ADC 4-Pair Riser User Manual

Basic Structured Cabling Systems
Category 5e 4-Pair Riser Data Cable
ADC’s Basic Category 5e and Category 6 Structured Cabling Systems are complete channel solutions offering 20-year product performance warranties along with a multitude of product choices and design options. In addition, the components of these economical systems are also guaranteed to meet the minimum requirements of TIA 568B for Category 5e and Category 6 for dependable data transmission in any network configuration, from the switch to the network interface.
Spec Sheet
Features:
• Unparalleled delay skew performance
• Manufactured with lead-free materials
Compliances:
• UL Subject 444
• (UL)-C(UL) Type CMR/CMG
• (UL)-C(UL) Type CM/CMH
• ICEA S-90-661
• NEC 800 Type CMR or CM
• ISO/IEC 11801 Class D
• ETL verified TIA/EIA-568-B.2 Category 5e horizontal cable requirements
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Basic Structured Cabling Systems
Freq
(MHz)
Fitted
Impedance
(Ohms)
Insertion Loss
(dB/100m)
Return Loss
(dB/100m)
Pair-Pair NEXT
(dB/100m)
PSNEXT
(dB/100m)
Spec Max Spec Min Spec Min Spec Min Spec
1 100 +/- 15 1.9 2.0 30.1 20.0 73.4 65.3 70.9 62.3
4 100 +/- 15 3.9 4.1 27.5 23.0 66.7 56.3 65.0 53.3
8 100 +/- 15 5.5 5.8 31.3 24.5 61.5 51.8 59.7 48.8
10 100 +/- 15 6.2 6.5 28.6 25.0 60.1 50.3 57.6 47.3
16 100 +/- 15 7.8 8.2 31.2 25.0 53.8 47.2 52.9 44.2
20 100 +/- 15 8.8 9.3 30.8 25.0 57.5 45.8 54.5 42.8
25 100 +/- 15 9.9 10.4 30.5 24.3 52.3 44.3 53.0 41.3
31.25 100 +/- 15 11.0 11.7 31.2 23.6 49.4 42.9 47.3 39.9
62.5 100 +/- 15 15.8 17.0 27.6 21.5 46.6 38.4 44.4 35.4
100 100 +/- 15 20.2 22.0 23.0 20.1 45.3 35.3 42.6 32.3
155 100 +/- 15 25.4 –– 23.0 –– 45.3 –– 40.4 ––
Category 5e 4-Pair Riser Data Cable
Specifications
CONSTRUCTION Conductors: 24 AWG solid bare copper Insulation: Polyolefin Pairing: Short, staggered pair lays Jacket: Lead-free, flame retardant PVC Nominal outer diameter: 4.7 mm (.185")
ELECTRICAL CHARACTERISTICS Conductor DC resistance (maximum): 9.38 Ω/100 meters (28.6 Ω/1000 ft) @ 20 °C (68 °F) DC resistance unbalance (maximum): 2% Mutual capacitance (maximum): 5.6 nF/100 meters (17 pF/ft) Operating temperature (maximum): 75 °C (167 °F) Operating voltage (maximum): 300 VDC Worst case cable skew: 25 nS/100 meters (25 nS/328 ft) Nominal velocity of propagation: 69%
Category 5e 4-Pair Riser Data Cable
1 0 / 0 6 • 1 0 1 8 4 8 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
2