Adams Rite 4603 Installation Instructions

Page 1
9/4/2008
8
FOR ENGINEERING REFERENCE ONLY
SILICON
DIODES
( 4 R EQ'D )
AC
WIRE
D
C
RED
WIRE
POS
WHITE
WIRE
AC
NEG
BLACK WIRE
RED
7
6
QUALITY CONTROL TEST & CHECK INSTRUCTIONS:
45
3
REV DESCRIPTION ECN DATE REV. BY APVD
H CHANGE OVERALL DIM'S & WIRING 8792 02-17-94 -- MP
J CHANGE TO NEW 2 AMP RECTIFIER 9042 03-22-95 -- MP
2
1
A) SET SIMPSON METER ON +DC & RX1.
B) INSERT BLACK LEAD TO COMMON JACK AND READ LEAD TO + JACK.
ADDED SHRINK TUBING, DELETED:
K
NOTE 5, NOTE 7 WAS #18 AHG WIRE,
P/N 4603 WAS 29-0377
L
REDRAWN IN SWORKS; ADDED
NOTE #10
9995 01-27-00 -- MP
D
10730 RR
C) ATTACH RED WIRE FROM SIMPSON METER TO EITHER RED WIRE OF THE RECTIFIER.
D) ATTACH BLACK WIRE FROM SIMPSON METER TO WHITE RECTIFIER WIRE. THERE SHOULD BE CONTINUITY & METER SHOULD SHOW READING.
E) REMOVE BLACK WIRE FROM SIMPSON METER AT THE WHITE RECTIFIER WIRE & ATTACH TO THE BLACK WIRE FROM RECTIFIER. THERE MUST BE NO READING.
3/8 MAX
4 PLCS
.25 MAX
4 PLCS
C
WHITE
10. THE PART MUST BE PACKAGED IN A CLEAR PLASTIC BAG WITH INSTRUCTION SHEET P/N 80-0180-293. INSTRUCTION SHEET MUST BE FOLDED 3 TIMES.
9. PURCHASED FROM DIODES, INC. UNDER P/N BR82DLB
B
OR ENGINEERING APPROVED EQUIVALENT.
8. FULL WAVE BRIDGE RECTIFIER 2 AMP 200 PIV MIN.
7. #18 AWG WIRE, FOR -20°C TO 80°C TEMP. AND Ø.085 MAX O.D.
6. UNIT MUST BE CONSTRUCTED FROM UL LISTED COMPONENTS; LETTER OF CERTIFICATION MUST ACCOMPANY EACH SHIPMENT.
4. FINISH:
3. MATERIAL:
A
2. BREAK ALL SHARP EDGES.
1. ALL DIMENSIONS ARE FINISHED DIMENSIONS.
NOTES: UNLESS OTHERWISE SPECIFIED.
8
7
L
RED
RED
BLACK
8.0±.5
4 PLCS
AC
AC
-
.510 MAX
.710 MAX
B
.259 MAX
TOLERANCE UNLESS OTHERWISE SPECIFIED
UNIT ENGLISH METRIC
FRACTIONS
.X
.XX
.XXX
ANGLES
--
NEXT ASSY
6
5
4603
PRODUCT
APPLICATION
4
1/32
.1
.01
.005
1
.010 TIR
.005 TIR
----
----
.12
----
1
.25 TIR
.12 TIR
THIS DRAWING REMAINS THE PROPERTY OF ADAMS RITE MFG. CO. IT MUST BE KEPT CONFIDENTIAL AND EMPLOYED ONLY FOR THE PURPOSE FOR WHICH IT WAS ISSUED. UNAUTORIZED USE, REPRODUCTION, DISCLOSER OR RETENTION IS EXPRESSLY PROHIBITED. ALL PROPRIETARY AND MANUFACTURING RIGHTS RESERVED.
DESIGN HISTORY
INITIAL DRAWN BY
R. RACHO
PROJECT ENGINEER
M. PANOSSIAN
01/11/2005
01-27-00
3
DATE
A
RECTIFIER
DWG. NO.
SIZE
B
SCALE
2
4603
DO NOT SCALE DRAWING
1:2
1
SHEET
REV
L
OF
1
1
4603.slddrw
Loading...