Adaptec 1220SA, 1225SA, 1420SA, 44300, 1430SA User Manual

...
Page 1
SAS and SATA
HostRAID Controller
Installation and User’s Guide
Page 2
2
Copyright
©2007 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035.
Adaptec, Adaptec Storage Manager, SCSISelect, SATASelect, SerialSelect and the Adaptec logo are trademarks of Adaptec, Inc., which may be registered in some jurisdictions.
Microsoft and Windows are trademarks of Microsoft Corporation in the US and other countries, used under license.
Red Hat is a trademark of Red Hat, Inc. in the US and other countries, used under license.
Novell and NetWare are trademarks of Novell, Inc. in the US and other countries, used under license.
All other trademarks are the property of their respective owners.
Changes
The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Adaptec, Inc. assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein.
Adaptec reserves the right to make changes in the product design without reservation and without notification to its users.
Disclaimer
IF THIS PRODUCT DIRECTS YOU TO COPY MATERIALS, YOU MUST HAVE PERMISSION FROM THE COPYRIGHT OWNER OF THE MATERIALS TO AVOID VIOLATING THE LAW WHICH COULD RESULT IN DAMAGES OR OTHER REMEDIES.
Page 3
3
Adaptec Customer Support
If you have questions about installing or using your Adaptec product, check this document first—you will find answers to most of your questions. If you need further assistance, use the support options listed below. To expedite your service, have your computer in front of you.
Technical Support Identification (TSID) Number
Before contacting Technical Support, you need your unique 12-digit TSID number. The TSID number identifies your product
and support status.
The TSID number is included on a white, bar-coded label, like this example:
Affix a copy of the TSID label to the CD jacket so that you don’t lose it.
North America
Visit our Web site at www.adaptec.com.
Search the Adaptec Support Knowledgebase (ASK) at ask.adaptec.com for articles, troubleshooting tips, and frequently asked
questions for your product.
For information about Adaptec’s support options, call +1 408-957-2550, 24 hours per day, 7 days per week. To speak with a Technical Support Specialist, call +1 408-934-7274 or +1 321-207-2000.
For support via e-mail, submit your question at ask.adaptec.com.
You can order Adaptec products, including accessories and cables, by calling +1 408-957-7274.
www.adaptec.com.
Europe
Visit our Web site at www.adaptec.com.
German: Call +49 89 43 66 55 22, Monday to Friday, 9:00 to 17:00, CET. For support via e-mail, submit your question at
ask-de.adaptec.com.
French: Call +49 89 43 66 55 33, Monday to Friday, 9:00 to 17:00, CET. For support via e-mail, submit your question at
ask-fr.adaptec.com.
English: Call +49 89 43 66 55 44, Monday to Friday, 9:00 to 17:00, GMT. For support via e-mail, submit your question at
ask.adaptec.com.
You can order Adaptec cables online at www.adaptec.com.
Japan
Visit our Web site at www.adaptec.co.jp.
Call 0044 2213 2601.
Or, you can order cables online at
Page 4
4
Limited 3-Year Hardware Warranty
1. Adaptec, Inc. (“Adaptec”) warrants to the purchaser of this product that it will be free from defects in material and workmanship for a period of three (3) years from the date of purchase. If the product should become defective within the warranty period, Adaptec, at its option, will repair or replace the product, or refund the purchaser’s purchase price for the product, provided it is delivered at the purchaser’s expense to an authorized Adaptec service facility or to Adaptec.
2. Repair or replacement parts or products will be furnished on an exchange basis and will either be new or reconditioned. All replaced parts or products shall become the property of Adaptec. This warranty shall not apply if the product has been damaged by accident, misuse, abuse or as a result of unauthorized service or parts.
3.
Warranty service is available to the purchaser by delivering the product during the warranty period to an authorized Adaptec service facility or to Adaptec and providing proof of purchase price and date. The purchaser shall bear all shipping, packing and insurance costs and all other costs, excluding labor and parts, necessary to effectuate repair, replacement or refund under this warranty
4. For more information on how to obtain warranty service, write or telephone Adaptec at 691 South Milpitas Boulevard, Milpitas, CA 95035, (800) 959-7274.
5. THIS LIMITED WARRANTY DOES NOT EXTEND TO ANY PRODUCT WHICH HAS BEEN DAMAGED AS A RESULT OF ACCIDENT, MISUSE, ABUSE, OR AS A RESULT OF UNAUTHORIZED SERVICE OR PARTS.
6.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES WHICH NOW OR HEREAFTER MIGHT OTHERWISE ARISE RESPECT TO THIS PRODUCT. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT SHALL (A) HAVE NO GREATER DURATION THAN 3 YEARS FROM THE DATE OF PURCHASE, (B) TERMINATE AUTOMATICALLY AT THE EXPIRATION OF SUCH PERIOD AND (C) TO THE EXTENT PERMITTED BY LAW BE EXCLUDED. IN THE EVENT THIS PRODUCT BECOMES DEFECTIVE DURING THE WARRANTY PERIOD, THE PURCHASER’S EXCLUSIVE REMEDY SHALL BE REPAIR, REPLACEMENT OR REFUND AS PROVIDED ABOVE. INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION LOSS OF DATA, ARISING FROM BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ARE NOT THE RESPONSIBILITY OF ADAPTEC AND, TO THE EXTENT PERMITTED BY LAW, ARE HEREBY EXCLUDED BOTH FOR PROPERTY DAMAGE, AND TO THE EXTENT NOT UNCONSCIONABLE, FOR PERSONAL INJURY DAMAGE
7. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS, AND SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU.
8. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
.
.
Page 5
5
Tes ted to Comply With FC C Standard s
FOR HOME OR OFFICE USE
ASR-58300/ASR-48300/ASR-44300
AAR-1430SA/AAR-1420SA/
AAR-1220SA/AAR-1225SA
Adaptec, Inc.
Regulatory Compliance Statements
Federal Communications Commission Radio Frequency Interference Statement
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. However, if this equipment does cause interference to radio or television equipment reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/television technician for help.
Use a shielded and properly grounded I/O cable and power cable to ensure compliance of this unit to the specified limits of the
rules.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
European Union Compliance Statement
This Information Technology Equipment has been tested and found to comply with EMC Directive 89/336/EEC, as amended by 92/31/EEC and 93/68/EEC, in accordance with:
EN55022 (1998+A1:2000+A2:2003) Emissions
EN55024 (1998+A1:2001+A2:2003) Immunity:
– EN61000-4-2 (1995) Electrostatic discharge: ±4 kV contact, ±8 kV air – EN61000-4-3 (1996) Radiated immunity – EN61000-4-4 (1995) Electrical fast transients/burst: ±1 kV AC, ±0.5 kV I/O – EN61000-4-5 (1995) Surges ±1 kV differential mode, ±2 kV common mode – EN61000-4-6 (1996) Conducted immunity: 3 V – EN61000-4-11 (1994) Supply dips and variation: 30% and 100%
In addition, all equipment requiring U.L. listing has been found to comply with EMC Directive 73/23/EEC as amended by 93/68/EEC in accordance with EN60950 with amendments A1, A2, A3, A4, A11.
Australian/New Zealand Compliance Statement
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to the Australian/New Zealand standard AS/NZS 3548 set out by the Spectrum Management Agency.
Canadian Compliance Statement
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Japanese Compliance (Voluntary Control Council Initiative)
This equipment complies to class B Information Technology equipment based on VCCI (Voluntary Control Council for Interface). This equipment is designed for home use but it may causes radio frequency interference problem if used too near to a television or radio. Please handle it correctly per this documentation.
Page 6

Contents

1 About This Guide
What You Need to Know Before You Begin ................................................... 12
Terminology Used in this Guide...................................................................... 12
Conventions Used in This Guide ..................................................................... 12
How to Find More Information....................................................................... 12
2 About Your HostRAID Controller
HostRAID Controller Features ........................................................................ 15
Array Level Features................................................................................. 15
About the Adaptec 58300 Controller............................................................... 17
About the Adaptec 48300 Controller............................................................... 18
About the Adaptec 44300 Controller............................................................... 19
About the Adaptec 1430SA Controller ............................................................ 20
About the Adaptec 1420SA Controller ............................................................ 21
About the Adaptec 1220SA Controller ............................................................ 22
About the Adaptec 1225SA Controller ............................................................ 23
3 Kit Contents and System Requirements
Kit Contents ...................................................................................................... 25
System Requirements........................................................................................ 25
4 Installing the HostRAID Controller and Disk Drives
Before You Begin............................................................................................... 27
Installing the HostRAID Controller................................................................. 27
Selecting Disk Drives ........................................................................................ 28
Selecting SAS Cables .........................................................................................28
Page 7
Contents 7
Selecting SATA Cables ...................................................................................... 30
Connecting Disk Drives to SAS HostRAID Controllers ................................. 30
Connecting Directly to the HostRAID Controller .................................31
Connecting to a Backplane ...................................................................... 31
Installing the SAS HostRAID Controller to a SAS Expander ................ 32
Connecting Disk Drives to SATA HostRAID Controllers.............................. 32
Checking Your Controller and Devices ........................................................... 33
Setting the Boot Controller .............................................................................. 33
Next Steps.......................................................................................................... 34
5 Getting Started
Choosing a RAID Level..................................................................................... 36
Choosing Installation Options ......................................................................... 36
Basic Installation Steps...................................................................................... 36
Installing with an Operating System ....................................................... 36
Installing with an Operating System On a Bootable Disk Drive/Array. 36
Installing on an Existing Operating System............................................ 37
6 Creating a Bootable Array
Creating an Array.............................................................................................. 39
Creating an Array with the ACU ............................................................. 39
Creating an Array with Adaptec Storage Manager................................. 39
Making Your Array Bootable ...........................................................................41
7 Installing the Driver and an Operating System
Before You Begin............................................................................................... 43
Creating a Driver Disk ...................................................................................... 43
Installing with Windows................................................................................... 43
Installing with Red Hat Linux .......................................................................... 44
Installing with SUSE Linux............................................................................... 44
Installing with NetWare.................................................................................... 45
8 Installing the Driver on an Existing Operating System
Before You Begin............................................................................................... 47
Creating a Driver Disk or an Array .................................................................. 47
Installing on Windows XP or Windows 2003 .................................................47
Installing on Windows Vista ............................................................................48
Installing on Red Hat or SUSE Linux ..............................................................48
Installing on NetWare....................................................................................... 48
Page 8
Contents 8
9 Managing Your Storage Space
About Adaptec Storage Manager ..................................................................... 51
Installing Adaptec Storage Manager........................................................ 51
About the HRCONF Command Line Utility .................................................. 51
About the ARC Utility ......................................................................................52
About the Adaptec Flash Utility....................................................................... 52
Which Utility Should I Use?............................................................................. 52
10 Solving Problems
Troubleshooting Checklist ............................................................................... 54
Recovering from a Disk Drive Failure ............................................................. 54
Failed Disk Drive Protected by a Hot Spare ........................................... 54
Failed Disk Drive Not Protected by a Hot Spare .................................... 54
Failure in Multiple Arrays Simultaneously ............................................. 55
Disk Drive Failure in a RAID 0 Array .....................................................55
Multiple Failures in the Same Array........................................................ 55
Resetting the Controller.................................................................................... 55
A Introduction to SAS
Terminology Used in This Appendix............................................................... 58
What is SAS?...................................................................................................... 58
How Do SAS Devices Communicate?.............................................................. 59
What’s a Phy? .................................................................................................... 59
What’s a SAS Port?............................................................................................ 59
What’s a SAS Address?...................................................................................... 60
What’s a SAS Connector? .................................................................................60
What do SAS Cables Look Like?....................................................................... 60
How are Disk Drives Identified in SAS? .......................................................... 60
What are the SAS Connection Options?.......................................................... 61
Direct-Attach Connections...................................................................... 61
Backplane Connections............................................................................ 61
SAS Expander Connections ..................................................................... 61
How is SAS Different from Parallel SCSI? ....................................................... 62
BUnderstanding RAID
RAID Technology Overview............................................................................. 65
Understanding Drive Segments............................................................... 65
Stripe-Unit Size ........................................................................................ 65
RAID 0 (Non-RAID Arrays) ............................................................................ 65
RAID 1 Arrays ................................................................................................... 66
Page 9
Contents 9
RAID 10 Arrays ................................................................................................. 66
Selecting the Best RAID Level .......................................................................... 67
C Using the ARC Utility
Introduction to the ARC Utility....................................................................... 69
Running the ARC Utility .................................................................................. 69
Creating and Managing Arrays ........................................................................ 69
Creating a New Array............................................................................... 69
Managing Arrays ......................................................................................71
Adding/Deleting Hot Spares.................................................................... 72
Managing Bootable Arrays and Devices.................................................. 73
Configuring Disk Drives .......................................................................... 73
ATAPI Support......................................................................................... 73
Using SerialSelect............................................................................................... 73
SerialSelect Options .................................................................................. 74
Using SATASelect .............................................................................................. 75
SATASelect Options.................................................................................. 76
Formatting and Verifying Disk Drives............................................................. 76
Locating Disk Drives......................................................................................... 77
Identifying Disk Drives..................................................................................... 77
Viewing the Event Log ...................................................................................... 78
D Using the Adaptec Flash Utility for DOS
Introduction ...................................................................................................... 80
System Requirements........................................................................................ 80
Compatibility Information............................................................................... 80
Before You Begin............................................................................................... 80
Obtaining the Firmware........................................................................... 80
Creating the Firmware Kit On Floppy Disks .......................................... 81
Running the AFU .............................................................................................. 81
Running the Menu-Based AFU ............................................................... 81
Running the AFU from the Command Line .......................................... 82
AFU Commands ............................................................................................... 82
HELP......................................................................................................... 82
LIST........................................................................................................... 83
SAVE ......................................................................................................... 83
UPDATE ................................................................................................... 84
VERIFY .....................................................................................................84
VERSION.................................................................................................. 85
Updating Flash Using AFU Command Line ...................................................85
Page 10
Contents 10
E HostRAID Controller LED and I2C Connector Reference
Adaptec 58300 Activity LED Connector Specification ...................................88
Adaptec 48300 Activity LED Connector Specification ...................................88
Adaptec 44300 Activity LED Connector Specification ...................................89
Adaptec 1430SA Activity LED and I2C Connector Specification ..................89
Adaptec 1420SA Activity LED and I2C Connector Specification ..................90
Adaptec 1220SA Activity LED Connector Specification................................. 91
Adaptec 1225SA Activity LED Specification ................................................... 91
F Safety Information
Electrostatic Discharge(ESD) ...........................................................................92
G Technical Specifications
Environmental Specifications........................................................................... 94
DC Power Requirements .................................................................................. 94
Current Requirements ..................................................................................... 94
Glossary
Index
Page 11

About This Guide

In this chapter...
What You Need to Know Before You Begin .......................................................................... 12
Terminology Used in this Guide............................................................................................ 12
Conventions Used in This Guide........................................................................................... 12
How to Find More Information ............................................................................................ 12
1
This Installation and User’s Guide explains how to install your Adaptec It also describes the utilities included in your controller kit , and provides a basic overview of Serial Attached SCSI (SAS) technology.
®
HostRAID controller.
Page 12

What You Need to Know Before You Begin

You should be familiar with computer hardware, data storage, Redundant Array of Independent Disks (RAID) technology, and the characteristics of input/output (I/O) technology used by your HostRAID controller. Because SAS is a newer I/O technology, an introduction is provided in the Appendix A.
Because this guide covers multiple Adaptec HostRAID controllers, some of the features and
Note:
functions described may not be available for your controller.

