If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at:
Hours: 8:30 am - 6:00 pm PST Phone: 408-453-6212 Email: http://www.addonics.com/support/query/
Page 2
Removing Cover of Storage Tower V
Loosen the 3 screws at the back of the tower using a Philips screwdriver by turning counter-clockwise. Separate the metal casing of the tower from the housing by lifting up the casing.
Installing drives into the Storage Tower
Step 1
Screw the hard drives into the optional mounting brackets or slide in 5.25” devices into the tower. Other types of enclosures like the 5SA disk array can also be mounted. Mounting one 5SA disk array and another one 3SA disk array allows you to mount a maximum of 8 SATA drives.
Screws
Step 2
Using 3.5” SATA Hard Disk Drives Connect the internal SATA data cable to the data port of the hard drive then connect the 15-pin SATA power connector to the power port on the hard drive.
Hard Disk
Step 3
Secure the hard disk by using screws provided. Repeat the above procedure for additional hard drives.
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
Page 3
SATA Port 2
SATA Port 4
Error LED Jumper Block (J3)
SATA Port 3
SATA Port 0
SATA Port 1
Dip Switch Settings
Raid Mode 1 2 3 4 5
Drive activity LED Jumper Block (J1)
Floppy Power Connector
RAID Setting ButtonDip SwitcheSATA Host Port (Port 5)
Individual Drive
(Factory Default)
0
1 and 10
3
5
Clone
Large
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Enable ERR Buzzer Function
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Auto­Rebuilding to Spare Drive
OFF
ON
ON
ON
OFF
OFF
ON
Port Multiplier Mode
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
Page 4
Default factory DIP Switch setting:
SW1 – RAID Setting DIP Switch
BZS – Error buzzer function EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start. M2 – RAID mode 2 M1 – RAID mode 1 M0 – RAID mode 0
1. Error buzzer function is ENABLED (BZS) when dip switch is in OFF position
2. Auto-rebuilding to spare drive is DISABLED (EZ)
3. Individual drive mode is ENABLED (M0~M2)
Note: When the default factory RAID setting is used, independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.
SW1
OFF
OFF
OFF
OFF
1 2 3 4 5
BZS EZ M2 M1 M0
OFF
LED Pin Header
J3 J1
P4 P3 P2 P1 P0 P5 P4 P3 P2 P1 P0 P5
Error LED Activity LED
J1 – Drive Activity LED
P5 – Activity LED for eSATA host port lights up when it is connected to a SATA controller card. P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is connected and blinks when there’s drive activity.
J3 – Error LED
P5 – error LED for eSATA host port P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
Page 5
Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program:
1. For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume.
It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager.
2. Modify the RAID mode on the 5-port HPM-XU using DIP switch
Recommended to be used on operating system without JMicron HW RAID Manager support like Linux, Mac & Solaris. Windows users can also use the procedure below.
Note: Steps A to D need to be performed each time the raid mode is modified.
a. Set the DIP switch to factory default setting.
OFF
OFF
OFF
OFF
OFF
SW1
b. Press the RAID setting button with a ball point pen.
c. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the RAID sett initialization. A single beep will be heard to indicate initialization is completed. The above steps act as a reset.
d. Power off the system power.
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
1 2 3 4 5
BZS EZ M2 M1 M0
ing button. Release it after at least 5 seconds for hardware
Page 6
e. On the DIP switch, change (M0 to M2) setting to the desired RAID mode using the diagram below.
All settings on the diagram shows
Error buzzer function is ENABLED
EZ function is DISABLED.
SW1
SW1
SW1
RAID 0 Mode
OFF
OFF
ON
ON
ON
1 2 3 4 5
BZS EZ M2 M1 M0
RAID 1& RAID 10 Mode
OFF
OFF
ON
ON
OFF
1 2 3 4 5
BZS EZ M2 M1 M0
RAID 3 Mode
OFF
OFF
ON
OFF
OFF
1 2 3 4 5
SW1
SW1
SW1
Clone Mode
OFF
OFF
OFF
ON
ON
1 2 3 4 5
BZS EZ M2 M1 M0
Large Mode
OFF
OFF
ON
OFF
ON
1 2 3 4 5
BZS EZ M2 M1 M0
Individual Drives Mode
OFF
OFF
OFF
OFF
OFF
1 2 3 4 5
BZS EZ M2 M1 M0
BZS EZ M2 M1 M0
RAID 5 Mode
OFF
OFF
OFF
ON
OFF
SW1
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
1 2 3 4 5
BZS EZ M2 M1 M0
Page 7
RAID Setting Notes:
RAID 1& RAID 10 Mode
SW1
When 4 drives are connected to the HPM-XU, the 4 drives will be configured as a 4-drive RAID10 array.
1 2 3 4 5
BZS EZ M2 M1 M0
Clone Mode
SW1
1 2 3 4 5
BZS EZ M2 M1 M0
When 2 drives are connected to the HPM-XU, and DIP switch is set to this setting, the 2 drives will be configured as a 2-drive RAID1 array.
Clone’s action is similar to RAID1. However, all of the hard drives will be mirrored. Clone mode is useful especially when users like to copy data from a source hard drive to the drives connected to the HPM-XU.
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
Page 8
Notes on Spare Drives using the Easy RAID Setting (EZ)
When EZ function is ENABLED, the auto-rebuilding to spare drive is automatic. The degraded RAID group will start rebuilding automatically by using the existing spare drive. * Spare drive can be either plugged before RAID building or a new drive can be plug as the spare drive when RAID rebuild is required.
A. Which port acts as a spare drive? The last drive will automatically become the spare drive. For a 3-drive RAID5 with spare: Drives connected to SATA ports 1~3 belong to the active RAID5 array and drive connected to port 4 is the spare. For a 4-drive RAID10 with spare: Drives connected to SATA ports 1~4 belong to the active RAID10 array and drive connected to port 5 is the spare. For a 2-drive RAID1 with spare: Drives connected to SATA ports 1& 4 belong to the active RAID1 array and drive connected to port 5 is the spare. B. When will rebuild action start?
When the raid fails and EZ is enabled, the HPM-XU will automatically rebuild the RAID group using the spare.
When the raid fails and EZ is disabled, the HPM-XU will NOT rebuild the raid group unless you install a good drive to replace the failed drive.
Connecting the Power Cable and Storage Tower to the Computer
a. Connect the power cord provided from the wall outlet to the back of the tower. b. Make sure the power is off (power LED light should be off). c. Connect the eSATA or USB3 cable from the back of the tower to the matching port on the computer.
Back
Power Connecto
Power Switch
a. A main power switch is located at the back of the tower. Turn the switch on. Another auxiliary switch is located on the front of the tower. b. Make sure the power is off on the auxiliary switch (power LED light should be off). c. Power on the tower.
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
Bottom Front
HDD LEDs
r
Power Switch
Page 9
CONTACT US
www.addonics.com
Phone: 408-573-8580 Fax: 408-573-8588 Email: http://www.addonics.com/sales/query/
Loading...