ADC F0064-111 User Manual

Document Title: WiMAX Gen 1 Spécification
REV
Rev 3
Page
1 of 4
1 Purpose
Purpose of this document is to list WiMAX Gen1 System Specifications.
2 Scope
This specification establishes the performance requirements for the WiMAX distributed antenna system (DAS).
3 Responsibility
LGC Wireless is responsible for maintaining this document.
4 System Level Specification
4.1 Operating Frequencies
WiMAX Gen1 will have two frequency bands. This will allow customer to run Band 1 as main band and Band 2 as MIMO. Second, it allows customer to run two independent bands for example one could be sector 1 and other could be sector 2 with same or different frequency.
4.1.1 WiMAX Frequency Band 1:
WiMAX Band 1 has four sub bands that cover Complete WiMAX band from 2496-2690MHz in 60MHz sub bands.
These tables might change based on marketing requirements.
Band
WiMAX B1 2496 - 2556 2496 - 2556 WiMAX B2 2546 - 2606 2546 - 2606 WiMAX B3 2596 - 2656 2596 - 2656 WiMAX B4 2630 - 2690 2630 - 2690
4.1.2 WiMAX Frequency Band 2:
WiMAX Band 2 has four sub bands that cover Complete WiMAX band from 2496-2690MHz in 60MHz sub bands.
Band
WiMAX B1 2496 - 2556 2496 - 2556 WiMAX B2 2546 - 2606 2546 - 2606
Downlink Uplink
RF Passband (MHz) RF Passband (MHz)
Downlink Uplink
RF Passband (MHz) RF Passband (MHz)
When printed or copied, document is for REFERENCE ONLY as of,
03/07/08
LGC Wireless Confidential
Document Title: WiMAX Gen 1 Spécification
REV
Rev 3
Page
2 of 4
WiMAX B3 2596 - 2656 2596 - 2656 WiMAX B4 2630 - 2690 2630 - 2690
4.2 RF Specifications
RF End-to-End Performance
Downlink Uplink
Parameter Units Min Typ Max Min Typ Max
Average System Gain dB 15 15
System Gain Ripple dB 3.0 4.5 3.0 4.5
Output IP3 (SMF) dBm 33 38
Input IP3 (SMF) dBm -10 -5
Output P1dB dBm 25 28
NF 1-1 dB 11 16 NF 1-8 dB 17 21
NF 1- 4 – 32 dB 23 28
Output Noise Floor (SMF) dBm/Hz -100
UL Limiter Level (referenced to input) dBm -33
DL Limiter Level (referenced to output) for EPCS dBm 27
Out-of-Band Spurious Output Levels (Non LO) dBm -13 -13
Passband Spurious Output Levels (Non LO) dBm -36 -85 -75
4.2.1 System Phase Noise Performance
Phase Noise Performance Above 1GHz
Offset (kHz) Typ (dBc/Hz) Max (dBc/Hz)
0.1 60 57 1 73 68.5
10 83 78 30 96.5 92
100 108 104
5 Environmental Specifications:
Parameter Main Hub and Expansion Hub Remote Access Unit
Operating Temperature 0° to +45°C (+32° to +113°F) –25° to +45°C (–13° to +113°F) Non-operating Temperature –20° to +85°C (–4° to +185°F) –25° to +85°C (–13° to +185°F)
When printed or copied, document is for REFERENCE ONLY as of,
03/07/08
LGC Wireless Confidential
Document Title: WiMAX Gen 1 Spécification
REV
Rev 3
Page
3 of 4
Operating Humidity; non-condensing 5% to 95% 5% to 95%
6 Cabling Specifications:
Parameter Specifications
Optical Fiber These specifications assume that the fiber optic cable, single-mode, is Corning with SC/APC connectors.