Terminology Used in this Guide

Because you can use your HostRAID controller to manage data storage in a variety of configurations from DAS to NAS to SAN, the generic term “storage space is used to refer to controllers and disk drives being managed with Adaptec Storage Manager utilities described in this Guide.
Many of the terms and concepts referred to in this Guide have multiple names. To maintain consistency, they are represented as:
Controller (also known as host bus adapter, board)
Chapter 1: About This Guide l12
TM
or the other
Disk drive (also known as hard disk, hard drive, or hard disk drive)
Array (also known as logical drive)
In DAS environments, Adaptec Storage Manager User’s Guide refers to arrays as logical
Note:
drives. Your RAID controller creates arrays, which your operating system and Adaptec Storage Manager recognizes as logical drives. In NAS environments, Adaptec Storage Manager displays both arrays and logical drives. For more information, refer to the Adaptec Storage Manager User's Guide for Direct Attached Storage on the Adaptec Storage Manager Installation CD.

Conventions Used in This Guide

In this documentation, the term SAS-only means that the requirement, feature, or procedure is applicable only to SAS HostRAID controllers.
The term SATA-only means that the requirement, feature, or procedure is applicable only to SATA HostRAID controllers.

How to Find More Information

You can find more information about your HostRAID controller, and the software and utilities included with it in these documents:
Readme.txt—Describes details about updated product information and known issues;
located on the HostRAID Installation CD.
Adaptec Storage Manager User’s Guide—Describes how to install and use the Adaptec
Storage Manager software located on the Adaptec Storage Manager Installation CD. See
Managing Your Storage Space on page 50 for more information.
Adaptec Storage Manager online Help—Describes how to use the Adaptec Storage Manager
software.
Command Line Utility for Direct Attached Storage User’s Guide—Describes how to use the
Adaptec HostRAID Controller Configuration (HRCONF) command line utility to
Page 13
Chapter 1: About This Guide l13
perform basic array and configuration management functions; located on the Adaptec Storage Manager Installation CD.
Page 14

About Your HostRAID Controller

In this chapter...
HostRAID Controller Features.............................................................................................. 15
About the Adaptec 58300 Controller .................................................................................... 17
About the Adaptec 48300 Controller .................................................................................... 18
About the Adaptec 44300 Controller .................................................................................... 19
About the Adaptec 1430SA Controller.................................................................................. 20
About the Adaptec 1420SA Controller.................................................................................. 21
About the Adaptec 1220SA Controller.................................................................................. 22
About the Adaptec 1225SA Controller.................................................................................. 23
This chapter provides an overview of standard HostRAID controller features, and describes the unique features of Adaptec SAS and SATA HostRAID controllers.
2
Page 15

HostRAID Controller Features

Port multiplier support— You can connect one SATA drive enclosure with a port
multiplier to 1225SA HostRAID controller.
To find out the version of the port multiplier, refer to the drive enclosure documentation.
Note:
Adaptec supports SiI3726 with one 3 Gbps SATA II host interface and five SATA device ports. We support only 3Gbps NCQ enabled drives.
NetWare does not support drive enclosures with port multipliers but supports eSATA drives.
Note:
Greater than 2 TB support—You can create and manage HostRAID arrays which are bigger
than 2TB size. Hence,users can use the current and future high capacity hard disk drives above 750GB.
Flash ROM for updates to controller firmware.
Event logging and broadcasting, including messaging for alphanumeric pagers.
Support for Adaptec Metadata Format (AMF) allowing the migration of simple volumes
and arrays to Adaptec RAID controllers.
Chapter 2: About Your HostRAID Controller l15
Multiple options for creating and managing RAID arrays—A full software application
(Adaptec Storage Manager), a BIOS-based utility, and a command line utility. See
Managing Your Storage Space on page 50 for more information.
Support for disk drive hot swapping.
Support for disk drive enclosures with SAF-TE enclosure management hardware.

Array Level Features

Support for RAID 0, 1, 10, and simple volumes with these HostRAID limitations:
RAID 0: support for max. six drives with SAS and max. four drives with SATA
RAID 10: support for max. four drives
RAID 1 is build with two drives always
The maximum number of arrays per controller is two.
The maximum number of global hot spares per controller is one.
Hot swap rebuild of fault tolerant arrays through the operating system.
Support for automatic failover, so arrays are automatically rebuilt when a failed disk drive
is replaced (applies to redundant arrays in SES2- or SAF-TE-enabled disk drive enclosures only).
Global hot spare protecting every fault tolerant array that the drive has enough available
capacity to protect.
Support for migration:
Simple Volume to RAID 0
Simple Volume to RAID 1
(SATA-only) Native command queuing (NCQ), which lets disk drives arrange commands
into the most efficient order for optimum performance.
Page 16
Chapter 2: About Your HostRAID Controller l16
(SAS-only) Support for disk drive enclosures with SES2 enclosure management hardware.
Page 17
Chapter 2: About Your HostRAID Controller l17
External miniSAS Connectors
3.3V PCI-X Connector
Mounting bracket
J3 (Aggregate Activity LED Header)

About the Adaptec 58300 Controller

The Adaptec 58300 is a low-profile PCI-X to 8-Phy SAS 1.0 HostRAID controller with these features:
Drive LEDs
Formx factor Low-profile
Bus compatibility PCI-X
PCI bus width (max) 64-bit
PCI bus speed (max) 133 MHz
PHYs 8
Connectors, internal None
Connectors, external 2 x4 external SFF 8088 (miniSAS)
RAID levels 0, 1, 10
Simple volume Yes
Disk drives SAS (3.0Gb/s), SATA I (1.5Gb/s),
Maximum number of disk drives 8 direct-attached drives or up to 128
Hot spares Yes
Enclosure support Yes
Native Command Queuing (NCQ) No
Automatic failover Yes
Audible alarm No
miniSAS 1.0 connector
SATA II 3.0Gb/s)
using expander technology
Note:
There is NO I2C function on this controller, as all ports are external.
Page 18
Chapter 2: About Your HostRAID Controller l18
External SAS Connector
Internal SAS Connector
3.3V PCI-X Connector
Mounting bracket
J3 (Aggregate Activity LED Header)

About the Adaptec 48300 Controller

The Adaptec 48300 is a low-profile PCI-X to 8-Phy SAS 1.0 HostRAID controller with these features:
Form factor Low-profile
Bus compatibility PCI-X
PCI bus width (max) 64-bit
PCI bus speed (max) 133 MHz
PHYs 8
Connectors, internal 1 x4 internal SFF-8484
Connectors, external 1 x4 external SFF-8470
RAID levels 0, 1, 10
Simple volume Yes
Disk drives SAS (3.0Gbps), SATA I (1.5Gbps),
Maximum number of disk drives 8 direct-attached drives or up to 128
Hot spares Yes
Enclosure support Yes
Native Command Queuing (NCQ) No
Automatic failover Yes
Audible alarm No
SAS 1.1 connector
SAS 1.0 connector
SATA II (3.0Gbps)
using expander technology
Note:
Reference on page 87 for details.
There is no separate I2C connector. See the HostRAID Controller LED and I2C Connector
Page 19
Chapter 2: About Your HostRAID Controller l19
Internal SAS Connector
J3 (Aggregate Activity LED Header)
3.3V PCI-X Connector
Mounting bracket

About the Adaptec 44300 Controller

The Adaptec 44300 is a low-profile PCI-X to 4-Phy SAS 1.0 HostRAID controller with these features:
Form factor Low-profile
Bus compatibility PCI-X
PCI bus width (max) 64-bit
PCI bus speed (max) 133 MHz
PHYs 4
Connectors, internal 1 x4 internal SFF-8484
RAID levels 0, 1, 10
Simple Volume Yes
Disk drives SAS (3.0Gbps), SATA I (1.5Gbps),
Maximum number of disk drives 4 direct-attached drives or up to 128
Hot spares Yes
Enclosure support Yes
Native Command Queuing (NCQ) No
Automatic failover Yes
Audible alarm No
Note:
Reference on page 87 for details.
SAS 1.1 connector
SATA II (3.0Gbps)
using expanded technology
There is no separate I2C connector. See the HostRAID Controller LED and I2C Connector
Page 20
Chapter 2: About Your HostRAID Controller l20
J2 Connector (I2C)
J3 (Aggregate Activity LED Header)
J4 Activity LED
Power LED
Aggregate LED
Port Activity LED
3 (top port)
2 (bottom port)
1 (top port)
0 (bottom port)
SATA Ports
J1 LED Connector
PCIe X4 connector
Mounting bracket

About the Adaptec 1430SA Controller

The Adaptec 1430SA is a low-profile 4-port PCIe SATA II HostRAID controller with these features:
Form factor Low-profile
Bus compatibility PCIe x4
Ports 4
Connectors, internal 4 stacked
RAID levels 0, 1, 10
Simple volume Yes
Disk drives SATA I (1.5Gbps), SATA II (3.0Gbps)
Maximum number of disk drives 4
Hot spares Yes
Enclosure support Yes, SATA II Enclosure Management using
Native Command Queuing (NCQ) Yes
Automatic failover Yes
Audible alarm No
Note:
Reference on page 87 for details.
There is no separate I2C connector. See the HostRAID Controller LED and I2C Connector
I2C connection
Page 21
Chapter 2: About Your HostRAID Controller l21
Mounting bracket
3.3V/5V PCI-X connector
0123
Activity LED
J2 LED connector
J7 (Aggregate Activity LED Header)
J1 connector (I2C)
SATA Ports

About the Adaptec 1420SA Controller

The Adaptec 1420SA is a low-profile PCI-X to 4 port SATA II HostRAID controller with these features:
Form factor Low-profile
Bus compatibility PCI-X
Ports 4
Connector, internal 4
RAID levels 0, 1, 10
Simple volume Yes
Disk drives SATA I (1.5Gbps), SATA II (3.0Gbps)
Maximum number of disk drives 4
Hot spares Yes
Enclosure support Yes, SATA II Enclosure Management using
Native Command Queuing (NCQ) Yes
Audible alarm No
There is no separate I2C connector. See the HostRAID Controller LED and I2C Connector
Note:
Reference on page 87 for details.
I2C connection
Page 22
Chapter 2: About Your HostRAID Controller l22
Mounting bracket
PCIe X1 connector
0
1
SATA ports
J1 Activity LED Connector

About the Adaptec 1220SA Controller

The Adaptec 1220SA is a low-profile PCIe to 2 port SATA II HostRAID controller with these features:
Form factor Low-profile
Bus compatibility PCIe-X1
Ports 2
Connector, internal 2
RAID levels 0, 1
Simple Volume Yes
Disk drives SATA I (1.5Gbps), SATA II (3.0Gbps)
Maximum number of disk drives 2
Hot spares Yes
Enclosure support No
Native Command Queuing (NCQ) Yes
Audible alarm No
Note:
There is no separate I2C connector. See the HostRAID Controller LED and I2C Connector
Reference on page 87 for details.
Page 23
Chapter 2: About Your HostRAID Controller l23
Mounting bracket
PCIe X1 connector
External SATA connectors
J1 LED Connector

About the Adaptec 1225SA Controller

The Adaptec 1225SA is a low-profile PCIe to 2 external port SATA II HostRAID controller with these features:
Form factor Low-profile
Bus compatibility PCIe-X1
Ports 2 external SATA ports
Connector, internal 0
Connector, external 2 external SATA connectors
RAID levels 0, 1 and 10
Simple Volume Yes
Disk drives SATA II (3.0Gbps) NCQ-enabled drives or
Maximum number of disk drives 2
Hot spares Yes
Enclosure support Yes—for port multiplier enclosures.
Native Command Queuing (NCQ) Yes
Audible alarm No
Note:
Note: There is no separate I2C connector. See the HostRAID Controller LED and I2C Connector
Reference on page 87 for details.
You can also connect one SATA drive enclosure with a port multiplier. For details about supported port multipliers, refer to
HostRAID Controller Features on page 15.
eSATA drives.
Adaptec 1225SA controller does not support bootable devices.
Page 24

Kit Contents and System Requirements

In this chapter...
Kit Contents............................................................................................................................ 25
System Requirements .............................................................................................................25
This chapter lists the contents of your HostRAID controller kit and the system requirements that must be met for you to successfully install and use your HostRAID controller.
3
Page 25

Kit Contents

Adaptec SAS or SATA HostRAID controllers
These utilities are embedded in the controller’s BIOS :
Array Configuration Utility (ACU)—Used to create, configure, and manage arrays
SerialSelect or SATASelect—Used to modify your controller and disk drive settings
Disk Utilities—Used to format and verify disk drives
HostRAID installation CD (bootable), including controller drivers, and this Guide
Adaptec Storage Manager installation CD (not bootable), including Adaptec Storage
Manager and the Adaptec HRCONF (HostRAID Configuration) command line utility
Readme files
Cables (type and quantity vary depending on your HostRAID controller—not included in
all controller kits. See Chapter 5 for details.)
Low-profile bracket
SAS and SATA HostRAID Controllers Quickstart Guide
Chapter 3: Kit Contents and System Requirements l25

System Requirements

PC-compatible computer with Intel Pentium, or equivalent processor
A motherboard with these features:
Complies with the PCI Local Bus Specification, Revision 2.2 and higher
Supports multifunction devices where one of the devices is a PCI bridge
Large memory-mapped address ranges
Refer to the Readme file on the HostRAID Installation CD for additional motherboard
Note:
compatibility information.
One of these operating systems:
Microsoft® Windows® Server 2003, XP and Windows Vista
Red Hat Linux
SUSE Linux
Novell® NetWare®
For up-to-date operating system version support, visit www.adaptec.com.
Note:
At least 256 MB of RAMs
Available compatible PCI/PCI-X/PCIe slot (depending on your controller model—see
Chapter 2.)
40 MB of free drive space
16-bit SVGA color monitor with a resolution of at least 800 x 600
CD drive
Appropriate interface cables
Page 26

Installing the HostRAID Controller and Disk Drives

In this chapter...
Before You Begin .................................................................................................................... 27
Installing the HostRAID Controller...................................................................................... 27
Selecting Disk Drives.............................................................................................................. 28
Selecting SAS Cables .............................................................................................................. 28
Selecting SATA Cables............................................................................................................ 30
Connecting Disk Drives to SAS HostRAID Controllers ...................................................... 30
Connecting Disk Drives to SATA HostRAID Controllers.................................................... 32
Setting the Boot Controller.................................................................................................... 33
Next Steps ............................................................................................................................... 34
This chapter explains how to install your HostRAID controller, and how to connect disk drives.
4
Page 27

Before You Begin

!
!
Read the Safety Information on page 92.
Familiarize yourself with your HostRAID controller’s physical features and the RAID levels
that it supports (see page 14).
Ensure that you have the right number of disk drives to achieve the desired RAID level (see
page 64).
Ensure that you have the proper cables for your controller and disk drives (see page 28 for
SAS page 30 cables and for SATA cables).
If you have a low-profile computer cabinet, replace the original full-height bracket with the
low-profile bracket supplied in the controller kit.
Chapter 4: Installing the HostRAID Controller and Disk Drives l27
Caution:
Handle the controller by its bracket or edges only.

Installing the HostRAID Controller

This section describes how to install your HostRAID controller into your computer cabinet.
1 Turn off your computer and disconnect the power cord. Open the cabinet, following the
manufacturer’s instructions.
2 Select an available PCI, PCIe or PCI-X expansion slot and
remove the slot cover, as shown at right.
For the best performance, use the available slot that’s compatible with your HostRAID controller (see Chapter 2).
PCI/PCIe bus compatibility is marked to the controller figures in About Your HostRAID Controller on page 14.
Caution:
the HostRAID controller.
3
As shown at right, insert the HostRAID controller into the expansion slot and press down gently but firmly until it clicks into place. When installed properly, the HostRAID controller should appear level with the expansion slot.
Touch a grounded metal object before handling
4 Secure the bracket in the expansion slot, using the retention
device (for instance, a screw or lever) supplied with your computer.
5 Connect your computer’s disk activity LED cable to the
LED connector on the HostRAID controller, if applicable to your controller. The LED connectors are marked on the figures in About Your HostRAID Controller on page 14.
Ensure that the positive lead of the LED cable (usually a red wire or a wire marked with a red stripe) is connected to pin
1.
Page 28
6 Optional—Connect your HostRAID controller’s I2C connector (not available on all
Internal SAS (SFF-8484) to SAS (SFF-
8484) cable
External miniSAS (SFF-8088) to SAS (SFF-8470) cable
External SFF-8470 to SFF-8470 cable
models) to an I2C connector on an internal backplane or enclosure, using an I2C cable.
7 Connect your disk drives, following the instructions on page 30 for SAS controllers or page
32 for SATA controllers.

