1 M0
OFF
LED Pin Header
J3 J1
P4 P3 P2 P1 P0 P5 P4 P3 P2 P1 P0 P5
Error LED Activity LED
J1 – Drive Activity LED
P5 – Activity LED for eSATA host port lights up when it is connected to a
SATA controller card.
P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is
connected and blinks when there’s drive activity.
J3 – Error LED
P5 – error LED for eSATA host port
P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5
Setting or Modifying the RAID Mode Using the JMicron
HW RAID Manager Utility Program:
1. For Windows users, install the JMicron HW RAID Manager located on the
SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This
manager can be use to create and monitor the status of the RAID volume.
It is recommended to use the default factory RAID DIP switch setting when
using the JMicron HW RAID Manager.
2. Modify the RAID mode on the 5-port HPM-XU using DIP switch
Recommended to be used on operating system without JMicron HW RAID
Manager support like Linux, Mac & Solaris. Windows users can also use the
procedure below.
Note: Steps A to D need to be performed each time the raid mode is modified.
a. Set the DIP switch to factory default setting.
OFF
OFF
OFF
OFF
OFF
SW1
b. Press the RAID setting button with a ball point pen.
c. While pressing the RAID setting button turn on the system power
where the HPM is connected. The buzzer will sound while holding the
RAID sett
initialization. A single beep will be heard to indicate initialization is
completed. The above steps act as a reset.
When 4 drives are connected to the HPM-XU, the 4 drives will be
configured as a 4-drive RAID10 array.
1 2 3 4 5
BZS EZ M2 M1 M0
Clone Mode
SW1
1 2 3 4 5
BZS EZ M2 M1 M0
When 2 drives are
connected to the HPM-XU,
and DIP switch is set to this
setting, the 2 drives will be
configured as a 2-drive
RAID1 array.
Clone’s action is similar to
RAID1. However, all of the
hard drives will be mirrored.
Clone mode is useful
especially when users like
to copy data from a source
hard drive to the drives
connected to the HPM-XU.
Notes on Spare Drives using the Easy RAID Setting (EZ)
When EZ function is ENABLED, the auto-rebuilding to spare drive is automatic.
The degraded RAID group will start rebuilding automatically by using the existing
spare drive.
* Spare drive can be either plugged before RAID building or a new drive can be plug
as the spare drive when RAID rebuild is required.
A. Which port acts as a spare drive?
The last drive will automatically become the spare drive.
For a 3-drive RAID5 with spare:
Drives connected to SATA ports 1~3 belong to the active RAID5
array and drive connected to port 4 is the spare.
For a 4-drive RAID10 with spare:
Drives connected to SATA ports 1~4 belong to the active RAID10
array and drive connected to port 5 is the spare.
For a 2-drive RAID1 with spare:
Drives connected to SATA ports 1& 4 belong to the active RAID1
array and drive connected to port 5 is the spare.
B. When will rebuild action start?
•When the raid fails and EZ is enabled, the HPM-XU will automatically rebuild the RAID group using the spare.
•When the raid fails and EZ is disabled, the HPM-XU will NOT
rebuild the raid group unless you install a good drive to replace the
failed drive.
Connecting the Power Cable and Storage Tower to the
Computer
a. Connect the power cord provided from the
wall outlet to the back of the tower.
b. Make sure the power is off (power LED
light should be off).
c. Connect the eSATA or USB3 cable from
the back of the tower to the matching
port on the computer.
Back
Power
Connecto
Power
Switch
Power on/off control
a. A main power switch is located at the back
of the tower. Turn the switch on. Another
auxiliary switch is located on the front of
the tower.
b. Make sure the power is off on the auxiliary
switch (power LED light should be off).
c. Power on the tower.