Optical Power Budget
CATV
CATV Lengths
Uplink and Downlink Maximum: 3 dB Optical power budget between Main Hub and Expansion Hub
The specifications in this document assume that CATV RG-59 cable is CommScope 2065V, CATV RG-6 cable is CommScope 2279V, and CATV RG-11 cable in CommScope 2293K or equivalent, with 75 ohm F connectors.
Minimum: 135 meters Maximum with RG-59 Maximum: 140 meters Maximum with RG-6 Maximum: 235 meters Maximum with RG-11
7 Physical Specifications:
Parameter Main Hub Expansion Hub Remote Access Unit
4 N, female (50 ohms), 1
IF/RF Connectors External Alarm Connector
(contact closure) ADMIN/LAN Interface
Connector
Fiber Connectors 4 Pair, SC/APC 1 Pair, SC/APC
AC Power (Volts)
DC Power (Volts)
Power Consumption (W) 30
Enclosure Dimensions (height ×width ×depth)
Weight < 5.5 kg (< 12 lb) < 6.6 kg (< 14.5 lb) < 2.1 kg (< 4.6 lb)
Downlink / Uplink pair per MIMO Channel
1 9-pin D-sub, female — 1 RJ-45, female 1 9-pin D-
sub, male for optional modem
Rating: 100-240V AC, 1A, 50–60 Hz
Operating Range: 90–132V AC/170–250V AC auto­ranging
Rating/Operating Range: 38-64V DC, 2.5A
89 mm × 438 mm × 381 mm (3.5 in. × 17.25 in. × 15 in.) 2U
8 F, female (CATV -75 ohms)
1 RJ-45, female 1 9-pin D­sub, male
Rating: 100-240V AC, 6A, 50–60 Hz
Operating Range: 90–132V AC/170–250V AC auto­ranging
Rating/Operating Range: 38-64V DC, 14A
4 RAUs: 240 typical, 310 max. 8 RAUs: 400 typical, 530 max. 89 mm × 438 mm × 381 mm (3.5 in. × 17.25 in. × 15 in.) 2U
1 F, female (CATV - 75 ohms) 1 N, female (antenna
- 50 ohms)
54V DC (from the E Hub)
— 54 mm × 286 mm × 281 mm
(2.13 in. × 11.25 in. × 11.13 in.)
When printed or copied, document is for REFERENCE ONLY as of,
03/07/08
LGC Wireless Confidential
Document Title: WiMAX Gen 1 Spécification
REV
Rev 3
Page
4 of 4
Note Section 8 and 9 are for internal use only. They are for ATE configuration.
8 Main Hub TDD Requirements:
TDD Duplex port or Simplex ports will be configured in manufacturing based on customer requirements.
8.1 MH TDD threshold configuration:
Main Hub threshold is configured at ATE. Each band and each Sub Band have different threshold and memory location. MH will switch to Downlink at input power of -10dBm. This is configured at ATE with 0dB System gain. After setting MH gain and calibration threshold, ATE will inject -10dBm signal into MH and measure detector threshold through A/D and program it into assigned memory location. ATE will measure and program this value into each sub band it tests. These steps are repeated for both bands.
9 RAU TDD Threshold Requirements:
9.1 RAU Threshold Configuration
RAU Threshold is set after RAU configuration is done. Each band have different thre shold, and each sub band has different threshold. Band 1 setup: RAU Output power is set to -10dBm and Band 1 Downlink Burst Detector output is measured through A/D and programmed in assigned memory location. Firmware uses this location for Comparator threshold. These steps are repeated for Band 2.
10 RAU and MH Unit
RAU need to be configured to calibrated Pout of 5dBm from RAU. MH need to be configured to +5dBm input Power with 0dB system gain.
11 Change History:
Rev
2 1/3/08 Add Section 8 and 9 TDD Threshold. Baljit Singh 3 2/14/08 Added section 10 Baljit Singh
ECO NO.
Date
Description of Change
Change By
When printed or copied, document is for REFERENCE ONLY as of,
03/07/08
LGC Wireless Confidential
Loading...