Selecting Disk Drives

When selecting disk drives for your RAID array, ensure that all the disk drives have the same performance level. You can use different-sized disk drives in the array, but the array will be limited to the capacity of the smallest and slowest disk drive. For more information, refer to the Adaptec Storage Manager User’s Guide or Adaptec Storage Manager online Help.
Adaptec SAS HostRAID controller supports both SAS and Serial ATA (SATA) I and II disk drives. For cable information, see next section.

Selecting SAS Cables

You need one SAS cable for each disk drive you are connecting to your SAS HostRAID controller. Depending on your requirements, you can use any of these cables:
Chapter 4: Installing the HostRAID Controller and Disk Drives l28
Page 29
Chapter 4: Installing the HostRAID Controller and Disk Drives l29
External SFF-8088 to SFF-8088 cable
Internal SFF-8484 to 4x SFF-8482 fanout cable
Note: This cable is included in the
Adaptec HostRAID 44300 and 48300 controller kit. It can be used to connect SAS or SATA disk drives
Internal SFF-8484 to 4x SATA fanout cable
Internal SFF-8484 to SFF-8484 cable
Internal SFF-8087 to SFF-8484 cable
Adaptec recommends using only Adaptec SAS cables. For more information or to purchase cables, visit the Adaptec Web site at ww w.adaptec.com.
Page 30

Selecting SATA Cables

External SATA (eSATA) cable
Internal 4x SATA to SFF-8484 fanout cable
Internal SATA to SATA cables
Note: These cables are included in the
SATA HostRAID controller kit. There are two cables included in the 1220SA kit and four cables in the 1420SA or 1430SA kit.
You need one straight connector to straight connector SATA cable for each disk drive you are connecting to your SATA HostRAID controller. SATA cables are included in the kit.
Chapter 4: Installing the HostRAID Controller and Disk Drives l30
All SATA straight connector to straight connector cables have the same connectors, as shown in the following figure, and the connectors are keyed so that you can’t insert them incorrectly.
Adaptec recommends using only Adaptec SATA cables. For more information or to purchase cables, visit www.adaptec.com.

Connecting Disk Drives to SAS HostRAID Controllers

You can connect SAS disk drives, SATA disk drives, or a combination of both to your SAS HostRAID controller. There are no jumpers or switches to set before installation.
If you plan to build a bootable array using internal disk drives, ensure you install at least the minimum number disk drives required to support the RAID level you want. See page 65 for more information.
Note:
Although you can connect both SAS and SATA disk drives to your SAS HostRAID controller, Adaptec recommends not to combine SAS and SATA disk drives within the same array or logical drive. See page 59 for more information.
Page 31
Chapter 4: Installing the HostRAID Controller and Disk Drives l31
SATA disk drives attached to controller with fan-out cable
External
SAS cable
External SAS connector
You have these connection options:
Connecting Directly to the HostRAID Controller (see below).
Connecting to a Backplane on page 31.

Connecting Directly to the HostRAID Controller

In a direct-attach connection, SAS or SATA disk drives are connected directly to a SAS HostRAID controller with SAS cables. The number of direct-attached disk drives is limited to four per internal SAS connector. For more information, see Direct-Attach Connections on page
61.
1 Install your internal SAS or SATA disk drives, following the instructions in your system’s
documentation.
2 Use internal SAS cables to connect the disk drives to the SAS HostRAID controller.
3 When you have installed all disk drives and connected the to SAS HostRAID controller,
close your computer cabinet, and reconnect the power cord.

Connecting to a Backplane

In a backplane connection, disk drives and SAS HostRAID controllers are connected to, and communicate with each other through a backplane.
The number of disk drives is limited to the number of slots available on the backplane. Some backplanes have embedded SAS expanders and can support up to 128 end devices. For more information about expander connections, see page 32.
1 Connect one or more internal SAS or SATA disk drives to the backplane. Refer to your
system’s documentation for more information.
2 Use an internal SAS cable to connect the SAS HostRAID controller to the backplane.
Page 32
Chapter 4: Installing the HostRAID Controller and Disk Drives l32
Disk drives on backplane
Controller connected to backplane with fan-out cable
3 When all internal disk drives have been installed and connected, close your computer
cabinet, reconnect the power cord.

Installing the SAS HostRAID Controller to a SAS Expander

You can use a SAS expander to connect multiple disk drives to your SAS HostRAID controller (or to multiple SAS HostRAID controllers). Commands can be sent down one link and data returned on another in a separate connection to increase fault tolerance. Using a SAS expander and dual-port SAS drives and SATA drives with 2-port adapters, you can design redundant systems for maximum fault-tolerance.
To install the HostRAID controller to a SAS expander:
1 Using the appropriate cable, connect the SAS HostRAID controller to the expander’s PHY
connector.
2 Connect a cable from the expander’s PHY connector to a disk drive.

Connecting Disk Drives to SATA HostRAID Controllers

1 Install your SATA disk drives, following the instructions in your system’s documentation.
There are no jumpers or switches to set on the SATA controller or disk drives.
2 Connect each disk drive to a SATA port on the controller using a recommended SATA
cable. For cable information, see page 30.
3 When all disk drives have been installed and connected, close your computer cabinet, and
reconnect the power cord.

Checking Your Controller and Devices

Now that you have installed your controller and connected your disk drives, you can use the ARC utility to check your controller and devices, as described below:
1 Turn on yo ur c om pu ter.
2 When the Adaptec banner appears, press Ctrl+A to enter the Adaptec RAID Configuration
(ARC) utility.
3 If your drives have already been used in another system (even if not part of an array), select
Disk Utilities and format the drive. Otherwise, skip to Step 4.
Page 33
Chapter 4: Installing the HostRAID Controller and Disk Drives l33
4 Select SATASelect (on SATA controller) and SerialSelect (on SAS controller) to verify the
hardware configuration of the controller and the drives.
Verify that all drives are shown. If anything appears to be missing, power down the computer and check the connections.

Setting the Boot Controller

Note: If your system contains only one bootable controller, or if you are using the 1225SA
controller that does not support bootable devices, proceed with Creating an Array on page 39.
Most of the Adaptec HostRAID controllers support bootable disk drives and arrays. The default setting of the HostRAID controller and system Setup allows you to install and boot from either a disk drive connected to the motherboard, or from a drive or array connected to the HostRAID controller. To enable the system to boot from either a disk drive or an array connected to the HostRAID controller:
Note:
Selecting the boot controller is done using the system BIOS Setup Utility. Launching the system BIOS Setup Utility varies depending on your computer model. Refer to your computer documentation for instructions on how to access the system BIOS.
1
Enter the system BIOS Setup.
2 Navigate to the disk drive boot sequence.
3 Move the boot controller to the top of the list.
Page 34

Next Steps

If you are installing the driver and an operating system onto a bootable array, continue with
Creating a Bootable Array on page 38.
If you are completing a standard installation onto an existing operating system, continue with
Installing the Driver on an Existing Operating System on page 46.
Chapter 4: Installing the HostRAID Controller and Disk Drives l34
Page 35

Getting Started

In this chapter...
Choosing a RAID Level.......................................................................................................... 36
Choosing Installation Options .............................................................................................. 36
Basic Installation Steps........................................................................................................... 36
This chapter provides the basic information you need to set up your disk drives and arrays the way you want them. It also describes the options you have for installing your HostRAID controller and disk drives, and creating arrays for data storage.
Before you begin, familiarize yourself with your HostRAID controller’s physical features and the RAID levels that it supports. See Chapter 2, About Your HostRAID Controller.
5
Page 36

Choosing a RAID Level

Your HostRAID controller supports these RAID levels.
RAID 0 (Non-redundant Array)—Stripes data across multiple disk drives. Improved performance but no redundancy.
RAID 1 Array—Created from two disk drives where one disk drive is a mirror of the other (the same data is stored on each disk drive). Redundancy but reduced capacity.
RAID 10 Array—Built from two or more equal-sized RAID 1 arrays, stripes and mirrors data across multiple disk drives. Redundancy and improved performance.
See page 64 for more information on RAID levels and use the table on page 65 to see how many disk drives you must connect to your HostRAID controller to support the RAID level you want.

Choosing Installation Options

When you install your HostRAID controller, you can choose to create a bootable array and then install both operating system and controller driver on that array. Alternatively, you can complete a standard installation, where you install the controller driver on an existing operating system.
Chapter 5: Getting Started l36
Note:
Adaptec 1225SA controller does not support bootable devices, hence install this controller only on an existing operating system.

Basic Installation Steps

This section describes the installation process. Follow the steps for the installation option you’ve chosen.

Installing with an Operating System

You can install your HostRAID controller and the operating system using these steps:
1 Install and connect your controller and disk drives (see page 26).
2 Set the boot controller (see page 38).
3 Make the array bootable (see page 41).
4 Install your operating system and the driver (see page 42).
5 Install Adaptec Storage Manager and begin to manage your data storage (see page 50).

Installing with an Operating System On a Bootable Disk Drive/Array

When you install your HostRAID controller, you can create a bootable disk drive or an array and then install both operating system and controller driver on that disk drive or array. Alternatively, you can perform the standard installation, and install the controller driver on an existing operating system
Page 37
Chapter 5: Getting Started l37
1 Install and connect your controller and internal disk drives (see page 26).
If your controller has an external connector, you can also connect external disk drives, if required.
2 Install the controller driver (see page 47).
3 Install Adaptec Storage Manager and begin to manage your data storage (see page 50).

Installing on an Existing Operating System

1 Install and connect your controller and internal disk drives (see page 26).
If your controller has an external connector, you can connect external disk drives as well (or instead).
2 Install the controller driver (see page 47).
3 Install Adaptec Storage Manager and begin to manage your data storage (see page 50).
Page 38

Creating a Bootable Array

In this chapter...
Creating an Array ................................................................................................................... 39
Creating an Array with the ACU ........................................................................................... 39
Creating an Array with Adaptec Storage Manager ............................................................... 39
Making Your Array Bootable ................................................................................................. 41
This chapter explains how to set your HostRAID controller to be the boot controller, and how to create a bootable array.
Note:
If you are completing a standard installation onto an existing operating system,proceed to
Installing the Driver on an Existing Operating System on page 46.
Note: Adaptec 1225SA controller does not support bootable devices.
6
Page 39

Creating an Array

You can create a RAID 0, 1, or 10 array using one of these tools:
Array Configuration Utility (ACU)—BIOS-based menus and keyboard navigation (see
Appendix C, Using the ARC Utility).
Adaptec Storage Manager—Graphical software application running from a bootable CD
that you can navigate using your mouse (see About Adaptec Storage Manager on page 51).
HRCONF—Command line utility, refer to the Command Line Interface User’s Guide for
Direct Attached Storage.
You can use either tool, but the ACU is quicker and easier.
Adaptec recommends that you not combine SAS and SATA disk drives within the same
Note:
array. Adaptec Storage Manager generates a warning if you try to create a logical drive using a combination of SAS and SATA disk drives.

Creating an Array with the ACU

The ACU is menu-based and instructions for completing tasks display on-screen. Menus can be navigated using the arrows, Enter, Esc, and other keys on your keyboard.
Chapter 6: Creating a Bootable Array l39
Before creating arrays, make sure the disks for the array are connected and installed. Disks with no usable space are shown in gray and cannot be used.
To create an array:
1 Turn on your computer and press Ctrl+A when prompted to access the Adaptec RAID
Configuration (ARC) utility.
2 From the ARC menu, select Array Configuration Utility (ACU).
3 From the ACU Main menu, select Create Array.
4 Select the disks for the new array. RAID 0 and 1 requires a minimum of two disk drives.
RAID 10 requires a minimum of four disk drives. Then press Insert.
To deselect any disk, highlight the disk, then press Delete.
See the table on for the maximum number of drives that your HostRAID controller can support.
5 Select Enter when all disks for the new array are selected. The Array Properties menu
displays. For more Information see Assigning Array Properties on page 70.
6 When you are finished, select Done.

Creating an Array with Adaptec Storage Manager

This section describes how to use the Adaptec Storage Manager configuration wizard to build a RAID 0, 1, or 10 array.
You will need the HostRAID Installation CD to complete this task.
Note:
To create a RAID 0, 1, or 10 array:
1 Insert the HostRAID Installation CD into your CD drive, then restart your computer.
2 When prompted, select the language you want, then press Enter.
Page 40
Chapter 6: Creating a Bootable Array l40
3 Review the license information, then press Enter.
The Main Menu opens.
4 Click Launch Configuration Utility.
Adaptec Storage Manager opens.
5 Click Create.
The Configuration wizard opens.
6 Select Express configuration..., then click Next.
7 Review the information that is displayed.
Adaptec Storage Manager uses the term logical drives when referring to arrays.
Note:
In this example, Adaptec Storage Manager has used two equal-sized disk drives to automatically create one logical drive with RAID 1.
To specify a size for the logical drives, or to make other changes to the configuration, click Modify logical devices.
8 Click Apply, then click Ye s when prompted to confirm applying your new configuration.
Adaptec Storage Manager builds the logical drive(s).
The configuration is saved on the Adaptec controller (as an “array” ) and on the physical disk drives.
9 Partition and format your logical drive.
The logical drive you created appears as a physical disk drive on your operating system. You must partition and format these logical drives before you can use them to store data.
10 Close all windows, then click Reboot to restart your system.
11 Remove the HostRAID Installation CD.
For information on installing and using Adaptec Storage Manager as a full software application, refer to the Adaptec Storage Manager User’s Guide provided on the Adaptec Storage Manager CD.
12 Continue with Making Your Array Bootable (next section).

Making Your Array Bootable

Use the ACU to make the array bootable (see
Continue with Installing the Driver and an Operating System on page 42.
Managing Bootable Arrays and Devices on page 73).
Page 41

Installing the Driver and an Operating System

In this chapter...
This chapter explains how to install your HostRAID controller driver and an operating system onto a bootable array (see page 38).
Note:
7
Before You Begin .................................................................................................................... 43
Creating a Driver Disk ........................................................................................................... 43
Installing with Windows........................................................................................................ 43
Installing with Red Hat Linux ............................................................................................... 44
Installing with SUSE Linux.................................................................................................... 44
Installing with NetWare .........................................................................................................45
To install the driver on an existing operating system, see page 46.
Page 42

Before You Begin

Install and connect your HostRAID controller and internal disk drives, (see page 26).
Create a bootable array (see page 38).
Creating a driver disk (next section).
For up-to-date operating system version support, visit www.adaptec.com.
Note:

Creating a Driver Disk

Before you install your driver, you must create a driver disk. You need a floppy disk to complete this task. To create a driver disk:
1 Set your system BIOS so that your computer boots from the CD drive. (For instructions,
refer to your computer’s documentation).
2 Boot your computer from the bootable HostRAID Installation CD.
3 Click Create Driver Disk, from the Main Menu.
4 Select one of the operating systems from the list:
Chapter 7: Installing the Driver and an Operating System l43
Windows
Linux
Netware
5 Select the type of operating system you want to use.
6 Select the version of the operating system.
7 When prompted, insert a floppy disk, then click OK.
The system creates the driver disk.
8 Remove and label the driver disk.
9 Continue with the instructions for your operating system:
Installing with Windows on page 43
Installing with Red Hat Linux on page 44
Installing with SUSE Linux on page 44
Installing with NetWare on page 45

Installing with Windows

You will need your Windows Installation CD to complete this task. To install the HostRAID controller driver while installing Windows:
1 Insert your Windows CD, then restart the computer.
2 Follow the on-screen instructions to begin the Windows installation.
3 When prompted to install a third-party driver, press F6.
When F6 is active, a prompt appears at the bottom of the screen for only 5 seconds. If
Note:
you miss your chance to press F6, restart your computer.
Page 43
Chapter 7: Installing the Driver and an Operating System l44
4 Insert the driver disk, then wait until you are prompted to install a driver.
5 Press S to specify that the driver is on a floppy disk, then press Enter.
The computer reads the disk.
6 When the Adaptec SAS or SATA driver is found, press Enter.
7 Follow the on-screen instructions to complete the installation.
8 Continue with Managing Your Storage Space on page 50.

