Adams Rite 4533-25-IB, 4533-26-IB, 4533-35-IB, 4533-36-IB Installation Instructions

DIMENSIONS
Inches
(Millimeters)
C
"A"
STILE PREPARATION
"A"
BACK OF STILE
C
L
L
"B"
.980
24.9
"A"
6.38 162
5.80
147.3
6.81 173
.42
10.6
Turning Key / Handle / Paddle DOES NOT pull Main Latch Assy.
.63
15.9
1.587
40.3
1.437
36.5
C
1.00
25.4
.62
15.7
C
"A"
L
C
"A"
C
L
C
HOW BACKSET
IS MEASURED
2.769
70.3
OPERATION INSTRUCTION
Press Aux Latch to secure Main Latch. Turn key, apply voltage, or operate Paddle/Handle to unlock Main Latch. As door opens, Main Latch pivots and collapses.
.182
.182
[20.32]
[20.32]
CYLINDER
C
L
L
1.594
[40.48]
Flat Face Plate can be
FLAT
L
adjusted for right or left beveled edge doors. Radius Weather Strip is optional.
BEVEL
L
FOR OPTIMUM LOCK PERFORMANCE, THE GAP BETWEEN THE DOOR AND FRAME MUST MEET INDUSTRY STANDARDS OF AN 1/8"
DOOR
C
L
C
R.120
R.120
[3.0]
[3.0]
.611
.611
[15.52]
[15.52]
TO JAMB EDGE
AVAILABLE FACEPLATES
FLAT
RADIUS
RADIUS WEATHER STRIP
5.375
136.5
4.635
117.7
L
.06
[1.5]
6.885
[174.9]
1.010
25.7
+
-
+
+.005
-.000
+.38
-.00
.015 .000
0.4 0
R.156 [3.96] TYP.
6.38
162.1
2x
#10-32
UNC-2B
INSTALLATION
(Must use a Face Plate for installation)
CYLINDER
C
L
C
L
1.437
[36.5]
C
L
C
L
2.769
[70.3]
Adjustable Mounting Tube Bracket may be removed for mounting on bridges, tabs, or either methods.
4581
FRONT VIEW
Adams Rite Manufacturing Co.
260 Santa Fe Street,
Pomona, CA 91767
Phone: 909-632-2300
Fax: 909-632-2369
www.adamsrite.com
CAM TOLERANCE: ±.005 ( ±.13 )
4300 SERIES ELECTRIFIED DEADLATCH
80-0180-421
Rev.
D
ECN:11899
.570
14.5 Drill and c'sk for
#10-32 X 1/2" Flat Head Machine Screws
PRODUCT MUST BE INSTALLED
ACCORDING TO ALL APPLICABLE
BUILDING AND LIFE SAFETY CODES
4581 Cam Plug Assy. (included with 4300)
INSTALLATION INSTRUCTIONS
Page of12
Appvd: MP
Date: 03/16/12
Depth
Dim.
#8-32 x 5/16" Truss Head Screw
Depth Dim.
Yoke
Remove Bevel Tabs
Fig. 6
Inside Stile wall
Fig. 1
Tube Spacer
Fig. 2
RADIUS WEATHERSEAL
FACEPLATES ONLY
Screwdriver
3/16" Hex Key
Mounting Plate
Fig. 3
SOLENOID SPECIFICATION
SOLENOID AVAILABLE VOLTAGES 12V DC CONTINUOUS DUTY, 24V DC CONTINUOUS DUTY.
SOLENOID WIRING DIAGRAM
BROWN
YELLOW
BLUE
4300
ORANGE
12V DC
ELECTRIFIED DEADLATCH
Fig. 7
4300 SERIES
WIRES BUNDLE
BROWN
YELLOW
BLUE
4300
ORANGE
24V DC
Fig. 4
VOLTAGE
ADAPTOR CABLE
FLAT FACE PLATE
NEUTRAL POSITION
INTERMITTENT / CONTINUOUS DUTY 12 / 24V DC
120V AC
LINE
VOLTAGE
4605 / 4606 -24V AC
40 VA TRANSFORMER
4300 WIRING DIAGRAM
4603
2-AMP
RED -
RED -
- LOOP THE WIRES BUNDLE FROM 4300 ELECTRIFIED 'S SOLENOID UNDER AND AROUND ITS HOUSING AS SHOWN (Fig.7).
- EXTEND THE WIRES RUN FROM THE POWER SOURCE AND THROUGH THE STILE PREPARATION.
- CONNECT THE WIRE TO THE VOLTAGE ADAPTOR CABLE.
- ATTACH VOLTAGE ADAPTOR CABLE TO 4300 WIRES BUNDLE AS SHOWN.
RECTIFIER
WHITE (+)
4300
ELECTRIFIED DEADLATCH
BLACK (-)
Bevel
Tab
RHR BEVEL POSITION
Fig. 5
LHR BEVEL POSITION
MONITORING (OPTIONAL)
MONITORED DEADLATCH CONTAINS AN INTERNALLY MOUNTED SWITCH. THIS SWITCH IS ACTIVATED WHEN THE DOOR IS IN CLOSE POSITION. ALL UNUSED LEADS FROM THE MONITOR SWITCH MUST BE INSULATED.
Common contact - Black Normally Open contact (N.O.) - White Normally Closed contact (N.C.) - Red Maximum switching current - 0.1 Amps @ 125 VAC
EXAMPLE WIRING DIAGRAM WITH N.O. MONITORING
Black
4300 MONITOR
White
Red
Access Control System
X
Black = Common White = N.O. contact (Dry) Red = N.C. contact (Dry) Unused wires must be cut such that no exposed wire will touch any metallic surface
Note: NOT intend to be a Rex switch.
Adams Rite Manufacturing Co.
260 Santa Fe Street,
Pomona, CA 91767
Phone: 909-632-2300
Fax: 909-632-2369
www.adamsrite.com
4300 SERIES ELECTRIFIED DEADLATCH
80-0180-421
Rev.
D
ECN: 11899
PRODUCT MUST BE INSTALLED
ACCORDING TO ALL APPLICABLE
BUILDING AND LIFE SAFETY CODES
INSTALLATION INSTRUCTIONS
Page of
2 2
Appvd: MP
Date: 03/16/12
Loading...