Adams Rite 8300-7030-US32D, 8300-7030-US4, 8300-7036-32DMEC, 8300-7036-US3, 8300-7036-US32D Specsheet

...
Page 1
EXIT DEVICES
BHMA TYPE 3
Mortise Exit Device
For Wood & Hollow Steel Doors
3300 Series
FIRE-RATED
8300 Series
LIFE-SAFETY
ED-3
8300 SERIES:
U
Life-Safety Listing
L
®
ANSI/BHMA A156.3 Grade 1 California State Fire Marshall New York City MEA*
*Consult factory for specific number
3300 SERIES:
U
10C 3-Hour Fire Label
L
®
California State Fire Marshall New Yo rk City MEA* Warnock/Hersey Listing for Fire Doors up to 10 Feet.
Features:
Heavy duty deadlatching mechanism
Pushbar clad or anodized, not plated, in a variety of finishes
Easy to install
Clean, unobtrusive design
Strong, durable construction for a high level of security
260 Santa Fe Street Pomona, California 91767 () ()
800 872-3267 Fax: 800 232-7329
www.adamsrite.com
Page 2
Features & Dimensions
Mortise Exit Device
ANSI/BHMA
Grade 1
Handing
Specify handing and bevel if applicable. Lever Entry Trim is field reversible.
Pushbar Length
Standard Sizes: Dimensioned for 30", 36", 42" & 48" openings. Standard width bars can be field cut to the next smallest opening width.
Door Thickness
Suits 1-3/4" standard. Can be modified for thicker doors.
Stile Width
/8300
3300 -
*Door construction may require additional stile width to meet fire ratings and provide adequate strength.
Minimum 5"*
Projection
2-5/8" when fully projected, 1-5/8" when dogged.
Materials
Pushbar made of extruded aluminum, clad or anodized in a variety of finishes.
Dogging
Standard dogging with hex key or cylinder dogging for 8300 Series only. Electric dogging also available for 3300 and 8300 Series.
Fasteners
Standard self-tapping screws. Optional Sex Bolt Kits-26-0584 (2 required per device) Specify finish.
Strikes
Made of stainless steel. Supplied with exit device. See strike options below.
Cylinders (order separately) Cylinder x
Fixed Pull:
(Function 03) Accepts any standard Mortise cylinder.
Entry Lever or Thumbturn: (Functions 08, 09, 11, 12)
Accepts any standard diameter Mortise cylinder with MS cam. Accommodates
®
cylinder lengths from 1" to 1-1/4".
Warranty
Five year limited.
AVAILABLE FINISHES
313
335
628
US3
US4
US9
US10
10B
Dark Bronze Anodized
Black Anodized
Clear Anodized
Bright Brass
Satin Brass
Bright Bronze
Satin Bronze
Dark Bronze (Trim only)
US32
Bright Stainless
US32D
Satin Stainless
Consult factory for special finishes.
Fire Rating:
MODEL
Single Point
3300
3300 Fire-Rated/8300 Life-Safety
Heavy-duty deadlatch fits ANSI A115.1 standard door and jamb prep. 2-3/4“ backset.
TYPE
Mortise
RATING
3 Hr.
* May be used with Model 3100 or 3600 with an open back strike.
DOOR
CONSTR.
Hollow Metal
or Wood
MAX. SIZE
SINGLE DOORS
4'0"x 10'0"
MAX. SIZE
PAIRS, DBL.
EGRESS
8'0" x 8'0"*
Pushbar Dimensions
2-5/8
2-7/16
Fully Projected Dogged
Strikes
A variety of strikes are available for different conditions and applications.
Standard Strike
8360-01
1-5/8
1"
“A”
Extended Lip
8360-xx
Specify Dim.A
Open Back
4009-01
Page 3
Trim & Function
Mortise Exit Device
ANSI/BHMA Functions:
01 02 03 08
PULL ONLY
WHEN DOGGED
DUMMY TRIM
EXIT
ONLY-
NO TRIM
N/A N/A N/A
KEY RETRACTS
LATCHBOLT
NL
KEY LOCKS
LEVER
CYLINDER TYPE
MORTISEMORTISE MORTISE MORTISE MORTISE
09 11 12 14
KEY LOCKS
KEY LOCKS
LEVER
KEY LOCKS
THUMBTURN
THUMBTURN
NL NL
8300 ONLY
KEY LOCKS
THUMBTURN
8300 ONLY
NL
PAS SA GE SET
-- Night Latch
1.9
3.25
8.10
Modern Model 3081
Fixed Pulls
()
US32 only
11.50
2.75
T ubular
Model 3001
2.31
5.00
Clutch Lever Entry Trim
3.45
8.10
T ubular Model 3082
Thumbturn
11.50
2.75
Model 3002
2.03
Flat
1.9
4.55
5.81
Model 8066
For 8300 only
T raditional Model 3083
Mortise Cylinder
Standard diameter five-pin unit with MS cam, suitable for use with Entry Trim on
1.631.63
Rim exit devices. All brass construction with front "scalp" available in finishes 628, 313 and 335. Available in quantity all keyed different (KD), in pairs (KA2) or fifty alike (KA50). Any other make standard
Mortise cylinder with MS cam can be used to "key in" with existing systems.