Installing with Red Hat Linux

You will need your Red Hat Installation CD to complete this task. To install the HostRAID controller driver while installing Red Hat Linux:
1 Insert the first Red Hat Installation CD.
2 Restart your computer.
3 When the Red Hat Welcome screen displays, type
4 When prompted, insert the driver disk, then select OK.
5 Follow the prompts to set up the environment you want.
6 If you are installing other third-party devices, install them now. Otherwise, select Done.
7 Complete the Red Hat Linux installation, following the instructions included with your
operating system.
8 Continue with Managing Your Storage Space on page 50.

Installing with SUSE Linux

To install the HostRAID controller driver while installing SuSE Linux:
1 Insert the first SUSE Installation CD.
2 Restart your computer.
3 When the SUSE (SLES 9 and 10) installation selection screen displays, press the F6 key,
select installation option from the Menu, then press Enter.
4 When prompted, insert the driver disk, then press any key to continue.
5 Follow the prompts to set up the environment you want.
linux dd
at the Boot: prompt.
6 If you are installing other third-party devices, install them now. Otherwise, select Back.
7 Complete the SUSE Linux installation, following the instructions included with your
operating system.
8 Continue with Managing Your Storage Space on page 50.
Page 44

Installing with NetWare

Note: NetWare does not support drive enclosures with port multipliers but supports eSATA drives.
You will need your NetWare Installation CD to complete this task. To install the driver when installing NetWare:
1 Restart your computer, then install NetWare. (For instructions, refer to your NetWare
documentation.)
To be able to load additional drivers later, select Manual install mode during the first part of the installation.
2 Click Continue to load additional drivers:
a Select Modify when the storage adapters are displayed.
b Select Storage Adapters, then press the Insert key twice to add an unlisted driver from
the floppy disk.
3 When the Device Types screen displays, check the Storage adapters list, then select Modify
to add another driver.
4 Select Storage Adapters, then press Enter.
Chapter 7: Installing the Driver and an Operating System l45
All recognized controllers are displayed.
5 If necessary, remove the default HostRAID driver (<driver-name>.ham).
6 Press the Delete key to remove it.
7 Press Insert to add another driver.
The available drivers are displayed.
8 Insert the driver floppy disk.
9 Press the Insert key to scan the floppy disk drive.
Once the driver is selected, the Parameter screen is displayed.
10 From the lower window menu, select Continue, then press Enter.
If the driver installation process fails, the server console is displayed so you can see the cause of the failure.
To modify disk partitions, apply hot fixes, or perform volume maintenance, refer to your NetWare documentation.
11 Continue with Managing Your Storage Space on page 50.
Page 45

Installing the Driver on an Existing Operating System

In this chapter...
Before You Begin .................................................................................................................... 47
Creating a Driver Disk or an Array ....................................................................................... 47
Installing on Windows XP or Windows 2003....................................................................... 47
Installing on Windows Vista.................................................................................................. 48
Installing on Red Hat or SUSE Linux.................................................................................... 48
Installing on NetWare ............................................................................................................ 48
This chapter explains how to install your HostRAID controller driver on an existing operating system.
Note:
To install the driver and an operating system on the bootable array, see page 42.
8
Page 46
Chapter 8: Installing the Driver on an Existing Operating System l47

Before You Begin

Before you begin, install and connect your HostRAID controller and internal disk drives (see
page 26).
You must also create a driver disk (see next section) before you begin installing the controller driver.
For up-to-date operating system version support, visit the Adaptec Web Site at
Note:
www.adaptec.com.

Creating a Driver Disk or an Array

Before you install your driver, you will need to create a driver disk. You will need a floppy disk to complete this task. To create a driver disk:
1 Set your system BIOS so that your computer boots from the CD drive. (For instructions,
refer to your computer’s documentation.)
2 Turn on your computer, then insert the HostRAID Installation CD included in your
controller kit.
3 Follow the on-screen instructions to get to the Adaptec Start Menu.
4 Click Create Driver Disk, from the Main Menu.
5 Select one of the operating systems from this list:
Windows XP/2003 and Windows Vista
Linux
Netware
6 Select the type of operating system you want to use.
7 Select the version of the operating system.
8 When prompted, insert the floppy disk, then click OK.
The system creates the driver disk.
9 Remove and label the driver disk.
10 Continue the driver installation for your operating system:
Installing on Windows XP or Windows 2003 (next section)
Installing on Windows Vista on page 48
Installing on Red Hat or SUSE Linux on page 48
Installing on NetWare on page 48

Installing on Windows XP or Windows 2003

To install the driver on Windows:
1 Start or restart Windows.
The Found New Hardware Wizard opens and searches for the driver.
2 Insert the driver disk, select Floppy drive, then click Next.
Page 47
Chapter 8: Installing the Driver on an Existing Operating System l48
3 Click Next, then click Next again.
4 Follow the on-screen instructions to complete the driver installation.
5 Remove the driver disk and restart your computer.
6 Continue with Managing Your Storage Space on page 50.

Installing on Windows Vista

1 Insert the Windows setup CD.
2 When prompted to install a third-party driver, click Load Driver.
3 Select the driver and click Next.
4 The disk array is displayed.
5 Click Drive Options to modify the RAID 10 size, else click Next to proceed with the
installation.

Installing on Red Hat or SUSE Linux

To install the module on Red Hat or SUSE Linux:
1 Insert and mount the RAID Installation CD:
Red Hat—mount /dev/cdrom /mnt/cdrom SuSE—mount /dev/cdrom /media/cdrom
2 Install the module RPM:
rpm -Uvh mount-point/xxx/yyy.rpm
where
mount-point
yyy.rpm
and
3 Run fdisk, mkfs, and create mount points for any new disk drives.
4 Continue with Managing Your Storage Space on page 50.
is the rpm file.

Installing on NetWare

Note: Before you begin, ensure that the NetWare operating system has been upgraded to the
minimum patch level specified by Novell. Refer to the Novell Web site for more information.
Note: NetWare does not support drive enclosures with port multipliers but supports eSATA drives.
To install the driver on NetWare:
1 Start your computer.
is the specific mount point on the Linux system,
xxx
is the driver path,
2 From the NetWare server console prompt, type
3 From the Device types menu, select Continue
4 From the Device type option, select Modify
5 Select Storage Adapters
6 From the Additional Driver Options menu, select Modify
,
then press Enter.
load hdetect
,
then press Enter.
,
then press Enter.
,
then press Enter.
,
then press Enter.
Page 48
Chapter 8: Installing the Driver on an Existing Operating System l49
7 From the Driver Name menu, press the Insert key.
8 Insert the driver disk, press the Insert key, then press F3.
9 From the A:\
prompt, press Enter.
The driver installs.
10 From the Additional Driver Option menu, select Return to driver summary
Enter.
11 From the Driver type menu, select Load on Additional Driver Options.
12 After the driver loads, select Continue.
13 Continue with Managing Your Storage Space on page 50.
,
then press
Page 49

Managing Your Storage Space

In this chapter...
About Adaptec Storage Manager........................................................................................... 51
About the HRCONF Command Line Utility........................................................................ 51
About the ARC Utility............................................................................................................ 52
About the Adaptec Flash Utility ............................................................................................ 52
Which Utility Should I Use? .................................................................................................. 52
Once you have installed your HostRAID controller, disk drives (or other devices), and device driver, you can begin to build and manage your storage space.
This chapter introduces the tools you can use to manage your storage space. All the tools described in this chapter are included on the CDs included with your HostRAID controller.
9
Page 50

About Adaptec Storage Manager

Adaptec Storage Manager is a full-featured software application that helps you build a storage space for your data. With Adaptec Storage Manager, you can group disk drives into logical drives and build in redundancy to protect your data and improve system performance.
Adaptec Storage Manager is included on the Adaptec Storage Manager Installation CD. For installation instructions, refer to the Adaptec Storage Manager User’s Guide, also included on the Adaptec Storage Manager Installation CD.
You can also use Adaptec Storage Manager to monitor and manage all the controllers and disk drives in your storage space from a single location.
When Adaptec Storage Manager is installed on a computer, the Adaptec Storage Manager agent is also installed automatically. The agent is like a service that keeps your storage space running. It runs in the background, without user intervention, and monitors and manages system health, notifies events, schedules tasks, and manages other on-going processes. It sends notices when tasks are completed successfully, and sounds an alarm when errors or failures occur.
The agent uses less memory than the full application. If your storage space includes systems that won’t be connected to monitors (and therefore won’t require the user interface), you can choose to run the agent only on those systems instead of the full application. For more information, refer to the Adaptec Storage Manager User’s Guide or online Help.
Chapter 9: Managing Your Storage Space l51

Installing Adaptec Storage Manager

Adaptec Storage Manager is included on the Adaptec Storage Manager Installation CD. For installation instructions, refer to the Adaptec Storage Manager User’s Guide for Direct Access Storage , also included on the Adaptec Storage Manager Installation CD.

About the HRCONF Command Line Utility

HRCONF (HostRAID Configuration Utility) is a command line utility that you can use to perform some basic array and configuration management functions.
With HRCONF, you can:
Create and delete logical drives
Modify and copy configuration settings
Recover from disk drive failures and troubleshoot
Adaptec recommends that only advanced users familiar with command line interfaces use
Note:
HRCONF.
Page 51

About the ARC Utility

!
The Adaptec RAID Configuration (ARC) utility is a BIOS-based utility that you can use to create and manage controllers, disk drives and other devices, and arrays. The ARC utility comprises these tools:
Array Configuration Utility (ACU)—For creating and managing arrays, and initializing
and rescanning disk drives.
SerialSelect Utility—Used to change device and HostRAID controller settings.
Disk Utilities—For formatting or verifying disk drives.
The ARC utility is included in your controller’s BIOS. For more information, see Using the
ARC Utility on page 68.
The ARC utility is primarily intended for pre-operating system installation configuration.

About the Adaptec Flash Utility

The Adaptec Flash Utility (AFU) is a text-based DOS utility that you can use to update, save, or verify your HostRAID controller’s firmware BIOS and Non-Volatile Random Access Memory (NVRAM). For more information, see page 80.
Chapter 9: Managing Your Storage Space l52
Caution:
your RAID controller’s flash contents, it is still important to use the AFU carefully and correctly to avoid rendering your RAID controller inoperable.Adaptec recommends that only advanced users familiar with working in DOS use the AFU.
Although the AFU contains safeguards to prevent you from accidentally damaging

Which Utility Should I Use?

To create a bootable array, Adaptec recommends that you use the BIOS-based ARC utility.
For all subsequent storage management tasks, Adaptec recommends that you install and use Adaptec Storage Manager (see page 51). As a full-featured software application with a graphical user interface (GUI), it is the easiest to use and offers the widest range of management functions.
Page 52

Solving Problems

In this chapter...
Troubleshooting Checklist ..................................................................................................... 54
Recovering from a Disk Drive Failure................................................................................... 54
Resetting the Controller......................................................................................................... 55
This chapter provides basic troubleshooting information and solutions for solving your HostRAID controller problems.
10
Page 53

Troubleshooting Checklist

If you encounter difficulties installing or using your HostRAID controller, check these items first:
With your computer powered off, check the connections to each disk drive, the power
supply, the LED connector, and so on.
Try disconnecting and reconnecting disk drives from the HostRAID controller.
Check that your HostRAID controller is installed in a compatible expansion slot. To
double-check the bus compatibility of your controller, see About Your HostRAID Controller
on page 14.
Ensure that your HostRAID controller is firmly seated and secured in the PCI, PCI-X, or
PCIe expansion slot.
If your HostRAID controller is not detected during system boot, try installing it in a
different expansion slot. See Installing the HostRAID Controller on page 27 for instructions.
Did the driver install correctly?
If you are still unable to resolve a problem, you can find additional troubleshooting information and direction on the Adaptec Web site at www.adaptec.com and the Adaptec Support Knowledgebase at ask.ad aptec.com.
Chapter 10: Solving Problems l54

Recovering from a Disk Drive Failure

This section explains how to recover when a disk drive fails:
If the array was protected by a hot spare, see next section.
If the array was not protected by a hot spare, see Failed Disk Drive Not Protected by a Hot
Spare on page 54.
If there is a disk drive failure in more than one array simultaneously, see Failure in Multiple
Arrays Simultaneously on page 55.
If it is a RAID 0 array, see Disk Drive Failure in a RAID 0 Array on page 55.
If multiple disk drives fail within the same array, see Multiple Failures in the Same Array on
page 55.
Adaptec Storage Manager uses the term logical drives when referring to arrays.
Note:

Failed Disk Drive Protected by a Hot Spare

When an array is protected by a hot spare, if a disk drive in that array fails the hot spare is automatically incorporated into the array and takes over for the failed drive.
To recover from the failure, remove and replace the failed disk drive (following manufacturer’s instructions).

Failed Disk Drive Not Protected by a Hot Spare

If a disk drive fails in an array that is not protected by a hot spare, replace the failed drive. The controller detects the new disk drive and rebuilds the array.
Page 54
Chapter 10: Solving Problems l55
If the controller fails to rebuild the array, check that the cables, disk drives, and controllers are properly installed and connected. Then, if necessary, use Adaptec Storage Manager to rebuild the array. For instructions, refer to the Adaptec Storage Manager User’s Guide or online Help.

Failure in Multiple Arrays Simultaneously

If the disk drive failure in more than one array at the same time (one failure per array), and the arrays are protected by hot spares, the controller rebuilds the arrays with these limitations:
A hot spare must be of equal or greater size than the failed disk drive it’s replacing.
Failed disk drives are replaced with hot spares in the order in which they failed. (The array
that includes the disk drive that failed first is rebuilt first, assuming an appropriate hot spare is available-see bullet above).
If there are more disk drive failures than hot spares, see Failed Disk Drive Not Protected by a Hot
Spare in previous section.

Disk Drive Failure in a RAID 0 Array

Because RAID 0 volumes do not include redundancy, if a disk drive fails in a RAID 0 array, the data can’t be recovered.
Correct the cause of the failure or replace the failed disk drives. Then, restore your data (if available).

Multiple Failures in the Same Array

If more than one disk drive fails at the same time in the same RAID 1 array, the data can’t be recovered.
Correct the cause of the failure or replace the failed disk drives. Then, restore your data (if available).
In some instances, RAID 10 arrays may survive multiple disk drive failures, depending on which disk drives fail. For more information, refer to the Adaptec Storage Manager User’s Guide or online Help.

