ADC ClearGain Dual Inline TMAs User Manual

ClearGain® Dual Inline TMAs
Americas
SPEC SHEET
As mobile usage continues to increase, service providers are faced with the challenge of optimizing and expanding their wireless networks to provide new and existing services. ADC’s ClearGain® Tower-Mounted Amplifiers (TMAs) minimize the cost of network expansion and improve the quality of service, allowing carriers to increase profitability from new and existing services.
ClearGain TMAs improve signal quality by boosting the uplink (RX) signal of a mobile system immediately after the antenna. This compensates for the loss in signal strength that occurs when the signal is passed through the coaxial feeder cable to the base transceiver station (BTS) at the base of the tower. These TMAs perform this amplification with the lowest possible noise contribution, resulting in a substantial increase in receiver performance and an improvement in overall coverage. These improvements in quality of service allow mobile subscribers to place more calls, make longer calls, and successfully complete calls in an expanded geographic area, resulting in increased revenue.
Benefits:
• Small size and low weight. Allows for easy installation with minimal visual impact and in weight-restricted implementations.
• Improved uplink coverage. TMAs enable base stations to receive mobile signals more clearly in a wider coverage area than could otherwise be achieved.
• Increased RF performance. By improving signal quality and/or reducing mobile phone power transmission, TMAs provide more successful call attempts, a reduction in dropped calls, maximized data rate, improved call quality and the extension of handset battery life.
• Fully AISG compliant.
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
ClearGain® Dual Inline TMAs
+ -
INPUT
NO COM NC
ALARM
MHU
DISCONNECT
Power Distribution Unit
MHU1 MHU2 MHU3
Base
Station
Tower­Mounted Amplifier
Bias-T
BTS
Americas
The ClearGain Dual Inline AWS TMA allows for mounting of the equipment to serve two RX paths in one location on the tower, reducing time and expense in mounting the TMA. The inline feature also allows for easier connection of the jumper cables to the antenna.
A ClearGain TMA system is modular, consisting of both a masthead unit (MHU) and a power distribution unit (PDU), providing full compatibility with all base stations. Due to its exposed installation, the TMA is designed to withstand demanding weather conditions and features lightning protection, fault monitoring, and a fail-safe bypass circuitry system.
ClearGain Dual Inline TMAs
8 / 0 7 • 1 0 5 1 8 8 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
2
ClearGain® Dual Inline TMAs
Americas
AWS Dual Inline Typical Specifications
ELECTRICAL Nominal Impedance of RF Inputs and Outputs: Frequency Range TX: 2110 – 2155MHz RX: 1710 – 1755MHz Passband (RX) Gain: 12db Noise Figure: 1.4dB Dynamic Range: Input at 1 DB Gain Compression: +13dBm 0utput IP3: +25dBm Bypass Insertion Loss: 2.0dB Isolation in Tx Path: >50dB Insertion Loss of TX Path (TX to ANT): Passband Return Loss Tx Band: 18dB Rx Band: 18dB Rx Rejection in Tx Band: >75dB
PHYSICAL Dimensions (HxWxD): Weight: Housing:
50 Ohm
0.5dB
210 mm x 166 mm x 81 mm
4.5kg Aluminium
CONNECTORS Antenna Connector: BTS Connector:
ENVIRONMENTAL Operating Temperature: Lightning Protection: ANT Port 10kA 8/20us
ClearGain Dual Inline TMAs
VIBRATION Storage: Transport: Operation:
REGULATORY EMC: ETS 300 342-3
APPROVALS AISG: AISG 1.1 CE: Per IEC 61000 and IEC 60950
QUALITY MTBF: 500,000 hours
8 / 0 7 • 1 0 5 1 8 8 A E
7/16 DIN Female 7/16 DIN Female
-40°C to +60°C BTS Port 10kA 8/20us
ETS3019-1-1 ETS3019-1-2 ETS3019-1-4 Class 4.1E
ADC is an active member
of the Antenna Interface
Standard Group.
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
ClearGain® Dual Inline TMAs
Americas
STRB-NF-NM-G-KIT STRB-NM-NF-G-KIT STRB-DM-DF-G-KIT STRB-DF-DM-G-KIT
Bias-T Units
ADC’s newly enhanced Bias-T Units can be used indoors and outdoors in conjunction with the ClearGain power distribution unit (PDU). These versatile units, also known as DC current injectors, insert DC power into the coaxial cable and extract alarm and monitoring signals from the coaxial cable.
PRODUCT CONFIGURATION Main path connectors: DC injection/Sample port connector: Mounting and grounding:
M - screw / brk - bracket)
Refer to ordering information for configurations
TNC jack (female)
/M8 / brk (MH - bulkhead mounting/
TECHNICAL DATA
ClearGain Dual Inline TMAs
Impedance: Frequency range: Return loss: Insertion loss: RF CW power: PIM 3rd order: Surge current handling capability: Operating temperature: Waterproof degree: DC injection / DC bypass current: DC supply / DC bypass voltage: MTBF: Size: (4.9 in x 4.3 in x 1.8 in) Weight:
50 ohms 800 to 2200 MHz > 19 dB < 0.2 dB 500 W
-108 dBm 3kA single
-40°C to + 65°C IP 65 < 2 A < 48 V 600,000 hours 125 mm x 110 mm x 45 mm
0.8 kg (1.8 lbs.)
8 / 0 7 • 1 0 5 1 8 8 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
4
ClearGain® Dual Inline TMAs
Americas
Dual Inline Power Distribution Unit
Time and space are important considerations when selecting and installing wireless components at base transceiver station sites. The simple, compact design of ADC’s ClearGain Power Distribution Unit (PDU) is intended to help service providers save both. From a compact unit that is easily mounted on a wall or in a rack, the ClearGain PDU provides power and alarming for up to three ClearGain Tower-Mounted Amplifiers.