2.91
8.10
®
1.9
4.35
4036-01
®
--
Page 4
Options & Accessories
Mortise Exit Device
Order by adding suffix to Exit Device in place of hyphen or by separate model number.
MONITOR/SIGNAL SWITCH
M1 - Single Switch M2 - Dual Switch
A switch in the exit device pushbar mounted on the hinge end. Switch can be used to activate signal light, horn, monitor or other
For all Adams Rite Exit Devices
open or normally closed depending upon application. Can be retrofit in field to existing exit device. Dual switch version offers redundancy as required by some building codes or the option of operating a second signaling device.
Specify by adding "M1"or "M2" after exit device model number.
Monitor Kits for upgrading any 3000 or 8000 Series device: 91-0897-01 - Single Switch 91-0897-02 - Dual Switch
devices. Most common application is to release maglock when pushbar is depressed. Switch can be wired for normally
ELECTRIC LATCH RETRACTION
The LR option uses a
solenoid mounted in
pushbar for instantaneous
unlocking and locking of the exit
device from a remote location or access
control device. Because electrical operation of
device is fail-secure, this option can be used on fire-
rated as well as life-safety applications. In the event of a
of PS-LR Power Supply, which will power two exit devices. (Using an alternate to the PS-LR Power Supply will void warranty).
Specify by adding "LR" after exit device model number. Order PS-LR Power Supply separately. Order Battery Backup Kit separately (BBK-LR).
Solenoid Specifications:
16 Amps Inrush/.5 Amps Hold Solenoids are rated for both intermittent and continuous operation. Also see 4612 Power Transfer.
power failure device automatically relatches. Requires the use
MONITORED DUMMY PUSHBAR
8099M1 - Single Switch
8099M2 - Dual Switch
8099-00 - Dummy Only
Dummy pushbar with no latch mechanism but with either a single or dual monitor/signal switch. Most common application is in conjunction with a maglock where bar is used to turn off magnet and allow exit from building. Dual switch version allows redundancy where required by code or the operation of a with maglock. Specify door type and width when ordering. Available in all exit device finishes. The 8099-00 is also available as a non-operating dummy for doors not requiring an exit device, but where matching trim is desired. Specify door type, opening width and finish to be matched.
signal device along
ALARMED EXIT DEVICE
Adams Rite
Exit Devices
This option emits a loud alarm to notify management of unauthorized exit. Will not alter the Life-Safety characteristics of the exit device in any way. Control of the alarm is by use of a key in any standard Mortise cylinder with MS cam to arm, disarm, delay or reset the alarm. Red letters on the bar give a “hands off” warning to deter accidental actuation.
Battery Operated Alarm
Four AA alkaline batteries power a horn to create a piercing 95 decibel noise for two minutes (or until disarmed) when pushbar is depressed.
Hardwired Alarm
Can be connected to external horn for louder or remote signal. Remote monitor LED light can also be wired in, as can a door position proximity switch. Also accommodates an external delay switch, such as an outside key switch or pad, entry. Uses rechargeable nicad batteries connected to 12-24 Volt AC or DC source. Each bar has its own battery backup system.
Minimum opening width: 36"
Beeps to signal need for new batteries.
®
to allow authorized
CYLINDER DOGGING
For all non-fire rated Adams Rite Exit Devices
For management control of dogging. Any standard 15/16" to 1-1/8" long Mortise cylinder with MS cam can be used in a pushbar prepared at factory with Cylinder Dogging kit. Cannot be used with Alarm, EL or LR options.
Specify by adding "C" after exit device model number.
®
ELECTRIC DOGGING
For all Adams Rite Exit Devices
The "ED" option uses a holding magnet to keep the pushbar depressed (set manually) and the latch retracted. This gives a lower profile exit device, resulting in less damage and quieter operation. All "ED" devices include an internal microswitch that signals when the bar is held in the depressed position, ideal for automatic door operators. On fire-rated devices, it must be wired through the fire alarm system. All devices operate at 24VDC,drawing .6 amp, allowing them to operate with a simple transformer and rectifier.
Note: N
with access control devices such as card reader or keypads.
Specify by adding "ED" after exit device model number (ex. 8 611 ED 36) .
ot to be used as access control element. Specify "LR"
For all
©2008 ADAMS RITE MANUFACTURING CO.
Loading...