Resetting the Controller

This section explains how to reset (or flash) your Adaptec HostRAID controller. You may want to do this if the controller becomes inoperable, or if a firmware upgrade is unsuccessful.
To reset your Adaptec HostRAID controller:
1 Download the firmware version currently installed on your controller from
www.adaptec.com.
2 Extract the downloaded files to a folder on your local hard drive (for example,
C:\Download\Drivers).
3
Create a bootable MS–DOS floppy disk and copy firmware image to the same floppy disk.
4 Create additional bootable MS–DOS floppy disks and copy each additional firmware
image to its own floppy disk.
the AFU.exe file to it. Copy the first
Page 55
Chapter 10: Solving Problems l56
5 Power off your computer, disconnect the power cord, then open the cabinet following the
manufacturer’s instructions.
6 Disconnect all cables from the controller, then attach a shorting jumper to the Mode 0
flash connector.
7 Reconnect the power cord, power on your computer, then boot to the floppy disk
containing the AFU.exe file (see Step 3).
8 At the prompt, type
9 Insert the other floppy disks when prompted.
10 When the flash is complete, power off your computer, disconnect the power cord, then
a:\afu update /c x,
where x is the controller number.
remove the jumper.
11 Close the computer cabinet, reconnect the power cord, then power on your computer.
The controller should boot correctly.
Page 56

Understanding RAID

In this chapter...
RAID Technology Overview .................................................................................................. 65
RAID 0 (Non-RAID Arrays).................................................................................................. 65
RAID 1 Arrays ........................................................................................................................ 66
RAID 10 Arrays ...................................................................................................................... 66
When you create arrays (or logical drives), you can assign a RAID level to protect your data.
Each RAID level offers a unique combination of performance and redundancy. RAID levels also vary by the number of disk drives they support.
This appendix describes the RAID levels supported by your HostRAID controller, and provides a basic overview of each to help you select the best level of protection for your data storage.
B
Page 57

RAID Technology Overview

RAID is the technology of grouping several physical drives into an array that you can define as one or more logical drives. Each logical drive appears to the operating system as a single drive. This grouping technique greatly enhances logical-drive capacity and performance beyond the physical limitations of a single physical drive.
When you group multiple physical drives into a logical drive, the HostRAID controller can transfer data in parallel from the multiple drives in the array. This parallel transfer yields data­transfer rates that are many times higher than with non-arrayed drives, allowing the system to better meet the throughput (amount of data processed in a given amount of time) or productivity needs of a multi-user network environment.
The ability to respond to multiple data requests provides not only an increase in throughput, but also a decrease in response time. The combination of parallel transfers and simultaneous responses to multiple requests allows disk arrays to provide a high level of performance in network environments.

Understanding Drive Segments

A drive segment is a disk drive or portion of a disk drive that is used to create an array. A disk drive can include both RAID segments (segments that are part of an array) and available segments. Each segment can be part of only one logical device at a time. If a disk drive is not part of any logical device, the entire disk is an available segment.
Appendix B: Understanding RAID 65

Stripe-Unit Size

With RAID technology, data is striped across an array of physical drives. This data-distribution scheme complements the way the operating system requests data.
The granularity at which data is stored on one drive of the array before subsequent data is stored on the next drive of the array is called the stripe-unit size.
You can set the stripe-unit size to 16, 32, or 64 KB. You can maximize the performance of your HostRAID controller by setting the stripe-unit size to a value that is close to the size of the system I/O requests. For example, performance in transaction-based environments, which typically involve large blocks of data, might be optimal when the stripe-unit size is set to 32 or 64 KB. However, performance in file and print environments, which typically involve multiple small blocks of data, might be optimal when the stripe-unit size is set to 16 KB.
The collection of stripe units, from the first drive of the array to the last drive of the array, is called a stripe.

RAID 0 (Non-RAID Arrays)

An array with RAID 0 includes two or more disk drives (maximum twelve) and provides data striping, where data is distributed evenly across the disk drives in equal-sized sections.
RAID 0 arrays do not maintain redundant data, so they offer no data protection. However, compared to an equal-sized group of independent disks, a RAID 0 array provides improved I/O performance.
Page 58
Appendix B: Understanding RAID 66
Drive segment size is limited to the size of the smallest disk drive in the array. For instance, an array with two 250 GB disk drives and two 400 GB disk drives can create a RAID 0 drive segment of 250 GB, for a total of 1000 GB for the volume, as shown in the following figure.
Disk Drive 1
Disk Drive 2
Disk Drive 3
Disk Drive 4
Disk Drives in Logical Drive

RAID 1 Arrays

A RAID 1 array is built from two disk drives, where one disk drive is a mirror of the other (the same data is stored on each disk drive). Compared to independent disk drives, RAID 1 arrays provide improved performance, with twice the read rate and an equal write rate of single disks. However, capacity is only 50 percent of independent disk drives.
250 GB
250 GB
400 GB
400 GB
Drive Segment Size (Smallest Disk Drive)
Disk Drive 1
Disk Drive 2
Disk Drive 3
Disk Drive 4
RAID 0 Logical Drive = 1000 GB
1
2
3
Not Used
4
Not Used
997
5
...
998
6
...
999
7
...
1000
8
...
Unused Space: 150 GB
Unused Space: 150 GB
If the RAID 1 array is built from different-sized disk drives, the free space, drive segment size is the size of the smaller disk drive, as shown in the following figure.
Disk Drive 1
Disk Drive 2
Disk Drives in Logical Drive

RAID 10 Arrays

A RAID 10 array is built from two or more equal-sized RAID 1 arrays. Adaptec RAID controllers support a maximum number of 48 disk drives in a RAID 10 array.
Data in a RAID 10 array is both striped and mirrored. Mirroring provides data protection, and striping improves performance.
250 GB
400 GB
Drive Segment Size (Smaller Disk Drive)
Disk Drive 1
Disk Drive 2
1 – 250
1 – 250
Not Used
Unused Space: 150 GB
RAID 1 Logical Drive = 250 GB
Page 59
Appendix B: Understanding RAID 67
Drive segment size is limited to the size of the smallest disk drive in the array. For instance, an array with two 250 GB disk drives and two 400 GB disk drives can create two mirrored drive segments of 250 GB, for a total of 500 GB for the array, as shown in the following figure.
Disk Drive 1
Disk Drive 2
Disk Drive 3
Disk Drive 4
250 GB
250 GB
400 GB
400 GB
Disk Drives in Logical Drive
Drive Segment Size (Smallest Disk Drive)
Disk Drive 1
Disk Drive 2
Disk Drive 3
Disk Drive 4
RAID 10 Logical Drive = 500 GB

Selecting the Best RAID Level

Use this table to select the RAID levels that are most appropriate for the logical drives on your storage space, based on the number of available disk drives and your requirements for performance and reliability.
1
3
2
4
1
3
Not Used
2
4
Not Used
499
...
500
...
499
...
Unused Space: 150 GB
500
...
Unused Space: 150 GB
RAID Level Redundancy
Disk Drive Usage
Read Performance
Write Performance
Built-in Hot Spare
Disk Drives
RAID 0 No 100% www www No 2
RAID 1Yes50%wwwwNo2
Minimum
RAID
Yes 50% ww ww No 4
10
Disk drive usage, read performance, and write performance depend on the number of drives in the logical drive. In general, the more drives, the better the performance.
Page 60

Introduction to SAS

In this chapter...
Terminology Used in This Appendix .................................................................................... 58
What is SAS? ........................................................................................................................... 58
How Do SAS Devices Communicate?................................................................................... 59
What’s a Phy? .......................................................................................................................... 59
What’s a SAS Port?.................................................................................................................. 59
What’s a SAS Address?............................................................................................................ 60
What’s a SAS Connector? ....................................................................................................... 60
What do SAS Cables Look Like?............................................................................................ 60
How are Disk Drives Identified in SAS?................................................................................ 60
What are the SAS Connection Options? ............................................................................... 61
How is SAS Different from Parallel SCSI?............................................................................. 62
This section provides a basic overview of the main features of SAS, introduces some common SAS terms, and explains how SAS differs from parallel SCSI.
A
Note:
For technical articles and tutorials about SAS, refer to the SCSI Trade Association (STATM) Web site at
www.scsita.org
.
Page 61

Terminology Used in This Appendix

For convenience, SAS HostRAID controllers are referred to generically in this appendix as SAS controllers, HBAs, disk drives, and external disk drive enclosures are referred to as end devices and expanders are referred to as expander devices.
For convenience, this chapter refers to end devices and expander devices collectively as SAS devices.

What is SAS?

Legacy parallel SCSI is an interface that lets devices such as computers and disk drives communicate with each other. Parallel SCSI moves multiple bits of data in parallel, using the SCSI command set.
SAS is an evolution of parallel SCSI to a point-to-point serial interface. SAS also uses the SCSI command set, but moves multiple bits of data one at a time. SAS links end devices through direct-attach connections, or through expander devices.
SAS controllers can typically support up to 128 end devices and can communicate with both SAS and SATA devices. You can add 128 end devices or even more with the use of SAS expanders. For more information, see SAS Expander Connections on page 61.
Appendix A: Introduction to SAS 58
Although you can use both SAS and SATA disk drives in the same SAS domain, Adaptec recommends that you not combine SAS and SATA disk drives within the same array or logical drive. The difference in performance between the two types of disk drives may adversely affect the performance of the array.
Data can move in both directions simultaneously across a SAS connection (called a link—see next section). Link speed is 600 MB/sec in full-duplex mode. A SAS controller with eight links has a maximum bandwidth of 4800 MB/sec in full-duplex mode.
Although they share the SCSI command set, SAS is conceptually different from parallel SCSI physically, and has its own types of connectors, cables, connection options, and terminology, as described in the rest of this chapter.
To compare SAS to parallel SCSI, see page 62.
Page 62

How Do SAS Devices Communicate?

SAS devices communicate with each other through links. A link is a physical connection between two phys.
As shown in the following figure, SAS devices contain ports which contain phys (see next section), and each phy contains one transmitter and one receiver (one transceiver). A phy can belong to one port only.
Appendix A: Introduction to SAS 59
Narrow Por t
Wide Por t
Wide Por t
Phy
SAS Device
Phy
Phy
Phy
Phy
Phy
Phy

What’s a Phy?

Phys are part of the physical communication connection between SAS devices. Each phy contains a transceiver that sends data back and forth between SAS devices.
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
link
SAS DeviceSAS Device
Transmitter Receiver
Transmitter Receiver
Transmitter Receiver
SAS Device
Transmitter Receiver
Transmitter Receiver
Transmitter Receiver
Transmitter Receiver
Phy
Phy
Phy
Phy
Phy
Phy
Phy
Narrow
Por t
Wide
Por t
Wide
Por t
When a connection is formed between two end devices, a link is established from a phy in one port to a phy in the other port. As shown in the figure above, a wide port can support multiple independent links simultaneously.
Phys are internal, within SAS connectors (see page 60).
SAS cables physically connect one or more phys on one SAS device to one or more phys on another SAS device.

What’s a SAS Port?

Note: Because the physical link between SAS devices is from phy to phy, rather than port to port, a
port is more of a virtual concept, different from what is normally considered a port on other types of RAID controllers and storage devices.
A port is one or more phys. A narrow port contains one phy. A wide port typically contains four phys.
Each port has its own unique SAS address (see page 60), and all the phys in a port share that same SAS address.
Page 63
SAS controller port options vary. A SAS controller with four phys could be configured with one wide port, with two wide ports that comprise two phys, or with four narrow ports each containing one phy. (A wide port with four phys is referred to as a 4-wide or 4x port.)

What’s a SAS Address?

Each SAS port is identified with a unique SAS address, which is shared by all phys on that port.
For example, a SAS disk drive might have two narrow ports. Each port has one unique SAS address. The single phy in each port uses its port’s SAS address.
In another example, a SAS device might have one 4-wide port. That port has one SAS address, which is shared by all four phys in the port.
Unlike SCSI devices and SCSI IDs, SAS devices self-configure their SAS addresses. User intervention is not required to set SAS addresses, and SAS addresses cannot be modified.

What’s a SAS Connector?

A SAS or mini-SAS connector is the physical plug or receptacle that you see on a SAS device. It supports the power and signal line cable. It’s what you plug a SAS cable into, or the end of the SAS cable that’s being plugged in.
Appendix A: Introduction to SAS 60
A connector is what forms physical links between phys. Some SAS connectors can support multiple links. The number of links a SAS connector can support is referred to as its width. Narrow connectors support a single link; wide connectors support up to four links.
A single SAS device may have one or more connectors. You can use a single SAS connector to inter-link more than two SAS devices. For example, in the figure on page 59, the 4-wide internal SAS connector forms links with four independent disk drives.
Mini-SAS connectors support both internal and external SAS connections. The mini-SAS connectors are smaller than the standard SAS internal and external connectors. Mini-SAS connectors support single and multilinks with the ability to scale to future speed needs.

What do SAS Cables Look Like?

Internal SAS cables are narrower than internal parallel SCSI cables. The connectors vary in size depending on the number of links they support, from single link connectors to 4-wide (or larger) connectors. Internal fan-out cables let you connect four disk drives to a single 4-wide connector.
For an example of some internal SAS or mini-SAS cables and an external SAS cable, see
Selecting SAS Cables on page 28.

How are Disk Drives Identified in SAS?

In the BIOS and in the management utilities, disk drives are identified with numbers in this format:
XX:YY:ZZ
where XX is the disk drive count number, YY is the enclosure number, and ZZ is the slot number (within the enclosure). If the disk drive is not installed in an enclosure, a double dashes (--) appear instead of YY and ZZ (for instance, 01:--:--).
Page 64
In parallel SCSI, XX is the disk drive’s channel number, YY is the target number, and ZZ is the logical unit number (LUN).

What are the SAS Connection Options?

You can connect end devices to each other through direct cable connections and through backplane connections. When you use one or more expander devices (see page 61), you can create large configurations.

Direct-Attach Connections

In a direct-attach connection, SAS or SATA disk drives are connected directly to a SAS controller with SAS cables. One disk drive is connected to one SAS connector with one SAS cable or multiple disk drives are connected to one SAS connector with one fan-out cable. The figure on page 31 shows an example of direct-attach connections.
The number of direct-connected disk drives is limited to the number of phys supported by the SAS controller.
There may be multiple phys within a single connector. See page 60.
Note:
Appendix A: Introduction to SAS 61

Backplane Connections

In a backplane connection, disk drives and SAS controllers are connected to and communicate with each other through a system backplane. The figure on page 31 shows an example of backplane connections.
There are two types of backplane connections, passive and active. When connecting to either backplane, it’s important to properly connect your disk drive LEDs in order to identify disk drive conditions. See About Your HostRAID Controller on page 14 for your RAID controller Activity LED connections and locations.
When connecting to a backplane, the Adaptec Storage Manager enables you to manage your system disk drives, see Next Steps on page 34.
The number of end devices is limited to the number of slots available on the backplane. For example, the Adaptec S50 enclosure, which contains an expander, is a backplane connection that supports up to 12 SAS or SATA disk drives.
Some backplanes support daisy-chain expansion to other backplanes. For example, you can daisy-chain up to nine Adaptec S50 enclosures to a single SAS controller in a host system.

SAS Expander Connections

A SAS expander device literally expands the number of end devices that you can connect together. Expander devices, typically embedded into a system backplane (see page 31), support large configurations of SAS end devices, including SAS controllers and SAS and SATA disk drives. With expander devices, you can build large and complex storage topologies.
There are two types of SAS expanders: fanout expanders and edge expanders. Each performs a different role in a storage system. (For more information about how SAS expanders work, refer to the STA Web site at www.scsita.org.)
You can connect up to 128 SAS ports to an edge expander. (A single edge expander can therefore support up to 128 SAS addresses.)
Page 65
Appendix A: Introduction to SAS 62
SAS Card
SAS Card
Disk Drives
Disk Drives
Disk Drives
Disk Drives
Disk Drives
Disk Drives
Fanout Expander
Disk Drives
Edge
Expander
Edge
Expander
SATA
SATA
SATA
SATA
SAS
SAS
SAS
SATA
Edge
Expander
SATA
SATA
SAS
SAS
Edge
Expander
Edge
Expander
SAS Card
SAS DomainSAS Domain
SATA SAS
You can connect up to 128 edge expanders to a fanout expander.
You can use only one fanout expander in any single SAS domain (a topology of SAS—and possibly SATA—end devices and expander devices). A single SAS domain can therefore comprise up to 16,384 SAS ports (and therefore up to 16,384 SAS addresses).
The following figure illustrates (in very basic terms) a SAS domain and shows how SAS controllers, SAS and SATA disk drives, and expander devices can fit together in a large data storage topology.

How is SAS Different from Parallel SCSI?