ClearGain Dual Inline TMAs
Features:
• Provides power and alarm functions for on-site monitoring of up to three dual-inline masthead units (MHUs)
• Monitors condition of feeder cable
• Wall or rack-mountable to fit available space
• LED indicators for alarm functions
• Simple, compact design allows for easy installation and connections
• AISG compliant
The ClearGain Dual Inline TMA system is modular, consisting of an MHU and a PDU, providing full compatibility with all base stations.
The ClearGain Dual Inline PDU is an integrated unit that provides power and alarm functions for the ClearGain TMA system. The PDU monitors the current of the MHU. If an MHU fails, the ClearGain Dual Inline PDU gives an alarm indication. The ClearGain Dual Inline PDU also monitors the condition of the feeder cable. Alarm indicators identify failure in the feeder cable or MHUs and in which MHU the failure occurred, providing fast and easy on-site diagnostics.
The flexible design of the ClearGain Dual Inline PDU allows it to be rack-mounted or mounted indoors on the wall or on the side of a BTS cabinet.
An external Bias-T unit is used in conjunction with the Dual Inline PDU and is designed to connect directly into the BTS coaxial connector. Bias-T units are available with various connector types, with gas tube arrestors for lightning protection on the ANT and MHU ports. Quarter wave stub lightning protection is integrated on the BTS port of the Bias-T units.
8 / 0 7 • 1 0 5 1 8 8 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
5
ClearGain Dual Inline TMAs
ClearGain® Dual Inline TMAs
Americas
Dual Inline Power Distribution Unit Typical Specifications
ELECTRICAL Input Voltage: Output Voltage: Maximum Current Draw: PHYSICAL Dimensions (HxWxD): Weight: Color: CONNECTORS Output for MHUs: Power Connector: General Alarm Connector: General Communications Connector:
INDICATORS Red General Alarm LED
ALARM OUTPUT connection. Normally open and normally closed connection available. ENVIRONMENT Storage: Transportation: Operation: Housing: Temperature Range (Indoor Use): Lightning Protection: APPROVALS QUALITY Manufactured under ISO 9001 quality system ACCESSORIES Basic Accessories: Power supply cable (10 m), alarm cable (10 m),
communications cable (10 m), grounding cable (2 m)
and wall mounting screws
Optional Accessories: Mounting hardware for 19” rack mount
Green OK/NOK LEDs
Alarm output is isolated 3-pin relay
CE
MTBF 250,000
20-56 Vdc positive/negative ground 3x16 Vdc each 3A
43 x 196 x 103 mm 1 kg Silver
SMB, male (qty 3) 4-pin male 3-pin male 3-pin male
ETS3019-1-1 ETS3019-1-2 ETS3019-1-3 IP40
-20°C to +65°C IEC 1000-4-5 EMC
ADC is an active member
of the Antenna Interface
Standard Group.
O r d e r i n g I n f o r m a t i o n
Description Catalog Number
ClearGain Masthead Unit
Bias-T Kits*
8 / 0 7 • 1 0 5 1 8 8 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
7/16 DIN male to BTS, 7/16 DIN female to ANT STRB-DM-DF-G-KIT
7/16 DIN female to BTS, 7/16 DIN male to ANT STRB-DF-DM-G-KIT
N female to BTS, N male to ANT STRB-NF-NM-G-KIT
N male to BTS, N female to ANT STRB-NM-NF-G-KIT
Dual Inline Power Distribution Unit – Includes power cable and grounding cable CG0000000000PFM
*Bias-T, DC Cable 4.25 meters (SMB to TNC), Grounding Cable 1.5 meters (one end terminated) Approved for use with ADC supplied Masthead Units only.
CG0AWSDD155DT00
6
ClearGain® Dual Inline TMAs
Americas
Creating a Bill of Materials
A typical site includes three components in various quantities.
You have one TMA option:
1. CG0AWSDDI55DT00 AWS Dual Inline TMA
ClearGain Dual Inline TMAs
The TMAs include: • Mounting hardware
• Grounding cable/strap (length 1
Ordering information: Order one per sector
You have four Bias-T options (based on connector type and orientation):
1. STRB-DF-DM-G-KIT DIN Female to BTS Port, DIN Male to ANT Port
2. STRB-DM-DF-G-KIT DIN Male to BTS Port, DIN Female to ANT Port
3. STRB-NF-NM-G-KIT N Female to BTS Port, N Male to ANT Port
4. STRB-NM-NF-G-KIT N Male to BTS Port, N Female to ANT Port
The Bias-Ts include:
Ordering information: Order one per sector
You have one PDU option:
1. CG0000000000PFM Dual Inline PDU
The PDU includes: • Mounting Hardware
Ordering information: Order one per site
• Grounding cable/strap (length 1.5 meters)
• Bias-T cable; go from Bias-T to the PDU (length 14 feet)
• Power Cable (length 10 meters)
• Alarm Cable (length 10 meters)
• Grounding Cable/strap (length 1.5 meters)
.5 meters)
Optional Accessories:
Longer Bias-T Cable CG-PDU-30CABLE (30 foot Bias-T cable) PDU Rack Mounting Brackets AUX-000076 (19" rack mounting bracket) AUX-000076 & EB-17P (23" mounting bracket) AUX-000084 (Siemens cabinet mounting bracket)
8 / 0 7 • 1 0 5 1 8 8 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
7
SPEC SHEET
Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
105188AE 8/07 Original © 2007 ADC Telecommunications, Inc. All Rights Reserved
Loading...