In summary, although SAS and parallel SCSI use the SCSI command set, how they move data from one place to another is very different. To support point-to-point serial data transport, SAS introduces new types of connectors, cables, connection options, and terminology.
Generally speaking, SAS is faster and more flexible than parallel SCSI, and provides more options for building your storage space. SAS lets you mix SAS and SATA disk drives together, and lets you connect many, many more devices.
The following table describes many of the main differences between the two interfaces.
Parallel SCSI Serial Attached SCSI
Parallel interface Serial interface
Maximum speed 320 MB/sec shared by all devices on the bus
Supports SCSI devices only Supports SATA and SAS disk drives
Up to 16 devices per SCSI channel
Supports single-port devices only Supports single- and dual-port devices
Uses SCSI IDs to differentiate between devices connected to the same adapter
Maximum speed 600 MB/sec per phy when in full-duplex mode
simultaneously
More than 128 disk drives per SAS controller, using an expander (see page
61)
Uses unique SAS addresses to differentiate between devices
Page 66
Appendix A: Introduction to SAS 63
Parallel SCSI Serial Attached SCSI
User intervention required to set SCSI IDs
Requires bus termination Requires no bus termination
Standard SCSI connectors SAS connectors (see page 28)
SAS addresses self-configured by SAS devices
Page 67

Using the ARC Utility

In this chapter...
Introduction to the ARC Utility ............................................................................................ 69
Running the ARC Utility........................................................................................................ 69
Creating and Managing Arrays.............................................................................................. 69
Using SerialSelect ................................................................................................................... 73
Using SATASelect.................................................................................................................... 75
Formatting and Verifying Disk Drives .................................................................................. 76
The Adaptec RAID Configuration (ARC) utility is an embedded BIOS-based utility that you can use to create, configure, and manage arrays, and format or verify disk drives.
Note:
Adaptec recommends that only advanced users familiar with working in a computer BIOS use the ARC utility
tools.
C
Page 68

Introduction to the ARC Utility

The ARC utility comprises these tools:
The Array Configuration Utility (ACU)—Used to create, configure, and manage arrays,
and initialize and rescan disk drives.
SerialSelect Utility (for SAS HostRAID controllers) or SATASelect Utility (for SATA
HostRAID controllers)—Used to change device and HostRAID controller settings.
Disk Utilities—Used to format or verify disk drives (see page 76).

Running the ARC Utility

All the tools within the ARC utility are menu-based and instructions for completing tasks display on-screen. Menus can be navigated using the arrows, Enter, Esc, and other keys on your keyboard.
To run the Utility:
1 Start or restart your computer. When prompted, press Ctrl+A.
The ARC utility menu displays presenting these options:
Appendix C: Using the ARC Utility 69
Array Configuration Utility (ACU)
SerialSelect or SATASelect Utility (depending on whether you are using a SAS or a
SATA HostRAID controller)
Disk utilities
To select an option from this menu, or from any of the menus within the ARC utility setup, browse with the arrow keys, then press Enter. In some cases, selecting an options displays another menu. To return to the previous menu at any time, press Esc.

Creating and Managing Arrays

Before creating arrays, make sure the disks for the array are properly connected and installed in your system. Note that disks with no usable space are shown in gray and cannot be used.

Creating a New Array

To create an array:
1 Select Create Array from the main ACU menu.
For more information about RAID levels and using disk drives to create arrays, see
Note:
Understanding RAID on page 64.
2
Select the disks for the new array, then press Insert. To deselect any disk, highlight the disk, then press Delete.
3 Press Enter when all disks for the new array are selected. The Array Properties menu
displays.
Page 69
Appendix C: Using the ARC Utility 70
Assigning Array Properties
Once the array is created and its properties are assigned, you cannot change the array properties using the ACU. Instead, use Adaptec Storage Manager. See About Adaptec Storage
Manager on page 51, for details.
To assign properties to the new array:
1 In the Array Properties menu, select an array type, then press Enter.
Only the available array types, RAID 0, 1, and 10 are displayed. RAID 0 and 1 requires two to four drives. RAID 10 requires a minimum of four disk drives.
2 (Optional). Type a label of no more than 15 characters for the array, then press Enter.
3 For RAID 0, select the desired stripe size. Available stripe sizes are 16, 32, and 64 KB
(default).
It is recommended that you do not change the default.
Note:
The options under Create RAID Via allows you to select between the different creation
4
methods for RAID 0, 1, and 10. The following table gives examples of when each is appropriate.
RAID Level
RAID 0 Quick Init Creating a RAID 0 on new drives.
RAID 0 Migrate Creating a RAID 0 and you want to preserve data on an existing
RAID 1 Build Creating a RAID 1 and you want to preserve data on an existing
RAID 1, 10Clear Creating a RAID 1 or 10 on new drives, or when you want to ensure
RAID 1, 10Quick Init Fastest way to create a RAID 1 or 10. Appropriate when using a new
Before adding a new drive to an array, back up any data contained on the new drive.
Create
RAID Via
When Appropriate
drive. You will be asked to select the source drive. The contents of the source drive are preserved and any data on the new drive is lost.
simple volume. You will be asked to select the source drive. The contents of the source drive are preserved and any data on the new drive is lost.
that the new array contains no existing data.
drive.
Otherwise, all data will be lost.
Only disk drives that were previously configured as simple volumes can be used for
RAID 0 or 1 migration when the single/source drive has data on it. See Configuring
Disk Drives on page 73 to create a simple volume.
If you stop the build or clear process on a RAID 1 from ACU, you can restart it by
pressing Ctrl+R.
A RAID 1 and 10 created using the Quick Init option may return some data
miscompares if you later run a consistency check. This is normal and is not a cause for concern.
If you stop the migration process on a RAID 0, you can restart it by pressing Ctrl+R.
To modify the Write Cache setting for an array, press Ctrl+W.
Page 70
Appendix C: Using the ARC Utility 71
The ACU allows you to use drives of different sizes in a RAID 1 or RAID 0. However,
during a build operation, only the smaller drive can be selected as the source drive.
When migrating from single volume to RAID 0, migrating from a larger drive to a
smaller drive is allowed. However, the destination drive must be at least half the capacity of the source drive.
It is not recommend that you migrate or build an array on Windows dynamic disks
(volumes), as it will result in data loss.
5 When you are finished, press Done.

Managing Arrays

Select the Manage Arrays option to perform these tasks:
Rebuilding Arrays (next section)
Viewing Array Properties on page 71
Deleting Arrays on page 72
Enabling/Disabling Write Cache on page 72
Rebuilding Arrays
Rebuilding applies to Fault Tolerant arrays (RAID 1) only.
Note:
By replacing a failed drive of a RAID 1 array with a new drive, you can rebuild to get the array to Optimal status and assume fault tolerance. You can perform a rebuild in the following ways:
If no spare exists and a hard disk drive fails, you need to create a spare before you can
Note:
rebuild an array. See Adding/Deleting Hot Spares on page 72 before continuing your rebuild.
System Shutdown Rebuild
You can power off the computer and replace the failed drive with a new one (of equal or greater capacity). When the system is booted, you can assign the new drive as a spare, and this will start the Rebuild task. All the data from the good drive is copied to the new one, and the original RAID 1 array is recreated.
Manual Rebuild
a From the Main Menu, select Manage Arrays. From the List of Arrays, select the array
you want to rebuild.
b Press Ctrl+R to rebuild.
Viewing Array Properties
To view the properties of an existing array:
1 From the ACU menu, select Manage Arrays.
2 From the List of Arrays dialog box, select the array you want to view, then press Enter.
The Array Properties dialog box appears, showing detailed information on the array. The physical disks associated with the array are displayed here.
3 Press Esc to return to the previous menu.
Page 71
Deleting Arrays
!
Appendix C: Using the ARC Utility 72
Caution:
lost. Deleted arrays cannot be restored.
Back up the data on an array before you delete it. Otherwise, all data on the array is
To delete an existing array:
1 From the ACU menu, select Manage Arrays.
2 Select the array you wish to delete, then press Delete.
3 In the Array Properties dialog box, select Delete, then press Enter.
For RAID 1 and 10 arrays:
Warning:
(Yes/No):
Deleting the array will render array unusable. Do you want to delete the array?
For RAID 0 arrays:
Warning:
No):
4
If you press Ye s , select the member:
Deleting the array will result in data loss! Do you want to delete the array? (Yes/
To delete the partition table, choose the member:
member #0, member #1, both, none
5 Press Esc to return to the previous menu.
Enabling/Disabling Write Cache
To Enable/Disable Write Cache for an array:
1 From the Main menu, select Manage Arrays.
2 From the List of Arrays, select the array you want to modify the Write Cache setting for,
then press Ctrl+W. A confirmation dialog appears to modify setting. Press Y to change the current Write Cache setting.
Write Cache is disabled by default when creating all array types. The disk operation may
Note:
be very slow with Write Cache off.

Adding/Deleting Hot Spares

Select the Add/Delete Hot Spares option to add, delete, or view hot spares.
1 From the ACU menu, select Add/Delete Hot Spares.
2 Use the up and down arrow keys to highlight the disk you want to designate as a hot spare,
then select Insert>Enter.
3 Press Ye s when the following prompt is displayed:
Do you want to create spare? (Yes/No)
The Spare you have selected appears in the Selected Drive menu.
Page 72
Appendix C: Using the ARC Utility 73
!

Managing Bootable Arrays and Devices

Select the Manager Boot Unit option to add or remove a bootable array or single drive.
1 From the ACU menu, select Manage Boot Unit.
2 Use the up and down arrow keys to highlight the array or single drive you want to
designate as a bootable device, then select Insert>Enter.
Adaptec 1225SA controller does not support bootable devices.
Note:

Configuring Disk Drives

Caution:
If the drive is used in an array, you may not be able to use the array again. Do not
configure a drive that is part of a boot array. To determine which drives are associated with a particular array, see Viewing Array Properties on page 71.
The partition table on the disk will be deleted when deleting a simple volume.
To configure drives:
Note:
Configuring disk drives makes a simple volume. A simple volume can be managed like normal arrays by using the Manage Arrays option on your Main menu.
1
From the menu, select Configure Drives.
2 Use the up and down arrow keys to highlight the disk you wish to configure, then press
Insert.
3 Repeat the previous step, if you want to add another drive to be configured.
4 Press Enter.
5 Read the warning message and ensure that you have selected the correct disk drives to
configure. Type

ATAPI Support

The following devices are supported:
The 1225SA and 1220SA supports detection of SATA ATAPI TAPE Drive and CDROM.
The 1225SA and 1220SA supports booting from the ELTORITO bootable CD/DVD media.
If a bootable CD/DVD media is detected, that bootable media gets precedence in the booting order.

Using SerialSelect

The SerialSelect utility allows you to change the BIOS and SAS HostRAID controller and device settings without opening the computer cabinet.
Y
to continue.
For more information, see SerialSelect Options on page 74.
Page 73
Appendix C: Using the ARC Utility 74
To access SerialSelect:
1 Restart the computer, then press Ctrl+A when prompted to access the ARC utility.
2 If multiple HostRAID controllers are installed, select the HostRAID controller you want to
configure, then press Enter.
3 From the ARC menu, select SerialSelect Utility.
4 To select a menu option, browse with the arrow keys to the option, then press Enter. In
some cases, selecting an option displays another menu. You can return to the previous menu at any time by pressing Esc.
5 To restore the original SerialSelect default values, press F6 from within the SAS Driver and
Controller Configuration screens.
6 To e x it S e r ia l Select, press Esc until a message prompts you to exit (if you changed any
settings, you are prompted to save the changes before you exit).
7 At the prompt, select Ye s to exit, then press any key to restart the computer. Any changes
you made in SerialSelect take effect after the computer restarts.

SerialSelect Options

The following table lists the available and default settings for each SerialSelect option and the description of each option. The default settings are appropriate for most systems and appear in bold type in the table. Adaptec recommends that you do not change the settings.
SerialSelect Options Available Settings Description
Controller Configuration
Runtime BIOS Enabled
Disabled Disabled:Scan bus
Controls the state of the BIOS at POST time. When Enabled, the the controller to act as a bootable device.
Disabling the BIOS allows another suitable
HostRAID controller BIOS allows
HostRAID controller to act as the boot device.
BBS Support Device
Controller
RAID Support Enabled
Disabled
POST Banner Display Enabled
Disabled
CTRL-A Message Enabled
Disabled
When BBS support is set to Device base, the system’s BIOS will list each connected bootable device to the individual entry. When BBS support is set to Controller base, the system’s BIOS will only list
HostRAID controller in the system boot
the order. This is useful in a multi-HostRAID
controller configuration.
When there are active arrays in the system, will not allow you to Disable RAID support.
When Enabled, the Adaptec banner, version, and copyright is displayed. When Disabled, the Adaptec banner, version, and copyright is not displayed.
When set to Enabled, the SAS controller BIOS displays the ARC Utility message on your screen during system bootup. If this setting is disabled, you can still invoke the ARC utility by pressing Ctrl+A after the SAS HostRAID controller BIOS banner appears.
HostRAID controller as an
HostRAID
Press <Ctrl> <A>
for
Page 74
Appendix C: Using the ARC Utility 75
SerialSelect Options Available Settings Description
Physical Drives Display during Post
PHY Configuration
PHY Rate Auto, 1.5, 3.0
SAS Address 0-F Specifies the last digit of a 64-bit SAS address of
Controller Properties
PCI Slot: Bus: Device:Function
Interrupt (IRQ) Channel None Displays interrupt
I/O Port Address None Displays I/O port address
Device ID None Displays device ID
Controller Serial Number
Controller WWN None Displays the controller WWN
Enabled Disabled
None Displays the path of the storage devices in a Host
None Displays controller serial number
When Enabled, connected physical devices are displayed during system POST. Displaying the devices adds a few seconds to the overall POST time.
The data transfer rate between the controller and devices. The default setting is Automatic, which allows the SAS HostRAID controller to adjust the speed as needed.
HostRAID controller, device, and each port
the using a globally unique worldwide name (WWN) identifier.
RAID controller.
HostRAID

Using SATASelect

The SATASelect utility allows you to change the BIOS and SATA HostRAID controller and device settings without opening the computer cabinet.
To access SATASelect:
1 Restart the computer, then press Ctrl+A when prompted to access the ARC utility.
2 If multiple HostRAID controllers are installed, select the HostRAID controller you want to
configure, then press Enter.
3 From the ARC menu, select SATASelect Utility.
4 To select a menu option, browse with the arrow keys to the option, then press Enter. In
some cases, selecting an option displays another menu. You can return to the previous menu at any time by pressing Esc.
5 To restore the default SATASelect values, press F6 from within the SATA Driver and
Controller Configuration screen.
6 To e x it S ATA Select, press Esc until a message prompts you to exit (if you changed any
settings, you are prompted to save the changes before you exit).
7 At the prompt, select Ye s to exit, then press any key to restart the computer. Any changes
you made in SATASelect take effect after the computer restarts.
Page 75
Appendix C: Using the ARC Utility 76
!

SATASelect Options

The following table lists the available and default settings for each SATASelect option and the description of each option. The default settings are appropriate for most systems and appear in bold type in the table. Adaptec recommends that you do not change the settings.
SATASelect Options Available Settings Description
Controller Configuration
Runtime BIOS Enabled
Disabled Disabled:Scan bus
BBS Support Device
Controller
Physical Drives Display during Post
SATA Configuration
Write Cache Enabled
DMA (1420SA only) Enabled
Device Security Lock (1430SA & 1220SA Only)
SMART Enabled
Allow Read Ahead Enabled
Enabled Disabled
Disabled
Disabled
Enabled Disabled
Disabled
Disabled
Controls the state of the BIOS at POST time. When Enabled, the the controller to act as a bootable device. Disabling the BIOS allows another suitable
HostRAID controller BIOS allows
HostRAID controller to act as the boot device.
When BBS support is set to Device base, the system’s BIOS will list each connected bootable device to the individual entry. When BBS support is set to Controller base, the system’s BIOS will only list
HostRAID controller in the system boot
the order. This is useful in a multi-
controller configuration.
When Enabled, connected physical devices are displayed during system POST. Displaying the devices adds a few seconds to the overall POST time.
Enables or disables write cache on the on legacy and non-configured drives. Write cache enabled provides maximum performance. Default is Yes to enable.
Enables or disables the use of Direct Memory Access (DMA) mode for the drive. Enabled provides maximum performance. Default is Yes to enable.
Enables or disables the device security lock option. When enabling this option, a Security Freeze Lock command is issued to the device.
Enables or disables the predictive failure feature of the disk drive. When enabled the SMART status of the drive (Healthy or Failed) will be displayed along with the physical drive display during POST. If the drive does not support SMART, the SMART status is not displayed. Default is Yes to enable.
Enables or disables the read ahead cache algorithm on the drive. Enabled provides maximum performance under most circumstances. Default is Yes to enable.
HostRAID controller as an
HostRAID

Formatting and Verifying Disk Drives

You can use the disk utilities to low-level format or verify your disk drives. (New disk drives are low-level formatted at the factory and do not need to be low-level formatted again.).
Caution:
disk drive.
Before you format a disk drive, back up all data. Formatting destroys all data on a
Page 76
Appendix C: Using the ARC Utility 77
!
To use the disk utilities:
1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility.
2 From the ARC utility menu, select Disk Utilities.
3 Select the desired disk, then press Enter.
Format Disk—Simulates a low-level format of the disk drive by writing zeros to the
entire disk. SATA drives are low-level formatted at the factory and do not need to be low-level formatted again.
Caution:
before performing this operation.
Ver ify Dis k M e di a —Scans the media of a disk drive for defects.
Formatting destroys all data on the disk. Be sure to back up your data

Locating Disk Drives

Note: This feature is only available with disk drives that have an activity LED.
You can use the Identify Drive feature to physically locate a disk drive by blinking the LED.
To locate a disk drive:
1 Start the ARC utility (see page 69).
2 Select the controller you want, then press Enter.
3 Select Disk Utilities.
4 Select the disk drive you want, then press Enter.
5 Select Identify Drive, then press Enter.
6 When you have finished locating your disk drive, press any key to stop the blinking.

Identifying Disk Drives

You can identify disk drives by viewing the list of disk drives on your system. Only physical drives that display during POST are shown.
To identify a disk drive:
1 Start the ARC utility (see page 69).
2 Select the controller you want, then press Enter.
3 Select Disk Utilities.
The Disk Utilities view will provide you with the following information:
Location Model Rev# Speed Size
CN1=DEV1 Box0=Slot0 Exp0=phy0
The manufacturer information.
The revision number of the disk drive.
The speed of the disk drive.
The size of the disk drive.
The location information of a disk drive is determined by three types of connections:
Page 77
Direct attached drives—The connection is determined by the cable connected to a device,
for example CN1 (connector 1) is connected to DEV1 (device 1). For more information, see
Direct-Attach Connections
Storage Enclosure Processor (SEP) managed devices—The connection is determined by an
active backplane. Box0 (enclosure 0) is connected to slot0 (disk drive slot 0 in the enclosure). For more information, see Backplane Connections
Expanders—The connections is determinded by an expander. Exp0 (expander 0) is
connected to phy0 (phy 0 within a connector). For more information, see SAS Expander
Connections
on page 61.
Note: Devices other than disk drives (CDROM, tape drives, etc...) are listed in order after your
system disk drives.

Viewing the Event Log

The BIOS-based event log records all firmware events, such as configuration changes, array creation, and boot activity.
Some events are not stored indefinitely—the event log is cleared of any non-persistent events each time you restart your computer; additionally, once the log is full, new events overwrite old events.
Appendix C: Using the ARC Utility 78
on page 61.
on page 61.
To view the event log:
1 Start the utility (see page 69).
2 Select the controller you want, then press Enter.
3 When the utility menu appears, then press Ctrl+P.
4 Select Controller Log Information, then press Enter.
Page 78
Using the Adaptec Flash Utility for
!
DOS
In this Appendix...
Introduction ........................................................................................................................... 80
System Requirements .............................................................................................................80
Compatibility Information.................................................................................................... 80
Before You Begin .................................................................................................................... 80
Running the AFU ................................................................................................................... 81
AFU Commands..................................................................................................................... 82
Updating Flash Using AFU Command Line......................................................................... 85
This Appendix describes how to use the Adaptec Flash Utility (AFU), a text-based DOS utility that you can use to update, save, or verify the HostRAID controller’s firmware BIOS.
D
Caution:
your HostRAID controller’s flash contents, it is still important to use the AFU carefully and correctly to avoid rendering your HostRAID controller inoperable. Adaptec recommends that only advanced users familiar with working in DOS use the AFU.
Although the AFU contains safeguards to prevent you from accidentally damaging
Page 79

Introduction

The AFU is a text-based DOS utility used to update, save, or verify your HostRAID controller’s firmware BIOS and Non-Volatile Random Access Memory (NVRAM).
The AFU is easy to use and contains safeguards to prevent you from accidentally damaging the HostRAID controller’s flash contents. Still, you must be careful to use the AFU correctly, otherwise, you could render the HostRAID controller inoperable.

System Requirements

The requirements for AFU are as follows:
MS–DOS version 5.0 or later. It cannot run from a DOS command prompt window under
any version of Windows.
You can’t run the AFU from a DOS command prompt window under any version of Windows.
Note:
At least 8 MB of extended memory.

Compatibility Information

Appendix D: Using the Adaptec Flash Utility for DOS 80
The AFU has the following compatibility issues:
Supports HIMEM.SYS and is compatible with other DOS drivers running under
HIMEM.SYS (for example, SMARTDRV.SYS and SETVER.SYS).
Does not support DOS extenders installed in memory, such as EMM386.SYS and
DOS4GW.

Before You Begin

Before running the AFU, complete these tasks:
Obtaining the Firmware on page 80
Creating the Firmware Kit On Floppy Disks on page 81

Obtaining the Firmware

To obtain HostRAID controller firmware, go to:
The HostRAID Installation CD—Includes the AFU executable (AFU.exe) and a separate flash image. The flash image may comprise multiple User Flash Image (UFI) files.
The Adaptec Web site (www.adaptec.com)—Download a new firmware file to get the most recent version of AFU.
Page 80

Creating the Firmware Kit On Floppy Disks

To create the firmware floppy disks:
1 Create a bootable MS–DOS floppy disk and copy these files to it:
AFU.exe
Axxxx01.ufi
where xxx is the model number of your controller.
Most controller model numbers have a suffix. Check that the .ufi file is the correct file for
Note:
your controller before copying.
2
Copy each additional Axxxx0x.ufi file to a separate floppy disk. (Some RAID controllers have one UFI file; some have two. Each goes onto its own floppy disk.

Running the AFU

You can run the AFU using:
Running the Menu-Based AFU(next section)
Appendix D: Using the Adaptec Flash Utility for DOS 81
Running the AFU from the Command Line on page 82

Running the Menu-Based AFU

The easy way to run the AFU is to use its GUI. If you prefer to run the AFU from the command line, see Running the AFU from the Command Line on page 82.
To access the AFU:
1 Shut down your operating system and reboot to DOS from a bootable MS-DOS floppy
disk or from a DOS partition on a bootable drive. You can use the drive connected to the HostRAID controller you are updating.
When updating the HostRAID controller flash, controller activity is not possible. Before
Note:
you can use the HostRAID controller again, complete the flash operation and restart the computer.
2
At the DOS command prompt (typically A:\>) type
The AFU’s main menu is displayed.
3 Select Select Controllers, then select the Adaptec HostRAID controllers to be flashed.
When selecting a single controller, the system automatically selects it. When selecting multiple controllers, use the spacebar, then press Enter.
AFU,
then press Enter.
Page 81
Appendix D: Using the Adaptec Flash Utility for DOS 82
4 Select Select an Operation and choose one of these options, then follow the on-screen
instructions.
Update—Updates all the flash components on a HostRAID controller with the flash
image data from a User Flash Image (UFI) file. The AFU updates the HostRAID controller’s flash by reading UFI files and writing them to the controller’s flash components.
The UFI includes the HostRAID controller’s type, thereby ensuring that the AFU uses
Note:
the correct file.
Save—Updates and verifies the BIOS image of the HostRAID controller.
Ve r i f y —Reads the contents of a HostRAID controller’s flash components and
compares it to the contents of the specified UFI file.
Ve r s i o n —Displays version information about a HostRAID controller’s flash
components.
List—Lists all supported HostRAID controllers detected in your system.

Running the AFU from the Command Line

At the DOS command prompt (typically A:\>), type switches. The AFU processes the command, prompts you to insert additional floppy disks as needed, exits, and reports success or an error message code. The available commands are summarized in in alphabetical order.

AFU Commands

You can manage your HostRAID controller’s BIOS firmware using these commands:
HELP (next section)
LIST on page 83
SAVE on page 83
UPDATE on page 84
VERIFY on page 84
VERSION on page 85

HELP

The
HELP
command displays a summary of AFU functions and command switches.
Examples
AFU
followed by a command and any
The following are examples of command syntax that will work to get help:
A:\> AFU HELP
A:\> AFU /?
Page 82
Appendix D: Using the Adaptec Flash Utility for DOS 83

LIST

The
LIST
command displays the AFU-supported HostRAID controllers installed on your computer. Use this command to see which HostRAID controllers are installed, or to identify the ID numbers assigned to each physical controller.
You do not have to restart the computer after completing this command.
Example
This example shows a typical system response to a
A:\> AFU LIST
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Controllers Detected and Recognized:
Controller #0 (03:01:00) Adaptec ASC-48300
LIST
command:

SAVE

The
SAVE
command saves the contents of a HostRAID controller’s flash in a UFI file. The name of the UFI file is based on the HostRAID controller type and cannot be changed.
Command Syntax
The command syntax for the
AFU SAVE [/C<Controller ID>] [/D <UFI File Path>]
Command Switches
The following switches are available:
/C <Controller ID> is one or more HostRAID controller IDs representing the set of
controllers on which to perform the specified command. The default is 0, which means that if the computer has multiple HostRAID controllers, the AFU defaults to controller 0 unless you specify otherwise.
SAVE
command is as follows:
/C 0
To specify a single HostRAID controller ID, for example:
To specify multiple IDs separated by commas, for example:
To represent all HostRAID controllers:
ALL
/C 0,2
Note: If you are using multiple HostRAID controllers, you must specify the controller you want
by using the /C switch; otherwise, the AFU displays an error message and exits. You cannot select ALL HostRAID controllers when specifying SAVE.
/D <UFI File Path> specifies the path (drive and directory) where the UFI files are located.
If you do not specify the /D switch, the AFU looks for, or creates, UFI files in the default location.
You cannot specify the name of a UFI file, only its path. UFI filenames are predefined,
Note:
based on the HostRAID controller type.
Examples
In the following example, the AFU saves flash contents from HostRAID controller 0 to a UFI file in the current default drive and directory:
Page 83
Appendix D: Using the Adaptec Flash Utility for DOS 84
A:\> AFU SAVE /C 0
In the following example, the AFU saves flash contents from Controller 1 to a UFI file in C:\UFI_FILES.
A:\> AFU SAVE /C 1 /D C:\UFI_FILES

UPDATE

The
UPDATE
command updates a HostRAID controller’s flash components from the flash image data in a UFI file. You can use the flash components or to update multiple HostRAID controllers on your computer.
UPDATE
command to update a single HostRAID controller’s
You must restart the computer following an
UPDATE
command.
Command Syntax
The command syntax for the
AFU UPDATE [/C<
Controller ID
UPDATE
>] [/D <
command is as follows:
UFI File Path
>]
Command Switches
For details on the /C and /D switches, see SAVE on page 83.
Examples
The following example shows a typical system response after an update has been performed:
A:\> AFU UPDATE /C 0
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Updating Controller 0 (Adaptec ASC-48300)
Reading flash image file (Build 1406)
AFU is about to update firmware on controller(s) Adaptec ASC-48300
***PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE***
This might take a few minutes.
Writing Adaptec ASC-48300 (4MB) Flash Image to controller 0...OK.
Verifying...OK
Please restart the computer to allow firmware changes to take effect.

VERIFY

The
VERIFY
controller to the corresponding image in a UFI file and indicates whether they match. Use this command to determine whether a HostRAID controller’s flash components are up-to-date when compared to a specific UFI file.
Command Syntax
The command syntax for the
AFU VERIFY [/C<
Command Switches
For details on the /C and /D switches, see SAVE on page 83.
command compares the contents of each of the flash components on a HostRAID
VERIFY
Controller ID
command is as follows:
>] [/D <
UFI File Path
>]
Page 84
Example
Appendix D: Using the Adaptec Flash Utility for DOS 85
The following example shows a typical system response after a performed:
A:\> AFU VERIFY /C 0
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Reading flash image file (Build 1406)
Controller #0: Adaptec ASC-48300
File: Checksum: 642C [VALID] (Build 1406)
File: Checksum: 642C [VALID] (Build 1406)
Verified Successfully

VERSION

The
VERSION
HostRAID controller.
Command Syntax
The command syntax for the
AFU VERSION [/C<
Command Switches
For details on the /C switch, see SAVE on page 83.
command displays version information about the flash components on a
VERSION
Controller ID
command is as follows:
>]
VERIFY
command has been
Example
The following example displays version information about all supported HostRAID controllers:
A:\> AFU VERSION /C 0
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Version Information for Controller #0 (Adaptec ASC-48300)
ROM: Build 1406 [VALID]

Updating Flash Using AFU Command Line

This section provides step-by step instructions for updating the flash.
1 Create the firmware kit on floppy disks (see page 81).
2 Power off your computer, insert the first AFU floppy disk, then power on your computer.
If your computer isn’t set up to boot from the bootable floppy disk, enter the system setup utility to change the setting.
3 At the DOS command, if you have multiple controllers and you don’t know the number of
the controller you want to update, type next step.
AFU LIST
, then press Enter. Otherwise, skip to the
4 At the DOS command, type AFU followed by a command (see page 82) and any switches
you want.
Page 85
Appendix D: Using the Adaptec Flash Utility for DOS 86
5 Update the flash using the instructions suitable for your requirements:
To update a single HostRAID controller:
AFU UPDATE /C <
cont_number
>
Where <cont_number> is the number of the RAID controller whose firmware you are updating. For example, to upgrade Controller 0, type
To update multiple HostRAID controllers:
AFU UPDATE /C <
cont_number_a
>,<
cont_number_b
AFU UPDATE /C 0
>
Where <controller_number_a> and <controller_number_b> are the numbers of the Adaptec RAID controllers whose firmware you are updating. For example, to upgrade controllers 0, 2, and 3, type
To update all HostRAID controllers simultaneously
AFU UPDATE /C all
AFU UPDATE /C 0, 2, 3.
:
Note: The UFI file identifies the RAID controllers, so you don’t have to worry about flashing
the wrong controller.
6
When prompted, insert the first firmware disk into your floppy disk drive.
The AFU reads the first disk.
7 When prompted, remove the first firmware disk and insert the second firmware disk into
your floppy disk drive.
8 Repeat Step 7 until the flash update is complete.
Page 86

HostRAID Controller LED and I2C Connector Reference

In this appendix...
Adaptec 58300 Activity LED Connector Specification......................................................... 88
Adaptec 48300 Activity LED Connector Specification......................................................... 88
Adaptec 44300 Activity LED Connector Specification......................................................... 89
Adaptec 1430SA Activity LED and I2C Connector Specification........................................ 89
Adaptec 1420SA Activity LED and I2C Connector Specification........................................ 90
Adaptec 1220SA Activity LED Connector Specification ...................................................... 91
Adaptec 1225SA Activity LED Specification......................................................................... 91
This chapter provides a activity LED and I2C connector reference for HostRAID controllers.
E
Page 87
Appendix E: HostRAID Controller LED and I2C Connector Reference 88

Adaptec 58300 Activity LED Connector Specification

2220600-R ASC-58300 RoHS Kit
J3—Aggregate Activity LED Header
Pin Number Signal Description
1 BUSYLED- Aggregate Cathode
2 +3.3V Aggregate Anode
Aggregate LED signals only.
Note:
There is no I2C function on this controller as all ports are external.

Adaptec 48300 Activity LED Connector Specification

2216400-R ASC-48300 with I2C HR RoHS Kit
2254000-R ASC-48300 I2C RoHS Single
J3—Aggregate Activity LED Header
Pin Number Signal Description
1 BUSYLED- Aggregate Cathode
2 +3.3V Aggregate Anode
Aggregate LED signals only.
Note:
There is no separate I2C connector. I2C signals are contained within the side band signals of the SFF-8484 connector.
J4—SFF-8484 Connector
Pin Number Signal Description
14 I2C_CLK SB0 - 2W_SCL
15 I2C_DAT SB1- 2W_SDA
16 GND SB2 - Ground
17 GND SB3 - Ground
18 RST_OUT SB4 - Reset
19 BKPL_ID SB5 - Backplane Address
Page 88
Appendix E: HostRAID Controller LED and I2C Connector Reference 89

Adaptec 44300 Activity LED Connector Specification

2220300-R ASC-44300 RoHS Kit
2253900-R ASC-44300 RoHS Single
J3—Aggregate Activity LED Header
Pin Number Signal Description
1 BUSYLED- Aggregate Cathode
2 +3.3V Aggregate Anode
Aggregate LED signals only.
Note:
There is no separate I2C connector. I2C signals are contained within the side band signals of the SFF-8484 connector.
J4—SFF-8484 Connector
Pin Number Signal Description
14 I2C_CLK SB0 - 2W_SCL
15 I2C_DAT SB1- 2W_SDA
16 GND SB2 - Ground
17 GND SB3 - Ground
18 RST_OUT SB4 - Reset
19 BKPL_ID SB5 - Backplane
Address

Adaptec 1430SA Activity LED and I2C Connector Specification

2240900-R AAR-1430SA RoHS Kit
2240900JA-R AAR-1430SA RoHS Kit
2241000-R AAR-1430SA RoHS Single
J1—LED Connector
Pin Number Signal Description
1 LED_OUT0- PORT 0 Cathode
2LED OUT 1-PORT 1 Cathode
3LED OUT 2-PORT 2 Cathode
4LED OUT 3-PORT 3 Cathode
Note:
Board circuitry supports common anode backplane implementations.
Page 89
Appendix E: HostRAID Controller LED and I2C Connector Reference 90
J2—I2C Connector
Pin Number Signal Description
1 TWSISDA I2C Data
2 GND Ground
3 TWSISCK I2C Clock
J3—Aggregate LED Header
Pin Number Signal Description
1
2
LED_SUM Aggregate Cathode
+3.3V Aggregate Anode
J4—Activity LED Connector
Pin Number Signal Description 22-55-2081
1 ACT_LED3- PORT 3 Cathode 2
2 +3.3V PORT 3 Anode 1
3 ACT_LED2- PORT 2 Cathode 4
4 +3.3V PORT 2 Anode 3
5 ACT_LED1- PORT 1 Cathode 6
6 +3.3V PORT 1 Anode 5
7 ACT_LED0- PORT 0 Cathode 8
8 +3.3V PORT 0 Anode 7

Adaptec 1420SA Activity LED and I2C Connector Specification

2170200EU-R AAR-1420SA/EFIGS RoHS KIT
2170200JA-R AAR-1420SA/JA RoHS KIT
2170200-R AAR-1420SA RoHS KIT
2170500-R AAR-1420SA RoHS Single
J2—LED Connector
Pin Number Signal Description
1 LED OUT0- PORT 0 Cathode
2LED OUT 1-PORT 1 Cathode
3LED OUT 2-PORT 2 Cathode
4LED OUT 3-PORT 3 Cathode
Note:
Board circuitry supports common anode backplane implementations.
Page 90
Appendix E: HostRAID Controller LED and I2C Connector Reference 91
J7—Aggregate Activity LED Header
Pin Number Signal Description
1
2
LED_SUM Aggregate Cathode
+3.3V Aggregate Anode
J1—I2C Connector
Pin Number Signal Description
1 TWSISDA I2C Data
2 GND Ground
3 TWSISCK I2C Clock

Adaptec 1220SA Activity LED Connector Specification

2232100-R AAR-1220SA RoHS Kit
2232100JA-R AAR-1220SA RoHS Kit
J1—Activity LED Connector
Pin Number Signal Description
1 ACT_LED1- PORT 1 Cathode
2 +3.3V PORT 1 Anode
3 ACT_LED0- PORT 0 Cathode
4 +3.3V PORT 0 Anode
Board circuitry supports common anode backplane implementations.
Note:

Adaptec 1225SA Activity LED Specification

2257700-R AAR-1225SA RoHS Kit
2257700JA-R AAR-1225SA RoHS Kit
2257800-R AAR-1225SA RoHS Single
J1—Activity LED Connector
Pin Number Signal Description
1 ACT_LED1- PORT 1 Cathode
2 +3.3V PORT 1 Anode
3 ACT_LED0- PORT 0 Cathode
4 +3.3V PORT 0 Anode
Note:
Board circuitry supports common anode backplane implementations.
Page 91

Safety Information

!
To ensure your personal safety and the safety of your equipment:
Keep your work area and the computer clean and clear of debris.
Before opening the system cabinet, unplug the power cord.

Electrostatic Discharge(ESD)

Caution: ESD can damage electronic components when they are improperly handled, and can
result in total or intermittent failures. Always follow ESD-prevention procedures when removing and replacing components.
To p re ve nt ES D d am ag e :
Use an ESD wrist or ankle strap and ensure that it makes skin contact. Connect the
equipment end of the strap to an unpainted metal surface on the chassis.
If a wrist strap is not available, ground yourself by touching the metal chassis before
handling the controller or any oth er part of the computer.
Avoid touching the controller against your clothing. The wrist strap protects components
from ESD on the body only.
Handle the controller by its bracket or edges only. Avoid touching the printed circuit board
or the connectors.
F
Put the controller down only on an antistatic surface such as the bag supplied in your kit.
If you are returning the controller to Adaptec, put it back in its antistatic bag immediately.
Page 92

Technical Specifications

In this chapter...
Environmental Specifications................................................................................................ 94
DC Power Requirements........................................................................................................ 94
Current Requirements............................................................................................................94
G
Page 93

Environmental Specifications

Appendix G: Technical Specifications 94
Ambient temperature without forced airflow
Ambient temperature with forced airflow of atleast 200 CFM
Relative humidity 10% to 90%, noncondensing
Altitude up to 3,000 meters
Note: Forced airflow is recommended, but not required.

DC Power Requirements

PCI, PCI-X, PCIe Ripple and noise 50mV peak-to-peak (max)
PCI, PCIX DC Voltage 5V ±5%, 3.3V ± 10%
PCIe DC Voltage 3.3V ± 10%

Current Requirements

Adaptec Model Maximum Current (A)
ASC-58300 0.56A
ASC-48300 1.322A
ASC-44300 .445A
AAR-1430SA 1.5A
AAR-1420SA 1.5A
AAR-1220SA 1.5A
AAR-1225SA 1.5A
0°C to 40° C
0°C to 55°
C
Page 94

Glossary

A
activity
See task.
ACU
Array Configuration Utility. An application used to create, configure, and manage arrays from the controller’s BIOS or MS-DOS.
array
A logical disk created from available space and made up of one or more segments on one or more physical disks. Arrays are typically used to provide data redundancy or enhanced I/O performance. See volume,
RAID 0, RAID 1, RAID 10. Also known as a container.
array initialization
See configure.
ATA
AT Bus Attachment. Standard parallel interface to IDE hard disks typically used in desktop computers and some entry-level servers. Serial ATA (SATA), is a successor to parallel ATA, which is sometimes referred to as PATA.
available space/segment
Unused space on a configured disk from which logical devices (arrays) are created. When an array is deleted, the space that it used is returned to the available space pool.
B
background consistency check
Option that forces the controller to constantly check all portions of disks used by all arrays to see if the disks can return data from the blocks. See consistency check command.
bad segment
Segment that is in an unknown state.
bootable array
Array configured as the boot device.
Page 95
Glossary 96
build
Background initialization of a redundant array. The array is accessible throughout. RAID 1 copies the contents of the primary drive to a secondary drive. See clear.
bus
See channel.
C
cache
Fast-access memory on the controller that serves as intermediate storage for data that is read from, or written to, drives.
capacity
Total usable space available in megabytes or gigabytes.
channel
Any path, or bus, used for the transfer of data and the control of information between storage devices and a RAID controller. For SATA channels, each channel has a single drive capacity.
check point
A feature that enables you to exit the ACU when an operation is in progress and be able to continue without interruption. The driver then resumes the operation from where the BIOS left off and the BIOS resumes the operation where the driver left off.
chunk
See stripe.
clear
Foreground initialization of a fault-tolerant array. A clear operation zeros all blocks of the array. The array is not accessible until the clear task is complete.
concatenation
Joining of physical or logical drives in sequential order.
configure
Process of preparing a disk for use by the controller. When a disk is configured, the controller records the RAID signature on the disk.
configured array
An array that is ready for data reads and writes. Arrays can be configured by build or clear.
consistency check command
Command that reads all the blocks of a RAID 1 to determine if the blocks are consistent. Any inconsistent blocks are fixed.
D
dead partition
See failed.
degraded
A redundant (for example, a RAID 1) array in which one or more members have failed. The data is intact but redundancy has been compromised. Any further failure would cause the array to fail and result in data loss.
disk
Physical disk drive. Randomly accessible, rewriteable data storage device. Also called hard disk.
Page 96
Glossary 97
disk ID
Unique disk identifier that consists of the channel number, SATA ID. For example, (channel:ID:LUN) 1:04:0. See channel.
drive LED
Disk indicator LED that illuminates during read or write operations.
E
event
Notification or alert from the system, indicating that a change has occurred.
event log
File used to maintain information about prior controller activities or errors.
event notification
Process for transmitting events.
F
failed
State of a nonredundant array that has suffered a single drive failure, or a redundant array that has suffered multiple drive failures. A failed array is inaccessible and data is lost.
fault-tolerant array
Refers to an array that can continue to function after a disk drive failure without loss of data. Fault tolerant, or redundant arrays, include RAID 1 arrays. See redundant.
foreign disk
Disk that has previously been configured on another Adaptec RAID controller. The RAID signature on the disk allows the RAID controller to identify whether or not the disk was configured on the controller it is currently connected to.
H
hard disk drive
Basic unit of nonvolatile, nonremovable, magnetic storage media. See disk.
hot spare
A spare hard disk that automatically replaces a failed hard disk on any array associated with any HBA.
hot swap
To remove a component from a system, and install a new component while the power is on and the system is running.
I
impacted
An impacted array is one which has been created but for some reason the initial build operation did not complete. All member drives are present and operational, and all data written to the array is protected. To optimize the array, run a Verify with Fix Task.
initialize
See configure.
Page 97
Glossary 98
L
legacy disk
Disk that contained a valid partition table when connected to the controller. The controller manages the disk as a legacy disk array where there is a one-to-one logical-to-physical mapping of array to disk.
logical device
Volume comprised of space from one or more physical drives and presented to the operating system as if it were a single storage unit.
low-level format
Process performed by the drive firmware that completely cleans any data off the hard disk.
M
mirrored array/mirroring
See RAID 1, RAID 10.
monitoring
Process of receiving, displaying, and logging system events.
N
Native Command Queuing
Allows disk drives to arrange commands into the most efficient order for optimum performance.
O
offline array
Array that can no longer be accessed.
optimal
The state of an array when it is fully operational. For redundant arrays, the entire array is protected.
P
partition
A section of a disk storage device created by the operating system disk management program, in which data and/or software programs are stored. Computers have a primary operating system partition that contains the special files needed to boot the computer. Each operating system partition is assigned a unique drive letter, such as C or D. A single disk device can have multiple partitions.
phantom object
Object that represents a component that cannot be configured by the controller management software; for example, a missing drive.
Q
quick init
An array configured using the Quick Init option is available immediately, with no on-going background controller activity. All data written to an array that has been quick configured is protected.
Page 98
Glossary 99
R
RAID
Redundant Array of Independent Disks (alternative definition Redundant Array of Inexpensive Disks).
RAID 0
A single-level array consisting of two or more equal-sized segments residing on different disks. RAID 0 distributes data evenly across its respective drives in equal-sized sections called stripes. RAID 0 arrays are not redundant.
RAID 1
Single-level array consisting of two equal segments residing on two different drives. Provides redundancy by storing identical copies on two drives. See mirrored array/mirroring.
RAID 10
Spanned array consisting of two or more equal-sized RAID 1 arrays. Provides redundancy by striping and mirroring. Mirroring provides data protection, and striping improves performance. See mirrored array/
mirroring, RAID 0.
RAID signature
The area on each disk reserved for use by the RAID controller.
RAID volume
Concatenates two or more arrays of the same type.
rebuild
Background regeneration of redundant data on a RAID 1.
redundant
The ability of an array to maintain operability when one or more hardware failures occur. RAID 1 is redundant. In the event of a drive failure, redundant arrays can be restored to normal operation by replacing the failed drive and rebuilding the array.
rescan
Process of updating the current screen to show all currently available resources.
S
Serial Attached SCSI (SAS)
An evolution of parallel SCSI to a point-to-point serial interface
Serial ATA (SATA )
A successor to ATA that uses a serial, instead of parallel, interface.
simple volume
A volume made up of disk space from a single disk. It can consist of a single region on a disk, or concatenated multiple regions of the same disk.
single-level array
Array created from one or more segments. See volume, RAID 0, RAID 1, RAID 10.
snapshot
Instantaneous read-only copy of an array at a precise point in time.
stripe
Contiguous set of data distributed across all the disks in an array. A striped array distributes data evenly across all members in equal-sized sections called stripes.
Page 99
Glossary 100
stripe size
The amount of data in each section of a striped array.
striped array
See RAID 0, RAID 10.
T
task
An operation that occurs only on the RAID controller, asynchronous to all other operations; for example, initializing a disk or verifying an array. Some tasks can take an extended period of time, particularly if the RAID controller is also performing intensive data I/O while the task is running.
V
verify
Low-level check that a drive, logical device, or hot spare is good. In a RAID 1, verify is a low-level check that contents of both members’ segments are consistent and, optionally, corrects errors while assuming that the master drive is correct. In a simple volume, verify performs a low-level check that the whole drive can be read.
volume
See simple volume.
Page 100

Index

A
ACU
creating arrays Adaptec customer support Adaptec Flash Utility.
69
See
3
AFU Adaptec RAID Configuration Utility. Adaptec Storage Manager
installing
AFU
80
Array Configuration Utility.
51
See
ACU
arrays
creating (ACU) non-RAID RAID 1
66
RAID 10
69
65
66
B
backplane connections
31, 61
C
connectors controllers
event log flashing resetting
customer support
77
78
55
55
3
See
HRCONF
failure recovery
multiple arrays multiple disk drives with hot spare
without hot spare recovering from failure SAS identifiers
60
drivers
installing on Linux installing on NetWare installing on Windows
E
electrostatic discharge end devices event log
58
78
expander connections expander devices
58
F
failed disk drives
multiple arrays
55
multiple disk drives without hot spare
flashing controllers
54
55
H
55
55
54
54
54
48
48
47
92
61
55
D
data striping direct-attach connections disk drives
connecting to SAS controllers connecting to SATA controllers connections
65
31, 61
77
30
32
hard disk, hard disk drive, hard drive.
I
installation
disk drives (SAS) disk drives (SATA) SAS backplane
30
32
31
See
disk drives